13.07.2015 Views

Heating with air and geothermal heat - Viessmann

Heating with air and geothermal heat - Viessmann

Heating with air and geothermal heat - Viessmann

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ContentsCompliant scroll compressor


4/5About this brochureHeat pumps from <strong>Viessmann</strong> offer tailor-made solutions for central <strong>heat</strong>ing<strong>and</strong> convenient hot water supply, for both new build <strong>and</strong> modernisation.Saving energy <strong>and</strong> protecting the climatefrom page 6By modernising the <strong>heat</strong>ing system, the system user makes anactive contribution towards protecting the climate <strong>and</strong> savingfossil fuels.<strong>Heating</strong> <strong>with</strong> <strong>heat</strong> pumpsfrom page 10<strong>Viessmann</strong> <strong>heat</strong> pumps utilise the potential <strong>heat</strong>ing energythat nature has provided, in the form of <strong>geothermal</strong> <strong>heat</strong>,groundwater or <strong>air</strong>, which are available free of charge.Cooling <strong>with</strong> <strong>heat</strong> pumpsfrom page 40With the natural <strong>and</strong> active cooling functions, a <strong>heat</strong> pump canalso be used to cool living spaces. Most <strong>Viessmann</strong> <strong>heat</strong> pumpsare already equipped <strong>with</strong> this function.Domestic ventilation systemsfrom page 64An efficient domestic ventilation system does not just ensurefresh <strong>air</strong> <strong>and</strong> a pleasant atmosphere – it even protects the fabricof the building, <strong>and</strong> recovering latent <strong>heat</strong> via the ventilationsystem saves energy.A perfect match – system technologyfrom page 80Advanced system technology has the <strong>heat</strong>ing system undercontrol. Individual control options via mobile phone, internet<strong>and</strong> PC allow you maximum operating convenience <strong>and</strong>economical operation.Service for every aspect of <strong>heat</strong>ingfrom page 88<strong>Viessmann</strong>'s trade partners in the <strong>heat</strong> pump sector offernon-binding <strong>and</strong> free information regarding tailor-made <strong>heat</strong>ingtechnology for new build <strong>and</strong> modernisation, as well as subsidy<strong>and</strong> finance options.


Introduction


6/7Saving energy <strong>and</strong> protecting the climate<strong>Viessmann</strong> is aware of its responsibility for sustained protection of the environment.Our company philosophy <strong>and</strong> products have been constructed <strong>with</strong> this duty in mind."Nothing is so good that it cannot beimproved". This maxim is also reflected inour company principles. In this industry,<strong>Viessmann</strong> can rightfully claim to be theleader in quality <strong>and</strong> technology, <strong>and</strong> as such,aims to continually set new st<strong>and</strong>ards.Of course, this applies in particular tothe company's product range, which isconsistently geared towards significantlylowering the consumption of fossil fuels,<strong>and</strong> gradually replacing them <strong>with</strong> renewablesources of energy.At around 40 percent, the <strong>heat</strong>ing marketactually accounts for the largest proportionof energy consumption in Germany. The restis shared by "goods transport", "personaltransport" <strong>and</strong> "power", <strong>with</strong> 20 percent each.These are values that can also be appliedapproximately to other industrial countries.Ever-rising energy costs mean that theemphasis is on reducing the consumption offossil fuels as quickly as possible <strong>and</strong> utilisingthese fuels <strong>with</strong> greater efficiency.Heat from nature<strong>Heating</strong> from <strong>Viessmann</strong>Heat pumps should be your first choice if yourpriorities are both to save on <strong>heat</strong>ing costs<strong>and</strong> to generate <strong>heat</strong> in an environmentallyresponsible way. After all, the environmentgives us an unlimited <strong>and</strong> free supply of theenergy a <strong>heat</strong> pump uses. This fully‐fledged<strong>heat</strong>ing system only consumes littlepower for drives <strong>and</strong> pumps to make thatenergy available. A <strong>heat</strong> pump makes youindependent of fossil fuels, <strong>and</strong> in additionmakes an active contribution towardsreducing CO 2emissions <strong>and</strong> protectingthe climate.As a pioneer in the field of st<strong>and</strong>ard <strong>heat</strong>pumps, <strong>Viessmann</strong> has been settingst<strong>and</strong>ards in efficient utilisation of energy <strong>and</strong>longevity of service life <strong>with</strong> its advancedsystems for 30 years. This means thesystem user also benefits from <strong>Viessmann</strong>'smany years of experience as a supplier ofcomprehensive <strong>heat</strong>ing systems.Whether for modernisation or new build:<strong>Viessmann</strong> always has the right solution!<strong>Viessmann</strong> offers energy efficient<strong>heat</strong>ing systems for oil, gas, solar,biomass, <strong>air</strong> <strong>and</strong> <strong>geothermal</strong> <strong>heat</strong>.The pictograms are designed toaid orientation when selectinga system.


IntroductionSimple principle, great resultA <strong>heat</strong> pump works in a similar way to a fridge – simply the other way round.VITOCAL 300In a fridge, <strong>heat</strong> is transferred from theinside to the outside. With a <strong>heat</strong> pump,this happens exactly the other way round.Heat from the <strong>air</strong> or the ground is transferredinto the living space via the <strong>heat</strong>ing system.Vapour from a refrigerant is compressed toincrease the temperature, to make it highenough for central <strong>heat</strong>ing <strong>and</strong> DHW <strong>heat</strong>ing.In this process, the Vitocal 350-G reachesup to 72 °C; the Vitocal 350-A up to 65 °C.These <strong>heat</strong> pumps can therefore also beused for modernisation as they can provide asufficiently high flow temperature for central<strong>heat</strong>ing <strong>with</strong> radiators.Highly efficient scroll compressorThe compression process is vital for theefficiency of a <strong>heat</strong> pump. For this, <strong>Viessmann</strong>uses a Compliant scroll compressor. Itis characterised by quiet operation, lowvibrations, low maintenance <strong>and</strong> an extremelylong service life.To generate <strong>heat</strong>, for example, <strong>heat</strong> isextracted from the ambient <strong>air</strong> <strong>and</strong> used toevaporate a refrigerant that boils at lowHeat pumptemperature. The gas created is compressedby the scroll compressor, which causes it to<strong>heat</strong> up. The gas <strong>heat</strong>ed in this way transfersits <strong>heat</strong> via the condenser to the <strong>heat</strong>ingwater or DHW <strong>heat</strong>ing system, <strong>and</strong> therebycondenses again. Finally, the refrigerant,which is still under pressure, is exp<strong>and</strong>edin an expansion valve, <strong>and</strong> the circuitbegins again.A <strong>heat</strong> pump can make use of thefollowing energy sources:• Air – practically unlimited availability;lowest investment costs• Ground – via <strong>geothermal</strong> collector or<strong>geothermal</strong> probe; very efficient• Water – extremely efficient; observewater quality• Waste <strong>heat</strong> – subject to availability, volume<strong>and</strong> temperature level of the waste <strong>heat</strong>The best <strong>heat</strong> source for each individual casedepends on local conditions <strong>and</strong> the actual<strong>heat</strong> dem<strong>and</strong>.Seasonal performance factorThe coefficient of performance (COP) isthe ratio of the <strong>heat</strong> transfer to the powerconsumption. The seasonal performancefactor is the average of all COPs occurringin a year.Compression processThe coefficient of performance is used tocompare <strong>heat</strong> pumps <strong>with</strong> regard to efficiency,yet only applies from a particular operatingpoint under defined temperature conditions.55 °CGroundtemperature all year round between 5 <strong>and</strong> 18 °C (at 2 m depth)Getting hotter towards the centre – from an initialtemperature of between 5 <strong>and</strong> 18 °C, a flow temperatureof up to 72 °C is achieved.For planning (for example, to be able tospecify the consumption costs arising fromusing a <strong>heat</strong> pump), it is necessary to considerthe <strong>heat</strong> pump operation over the wholeyear. For this, the <strong>heat</strong> volume transferredover the year is given in relation to the overallelectrical power drawn by the <strong>heat</strong> pumpsystem over the same period. This includesthe amounts of power used by pumps, controlunits, etc. The result is given as the seasonalperformance factor.


8/9Ground source(collector)Ground source(probe)1 2 3 1 2 3Ground source(ice store)5Air source411 2 3Ground source (groundwater)1 2 312345Vitocal <strong>heat</strong> pumpDHW cylinder<strong>Heating</strong> water buffer cylinderIce storeSolar/<strong>air</strong> absorber


Heat pumps10/11VITOCALAs a homeowner, it is easy to become frustrated at the constantly rising prices of fossil fuels.Why not make yourself independent of them, by relying on proven technology instead?Vitocal <strong>heat</strong> pumps from <strong>Viessmann</strong> utilisethe natural <strong>heat</strong> from the environment. It isunlimited <strong>and</strong> free. This <strong>heat</strong>ing technologyis amongst the most economical <strong>and</strong> cleanof all options for <strong>heat</strong> production. To ensurethat this remains the case <strong>and</strong> that <strong>heat</strong>pump technology is continuously improved<strong>and</strong> therefore becomes even more efficient,<strong>Viessmann</strong> is putting innovative development<strong>and</strong> improvement at the top of its list.Vitocal is always the right choiceCompared to conventional <strong>heat</strong>ing systems,Vitocal <strong>heat</strong> pumps have many advantages:• Utilising environmentally responsibleenergy from the <strong>air</strong> <strong>and</strong> <strong>geothermal</strong> <strong>heat</strong>• No combustion of fossil fuels• Greater independence from risingenergy prices• Optimum combination <strong>with</strong> solartechnologyMilestones in <strong>Viessmann</strong><strong>heat</strong> pump developmentHeat pumpSplit <strong>heat</strong><strong>with</strong> 65 °C flowpumps <strong>with</strong>temperature <strong>with</strong>DC inverterEVI processIn-housedevelopment,technology2012First <strong>Viessmann</strong><strong>heat</strong>ing <strong>heat</strong>pumpsS08 <strong>and</strong> L081982HxR <strong>heat</strong>exchanger <strong>with</strong>swirl vane inthe refrigerantcircuitPatent1996Heat pumpcontrol unit <strong>with</strong>integral naturalcooling functionFirst st<strong>and</strong>ardproduction19982002Vitotres 343passive housecompactappliancefirst st<strong>and</strong>ard<strong>heat</strong> pumpCoated evaporatorfor corrosive mediaSt<strong>and</strong>ard since2005 for all<strong>air</strong> source<strong>heat</strong> pumps2003200520072008RefrigerantdistributionRegisteredutility modelRCD systemPatent pendingElectronic expansion Integral operatingvalve (EEV)manualIn series productionin all 300 series modelsEnergy statement20093-D sound conceptfor low noiseemissions2010Stratified <strong>heat</strong>ing<strong>with</strong> PW modulationSt<strong>and</strong>ard in<strong>heat</strong>ing centresHigh efficiency pumpsIn the 300 seriesDomesticventilation systemVitovent 300-FPV own powerutilisation incontroller1978First weathercompensated<strong>heat</strong>pump control unitfor mono <strong>and</strong> dualmode systems(Oktamatik)Through RCD systemFirst modulating <strong>air</strong>source <strong>heat</strong> pump<strong>with</strong> a COP of 3.8 <strong>with</strong><strong>air</strong> 2 °C / water 35 °C<strong>and</strong> digital scrolltechnology


Product rangeHeat pumps1.5 to 2000 kWBrine/water or water/water <strong>heat</strong> pumpsVITOCAL 350-GSingle stage <strong>heat</strong> pumpBrine/water <strong>heat</strong> pump: 7.3 to 18.7 kWWater/water <strong>heat</strong> pump: 10.3 to 25.7 kWPage 16For new build <strong>and</strong> modernisationDetached housesVITOCAL 350-GTwo-stage <strong>heat</strong> pump(master/slave)Brine/water <strong>heat</strong> pump: 14.6 to 37.4 kWWater/water <strong>heat</strong> pump: 20.6 to 51.4 kWPage 16For new build <strong>and</strong> modernisationDetached houses, apartment buildings, commercial propertyVITOCAL 343-G/VITOCAL 333-GCompact <strong>heat</strong> pumps (brine/water)5.9 to 10.3 kWVitocal 343-G cylinder capacity: 220 l, <strong>with</strong> solar functionVitocal 333-G cylinder capacity: 170 l, including all componentsfor natural coolingPage 20For new build <strong>and</strong> detached housesVITOCAL 300-GSingle stage <strong>heat</strong> pumpBrine/water <strong>heat</strong> pump: 5.9 to 42.8 kWWater/water <strong>heat</strong> pump: 7.9 to 58.9 kWPage 24For new build <strong>and</strong> modernisationDetached houses, apartment buildings, commercial propertyVITOCAL 300-GTwo-stage <strong>heat</strong> pump(master/slave)Brine/water <strong>heat</strong> pump: 11.8 to 85.6 kWWater/water <strong>heat</strong> pump: 15.8 to 117.8 kWPage 28For new build <strong>and</strong> modernisationDetached houses, apartment buildings, commercial property


12/13VITOCAL 300-G PROBrine/water <strong>heat</strong> pump93 to 240 kWPage 30VITOCAL 300-W PROWater/water <strong>heat</strong> pump122 to 290 kWHeat pumps up to 2 MWFor <strong>heat</strong>ing <strong>and</strong>/or coolingFor further information, see our brochure"Heat pumps up to 2000 kW".GroupVITOCAL 242-G/VITOCAL 222-GCompact <strong>heat</strong> pumps(brine/water)5.9 to 10 kWVitocal 242-G cylinder capacity: 220 l, <strong>with</strong> solar functionVitocal 222-G cylinder capacity: 170 lPage 32For new build <strong>and</strong> detached housesVITOCAL 200-GBrine/water <strong>heat</strong> pump5.8 to 17.2 kWPage 36For new build <strong>and</strong> detached housesNatural/active coolingNC-BoxNatural cooling boxUp to 5 kW cooling capacityPage 42AC-BoxActive cooling boxUp to 13 kW cooling capacity


Product rangeHeat pumps1.5 to 2000 kWAir/water <strong>heat</strong> pumpsVITOCAL 350-AAir/water <strong>heat</strong> pump(internal or external installation)10.6 to 18.5 kWPage 44For new build <strong>and</strong> modernisationDetached house/apartment buildingVITOCAL 300-AAir/water <strong>heat</strong> pump(internal or external installation)3 to 9 kW, modulatingPage 48For new build <strong>and</strong> modernisationDetached housesDual mode systemsVITOCAL 242-S/222-SSplit compact <strong>heat</strong> pump(<strong>air</strong>/water)3 to 10.6 kWVitocal 242-S cylinder capacity: 220 l, <strong>with</strong> solar functionVitocal 222-S cylinder capacity: 170 lPage 52For new build <strong>and</strong> detached housesVITOCAL 200-SSplit <strong>air</strong>/water <strong>heat</strong> pump3 to 10.6 kWPage 56For new build <strong>and</strong> modernisationDetached housesDual mode systems


14/15DHW <strong>heat</strong> pumpVITOCAL 160-ADHW <strong>heat</strong> pump1.5 kWCylinder capacity: 285 l,<strong>with</strong> <strong>and</strong> <strong>with</strong>out ventilation functionPage 62For new build <strong>and</strong> modernisationDetached housesDomestic ventilation systemsVITOVENT 300-FDomestic ventilation system <strong>with</strong> <strong>heat</strong> recoveryfor dem<strong>and</strong>-dependent domestic ventilationUp to 280 m 3 /h <strong>with</strong> integral bypass circuitPage 66VITOVENT 300Domestic ventilation system <strong>with</strong> <strong>heat</strong> recoveryfor dem<strong>and</strong>-dependent domestic ventilation180 m 3 /h300 <strong>and</strong> 400 m 3 /h <strong>with</strong> integral bypass circuitPage 68


Heat pumps Vitocal 350-G


16/17VITOCAL 350-GHeat pump <strong>with</strong> a maximum flow temperature of 72 °C.The first choice for high DHW convenience in detached houses <strong>and</strong> apartment buildings.The single stage Vitocal 350-G <strong>heat</strong> pumpreaches a high flow temperature of 72 °C.This makes it particularly suitable forconvenient DHW <strong>heat</strong>ing.It is available as either a brine/water orwater/water <strong>heat</strong> pump, <strong>and</strong> for higher <strong>heat</strong>dem<strong>and</strong>s in two-stage operation, can becombined <strong>with</strong> a further <strong>heat</strong> pump of thesame type, or <strong>with</strong> the Vitocal 300-G, as amaster/slave. Both <strong>heat</strong> sources are thenregulated via a control unit.Extremely quiet <strong>and</strong> economical operationWith its anti-vibration <strong>and</strong> sound-optimiseddesign, the Vitocal 350-G is extremely quiet.This means the <strong>heat</strong> pump can even besited close to living spaces <strong>with</strong>out causinga problem.EHPA quality seal as proof ofthe COP, for subsidy accordingto the German market incentiveprogramme


Heat pumpsVitocal 350-GThe innovative RCD system, which providescontinuous refrigerant cycle control, ensureshigh efficiency at any operating point.The use of an electronic expansion valve(EEV) <strong>and</strong> high efficiency pumps (<strong>with</strong> typeBWC), as well as the high COP of 4.6, alsocontribute to the low running costs. Finally,the integral energy statement for central<strong>heat</strong>ing <strong>and</strong> DHW provides the basis forproperty developers to apply for subsidies[in Germany] for their environmentallyresponsible investment.Vitotronic 200 control unit <strong>with</strong>communication capabilityFollowing a st<strong>and</strong>ardised operatingphilosophy, <strong>Viessmann</strong> now uses theconvenient Vitotronic 200 control unit inall its <strong>heat</strong> sources. The extensive functionsinclude user guidance <strong>with</strong> menu prompts,an integral diagnostic system, control of theinstantaneous <strong>heat</strong>ing water <strong>heat</strong>er, control ofan additional (existing) oil or gas boiler, <strong>and</strong> ofcourse, the natural or active cooling functions.Furthermore, the Vitotronic 200 is capableof communicating, <strong>and</strong> via the Vitocom 300module, it allows the <strong>heat</strong> pump system tobe set up, monitored <strong>and</strong> optimised overthe internet.In combination <strong>with</strong> solar technologyAn advanced <strong>heat</strong>ing system shouldinclude innovative solar technology. Forthis, <strong>Viessmann</strong> offers the Vitocal 350-G, aperfectly matched system for utilising freesolar energy for supplying DHW. On hot dayselectricity is then only required to run thecirculation pumps.123Vitocal 350-GType BWC 351.A451 Vitotronic 200 <strong>heat</strong> pump control unit2 Condenser3 Large area evaporator for efficient<strong>heat</strong> transfer4 Integral high efficiency pumps for brine<strong>and</strong> <strong>heat</strong>ing circuits, plus circulation pumpfor cylinder <strong>heat</strong>ing5 Hermetically sealed Compliant scrollcompressor


18/19Two-stage Vitocal 350-G (master/slave) as a brine/wateror water/water <strong>heat</strong> pumpTake advantage of these benefits:Display of the Vitotronic 200 <strong>heat</strong> pump control unit• Brine/water <strong>heat</strong> pump<strong>Heating</strong> outputs, single stage: 7.3 <strong>and</strong> 18.7 kW; two-stage: 14.6 <strong>and</strong> 37.4 kW• Water/water <strong>heat</strong> pump<strong>Heating</strong> outputs, single stage: 10.3 <strong>and</strong> 25.7 kW; two-stage: 20.6 <strong>and</strong> 51.4 kW• Low operating costs through high coefficients of performance:COP value to EN 14511 up to 4.6 (brine 0 °C/water 35 °C)• High DHW convenience• High efficiency all year round at any operating point through innovative RCDsystem (continuous refrigerant cycle control)• Mono mode operation for DHW <strong>and</strong> central <strong>heat</strong>ing• Extremely quiet operation through sound-optimised appliance design• Even suitable for radiators thanks to flow temperatures up to 72 °C• Possible cylinder temperatures in excess of 60 °C• Vitotronic 200 control unit <strong>with</strong> energy statement accepted by bodiesoffering subsidies• Master/slave solutions for higher <strong>heat</strong> dem<strong>and</strong>s, e.g. combination <strong>with</strong>the Vitocal 300-GFor specification, see page 70


Heat pumps Vitocal 343-GVitocal 333-G


20/21VITOCAL 343-GVITOCAL 333-G NCVITOCAL 333-GSystem solutions for detached housesVitocal 333-G, compact brine/water <strong>heat</strong> pump <strong>with</strong> DHW cylinderVitocal 333-G NC, including all components for natural coolingVitocal 343-G, generally including the option to connect to a solar thermal systemThe Vitocal 343-G <strong>and</strong> Vitocal 333-Gwere developed as compact <strong>and</strong> highlyefficient solutions for new build. As part ofthis development, generously sized <strong>heat</strong>exchangers have been integrated to enable ahigh COP (COP = coefficient of performance)of 4.7 to be achieved, in accordance <strong>with</strong>EN 14511, <strong>with</strong> brine 0 °C/water 35 °C.The seasonal performance factor specifiesthe relationship between the <strong>heat</strong> volume(<strong>heat</strong>ing energy) transferred <strong>and</strong> the energy(drive energy) supplied, over the course of ayear. The innovative RCD (Refrigerant CycleDiagnostic) system played a vital role in theimprovement of the seasonal performancefactor. This system enables a highly precise<strong>and</strong> rapid control of the refrigerant circuitvia an electronic expansion valve. TheRCD system ensures that the <strong>heat</strong> pumpoperates <strong>with</strong> optimum efficiency at everyoperating point.With solar cylinder or natural coolingVitocal 343-G is designed for the connectionof a solar thermal system for DHW <strong>heat</strong>ing. Agenerously sized solar cylinder <strong>with</strong> 220 litrecapacity <strong>and</strong> a solar control unit have beenintegrated into the appliance for this purpose.In the compact Vitocal 333-G, a DHW cylinder<strong>with</strong> 170 litre capacity ensures a convenientsupply of DHW. To help cool you down onhot summer days, the Vitocal 333-G is alsoavailable in a version <strong>with</strong> an integral naturalcooling function.EHPA quality seal as proof ofthe COP, for subsidy accordingto the German marketincentive programmeIn addition, energy saving, high efficiencypumps for the brine <strong>and</strong> <strong>heat</strong>ing circuitsensure very low consumption costs <strong>and</strong>therefore a high seasonal performance factorin all three output sizes.


Heat pumpsVitocal 343-GVitocal 333-GCompact <strong>heat</strong> pumpsThe Vitocal 343-G <strong>and</strong> Vitocal 333-G areoffered as three versions, i.e. <strong>with</strong> <strong>and</strong> <strong>with</strong>outsolar thermal connection <strong>and</strong> <strong>with</strong> integralnatural cooling function. DHW cylinders <strong>with</strong>170 litre capacity (solar version <strong>with</strong> 220 litre)are integrated to safeguard high DHWconvenience. At the core of the appliance isa newly developed high efficiency <strong>heat</strong> pumpmodule.These compact appliances are particularlyeconomical thanks to the refrigerant circuit<strong>with</strong> electronic expansion valve (EEV) <strong>and</strong>the <strong>Viessmann</strong>-developed RCD (RefrigerantCycle Diagnostic) system, plus the st<strong>and</strong>ardenergy saving high efficiency pumps. Thisis reflected day by day <strong>and</strong> year by year inhigh seasonal performance factors <strong>and</strong> lowconsumption costs.Small footprintWith their space saving designs, theVitocal 343-G <strong>and</strong> Vitocal 333-G areparticularly suitable for situations wherespace is restricted. The brine circulationpump, <strong>heat</strong>ing circuit pump <strong>and</strong> the 3-waydiverter valve are already integrated insidethe compact casing that completelyprotects the refrigeration module/hydrauliccompartment from the outside environment<strong>and</strong>, in conjunction <strong>with</strong> the three-dimensionalanti-vibration mounts, minimises operatingnoise. These compact <strong>heat</strong> pumps are someof the quietest in their category, as they onlygenerate 38 dB(A) at brine 0 °C/water 35 °C.For easier h<strong>and</strong>ling, the height of the unitwas reduced <strong>and</strong> the casing was designedto split into sections. Variable connectionaccessories supplied ex works make <strong>heat</strong>pump installation easier.1Extremely easy to operateLike all our compact appliances, theVitocal 343-G <strong>and</strong> Vitocal 333-G, too, areequipped <strong>with</strong> the user friendly Vitotroniccontrol unit. If in doubt, help is available at thepush of a button. The graphic interface willalso display <strong>heat</strong>ing curves <strong>and</strong> solar yield.32Always accessibleSubject to dem<strong>and</strong>, the Vitotronic control unitcan be fitted <strong>with</strong> convenient communicationtechnology. From Vitocom 100 toVitocom 300, versatile remote monitoring<strong>and</strong> remote control options are available,independent of the system user's location.Vitocal 333-G1 DHW cylinder,170 litre capacity2 Vitotronic 200<strong>heat</strong> pump control unit3 Internal indirect coilcylinder <strong>heat</strong>ing4 Primary pump(high efficiency pump)5 Secondary pump475(high efficiency pump)6 Hermetically sealedCompliant scrollcompressor7 Diverter valve68<strong>heat</strong>ing/DHW8 Integral instantaneous<strong>heat</strong>ing water <strong>heat</strong>er


22/23The compact <strong>heat</strong> pumps Vitocal 343-G <strong>and</strong> Vitocal 333-Gcontain the system components for central <strong>heat</strong>ing <strong>and</strong>DHW <strong>heat</strong>ing.Take advantage of these benefits:The Vitotronic control unit <strong>with</strong> large, multi line, graphicdisplay can also indicate the solar yield.• Compact brine/water <strong>heat</strong> pumps <strong>with</strong> <strong>heat</strong>ing outputs from 5.9 to 10.3 kW• Low operating costs through high coefficients of performance: COP to EN 14511of 4.7 (brine 0 °C/water 35 °C)• High DHW convenience through integral DHW cylinder <strong>with</strong> 220 litre capacity inthe Vitocal 343-G (Vitocal 333-G <strong>with</strong> 170 litre capacity)• Maximum flow temperature of up to 60 °C for high DHW convenience• Integral power saving high efficiency pumps (Energy Label A)• Very quiet thanks to a new sound insulation concept resulting in a sound powerlevel of 38 dB(A) at brine 0 °C/water 35 °C• Vitotronic control unit that is easy to operate <strong>with</strong> plain text display• Ready to connect, ex works• Easy h<strong>and</strong>ling through reduced height <strong>and</strong> split casing• Convenient <strong>and</strong> compact through integral NC (natural cooling) function for theVitocal 333-G• Can be extended <strong>with</strong> convenient communication technology• Instantaneous <strong>heat</strong>ing water <strong>heat</strong>er integrated as st<strong>and</strong>ard• Optimised utilisation of self-generated power from photovoltaic systemsFor specification, see page 71


Heat pumps Vitocal 300-G


24/25VITOCAL 300-GThe Vitocal 300-G <strong>heat</strong> pump utilises the renewable <strong>heat</strong> stored underground or ingroundwater. A two-stage version is available for high <strong>heat</strong>ing outputs.As a single stage brine/water <strong>heat</strong> pump,the Vitocal 300-G obtains <strong>heat</strong> from theground. This does not necessitate drillinga <strong>geothermal</strong> probe or laying <strong>geothermal</strong>collectors on the property. In both cases, the<strong>heat</strong> pump covers the entire energy dem<strong>and</strong>,even on colder days.As an alternative, depending on the locationof the house, it may also be possible to utilisethe <strong>heat</strong> contained in groundwater. In thiscase, the Vitocal 300-G is simply configuredfor operation as a water/water <strong>heat</strong> pump. Itcan be used for new build <strong>and</strong> modernisationin detached houses <strong>and</strong> apartment buildings.The Vitocal 300-G iscertified in accordance<strong>with</strong> the EHPA qualityseal for Heat Pumps.


Heat pumpsVitocal 300-GHigh output <strong>and</strong> quiet operationThe powerful Compliant scroll compressorfitted in the Vitocal 300-G <strong>heat</strong> pump isoutst<strong>and</strong>ing on account of its high operationalsafety, reliability <strong>and</strong> especially quietoperation. Essentially, this is due to the twinsound insulation that includes anti-vibrationmounts to prevent structure-borne noise <strong>and</strong>insulates the casing against <strong>air</strong>-borne noise.At the same time, the compressor guaranteesthe highest coefficients of performance (COPup to 4.9) <strong>and</strong> flow temperatures up to 60 °C.The Refrigerant Cycle Diagnostic (RCD)system constantly monitors the refrigerantcircuit in the Vitocal 300-G <strong>and</strong>, in conjunction<strong>with</strong> the electronic expansion valve, ensuresthe highest efficiency at any operatingpoint, which results in high seasonalperformance factors.Vitotronic 200, <strong>with</strong> energystatement facilityThe Vitotronic 200 is simple <strong>and</strong> intuitive tooperate, thanks to the plain text user prompts<strong>and</strong> graphic display. Amongst other features,it enables an integral differentiated energystatement, which is accepted by subsidybodies [in Germany].Modular solution for higher <strong>heat</strong> dem<strong>and</strong>For residential buildings <strong>with</strong> a higher <strong>heat</strong>dem<strong>and</strong>, the two-stage Vitocal 300-G,based on the master/slave principle is theright choice. It can also be configured forthe ground or groundwater as the <strong>heat</strong>source. For this purpose, two <strong>heat</strong> pumpsare linked together. This does not just deliverthe high <strong>heat</strong>ing output required, but it alsoincreases the operational reliability of theentire system. The modular design, <strong>with</strong>separate compressor circuits, also ensuresparticularly high levels of efficiency in partialload operation, <strong>and</strong> enables the simultaneousoperation of central <strong>and</strong> DHW <strong>heat</strong>ing.With five output stages as a master ormaster/slave version, various combinationscan be realised <strong>and</strong> matched to the required<strong>heat</strong> dem<strong>and</strong>. Because of this flexibility,systems can be configured so that runtimesmatch dem<strong>and</strong>, thus saving you money. Themaster module regulates the slave module.Furthermore, the entire system can beequipped <strong>with</strong> high efficiency pumps.1234Vitocal 300-G51 Vitotronic 200 <strong>heat</strong> pump control unit2 Condenser3 Large area evaporator for efficient<strong>heat</strong> transfer4 High efficiency pump5 Hermetically sealed Compliant scrollcompressor


26/27The Vitocal 300-G <strong>heat</strong> pump utilises the renewable <strong>heat</strong>stored underground or in groundwater.Take advantage of these benefits:Two-stage <strong>heat</strong> pump Vitocal 300-G (master/slave) –a pipework set <strong>with</strong> fittings <strong>and</strong> shut-off valves is availablefor the hydraulic connection of the <strong>heat</strong> pump modules.Fully wired cables are used to connect the control unit.• Maximum efficiency for new build <strong>and</strong> modernisation in detached houses <strong>and</strong>apartment buildingsBrine/water <strong>heat</strong> pump<strong>Heating</strong> outputs, single stage: 5.9 to 17.0 kW; two-stage: 11.8 to 34.0 kWWater/water <strong>heat</strong> pump<strong>Heating</strong> outputs, single stage: 7.9 to 23.0 kW; two-stage: 15.8 to 46.0 kW• Vitocal 300-G: <strong>with</strong> integral high efficiency pump for brine <strong>and</strong> <strong>heat</strong>ing circuits,plus circulation pump for cylinder <strong>heat</strong>ing, safety assembly <strong>with</strong> safety valve,pressure gauge <strong>and</strong> <strong>air</strong> vent valve (for types BWC <strong>and</strong> WWC)• Low operating costs through high coefficients of performance: COP value toEN 14511 up to 4.9 (brine 0 °C/water 35 °C) <strong>and</strong> integral high efficiency pumps(for Vitocal 300-G, types BWC <strong>and</strong> WWC)• Maximum flow temperatures up to 60 °C• High efficiency all year round at any operating point through innovativeRCD system <strong>with</strong> electronic expansion valve• Extremely quiet operation below 42 dB(A) through sound-optimisedappliance design• Vitotronic 200 control unit <strong>with</strong> energy statement (meets BAFA subsidy terms[Germany])• Master/slave solutions for very high flexibility, for example combination ofVitocal 300-G <strong>and</strong> 350-GFor specification, see page 72


Heat pumpsVitocal 300-GEHPA quality seal asproof of the COP, forsubsidy according tothe German marketincentive programmeThe Vitocal 300-G is a specialist appliancefor large detached houses <strong>and</strong> apartmentbuildings. It utilises <strong>heat</strong> that's right on yourdoorstep, either <strong>with</strong> a single stage brine/water <strong>heat</strong> pump, from 21.2 to 42.8 kW,or <strong>with</strong> a water/water <strong>heat</strong> pump from28.1 to 58.9 kW – tailored to the specific<strong>heat</strong> dem<strong>and</strong>.For apartment buildings or applications whichrequire very high outputs, the two-stageVitocal 300-G, based on the master/slaveprinciple, is the right choice. It can deliver a<strong>heat</strong>ing output from 42.4 to 85.6 kW (brine/water) or from 56.2 to 117.8 kW (water/water). You also have the choice between thegroundwater or the ground as your preferred<strong>heat</strong> source. If this output is still insufficient,it can be increased to up to 589 kW (water/water) via the cascade function integrated intothe control unit.Powerful <strong>and</strong> reliableAt the heart of the Vitocal 300-G lies itspowerful Compliant scroll compressor. Thisconvinces <strong>with</strong> a high degree of operationalsafety <strong>and</strong> reliability. In conjunction <strong>with</strong>the generously sized <strong>heat</strong> exchangers <strong>and</strong>the integral refrigerant manifold, theVitocal 300-G achieves high coefficientsof performance <strong>and</strong> flow temperatures ofup to 60 °C.Quiet operation <strong>and</strong> high output are notmutually exclusiveThe hermetically sealed casing <strong>and</strong> particularlyclever appliance design enable a reduction innoise emissions in the Vitocal 300-G that farexceeds expectations in this output range.RCD system for highest level of efficiencyRCD st<strong>and</strong>s for Refrigerant Cycle Diagnosticsystem. It provides permanent monitoring ofthe refrigerant circuit <strong>with</strong>in the Vitocal 300‐G<strong>and</strong>, in conjunction <strong>with</strong> the electronicexpansion valve, ensures the highest level ofefficiency at any operating point.Perfect even for high <strong>heat</strong> dem<strong>and</strong>Especially for a higher <strong>heat</strong> dem<strong>and</strong>, theVitocal 300-G is the first choice, becauseseveral <strong>heat</strong> pumps can be linked via the<strong>heat</strong>ing flow <strong>and</strong> return. This does not justdeliver the higher <strong>heat</strong>ing output required, butit also increases the operational reliability ofthe entire system. The modular design, <strong>with</strong>separate compressor circuits, also ensuresparticularly high levels of efficiency in partialload operation, <strong>and</strong> enables the simultaneousoperation of central <strong>and</strong> DHW <strong>heat</strong>ing.1234Vitocal 300-G51 Weather-compensated, digitalVitotronic 200 <strong>heat</strong> pump control unit2 Condenser3 Large area evaporator for efficient<strong>heat</strong> transfer4 Hermetically sealed Compliant scrollcompressor5 Electronic expansion valve


28/29Two-stage Vitocal 300-G (master/slave) as a brine/water orwater/water <strong>heat</strong> pumpModular solution in master/slaveoperationWith three output sizes, as master or master/slave version, various combinations can berealised, which can all be precisely matchedto the required <strong>heat</strong> dem<strong>and</strong>. The availabilityof different versions <strong>and</strong> the ability to sizeaccording to dem<strong>and</strong> enables systems to beconfigured so that runtimes are optimised,ensuring economical operation. The mastermodule regulates the slave module. Bycombining different output sizes, users havethe option of matching the environmentallyresponsible <strong>heat</strong>ing system to their specific<strong>heat</strong> dem<strong>and</strong> as efficiently as possible byutilising different modules.Take advantage of these benefits:• Brine/water <strong>heat</strong> pump<strong>Heating</strong> output, single stage: 21.2 to 42.8 kW; two-stage: 42.4 to 85.6 kW;maximum 342.4 kW (as cascade)• Water/water <strong>heat</strong> pump<strong>Heating</strong> output, single stage: 28.1 to 58.9 kW; two-stage: 56.2 to 117.8 kW;maximum 589 kW (as cascade)• Low operating costs through high coefficients of performance: COP to EN 14511up to 4.8 (brine 0 °C/water 35 °C)• Flow temperatures up to 60 °C• Mono mode operation for DHW <strong>and</strong> central <strong>heat</strong>ing• Low running costs <strong>with</strong> the highest level of efficiency at any operating pointthrough the innovative RCD (Refrigerant Cycle Diagnostic) system <strong>with</strong>electronic expansion valve (EEV)• Quiet, <strong>with</strong> low vibrations, thanks to sound-optimised appliance design; soundpower below or equal to 44 dB(A)• With integral energy statement• Vitotronic 200 <strong>heat</strong> pump control unit <strong>with</strong> user prompts for weathercompensated<strong>heat</strong>ing operation• Easier h<strong>and</strong>ling through small <strong>and</strong> light modulesFor specification, see page 73


Heat pumpsVitocal 300-G ProEasy-to-operate Vitotroniccontrol unit <strong>with</strong> plain text <strong>and</strong>graphic displayThe modular st<strong>and</strong>ard <strong>heat</strong> pump forhigh output<strong>Viessmann</strong> extends the company’s rangeof st<strong>and</strong>ard <strong>heat</strong> pumps up to 290 kW inthe form of the new Vitocal 300-G Pro<strong>heat</strong> pump. The Pro Series features all ofthe characteristics of the highly efficientVitocal 300-G series. The five output sizesenable most requirements from residentialbuildings <strong>and</strong> commerce to be reliably met.St<strong>and</strong>ardising these appliances enables quick<strong>and</strong> comprehensive engineering, as well asproviding transparent calculation parameters.In its class, the Vitocal 300-G Pro is the only<strong>heat</strong> pump <strong>with</strong> an integral energy statementfacility. Higher output levels can be achievedby linking up to five Vitocal 300-G Pro in asingle cascade.Pre-assembled electrical equipmentThe electrical equipment is already integratedinside the <strong>heat</strong> pump casing as st<strong>and</strong>ard.Factory-fitted contactors for fail-safe primary<strong>and</strong> secondary pumps, as well as protectionfor the compressor, guarantee little installationeffort, as well as the safe <strong>and</strong> rapid systemintegration of the <strong>heat</strong> pump.Proven <strong>and</strong> reliable technologyThe control philosophy was adopted from theVitocal series for detached <strong>and</strong> two-familyhouses. Here too, the Refrigerant CycleDiagnostic (RCD) system ensures a constantefficiency check <strong>and</strong> safeguards the efficient<strong>and</strong> reliable function at any operating pointthrough the interaction between the electronicexpansion valve (EEV) <strong>and</strong> extensive sensortechnology. The Vitotronic 200 regulatesup to three <strong>heat</strong>ing circuits plus the DHWcylinder, <strong>and</strong> ensures a pleasant ambience onhot summer days thanks to its natural coolingfunction. An extensive range of adjustmentsas well as system optimisation are madepossible from anywhere, via the internetor mobile phone utilising the Vitocom 300communication module that is available asan option.Space efficient designThe hermetically sealed construction of theCompliant scroll compressors <strong>and</strong> the R410Arefrigerant both significantly reduce the spacerequired for siting these appliances. At only88 cm wide, <strong>with</strong> a facility to lift the unit ona pallet truck, plus removable casing panels,h<strong>and</strong>ling is made very easy.Installation room <strong>with</strong> long term testing


30/31Vitocal 300-G ProType BW 190Take advantage of these benefits:Vitocal 300-G ProType BW 2180, 2250• Brine/water <strong>heat</strong> pump, single <strong>and</strong> two-stage<strong>Heating</strong> output: 93 to 240 kW; maximum 1200 kW (as cascade)• Water/water <strong>heat</strong> pump, single <strong>and</strong> two-stage<strong>Heating</strong> output: 122 to 290 kW; maximum 1450 kW (as cascade)• Low operating costs through high coefficients of performance: COP to EN 14511up to 4.8 (brine 0 °C/water 35 °C) <strong>and</strong> up to 5.9 (water 10 °C/water 35 °C)• Maximum flow temperature 60 °C (brine 5 °C)• Low noise <strong>and</strong> vibration emissions through sound-optimised appliance design• Low operating costs <strong>with</strong> the highest level of efficiency at any operatingpoint through the innovative RCD (Refrigerant Cycle Diagnostic) system <strong>with</strong>electronic expansion valve (EEV)• Easy-to-operate Vitotronic control unit <strong>with</strong> plain text <strong>and</strong> graphic display• The only <strong>heat</strong> pump in this output range <strong>with</strong> an integral energystatement facility• Pre-installation of many electrical components including protection <strong>and</strong>contactors, so system can be up <strong>and</strong> running more quickly• Ready-to-use connection for fail-safe primary <strong>and</strong> secondary pumps• Electronic soft starter for lower starting current <strong>and</strong> less power drawn fromthe mains• Water/water version <strong>with</strong> stainless steel tubular evaporator for operation<strong>with</strong>out intermediate circuitFor specification, see page 74


Heat pumps Vitocal 242-GVitocal 222-G


32/33VITOCAL 242-GVITOCAL 222-GCompact brine/water <strong>heat</strong> pumps <strong>with</strong> DHW cylinder <strong>and</strong>, as an alternative,the option to connect a solar thermal system.Complete <strong>and</strong> extremely compact – theVitocal 242-G <strong>and</strong> Vitocal 222-G compact<strong>heat</strong> pumps are fully equipped <strong>with</strong> all thecomponents required for DHW <strong>and</strong> central<strong>heat</strong>ing. With <strong>heat</strong>ing outputs of between5.9 <strong>and</strong> 10.0 kW, they are designed for use indetached houses, <strong>and</strong> flow temperatures ofup to 60 °C mean they can also be used <strong>with</strong>conventional radiators.The Vitocal 242-G <strong>and</strong> Vitocal 222-G areattractively priced alternatives to thecompact appliances of the 300 series. Withthe Compliant scroll compressor <strong>and</strong> athermostatically controlled expansion valve,they achieve coefficients of performanceof up to 4.3 (to EN 14511 <strong>with</strong> brine 0° C/water 35 °C). For the <strong>heat</strong>ing <strong>and</strong> brinecircuits, three-stage adjustable circulationpumps are integrated into the appliances.Vitocal 242-G is fully prepared forsolar operationVitocal 242-G is fully prepared for theconnection of a solar thermal system forDHW <strong>heat</strong>ing. A 220 litre solar cylinder <strong>and</strong> asolar control unit enable high solar <strong>heat</strong> yields.Vitocal 222-G <strong>with</strong> 170 litre DHW cylinderThe Vitocal 222-G compact <strong>heat</strong> pump offersa high level of DHW convenience thanks to its170 litre DHW cylinder, which is <strong>heat</strong>ed via aninternal indirect coil.The Vitocal 242-G <strong>and</strong>Vitocal 222-G havebeen tested accordingto the EHPA quality sealfor Heat Pumps.Operating the appliances is extremely easythanks to the Vitotronic control unit.Solar collectorsVitocal 242-G


Heat pumpsVitocal 242-GVitocal 222-GNatural <strong>heat</strong> for modern detached housesThe Vitocal 242-G <strong>and</strong> Vitocal 222-G compact<strong>heat</strong> pumps are specifically designed fordetached houses. With their extremelycompact dimensions of just over 0.4 squaremetres, they need only a small installationarea. With integral DHW cylinder, brine <strong>and</strong><strong>heat</strong>ing circuit pumps, plus a 3-way divertervalve, these compact appliances are quick<strong>and</strong> easy to install. They are offered in twodifferent versions. The Vitocal 242-G hasa solar function <strong>and</strong> a generously sizedDHW cylinder <strong>with</strong> 220 litre capacity. TheVitocal 222-G has a 170 litre cylinder. Both<strong>heat</strong> pumps offer high DHW convenience.Extremely easy to operateLike all compact appliances, the Vitocal 222‐Gis equipped <strong>with</strong> the new user friendlyVitotronic control unit. If in doubt, help isavailable at the push of a button. The graphicinterface will also display <strong>heat</strong>ing curves <strong>and</strong>switching times.Particularly quiet operationThe sound-optimised appliance design makesthese compact <strong>heat</strong> pumps particularly quietso that they can even be installed close to theliving space.Compact <strong>and</strong> ready to connectThe casing may be split for easier h<strong>and</strong>ling.The <strong>heat</strong> pump is supplied ready to connect.Variable connection accessories ensure aneasy installation on site.<strong>Heating</strong> naturally – naturally coolingas wellThe compact <strong>heat</strong> pumps can provide apleasant climate in a low energy house, evenin hot summers. The natural cooling functionbrings cool underground temperatures intothe home. For this, the <strong>Viessmann</strong> NC-Box isrequired as an accessory.Vitocal 242-G1243Vitocal 242-G including optionalutilisation of solar energyWith the Vitocal 242-G, the connections fora solar thermal system are already in place,<strong>with</strong> the required hydraulic connections <strong>and</strong>the control unit integrated. The powerfulcollectors <strong>and</strong> matching system componentsfrom <strong>Viessmann</strong> back up the <strong>heat</strong> pump –meaning in an average year, 50 to 60 percentof energy usually spent on DHW <strong>heat</strong>ing canbe saved.1 <strong>Heating</strong> lance2 Enamelled5DHW cylinder3 Vitotronic 200 <strong>heat</strong>pump control unit4 Integral solar indirect coil5 PWM-controlled68cylinder primary pump(pulse width modulation)6 Primary circulation pump77 Secondary circulationpump8 Diverter valve9<strong>heat</strong>ing/DHW9 Integral instantaneous<strong>heat</strong>ing water <strong>heat</strong>er


34/35The compact <strong>heat</strong> pumps fully live up to their reputation:low space requirement <strong>and</strong> no service clearances to the side,making them fit easily into even the tightest of recesses.Take advantage of these benefits:Easy-to-operate Vitotronic control unit <strong>with</strong> simplenavigation <strong>and</strong> clear menu structure.• Compact brine/water <strong>heat</strong> pumps <strong>with</strong> <strong>heat</strong>ing outputs from 5.9 to 10.0 kW• Low operating costs through high coefficients of performance: COP to EN 14511up to 4.3 (brine 0 °C/water 35 °C)• Maximum flow temperature: 60 °C• High DHW convenience through integral DHW cylinder <strong>with</strong> 220 litre capacity inthe Vitocal 242-G (Vitocal 222-G <strong>with</strong> 170 litre capacity)• Very quiet thanks to the sound-optimised appliance design <strong>with</strong> a sound powerlevel of 43 dB(A) at 0/35 °C• Vitotronic control unit that is easy to operate <strong>with</strong> plain text display• Ready to connect, ex works• Easy h<strong>and</strong>ling through small footprint, reduced height <strong>and</strong> split casing• Easy installation through variable connection accessories• Can be extended <strong>with</strong> convenient communication technology• Instantaneous <strong>heat</strong>ing water <strong>heat</strong>er integrated as st<strong>and</strong>ard• Optimised utilisation of self-generated power from photovoltaic systemsFor specification, see page 75


Heat pumps Vitocal 200-G


36/37VITOCAL 200-GAttractively priced <strong>heat</strong> pump for uncomplicated <strong>heat</strong> supply <strong>and</strong> high level ofDHW convenience in new build.With its excellent price/performance ratio, thecompact brine/water <strong>heat</strong> pump Vitocal 200-Gis ideally suited to detached houses. With itsoutput spectrum of 5.8 to 17.2 kW in monomode, it delivers a convenient <strong>heat</strong> supply allyear round.Thanks to innovative technology using theefficient Compliant scroll compressor, theVitocal 200-G achieves a maximum flowtemperature of 60 °C <strong>and</strong> is therefore alsosuitable for <strong>heat</strong>ing the living space <strong>with</strong>radiators. High DHW convenience is alsoensured. This makes the Vitocal 200-G anall‐round complete entry model for new build.The Vitocal 200-G iscertified in accordance<strong>with</strong> the EHPA qualityseal for Heat Pumps.


Heat pumps Vitocal 200-GTwo <strong>heat</strong>ing circuits for individual<strong>heat</strong>ing convenienceThe convenient brine/water <strong>heat</strong> pumpoffers all functions required for using a<strong>heat</strong> pump in a new detached home. Theweather-compensated Vitotronic 200 controlunit allows two separate <strong>heat</strong>ing circuits tobe connected.Installation <strong>and</strong> assembly made easyThe Vitocal 200-G is delivered complete<strong>with</strong> integral high efficiency pumps forthe brine <strong>and</strong> <strong>heat</strong>ing circuits, circulationpump for cylinder <strong>heat</strong>ing, <strong>and</strong> the safetyassembly. This means the <strong>heat</strong>ing contractorcan complete the installation quickly<strong>and</strong> inexpensively.Prepared for subsidiesWith the installation of an optional <strong>heat</strong>meter, the purchase of the Vitocal 200-G<strong>heat</strong> pump can be subsidised <strong>with</strong> publicgrants [in Germany]. It would then meet therequirements of the Renewable EnergiesHeat Act (EEWärmeG).A further benefit is the option to temporarilyfit a booster <strong>heat</strong>er, for example for screeddrying. The <strong>heat</strong>ing contractor would fit thebooster <strong>heat</strong>er for a specific period using amulti connect system.Easy to use Vitotronic 200 control unitThe Vitotronic 200 <strong>heat</strong> pump control unit,<strong>with</strong> its graphic interface, is simple <strong>and</strong>intuitive to use. The most important valuescan be seen at a glance. The natural coolingfunction is already integrated. To use this, anNC-Box from the range of accessories mustbe added to the Vitocal 200-G.1234Vitocal 200-G51 Vitotronic 200 <strong>heat</strong> pump control unit2 Condenser3 Large area evaporator for efficient<strong>heat</strong> transfer4 High efficiency pump5 Hermetically sealed Compliant scrollcompressor


38/39Attractively priced Vitocal 200-G brine/water <strong>heat</strong> pumpTake advantage of these benefits:Display of the Vitotronic 200 <strong>heat</strong> pump control unit• Brine/water <strong>heat</strong> pump <strong>with</strong> <strong>heat</strong>ing output from 5.8 to 17.2 kW• Affordable entry model for detached houses• Low operating costs through high coefficients of performance: COP to EN 14511up to 4.5 (brine 0 °C/water 35 °C)• Provides all DHW <strong>and</strong> central <strong>heat</strong>ing in mono mode operation all year round• Maximum flow temperature up to 60 °C• Quiet operation <strong>with</strong> low vibrations thanks to sound-optimised appliance design;sound power below 45 dB(A)• Vitotronic 200 control unit <strong>with</strong> menu prompts, plain text <strong>and</strong> graphic display forweather-compensated mode <strong>and</strong> natural cooling• Heat pump is fully fitted <strong>and</strong> equipped at the factory; high efficiency circulationpump for brine <strong>and</strong> <strong>heat</strong>ing circuits, plus circulation pump for cylinder <strong>heat</strong>ing,are already integrated• Easy to install through complete equipment level <strong>and</strong> pre-assembly• Heat meter can be retrofitted (option)For specification, see page 75


Heat pumps40/41Cooling <strong>with</strong> <strong>heat</strong> pumpsAlongside pleasant <strong>heat</strong>ing convenience <strong>and</strong> reliable DHW <strong>heat</strong>ing, <strong>heat</strong> pumps alsoprovide cooling for a building.No-one would turn on the central <strong>heat</strong>ing ona hot summer day. With a <strong>Viessmann</strong> <strong>heat</strong>pump, the situation is different, as sometypes offer an additional cooling function.Active or passive coolingCooling operates according to two differentmethods:• Passive cooling: This is where the brinemedium or the groundwater absorbsthe energy from the <strong>heat</strong>ing circuit via a<strong>heat</strong> exchanger <strong>and</strong> transfers it outside.This function is also called natural cooling,as it uses the natural ambient temperature.Apart from the control unit <strong>and</strong>circulation pump, the <strong>heat</strong> pump remainsswitched off.Natural cooling – naturallyWhile the ground or groundwater is usedin winter to provide energy for <strong>heat</strong>ing, insummer it can be used for natural cooling.With the natural cooling function, the controlunit only starts the primary pump <strong>and</strong> <strong>heat</strong>ingcircuit pump. This means the relatively hotwater from the underfloor <strong>heat</strong>ing systemcan transfer its <strong>heat</strong> via the <strong>heat</strong> exchanger tothe brine in the primary circuit. This extracts<strong>heat</strong> from all rooms that are connected, whichmakes natural cooling a particularly energyefficient <strong>and</strong> affordable way to cool buildings.• Active cooling: For this, the function of the<strong>heat</strong> pump is simply reversed. This methodof cooling can be described as "reverseoperation". This means that the refrigerantcircuit is reversed internally or reversal isachieved by an external changeover of theprimary <strong>and</strong> secondary circuits. As <strong>with</strong> afridge, cooling is then actively generated bythe <strong>heat</strong> pump.NC-BoxOptional equipment for<strong>Viessmann</strong> <strong>heat</strong> pumps toprovide passive coolingPage 42AC-BoxOptional equipment for<strong>Viessmann</strong> <strong>heat</strong> pumps toprovide active coolingPage 43


Natural coolingNC-BoxEnergy efficient <strong>and</strong> affordable cooling<strong>with</strong> the NC-BoxThe <strong>Viessmann</strong> NC-Box helps <strong>heat</strong> pumpsto provide cooling in a completely naturalway. In fact, it’s really quite simple. On hotsummer days, the temperatures inside thehouse are higher than those in the groundor groundwater. The <strong>heat</strong> pump control unitthen switches to natural cooling, <strong>and</strong> uses theground or groundwater to dissipate the <strong>heat</strong>from your living space.Saving while coolingThe natural cooling function does not use allthe technology of the brine/water <strong>heat</strong> pump.This means that, apart from the control unit<strong>and</strong> circulation pumps, all other functionsremain off. Only a very small amount ofpower is therefore consumed for operation.This makes natural cooling a particularlyenergy efficient <strong>and</strong> affordable method forcooling buildings.Everything you need to keep coolIn the <strong>Viessmann</strong> "Natural Cooling Box", allcomponents are prefitted. This makes thethermally insulated box not only compact, butalso particularly simple <strong>and</strong> quick to install.With or <strong>with</strong>out mixerDepending on the sort of cooling needed, thenatural cooling box comes in two differentversions, either <strong>with</strong> or <strong>with</strong>out mixer. Theintegral mixer enables continuous operation<strong>with</strong>out falling below the dew point.The effective thermal insulation of the NC-Box prevents theformation of condensate.


Active coolingAC-Box42/43The AC-Box efficiently combines<strong>heat</strong>ing <strong>and</strong> coolingThe <strong>Viessmann</strong> AC-Box combines active<strong>and</strong> natural cooling in <strong>heat</strong> pump systems,thus making them even more versatile<strong>and</strong> convenient. The system changes overautomatically according to the required roomtemperature. If only a low cooling capacityis required, natural cooling is sufficient, butif that is no longer enough active coolingis added.Cooling using tiny amounts of energyWith natural cooling, the compressor circuitis not needed. Only the brine <strong>and</strong> <strong>heat</strong>ingcircuit pumps are operational <strong>and</strong> utilise thetemperature differential between the rooms<strong>and</strong> the ground or groundwater. In this way,rooms can be cooled very cost effectively.Keep cool when it gets really hot outsideWith active cooling, the compressorcircuit starts to work. However, it does notprovide <strong>heat</strong>ing – the internal control unit, inconjunction <strong>with</strong> the AC-Box, reverses theoutput <strong>and</strong> input functions to actively transfer<strong>heat</strong> out of the building to the <strong>geothermal</strong>probe. Cold water then flows through the<strong>heat</strong>ing circuit itself – cooled down to 7 °Cif required.Utilising extracted energyIncidentally, direct use can also be madeof the <strong>heat</strong> transferred out of the rooms inthis way, for example for DHW <strong>heat</strong>ing or to<strong>heat</strong> a swimming pool. This means cooling<strong>and</strong> <strong>heat</strong>ing functions can be combinedextremely effectively.Well developed technology:The AC-Box (to the left of the <strong>heat</strong>pump) simply starts the relevant<strong>heat</strong> pump function – eitheractive or natural cooling, dependingon the required cooling capacity.


Heat pumpsVitocal 350-A


44/45VITOCAL 350-AThanks to high flow temperatures, a <strong>heat</strong>ing system can even be modernised <strong>with</strong>an <strong>air</strong>/water <strong>heat</strong> pump.The Vitocal 350-A <strong>air</strong>/water <strong>heat</strong> pump<strong>with</strong> rated <strong>heat</strong>ing outputs 10.6 to 18.5 kWis particularly suitable for modernisationprojects. Thanks to enhanced vapourinjection in the compression process(EVI cycle), developed by <strong>Viessmann</strong>, flowtemperatures of up to 65 °C can be achieved– even at wintry outside temperatures. Thismeans the Vitocal 350-A is also suitablefor installation in older <strong>heat</strong>ing systems<strong>with</strong> radiators. To increase efficiency, werecommend replacing individual radiators <strong>with</strong>ultra-low temperature ones.The Vitotronic 200 <strong>heat</strong> pump control unithas an integral cascade function for up to five<strong>air</strong>/water <strong>heat</strong> pumps. Cumulative <strong>heat</strong>ingoutputs of up to 92.5 kW are thereforepossible for a high <strong>heat</strong> dem<strong>and</strong>.RCD system for particularly high efficiencyThe electronic expansion valve <strong>and</strong> RCDsystem also ensure an extremely high level ofefficiency for the Vitocal 350-A all year round.For <strong>air</strong> source <strong>heat</strong> pumps, the Vitocal 350‐Aoffers a high coefficient of performance ofup to 3.6 (in accordance <strong>with</strong> EN 14511 at<strong>air</strong> 2 °C/water 35 °C). This results in highseasonal performance factors <strong>and</strong> very lowoperating costs.Space saving thanks to externalinstallationThe Vitocal 350-A can be installed eitherinternally or externally. The three-stageradial fan in the <strong>heat</strong> pump, as well as theflow-optimised <strong>air</strong> routing <strong>and</strong> the soundinsulated casing together make the Vitocal350-A extremely quiet. During night operationthe variable stage fan control unit reducesthe speeds <strong>and</strong> thus the noise emissionseven further.The Vitocal 350-A iscertified in accordance<strong>with</strong> the EHPA qualityseal for Heat Pumps.


Heat pumpsVitocal 350-AIdeal for modernisationThe Vitocal 350-A <strong>air</strong> source <strong>heat</strong> pumpmakes modernising easy. The additionalvapour injection during the compressionprocess (EVI cycle) enables a flowtemperature of up to 65 °C. It is thereforeideal for older <strong>heat</strong>ing systems <strong>with</strong> existingradiators. For this, the <strong>heat</strong> pump draws itsenergy from the ambient <strong>air</strong>.High DHW convenienceSubject to system version, a higher flowtemperature enables a water temperatureof up to 55 °C inside the DHW cylinder.This allows the Vitocal 350-A to deliver aparticularly high level of DHW convenience.The Vitocal 350-A achieves the high flowtemperature of 65 °C, even at outsidetemperatures of -10 °C.RCD guarantees efficient operationRCD st<strong>and</strong>s for Refrigerant Cycle Diagnosticsystem. In the Vitocal 350-A, it is responsiblefor permanently monitoring the refrigerantcircuit. This, in conjunction <strong>with</strong> the electronicexpansion valve (EEV), ensures the highestefficiency at every operating point. Alongsidethis, important operating parameters aresaved <strong>and</strong> called up, when required, fordiagnosis, optimisation, energy statements<strong>and</strong> to calculate the seasonal performancefactor (SPF).Spot onIf the <strong>heat</strong> pump is installed outside, the <strong>heat</strong>needs to be "transported" to the interior of thehouse. In this, you can rely on <strong>Viessmann</strong>'scompetence in <strong>heat</strong>ing systems. All thepipework required for routing underground,as well as the entire range of accessories,are provided from one single source, <strong>and</strong> areperfectly matched to one another.13242567Vitocal 350-A1 Intake side2 Discharge side3 Evaporator4 Radial fan5 Electronic expansion valve6 Evaporator for intermediate injection7 Hermetically sealed scroll compressor<strong>with</strong> vapour injection (EVI)


46/47Impressive qualities: high operational safety, reliability <strong>and</strong>quiet running due to the Compliant scroll compressorTake advantage of these benefits:Vitocal 350-A for internal installation• Air/water <strong>heat</strong> pump, mono mode <strong>with</strong> a <strong>heat</strong>ing output of 10.6 to 18.5 kW forDHW <strong>and</strong> central <strong>heat</strong>ing• Particularly suitable for modernisation through 65 °C flow temperature, even atcold outside temperatures in winter• DHW temperature subject to system version up to 55 °C• Low operating costs through high coefficients of performance: COP to EN 14511up to 3.6 (<strong>air</strong> 2 °C/water 35 °C)• High efficiency all year round at any operating point <strong>and</strong> therefore lowconsumption costs through the innovative RCD (Refrigerant Cycle Diagnostic)system, <strong>with</strong> an electronic bi-flow expansion valve (EEV)• Low operating noise through radial fan, sound-optimised appliance design <strong>and</strong>night operation <strong>with</strong> reduced fan speed• Easy-to-operate Vitotronic 200 <strong>heat</strong> pump control unit <strong>with</strong> TeleControl <strong>and</strong>remote monitoring for connection to the Vitocom 100, 200 or 300, plus cascadefunction for up to five <strong>heat</strong> pumps• Installation inside or outside <strong>with</strong> matching accessories• As an option <strong>with</strong> high efficiency pump for the <strong>heat</strong>ing circuit <strong>with</strong> Vitocal 350-A(internal installation)• Efficient defrosting through circuit reversal• With integral energy statementFor specification, see page 77


Heat pumpsVitocal 300-A


48/49VITOCAL 300-AWith modulating <strong>air</strong>/water <strong>heat</strong> pumps, advanced technology guarantees the highest levelof efficiency in any operating state.The energy available in the <strong>air</strong> is extremelyeasy to use for <strong>heat</strong>ing buildings <strong>and</strong>domestic hot water. It is even possible at lowtemperatures in winter, when the dem<strong>and</strong>for <strong>heat</strong> is high. This is no problem for theVitocal 300-A <strong>air</strong> source <strong>heat</strong> pump. It isparticularly efficient <strong>and</strong> even at an outsidetemperature of 6 °C can still deliver a flowtemperature of 60 °C.<strong>Heating</strong> efficiently <strong>with</strong> <strong>air</strong>The Vitocal 300-A <strong>air</strong>/water <strong>heat</strong> pumpis extremely efficient <strong>and</strong> achieves highseasonal performance factors. Its output issufficient for both central <strong>and</strong> DHW <strong>heat</strong>ing.This makes bills for fossil fuels a thing of thepast. Only electrical power for the <strong>heat</strong> pumpsystem is required.Higher convenience, lower investmentNo additional investment is required to installa Vitocal 300-A <strong>air</strong> source <strong>heat</strong> pump. Thereis no drilling work for <strong>geothermal</strong> probes orlaying a <strong>geothermal</strong> collector. You may notneed a costly buffer cylinder or primary storesystem either, thanks to output matched toyour needs <strong>and</strong> optimum operation.Finally, depending on the building structure,the Vitocal 300-A can be sited outsideor inside.The Vitocal 300-A iscertified in accordance<strong>with</strong> the EHPA qualityseal for Heat Pumps.


Heat pumpsVitocal 300-ATop technology for top performanceThe Vitocal 300-A is the first <strong>air</strong> source <strong>heat</strong>pump <strong>with</strong> digital scroll technology <strong>and</strong> anelectronic bi-flow expansion valve. This meansit achieves an extremely high COP value(COP = coefficient of performance) of 3.9(at <strong>air</strong> 2 °C/water 35 °C), enabling exemplaryseasonal performance factors, too. What'smore, this makes the Vitocal 300-A particularlyreliable where <strong>heat</strong> supply is concerned <strong>and</strong>very frugal when it comes to running costs.RCD system for an optimum<strong>heat</strong> pump operationRCD st<strong>and</strong>s for Refrigerant Cycle Diagnosticsystem. It provides constant monitoring of therefrigerant circuit <strong>with</strong>in the Vitocal 300-A <strong>and</strong>,in conjunction <strong>with</strong> the electronic expansionvalve, ensures the highest level of efficiency atany operating point.Not only quiet at nightParticularly quiet operation is ensured by aradial fan <strong>with</strong> variable speed control <strong>and</strong> areduced fan speed for night operation.Suitable for every dem<strong>and</strong>Every household has different <strong>heat</strong> dem<strong>and</strong>s,<strong>and</strong> the conditions for installing a <strong>heat</strong>pump vary. The range of accessories forthe Vitocal 300-A is suitably flexible <strong>and</strong>comprehensive. Subject to dem<strong>and</strong>, the<strong>heat</strong> pump can be supplied fully equipped.This means the high efficiency pump(Energy Label A), 3-way diverter valve <strong>and</strong>safety equipment have already been fullyfitted. Even the modular electric instantaneous<strong>heat</strong>ing water <strong>heat</strong>er can be easily integrated.Finally, <strong>Viessmann</strong> also offers the completeproduct range to meet the dem<strong>and</strong>s of anyinstallation you require – inside or out.Monitor <strong>and</strong> control from whereveryou areWith the control unit of the Vitocal 300-A,the <strong>heat</strong> pump can simply be connected tothe Vitocom 100, 200 or 300. The <strong>heat</strong>ingsystem can then be conveniently controlledvia mobile phone.12Cooling in summer – no problemReversible operation turns the Vitocal 300‐Ainto a convenient cooling system in the hotsummer months. Convectors or surfacecooling systems <strong>with</strong> a cooling capacityof up to 9.4 kW offer the flexibility tomake the temperature in living areas evenmore pleasant.345Vitocal 300-A1 Evaporator2 Radial fan3 Electronic expansion valve4 Condenser5 Digital scroll compressor


50/51The RCD system, the digital scroll technology <strong>and</strong> theelectronic bi-flow expansion valve guarantee the highestlevel of efficiency at every operating point.Take advantage of these benefits:Vitocal 300-A for external installation• Reversible <strong>air</strong> source <strong>heat</strong> pump for <strong>heat</strong>ing <strong>and</strong> cooling, for installationinside <strong>and</strong> outside• Variable output control from 3.0 to 9.0 kW• Low operating costs through high coefficients of performance: COP to EN14511: 3.9 (<strong>air</strong> 2 °C/water 35 °C); 4.4 (<strong>air</strong> 7 °C/water 35 °C)• Maximum flow temperature up to 60 °C at 6 °C outside temperature• High efficiency all year round at any operating point <strong>and</strong> therefore lowconsumption costs through the innovative RCD (Refrigerant Cycle Diagnostic)system, <strong>with</strong> an electronic bi-flow expansion valve (EEV)• Low operating noise through radial fan, sound-optimised appliance design <strong>and</strong>night operation <strong>with</strong> reduced fan speed• Easy-to-operate Vitotronic 200 <strong>heat</strong> pump control unit <strong>with</strong> TeleControl <strong>and</strong>remote monitoring for connection to the Vitocom 100, 200 or 300, plus cascadefunction for up to five <strong>heat</strong> pumps• Integral high efficiency pump for the <strong>heat</strong>ing circuit <strong>with</strong> the Vitocal 300-A(internal installation)• Efficient defrosting through circuit reversal• With integral energy statement• Particularly quiet in "silent version"• Active cooling mode possible through reversible refrigerant circuitFor specification, see page 77


Heat pumpsVitocal 242-SVitocal 222-S


52/53VITOCAL 242-SVITOCAL 222-SCompact split <strong>air</strong> source <strong>heat</strong> pumps for new build <strong>and</strong> modernisation, <strong>with</strong> integralDHW cylinder for a high level of DHW convenience.Split <strong>heat</strong> pumps are characterised by aseparation into a quiet internal unit <strong>and</strong> an <strong>air</strong>h<strong>and</strong>ling external unit. This design does notrequire extensive wall outlets <strong>and</strong> routing of<strong>air</strong> ducts. As systems for <strong>heat</strong>ing only, or assystems that provide <strong>heat</strong>ing <strong>and</strong> cooling,these units are ideal for new build.With the Vitocal 242-S, <strong>Viessmann</strong> offers asplit <strong>heat</strong> pump <strong>with</strong> integral solar functionfor solar DHW <strong>heat</strong>ing. The cylinder capacityis 220 litres. With the Vitocal 222-S (<strong>with</strong>outsolar function), the DHW cylinder has acapacity of 170 litres.A high proportion of pre-assembledcomponents makes these compact <strong>heat</strong>ingcentres easy for <strong>heat</strong>ing contractors to install,which reduces installation costs.The Vitocal 242-S <strong>and</strong> Vitocal 222‐Sare certified in accordance <strong>with</strong> theEHPA quality seal for Heat Pumps.


Heat pumps Vitocal 242-SVitocal 222-SCompact internal unitsWith their timeless design <strong>and</strong> a width of just60 cm, these internal units can be sited closeto the living space (e.g. in the utility room).They contain hydraulic components such asa <strong>heat</strong> exchanger (condenser), DHW cylinder,<strong>heat</strong>ing circuit pump, instantaneous <strong>heat</strong>ingwater <strong>heat</strong>er, 3-way diverter valve, <strong>and</strong>Vitotronic 200 control unit.Heat pump control unit <strong>with</strong> user promptsThe Vitotronic 200 is structured logically,<strong>and</strong> its displays are easy to follow. The largebacklit display offers good contrast, making iteasy to read. The graphic user interface alsodisplays <strong>heat</strong>ing <strong>and</strong> cooling curves.If a solar thermal system is connected to theVitocal 242-S, the solar yield is shown as well.Efficient <strong>and</strong> economicalThe split <strong>heat</strong> pumps operate extremelyeconomically in partial load operation.Inverter technology accurately matchesthe compressor output to the current <strong>heat</strong>dem<strong>and</strong> through modulating operation.This results in high efficiency at anyoperating point.Extensive service from <strong>Viessmann</strong>The external <strong>and</strong> internal units are connectedto the refrigerant lines on site to form asealed refrigerant circuit. Consequently, thelegislature specifies that the installation mustbe carried out by qualified personnel only.<strong>Heating</strong> contractors can acquire the relevantexpertise in accordance <strong>with</strong> the ChemicalSafety Ordinance [Germany] as part of aone-week course at <strong>Viessmann</strong>. The systemcan also be commissioned by <strong>Viessmann</strong>'sTechnical Service department.Prepared for subsidiesWith the installation of an optional <strong>heat</strong> meter,the purchase of Vitocal 242-S/222-S <strong>heat</strong>pumps can be subsidised <strong>with</strong> public grants[in Germany].Vitocal 242-SInternal unit (left)1 <strong>Heating</strong> lance2 EnamelledDHW cylinder3 Vitotronic 200 <strong>heat</strong>pump control unit4 Integral solar indirect coil5 Diverter valve<strong>heat</strong>ing/DHW6 High efficiency pump7 Condenser8 Integral instantaneous<strong>heat</strong>ing water <strong>heat</strong>er1243561Vitocal 200-SExternal unit (right)72 31 Evaporator2 Fan3 Compressor


54/55Vitocal 242-S split <strong>air</strong> source <strong>heat</strong> pumpTake advantage of these benefits:Display of the Vitotronic 200 <strong>heat</strong> pump control unit• Attractively priced split <strong>air</strong> source <strong>heat</strong> pump <strong>with</strong> <strong>heat</strong>ing outputs between3.0 <strong>and</strong> 10.6 kW (<strong>air</strong> 2 °C/water 35 °C at the nominal operating point)• Inverter compressor for optimum output matching to the <strong>heat</strong>ing <strong>and</strong>cooling dem<strong>and</strong>• Low operating costs through high coefficients of performance: COP to EN 14511of up to 4.6 (<strong>air</strong> 7 °C/water 35 °C) <strong>and</strong> 3.5 (<strong>air</strong> 2 °C/water 35 °C)• Maximum flow temperature up to 55 °C at -15 °C outside temperature(<strong>with</strong> reduced output)• High DHW convenience through integral DHW cylinder <strong>with</strong> 220 litre capacityfor the Vitocal 242-S (for Vitocal 222-S <strong>with</strong> 170 litre capacity)• Solar connection for DHW <strong>heat</strong>ing <strong>with</strong> the Vitocal 242-S• Convenient through reversible version that enables <strong>heat</strong>ing <strong>and</strong> cooling• High efficiency in partial load operation through output-controlled compressor• Low sound power level of the external unit in partial load operation throughvariable speed fan <strong>and</strong> compressor• Refrigerant pipework requires no frost protection• Vitotronic 200 control unit that is easy to operate <strong>with</strong> plain text<strong>and</strong> graphic display• Low investment outlay• Easy <strong>and</strong> affordable installation <strong>with</strong>out major wall outlets• Optimised utilisation of self-generated power from photovoltaic systems• Can be commissioned by <strong>Viessmann</strong>'s Technical Service departmentFor specification, see page 78


Heat pumpsVitocal 200-S


M56/57VITOCAL 200-SThe affordable alternative for new build <strong>and</strong> modernisation, which can also be easilycombined <strong>with</strong> existing <strong>heat</strong> sources.<strong>Heating</strong> <strong>and</strong> cooling system <strong>with</strong>internal <strong>and</strong> external unitThe Vitocal 200-S <strong>heat</strong> pump is available aseither a <strong>heat</strong>ing system only or as a systemfor <strong>heat</strong>ing <strong>and</strong> cooling.The Vitocal 200-S utilises the latent <strong>heat</strong> inthe outdoor <strong>air</strong>. The weather-resistant externalunit can be sited where required <strong>and</strong> is easyto install, even on external walls, thanksto its compact dimensions. A freest<strong>and</strong>inginstallation next to the building or on a flat roofis also possible.As <strong>with</strong> other <strong>heat</strong>ing systems, the internalunit is sited in a cellar or utility room insidethe building. It comprises the hydraulics, the<strong>heat</strong> exchanger, a high efficiency circulationpump (compliant <strong>with</strong> Energy Label A) <strong>and</strong> a3-way diverter valve for convenient supply of<strong>heat</strong>ing water <strong>and</strong> DHW. The Vitocal 200-S,type AWB-AC, also includes a three-stageinstantaneous <strong>heat</strong>ing water <strong>heat</strong>er.In summer, the Vitocal 200-S, type AWB‐AC,can also be used to cool the rooms in thebuilding. For this, fan convectors or anunderfloor <strong>heat</strong>ing/cooling system canbe used.The Vitocal 200-S is certified inaccordance <strong>with</strong> the EHPA qualityseal for Heat Pumps.Schematic diagram of a <strong>heat</strong>ing system includingVitocal 200-S in a new building (left) <strong>and</strong> for modernisationVitocal 200-S as <strong>heat</strong>ing system in a new building(System example: AWB-AC)Vitocal 200-S <strong>and</strong> oil/gas boiler fordual mode operation in modernisation projects(System example: AWB)MVitocal 200-SDHWVitocal 200-SDHWBoiler<strong>Heating</strong> waterExternal <strong>and</strong> internal unitcylinderExternal <strong>and</strong>cylinderbuffer cylinderinternal unit


Heat pumps Vitocal 200-SEfficient <strong>and</strong> economicalThe Vitocal 200-S operates <strong>with</strong> astonishingefficiency, particularly in partial load mode. Tothis end, the appliance makes full use of thebenefits offered by a DC inverter. Throughmodulation it matches the compressoroutput precisely to the prevailing dem<strong>and</strong> <strong>and</strong>thereby maintains the required temperature.is structured logically <strong>and</strong> is easy to follow.The large backlit display offers good contrast,making it easy to read. A help functioninforms users of the next steps to perform.The graphic user interface also displays<strong>heat</strong>ing <strong>and</strong> cooling curves. Additionalcomponents from the comprehensive rangecan be easily controlled.When it comes to modernisation, the split<strong>heat</strong> pump is ideally suited for efficient dualmode operation. Under these circumstances,the existing system remains in operation tocover peak loads.Quiet operation through variablespeed controlThe modulating operation of the Vitocal 200-Sreduces the frequency of system starting <strong>and</strong>stopping. In addition, the variable speed fan<strong>and</strong> compressor are significantly less noisythan those that run at constant operation attop speed.Convenient Vitotronic control unitContractor <strong>and</strong> system users benefit equallyfrom the easy-to-operate Vitotronic 200control unit as it provides user prompts,Extensive service from <strong>Viessmann</strong>The external <strong>and</strong> internal units are connectedto the refrigerant lines on site to form asealed refrigerant circuit. Consequently, thelegislature specifies that the installation mustbe carried out by qualified personnel only.<strong>Heating</strong> contractors can acquire the relevantexpertise in accordance <strong>with</strong> the ChemicalSafety Ordinance [Germany] as part of aone-week course at <strong>Viessmann</strong>. The systemcan also be commissioned by <strong>Viessmann</strong>'sTechnical Service department.With design software developed by<strong>Viessmann</strong> in accordance <strong>with</strong> VDI 4650,<strong>heat</strong>ing contractors can calculate whetherpublic subsidies are available for the relevantsystem wherever required.Vitocal 200-SInternal unit1 Integral instantaneous<strong>heat</strong>ing water <strong>heat</strong>er2 Heat exchanger(condenser)3 3-way diverter valve4 High efficiency pump(compliant <strong>with</strong>Energy Label A)5 Vitotronic 20023146Vitocal 200-SExternal unit57 81 Evaporator2 Fan3 Compressor


58/59Vitocal 200-S split <strong>air</strong> source <strong>heat</strong> pumpTake advantage of these benefits:External unit, type AWS_AC110• Attractively priced split <strong>air</strong> source <strong>heat</strong> pump <strong>with</strong> <strong>heat</strong>ing outputs between3.0 <strong>and</strong> 10.6 kW (<strong>air</strong> 2 °C/water 35 °C at the nominal operating point)• Output control <strong>and</strong> DC inverter for high efficiency in partial load operation• Low operating costs through high coefficients of performance: COP to EN 14511of up to 4.6 (<strong>air</strong> 7 °C/water 35 °C) <strong>and</strong> 3.5 (<strong>air</strong> 2 °C/water 35 °C)• Maximum flow temperature up to 55 °C at -15 °C outside temperature(<strong>with</strong> reduced output)• Weather-resistant external unit <strong>with</strong> evaporator, compressor, expansion valve<strong>and</strong> fan• Internal unit <strong>with</strong> high efficiency circulation pump (compliant <strong>with</strong> EnergyLabel A), <strong>heat</strong> exchanger, 3-way diverter valve, safety assembly <strong>and</strong> control unit;for <strong>heat</strong>ing/cooling version <strong>with</strong> integral instantaneous <strong>heat</strong>ing water <strong>heat</strong>er• Vitotronic 200 <strong>heat</strong> pump control unit that is easy to operate <strong>with</strong> plain text<strong>and</strong> graphic display• Convenient thanks to reversible version that enables <strong>heat</strong>ing <strong>and</strong> cooling• Can be commissioned by <strong>Viessmann</strong>'s Technical Service department• Optimised utilisation of self-generated power from photovoltaic systemsFor specification, see page 78


60/61Two thirds less fuel oilInitial situationDual mode systemOil boiler Oil boiler & Heat pumpOutputProportion of annual <strong>heat</strong>ing loadAnnual <strong>heat</strong> dem<strong>and</strong>Efficiency when <strong>heat</strong>ingEnergy dem<strong>and</strong>Proportion of DHWEnergy consumptionEnergy price*Consumption costs*18 kW100 %32,400 kWh90 %36,000 kWh3000 kWh3900 litres oil€0.85 per litre€331518 kW20 %6480 kWh90 %7200 kWh3000 kWh1020 litres oil€0.85 per litre€86718 kW80 %25,920 kWh330 % (SPF 3.3)7855 kWh––7855 kWh (power)€0.14 per kWh (HP)€1100Total* €3315€1967Savings ––approx. €1348* Average valueExample: <strong>Heating</strong> system <strong>with</strong> 55 °C maximum flow temperature, 1800 full utilisation hours, 18 kW <strong>heat</strong> load of the building. DHW <strong>heat</strong>ing by the boiler.House <strong>with</strong> 150 m 2 <strong>and</strong> an annual <strong>heat</strong>ing energy consumption of approx. 39,000 kWh incl. DHW <strong>heat</strong>ing (3000 kWh).


Heat pumps Vitocal 160-AAffordable DHW <strong>heat</strong>ing <strong>with</strong> existing central <strong>heat</strong>ing <strong>and</strong> large cylinder.The Vitocal 160-A <strong>heat</strong>s DHW whilst savingenergy <strong>and</strong> costs. As its <strong>heat</strong> source, it usesthe warm <strong>air</strong> that is always available inside thebuilding. The Vitocal 160-A is ideally suitedfor use anywhere where <strong>heat</strong> is availablein abundance, e.g. in bakeries. It can beoperated completely independently of other<strong>heat</strong> sources.Compact DHW station utilisesambient <strong>heat</strong>The compact Vitocal 160-A DHW <strong>heat</strong>pump is equipped <strong>with</strong> all the componentsnecessary for efficient <strong>and</strong> space savingDHW <strong>heat</strong>ing. Together <strong>with</strong> the <strong>heat</strong> pumpmodule (output 1.52 kW, COP 3.56 at 15 °C<strong>air</strong> temperature <strong>and</strong> 15 to 45 °C watertemperature to EN 255), a 285 litre cylinder,immersion <strong>heat</strong>er <strong>and</strong> control unit are allintegrated inside one casing.Various programs can be convenientlyselected using the easy-to-use control unit<strong>with</strong> its large display. Whether for DHW<strong>heat</strong>ing, constant operation or st<strong>and</strong>by mode– the various functions can be selected at afew keystrokes.Additional benefits of central cooling orcontrolled domestic ventilationThe recirculation <strong>air</strong> <strong>heat</strong> pump, Vitocal 160-A,uses <strong>air</strong> straight from the room in which itis installed. As an extract <strong>air</strong> <strong>heat</strong> pump, itdraws in warm extract <strong>air</strong> via ducts from otherrooms, e.g. the bathroom, WC <strong>and</strong> kitchen.Part of the <strong>heat</strong> from the <strong>air</strong> that is drawn inis extracted, <strong>and</strong> raised by the <strong>heat</strong> pump toa temperature level that can be used to <strong>heat</strong>the DHW.The recirculation <strong>air</strong> <strong>heat</strong> pump thenreturns the cooled <strong>and</strong> dehumidified <strong>air</strong> to theinstallation room. That room can then be usedas a cool larder for groceries.With an extract <strong>air</strong> <strong>heat</strong> pump, the cooled<strong>air</strong> is routed to the outside via an <strong>air</strong> duct. Inconjunction <strong>with</strong> supply <strong>air</strong> apertures thatensure the supply of fresh outdoor <strong>air</strong> to theliving space, the Vitocal 160-A becomes123the central component of a controlleddomestic ventilation system. This makes theVitocal 160-A suitable for modernisation too.456Vitocal 160-A7 71 Highly efficient rotating piston compressor2 Large area evaporator for efficient<strong>heat</strong> transfer3 Pre-programmed control unit, subject toappliance type <strong>with</strong> solar function4 Magnesium anode5 Integral booster <strong>heat</strong>er <strong>with</strong> 1.5 kW<strong>heat</strong>ing output6 Integral enamelled 285 litre DHW cylinder7 Condenser


62/63The compact DHW <strong>heat</strong> pump, Vitocal 160-A, can operateindependently, separate from other <strong>heat</strong> sources.Lower costs through solar energyBoth versions are available <strong>with</strong> an internalindirect solar coil <strong>and</strong> solar control unit.Through the connection of up to six squaremetres of flat-plate collectors or up to threesquare metres of vacuum tube collectors,the free energy of the sun can also beused to <strong>heat</strong> DHW <strong>and</strong> further reduce therunning costs.A 230 V socket is sufficientThe Vitocal 160-A is supplied pre-assembled.Simply install, connect the water pipes <strong>and</strong>condensate drain, <strong>and</strong> plug into a 230 V powersocket – <strong>and</strong> the recirculation <strong>air</strong> <strong>heat</strong> pump isready for operation.Take advantage of these benefits:• Attractively priced DHW <strong>heat</strong> pump for recirculation or extract <strong>air</strong> mode, <strong>with</strong>the option of internal indirect solar coil <strong>and</strong> solar control unit for connectingflat‐plate <strong>and</strong> tube collectors• High COP of 3.56 at A15/W15-45 to EN 255• Air flow rate up to 250 m 3 /h• Cylinder capacity 285 litres, cylinder <strong>with</strong> special enamel coating• Easy commissioning through ready-to-plug-in wiring <strong>and</strong> programmedcontrol unit• DHW <strong>heat</strong> pump for sole <strong>heat</strong>ing of the required DHW in <strong>heat</strong> pump operationup to 55 °C• Suitable as an extract <strong>air</strong> version <strong>with</strong> vents for regulated ventilation of up to200 m 2 living space• Integral immersion <strong>heat</strong>er (1.5 kW) for DHW temperatures up to 65 °CFor specification, see page 79


Domestic ventilationsystemsVitovent 300-FVitovent 300


64/65VITOVENT 300-FVITOVENT 300The Vitovent 300-F <strong>and</strong> Vitovent 300 domestic ventilation systems create a pleasant,healthy atmosphere in your room, <strong>with</strong>out wasting energy.Air quality makes a real difference to thequality of life inside the home. For thishowever, an adequate <strong>air</strong> change rate isessential. However, modern constructionpractices do not make this easy, as buildingsare designed to be as <strong>air</strong>tight as possible, toprevent <strong>heat</strong> loss. The Vitovent 300 ventilationsystem offers the solution, enabling apleasant, healthy climate in the room.Air is considered to be fresh when its CO 2concentration falls below 0.1 percent byvolume <strong>and</strong> it is free from odours. Peopleusually open the windows to allow fresh <strong>air</strong> in.However, window ventilation is not particularlyreliable. If windows are left open for toolong, <strong>heat</strong> is wasted; not long enough, <strong>and</strong>tiredness results. In contrast, the Vitovent 300domestic ventilation system continuouslyreplaces the <strong>air</strong> <strong>and</strong> removes odours <strong>and</strong>noxious substances. The result is a pleasant,healthy climate.Prevent mould, protect the building fabricOne of the main causes of mould growth ishumid indoor <strong>air</strong>. Mould can be unhealthyfor the occupants <strong>and</strong> will cause permanentdamage to the fabric of the building. From thispoint of view alone, investing in a domesticventilation system is cheaper than remedyingbuilding damage caused by fungal growth<strong>and</strong> mould.Allergy sufferers can breathe asigh of reliefThe Vitovent domestic ventilation systemsallow allergy sufferers to enjoy fresh <strong>air</strong> too.A filtration system, employing an effectivepollen filter, cleans the supply <strong>air</strong> of allergens<strong>and</strong> harmful substances. This reduces thegrowth <strong>and</strong> spread of mites <strong>and</strong> mouldfungus, creating an irritant-free environmenteven for allergy sufferers.Flat duct system for quick assemblyFor the Vitovent 300-F <strong>and</strong> Vitovent 300,alongside the already familiar accessories,the new, flexible, plastic flat duct systemcan be used, which is quick <strong>and</strong> easy toinstall. Its low height enables an integrationof this duct into ceiling/floor structures <strong>and</strong>can be subjected to mechanical loads. Theconventionally applied sealing <strong>with</strong> cold shrinktape is not required. The smooth anti-bacterialsurface coating ensures permanently hygienic<strong>air</strong> h<strong>and</strong>ling. A silencer is already integrated inthe distribution box.Air distribution boxFlat duct systemSupply <strong>air</strong>sectionPlastic flat duct system for a rapid <strong>and</strong>straightforward installationExtract <strong>air</strong>section


Domestic ventilationsystemsVitovent 300-FIdeally matched to compact Vitocal <strong>heat</strong> pumpsVitovent 300-FThe Vitovent 300-F domestic ventilationunit was developed for combination <strong>with</strong>a compact Vitocal <strong>air</strong> or brine <strong>heat</strong> pump.This enables the <strong>heat</strong> pump to be preciselyselected according to the required <strong>heat</strong> load.The <strong>heat</strong>ing output levels of the <strong>heat</strong> pumpsare between 3.0 to 10.6 kW (split <strong>heat</strong> pumps)or 5.9 to 10.3 kW (brine/water <strong>heat</strong> pumps).This makes the system suitable for livingareas of up to approx. 200 m 2 .The Vitovent 300-F ventilation unit isespecially suitable for new build, as allfunctions are possible in the smallestof spaces, such as ventilation <strong>and</strong> – inconjunction <strong>with</strong> a split Vitocal <strong>air</strong> source <strong>heat</strong>pump for example – <strong>heat</strong>ing, active cooling<strong>and</strong> DHW <strong>heat</strong>ing.It goes <strong>with</strong>out saying that the Vitovent 300-Fmeets the st<strong>and</strong>ards of the Passive HouseInstitute <strong>and</strong> has Passive House Certification.Up to 97 percent <strong>heat</strong> recoveryThe Vitovent 300-F ventilation unit claws backup to 97 percent of the latent <strong>heat</strong> in extract<strong>air</strong>, using it to <strong>heat</strong> the incoming outdoor <strong>air</strong>.High operating convenienceAll that is required for operation is an electricalconnection to the <strong>heat</strong> pump – all the settingsare made via the Vitotronic 200 <strong>heat</strong> pumpcontrol unit.Minimum space requirementThe space the unit requires is exceptionallysmall. Sited to the right or left of a Vitocal <strong>heat</strong>pump, a well matched unit is created whichtakes up just 0.68 m 2 installation area.2157463Vitovent 300-FDomestic ventilation system <strong>with</strong><strong>heat</strong> recovery1 Fan2 Extract <strong>air</strong> filter3 Supply <strong>air</strong> filter4 Heat exchanger5 Active filter monitoring6 Buffer cylinder (optional for passive house<strong>air</strong> tempering)7 Re<strong>heat</strong>er bank (optional for passive house<strong>air</strong> tempering)


66/67Vitovent 300-F domestic ventilation system <strong>with</strong>adjacent compact Vitocal <strong>heat</strong> pumpTake advantage of these benefits:• Combination <strong>with</strong> compact <strong>air</strong> <strong>and</strong> brine <strong>heat</strong> pumps• Small installation area thanks to direct connection <strong>with</strong>compact Vitocal <strong>heat</strong> pumps• Matching, integrated system <strong>with</strong> little space requirement• Flexible domestic ventilation system for low energy <strong>and</strong>passive houses• Up to 97 percent <strong>heat</strong> recovery from the stale <strong>air</strong>• Convenient control via Vitotronic 200 in the <strong>heat</strong> pump• Optional re<strong>heat</strong>er bank for <strong>air</strong> tempering in the passive house• Efficient DC motors keep power consumption low• Utilisation of the familiar Vitovent 300 range of accessories• Effective F7 pollen filter <strong>with</strong> active monitoring – beneficial forallergy sufferers• Optional use of a solar thermal system for DHW <strong>heat</strong>ing toreduce energy costsFor specification, see page 79


Domestic ventilationsystemsVitovent 300Ventilating virtually <strong>with</strong>out energy lossVitovent 300Energy saving is the trump card of theVitovent 300. The powerful <strong>heat</strong> exchangerrecovers more than 90 percent of the latent<strong>heat</strong> contained in the stale <strong>air</strong> <strong>and</strong> uses itto <strong>heat</strong> the incoming <strong>air</strong>. Thanks to the veryefficient DC motors, for each kilowatt hour ofelectrical energy expended, 15 times more<strong>heat</strong>ing energy is recovered. This means that300 litres of fuel oil could be saved in a yearfor a living area of 150 m 2 .Long term well-beingVitovent 300 constantly replaces the ambient<strong>air</strong> <strong>and</strong> simultaneously removes odours<strong>and</strong> noxious substances. The ventilationsystem can be conveniently controlled via aremote control.Relief at h<strong>and</strong> for allergy sufferersA filtration system, employing an effectivepollen filter (filter class F6), cleans the supply<strong>air</strong>. This allows allergy sufferers to enjoy fresh<strong>air</strong> too.Cooling <strong>with</strong> night <strong>air</strong>The Vitovent 300 domestic ventilationsystem (output stage 300 or 400 m 3 /h) <strong>with</strong>bypass circuit is highly versatile: in winter,<strong>heat</strong> recovered from the extract <strong>air</strong> is usedto temper the fresh <strong>air</strong>, <strong>and</strong> in summer, therooms are cooled by a temperature-controlledbypass of the <strong>heat</strong> recovery system using theintegral bypass damper.21314Vitovent 300Domestic ventilation system <strong>with</strong><strong>heat</strong> recovery1 DC fans2 Bypass damper3 Heat exchanger4 Air filter


68/69The Vitovent 300 provides a comfortable ambient climate all year round, reduces theventilation <strong>heat</strong> dem<strong>and</strong> <strong>and</strong> lowers the <strong>heat</strong>ing costs.Take advantage of these benefits:• Comfortable <strong>and</strong> healthy ambient climate• Low <strong>heat</strong>ing costs thanks to more than 90 percent <strong>heat</strong>recovery from the stale <strong>air</strong>• Integral, temperature-controlled bypass circumvents the <strong>heat</strong>recovery in summer <strong>and</strong> enables ventilation <strong>with</strong> cool night <strong>air</strong>• Economical DC motors <strong>with</strong> a constant flow rate <strong>and</strong> balancecontrol maintain a steady <strong>air</strong> flow, independent of thestatic pressure• Balanced humidity management prevents building damage• Effective filtration of the outdoor <strong>air</strong> – important forallergy sufferers• Reduces unpleasant odours from outside• Closed windows – improved security against burglary <strong>and</strong>protection against noiseFor specification, see page 79


SpecificationVitocal 350-G brine/water <strong>heat</strong> pumpVitocal 350-G Type BW 351.A07 BW 351.A18 BWC 351.A07Output data(to EN 14511, B0/W35 °C, 5 K spread)*Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeFlow temperatureDimensionsLengthWidthHeightkWkWkW°CmmmmmmWeight kg 135 322 145* In conjunction <strong>with</strong> a high efficiency pump7.35.81.594.672845600104918.714.84.144.572108578012677.35.81.594.6728456001049Vitocal 350-G water/water <strong>heat</strong> pump*Vitocal 350-G Type BW 351.A07 BW 351.A18 BWC 351.A07Output data(to EN 14511, W10/W35 °C, 5 K spread)**Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeFlow temperatureDimensionsLengthWidthHeightkWkWkW°Cmmmmmm10.38.71.706.1728456001049Weight kg 135 322 14525.721.44.65.6721085780126710.38.71.706.1728456001049* Brine/water <strong>heat</strong> pump <strong>with</strong> conversion kit (accessory) to convert to water/water <strong>heat</strong> pump** In conjunction <strong>with</strong> a high efficiency pumpVitocal 350-G <strong>heat</strong> pump as stage 2 (slave)Vitocal 350-G Type BWS 351.A07 BWS 351.A18Output data(to EN 14511, B0/W35 °C, 5 K spread)*Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeFlow temperatureDimensionsLengthWidthHeightkWkWkW°Cmmmmmm7.35.81.594.672845600104918.714.84.144.57210857801267Weight kg 135 322* In conjunction <strong>with</strong> a high efficiency pump


70/71Vitocal 343-G brine/water <strong>heat</strong> pumpVitocal 343-G Type BWT 341.A06 BWT 341.A08 BWT 341.A10Output data(to EN 14511, B0/W35 °C, 5 K spread)Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modekWkWkWDimensionsLength x width x height mm 680 x 600 x 2075Cylinder capacity litres 220 220 220N L performance factor 1.5 1.5 1.6Weight kg 260 260 2665.94.71.254.77.96.31.664.710.38.32.194.7Vitocal 333-G/Vitocal 333-G NC brine/water <strong>heat</strong> pumpVitocal 333-GVitocal 333-G NCOutput data(to EN 14511, B0/W35 °C, 5 K spread)Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeTypeTypekWkWkWBWT 331.A06BWT_NC 331.A065.94.71.254.7BWT 331.A08BWT_NC 331.A087.96.31.664.7BWT 331.A10BWT_NC 331.A10DimensionsLength x width x height mm 680 x 600 x 1830Cylinder capacity litres 170 170 170N L performance factor 1 1.1 1.3Weight kg 249 249 25610.38.32.194.7


SpecificationVitocal 300-G single stage brine/water <strong>heat</strong> pumpVitocal 300-GOutput data(to EN 14511, B0/W35 °C, 5 K spread)*Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeFlow temperatureTypeTypekWkWkW°CBW 301.A06BWC 301.A065.94.71.34.660BW 301.A08BWC 301.A087.86.21.654.760BW 301.A10BWC 301.A10DimensionsLength x width x height mm 845 x 600 x 1049Weight* In conjunction <strong>with</strong> a high efficiency pumpkgkg11312311712710.08.02.04.860129139BW 301.A13BWC 301.A1312.910.52.64.960135145BW 301.A17BWC 301.A1717.013.73.64.760148158Vitocal 300-G single stage water/water <strong>heat</strong> pump*Vitocal 300-GOutput data(to EN 14511, W10/W35 °C, 5 K spread)**Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeFlow temperatureTypeTypekWkWkW°CBW 301.A06BWC 301.A067.96.71.256.360BW 301.A08BWC 301.A0810.48.81.646.360BW 301.A10BWC 301.A1013.411.42.16.360DimensionsLength x width x height mm 845 x 600 x 1049Weightkgkg113123117127* Brine/water <strong>heat</strong> pump <strong>with</strong> conversion kit (accessory) to convert to water/water <strong>heat</strong> pump** In conjunction <strong>with</strong> a high efficiency pump129139BW 301.A13BWC 301.A1317.114.62.86.260135145BW 301.A17BWC 301.A1723.019.53.76.260148158Vitocal 300-G as stage 2 (slave)Vitocal 300-G Type BWS 301.A06 BWS 301.A08 BWS 301.A10 BWS 301.A13 BWS 301.A17Output data(to EN 14511, B0/W35 °C, 5 K spread)*Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeFlow temperaturekWkWkW°C5.94.71.34.6607.86.21.654.760DimensionsLength x width x height mm 845 x 600 x 104910.08.02.04.86012.910.52.64.96017.013.73.64.760Weight kg 108 112 124 130 143* In conjunction <strong>with</strong> a high efficiency pump


72/73Vitocal 300-G single stage brine/water <strong>heat</strong> pumpVitocal 300-G Type BW 301.A21 BW 301.A29 BW 301.A45Output data(to EN 14511, B0/W35 °C, 5 K spread)Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeFlow temperaturekWkWkW°C21.217.04.54.760DimensionsLength x width x height mm 1085 x 780 x 126728.823.36.04.86042.834.29.34.660Weight kg 282 305 345Vitocal 300-G single stage water/water <strong>heat</strong> pump*Vitocal 300-G Type BW 301.A21 BW 301.A29 BW 301.A45Output data(to EN 14511, W10/W35 °C, 5 K spread)Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeFlow temperaturekWkWkW°C28.123.74.75.960DimensionsLength x width x height mm 1085 x 780 x 126737.131.46.266058.948.910.75.560Weight kg 282 305 345* Brine/water <strong>heat</strong> pump <strong>with</strong> conversion kit (accessory) to convert to water/water <strong>heat</strong> pumpVitocal 300-G as stage 2 (slave)Vitocal 300-G Type BWS 301.A21 BWS 301.A29 BWS 301.A45Output data(to EN 14511, B0/W35 °C, 5 K spread)Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeFlow temperaturekWkWkW°C21.217.04.55.960DimensionsLength x width x height mm 1085 x 780 x 126728.823.36.066042.834.29.35.560Weight kg 277 300 340


SpecificationVitocal 300-G Pro brine/water <strong>heat</strong> pumpVitocal 300-G Pro Type BW 190 BW 1120 BW 2150 BW 2180 BW 2250Output data(to EN 14511, B0/W35 °C, 5 K spread)Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modekWkWkW9374.519.54.7712196.424.84.83150120.131.94.7182145.439.64.6240191.450.44.76DimensionsLengthWidthHeightmmmmmmWeight kg 720 820 1180 1240 1360Number of compressors pce 1 1 1 1 18801280156088012801560880192015608802520156088025201560Vitocal 300-W Pro water/water <strong>heat</strong> pumpVitocal 300-W Pro Type WW 1125 WW 1155 WW 2200 WW 2250 WW 2300Output data(to EN 14511, W10/W35 °C, 5 K spread)Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modekWkWkW12210320,95.8414512224,65.8919015932,15.9224019942,15.729024449,55.86DimensionsLengthWidthHeightmmmmmmWeight kg 720 820 1180 1240 1360Number of compressors pce 1 1 1 1 18801280156088012801560880192015608802520156088025201560


74/75Vitocal 242-G brine/water <strong>heat</strong> pumpVitocal 242-G Type BWT 241.A06 BWT 241.A08 BWT 241.A10Output data (to EN 14511, B0/W35 °C)Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modekWkWkWDimensionsLength x width x height mm 680 x 600 x 2075Cylinder capacity litres 220 220 220N L performance factor 1.5 1.5 1.6Weight kg 260 260 2665.94.61.404.27.76.01.844.210.07.82.324.3Vitocal 222-G brine/water <strong>heat</strong> pumpVitocal 222-G Type BWT 221.A06 BWT 221.A08 BWT 221.A10Output data (to EN 14511, B0/W35 °C)Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCoefficient of performance e in <strong>heat</strong>ing modekWkWkWDimensionsLength x width x height mm 680 x 600 x 1830Cylinder capacity litres 170 170 170N L performance factor 1 1.1 1.3Weight kg 250 250 2565.94.61.404.27.76.01.844.210.07.82.324.3Vitocal 200-G brine/water <strong>heat</strong> pumpVitocal 200-G Type BWC 201.A06 BWC 201.A08 BWC 201.A10 BWC 201.A13 BWC 201.A17Output data(to EN 14511, B0/W35 °C)Rated <strong>heat</strong>ing outputCooling capacityPower consumptionCOP e in <strong>heat</strong>ing modeFlow temperaturekWkWkW°C5.84.51.34.3607.66.01.744.460DimensionsLength x width x height mm 845 x 600 x 1049Weight kg 119 124 135 141 1549.77.72.24.46013.010.32.854.56017.213.73.814.560


SpecificationNatural cooling NC-BoxOutput dataCooling capacity subject to the <strong>heat</strong> pump outputfor Vitocal 343-G/333-G/300-G/242-G/222-G/200-G kW approx. 1.25 to 5.0DimensionsLength x width x height mm 520 x 580 x 420Weight <strong>with</strong>out mixer kg 25Weight <strong>with</strong> mixer kg 28Active cooling AC-BoxThe maximum cooling capacity is limited by the integral <strong>heat</strong> pump(for Vitocal 300-G).DimensionsLength x width x height mm 720 x 350 x 970Weight kg 80


76/77Vitocal 350-A <strong>air</strong>/water <strong>heat</strong> pumpVitocal 350-A Type AWHI 351.A10 AWHI 351.A14 AWHI 351.A20Output data (to EN 14511, A2/W35 °C)Rated <strong>heat</strong>ing outputPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeFlow temperatureDimensionsLength (depth)WidthHeightkWkW°CmmmmmmWeight kg 287 297 36110.63.03.665946880187014.54.23.5659461030187018.55.83.26594612001870For internal installationVitocal 350-A <strong>air</strong>/water <strong>heat</strong> pumpVitocal 350-A Type AWHO 351.A10 AWHO 351.A14 AWHO 351.A20Output data (to EN 14511, A2/W35 °C)Rated <strong>heat</strong>ing outputPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeFlow temperatureDimensionsLength (depth)WidthHeightkWkW°CmmmmmmWeight kg 325 335 40010.63.03.66512651380188514.54.23.56512651530188518.55.83.265126517001885For external installationVitocal 300-A <strong>air</strong>/water <strong>heat</strong> pumpVitocal 300-ATypeAWCI_AC 301.AInternal installationAWO-AC 301.AExternal installationAWO-AC 301.AExternal installation(silent version)Output data(to EN 14511, A2/W35 °C)Rated <strong>heat</strong>ing outputPower consumptionCoefficient of performance e in <strong>heat</strong>ing modeCoefficient of performance e A7/W35 °CCooling capacity A27/W7 °CkWkWkW3.0 – 9.02.33.94.48.63.0 – 9.02.33.94.48.63.0 – 9.02.33.94.48.6DimensionsLength x width x height mm 946 x 880 x 1870 946 x 880 x 1885 1265 x 1380 x 1885For internal installationWeight kg 289 279 309For external installation


SpecificationSplit compact <strong>air</strong>/water <strong>heat</strong> pumpsVitocal 242-S Type AWT-AC 241.A04 AWT-AC 241.A07 AWT-AC 241.A10 AWT-AC 241.A13<strong>Heating</strong> output data(to EN 14511, A2/W35 °C, 5 K spread)Rated <strong>heat</strong>ing outputCoefficient of performance e in <strong>heat</strong>ing mode<strong>Heating</strong> output rangeCooling capacity data(to EN 14511, A35/W7 °C, 5 K spread)Rated cooling capacityEnergy efficiency ratio e in cooling modeCooling capacity rangekWkW3.03.271.1 – 3.85.63.241.3 – 7.77.73.54.4 – 9.910.63.265.0 – 11.9kWkW3.22.961.2 – 3.86.22.61.6 – 8.07.42.752.4 – 8.59.12.502.4 – 10.0Cylinder capacity l 220 220 220 220Dimensions, internal unitLength (depth) x width x height mm 680 x 600 x 2075Dimensions, external unitLength (depth)WidthHeightWeightInternal unitExternal unitmmmmmmkgkg2908696102044334010408652046634090012552071103409001255207110Vitocal 222-S Type AWT-AC 221.A04 AWT-AC 221.A07 AWT-AC 221.A10 AWT-AC 221.A13<strong>Heating</strong> output data(to EN 14511, A2/W35 °C, 5 K spread)Rated <strong>heat</strong>ing outputCoefficient of performance e in <strong>heat</strong>ing mode<strong>Heating</strong> output rangeCooling capacity data(to EN 14511, A35/W7 °C, 5 K spread)Rated cooling capacityEnergy efficiency ratio e in cooling modeCooling capacity rangekWkW3.03.271.1 – 3.85.63.241.3 – 7.77.73.54.4 – 9.910.63.265.0 – 11.9kWkW3.22.961.2 – 3.86.22.61.6 – 8.07.42.752.4 – 8.59.12.502.4 – 10.0Cylinder capacity l 170 170 170 170Dimensions, internal unitLength (depth) x width x height mm 680 x 600 x 1830Dimensions, external unitLength (depth)WidthHeightWeightInternal unitExternal unitmmmmmmkgkg2908696101944334010408651946634090012551971103409001255197110Vitocal 200-STypeType<strong>Heating</strong> output data(to EN 14511, A2/W35 °C, 5 K spread)Rated <strong>heat</strong>ing outputkWCoefficient of performance e in <strong>heat</strong>ing mode<strong>Heating</strong> output rangekWCooling capacity data(to EN 14511, A35/W7 °C, 5 K spread)Rated cooling capacitykWEnergy efficiency ratio e in cooling modeCooling capacity rangekWAWB 201.B04AWB-AC 201.B043.03.271.1 – 3.83.22.961.2 – 3.8AWB 201.B07AWB-AC 201.B075.63.241.3 – 7.76.22.61.6 – 8.0Dimensions, internal unitLength (depth) x width x height mm 360 x 450 x 905Dimensions, external unitLength (depth)WidthHeightWeightExternal unitInternal unit AWBInternal unit AWB-ACmmmmmmkgkgkg2908696104334383401040865663438AWB 201.B10AWB-AC 201.B107.73.54.4 – 9.97.42.752.4 – 8.534090012551103742AWB 201.B13AWB-AC 201.B1310.63.265.0 – 11.99.12.502.4 – 10.034090012551103742


78/79Vitocal 160-A DHW <strong>heat</strong> pumpOutput during DHW <strong>heat</strong>ing from 15 to 45 °C <strong>and</strong> 15 °C <strong>air</strong> temperature kW 1.5Power consumption kW 0.43Coefficient of performance e (COP) 3.56Air flow rate m 3 /h 250Power consumption of immersion <strong>heat</strong>er kW 1.50Cylinder capacity litres 285Weight type WWK/type WWKS kg 105/110DimensionsLength ø x width x height (recirculation <strong>air</strong> mode)Height (extract <strong>air</strong> mode)mmmm660 x 700 x 18461838Domestic ventilation systemsVitovent 300-F m 3 /h 285Air flow rateMaximum <strong>air</strong> flow rate under pressurem 3 /hm 3 /h/Pa80 – 285280/170Dimensions excluding connectorsLength (depth) x width x height mm 680 x 400 x 1468Weight kg 80Filter DIN EN 779Outdoor <strong>air</strong>Extract <strong>air</strong>Filter classFilter classCountercurrent <strong>heat</strong> exchangerHeat recovery level up to % 97F7G4Vitovent 300 m 3 /h 180 300 400Air flow rateMaximum <strong>air</strong> flow rate under pressurem 3 /hm 3 /h/Pa50 to 180180/15050 to 300300/10050 to 400400/100Dimensions excluding connectorsLength (depth) x width x height mm 310 x 560 x 600 436 x 675 x 747 436 x 675 x 747Weight kg 25 31 32Filter DIN EN 779Outdoor <strong>air</strong>Extract <strong>air</strong>Filter classFilter classCountercurrent <strong>heat</strong> exchangerHeat recovery level up to % 92 91 91Automatic bypass No Yes YesSummer cassette Yes No NoDigital remote control <strong>with</strong> weekly program Yes Yes YesF6G4F6G4F6G4


System technology80/81A perfect match – system technologyThe convenient controls <strong>and</strong> perfectly matched <strong>Viessmann</strong> system technologyoffer the user maximum reliability, flexibility <strong>and</strong> efficiency.<strong>Viessmann</strong> does not simply supply users of its<strong>heat</strong>ing systems <strong>with</strong> individual componentsthat meet high st<strong>and</strong>ards of quality <strong>and</strong>reliability. The same high st<strong>and</strong>ards also applyto <strong>Viessmann</strong> system technology, where allcomponents fit together perfectly.<strong>Viessmann</strong> system technology includesthe knowledge of what it takes to make areliable <strong>and</strong> economical <strong>heat</strong>ing system,namely the Vitotronic <strong>heat</strong> pump control unit<strong>with</strong> wireless remote control <strong>and</strong> the highlycapable Vitocell DHW cylinders for optimumDHW convenience.Domestic hot waterDHW conveniencefor every dem<strong>and</strong> – theVitocell range of cylindersoffers an enormousselection <strong>and</strong> allows greatflexibility in the designPage 82Control convenienceClear, convenient,intelligent – the Vitotronicoffers you perfectfunctionality for fast <strong>and</strong>precise control over your<strong>heat</strong>ing system.Page 84Data communicationDo you know aboutVitocom?It is the ideal solution forcontrolling the <strong>heat</strong> pumpsystem remotely, <strong>and</strong>exchanging data easily<strong>and</strong> conveniently from adifferent location.Page 86


System technologyDomestic hot waterThe Vitocell range from<strong>Viessmann</strong> offers the rightDHW cylinder for everyaspiration.DHW convenience for every dem<strong>and</strong>With its Vitocell DHW cylinders, <strong>Viessmann</strong> offers a convenient solution for hot watersupply – the perfect extension to a new <strong>heat</strong> pump.The dem<strong>and</strong> for hot water is completelydifferent in every household. One factor isthe number of residents <strong>and</strong> another is theirbathing <strong>and</strong> showering habits. For example,it is often the case that several people in onehousehold leave for work <strong>and</strong> school at thesame time, so lots of hot water needs to becontinuously available for the shower in ashort space of time. Those who prefer a bathwill also want to have enough warm waterto fill the tub. Similarly, a DHW cylinder inan apartment building should be able todeliver a sufficient supply if hot water isdrawn from more than one outlet at the sametime. The Vitocell DHW cylinders fulfil theserequirements in every respect <strong>and</strong> are alsorobust enough to cope <strong>with</strong> constant dem<strong>and</strong>.


82/83Optimally matched for use <strong>with</strong><strong>heat</strong> pumps<strong>Viessmann</strong> system solutions from one singlesource make optimum use of the energycaptured by a <strong>heat</strong> pump. For example, thereare suitable DHW cylinders especially for <strong>heat</strong>pumps, that are specifically designed for therequirements of detached <strong>and</strong> two-familyhomes when using a Vitocal 350, 300 or 200.DHW convenience that's as individualas you areSome DHW cylinders are prepared for theconnection of a solar thermal system or theinstallation of one or two additional electric<strong>heat</strong>ers <strong>with</strong> up to 6 kW output for boostingthe DHW temperature.Strong inner values<strong>Viessmann</strong>'s product range includes theVitocell 300 <strong>and</strong> Vitocell 100 product groups.All Vitocell 300 cylinders are made of stainlesssteel <strong>and</strong> meet the most stringent hygienerequirements. It is no coincidence thatstainless steel is also used for its anti‐bacterialproperties in the food processing industry, inkitchens <strong>and</strong> in hospitals.Squeaky clean: The Vitocell 300DHW cylinders are made ofstainless steel – a materialthat meets the highesthygiene st<strong>and</strong>ards.Alternatively, the inner surfaces of theVitocell 100 are lastingly protected againstcorrosion <strong>with</strong> the proven Ceraprotect enamelcoating. All DHW cylinders are fully equipped<strong>with</strong> high grade insulation against <strong>heat</strong> loss.Internal indirect coils, drawn low down tothe cylinder floor, enable quick <strong>and</strong> energyefficient <strong>heat</strong>ing of the entire cylinder content.<strong>Viessmann</strong> DHW cylinder Vitocell 100-V:Perfectly designed for use <strong>with</strong> <strong>heat</strong> pumps


System technologyControl convenienceVitotronic control units, <strong>with</strong> their well thought-out electronicmanagement system, ensure the economical <strong>and</strong> safeoperation of your <strong>Viessmann</strong> <strong>heat</strong>ing system.


84/85Vitotronic – everything perfectly under controlWith the Vitotronic control unit, operating your <strong>Viessmann</strong> <strong>heat</strong> pump is as simple asmaking a phone call.Vitotronic – technology that thinks for youVitotronic control units provide you <strong>with</strong> everyopportunity for really convenient <strong>heat</strong>ing,regulated to suit you personally. Onceadjusted to your needs, the Vitotronic runsmany functions automatically <strong>and</strong> saves agreat deal of energy. Individual adjustmentsare simplified by the clear Vitotronic userinterface <strong>with</strong> backlit keys <strong>and</strong> large displayshowing plain text messages.Options for the futureThe Vitotronic control unit is designed toaccommodate future modifications. Whetheryou want to build an extension in the nearfuture, or extend your <strong>heat</strong>ing system <strong>with</strong>a solar thermal system, the Vitotronic willalways keep up <strong>with</strong> the times.Saving energy made easyThe Vitotronic automatically changes overbetween winter <strong>and</strong> summertime, <strong>and</strong>responds to outside temperature fluctuationsas a weather-compensated control unit. Allconvenience functions, such as the partybutton which cancels the energy savingnight setback, <strong>and</strong> the economy <strong>and</strong> holidayprograms, can be called up quickly <strong>and</strong> easilyat the touch of a button, either on the <strong>heat</strong>pump itself, or by using the optional remotecontrol from your living space, which has anidentical user interface.The Vitotrol 300 is a convenient remote control unitto control your <strong>heat</strong> pump from any room in yourapartment or house.


System technologyData communicationVitotrol app for iPhone, iPad <strong>and</strong> iPod-Touch to control the<strong>heat</strong> pump system from any location


86/87Everything under control – from wherever you areMake use of the unique, convenient TeleControl program from <strong>Viessmann</strong> to regulate your<strong>heat</strong>ing system. Naturally wireless <strong>and</strong> digital.<strong>Viessmann</strong> TeleControl offers an efficientsolution for all <strong>heat</strong>ing systems, every type ofenergy <strong>and</strong> all applications. With the Vitotrolapp, Vitocom, Vitodata <strong>and</strong> Vitohome, our<strong>heat</strong>ing systems can be fully monitored <strong>and</strong>controlled from anywhere you are.You communicate directly <strong>with</strong> the Vitotroniccontrol unit, which can be matched to yourindividual requirements. This increasesconvenience, improves security <strong>and</strong>additionally saves energy. Thanks to remotediagnosis, your <strong>heat</strong>ing contractor can ensurereliable <strong>heat</strong>ing operation.Vitotrol appThe Vitotrol app for controlling <strong>heat</strong>ingsystems is available for iPhone, iPad <strong>and</strong> iPodtouch. To enable this, the Vitotronic must beextended by the Vitocom 100 LAN interface<strong>and</strong> must be connected to the DSL routeron site. A configuration of the DSL routeris not required. Heat pump messages aresent to the iPhone. The Vitotrol app allowsyou to control up to three <strong>heat</strong>ing circuits,making it a convenient tool for operating your<strong>heat</strong>ing system.Vitocom 100Vitocom 100 is the easy way to remotelymonitor <strong>and</strong> control the <strong>heat</strong> pump via yourmobile phone <strong>and</strong> is ideal for detached <strong>and</strong>two-family houses. It's also suitable forholiday <strong>and</strong> weekend homes that are notoccupied all the time. On your way, start upthe <strong>heat</strong> pump via your mobile phone, soyou can arrive in a cosily warm home, just asyou like it. It could hardly be any simpler ormore economical.Vitocom 200 <strong>and</strong> Vitodata 100If you want to combine the highest levels ofconvenience <strong>and</strong> security, the Vitocom 200 isthe right solution. This attractively priced versionoffers ideal conditions for comprehensive datacommunication – perfect for private homes<strong>and</strong> smaller commercial buildings, such asworkshops or clinics. A st<strong>and</strong>ard PC or laptopare required.


Accessories88/89System accessories from <strong>Viessmann</strong> – complete<strong>heat</strong>ing systems from a single sourceAll products in the Vitoset range come from a single source ensuring that your <strong>heat</strong>ingsystem operates <strong>with</strong> complete reliability.Every Vitoset product meets the high qualityst<strong>and</strong>ards that are typical for <strong>Viessmann</strong>.Why settle for anything less? The rangeof accessories works perfectly <strong>with</strong> allother <strong>Viessmann</strong> <strong>heat</strong>ing systems. Here isan overview:to the <strong>heat</strong>ing system, the bathroom radiatorscan also be operated electrically. It's evenpossible to combine both techniques, i.e.using the central <strong>heat</strong>ing connection for the<strong>heat</strong>ing season, <strong>and</strong> the <strong>heat</strong>er rod for coolersummer days.Universal radiatorsThe quality of radiators is characterisedby the high grade, long lasting paint finish.Thanks to their neutral finish in whiteRAL 9016, <strong>Viessmann</strong> universal radiatorswill suit the decor of any room. On request,all universal radiators can also be supplied inspecial colours.Panel radiatorsTheir brilliant, smooth design makesthese flat panel radiators an exceptionallyaesthetic design feature, which is subtleyet effective. The technical concept behindthem is optimised for the dem<strong>and</strong>s of energyefficient <strong>heat</strong>ing. The resistant, plastic-coatedsurface is easy to clean <strong>and</strong> gleams in whiteRAL 9016.Underfloor <strong>heat</strong>ing systemsEnergy efficient, safe, convenient Vitosetunderfloor <strong>heat</strong>ing systems from <strong>Viessmann</strong>provide an extremely pleasant ambience dueto the even transfer of <strong>heat</strong> throughout theroom. Furthermore, <strong>Viessmann</strong> has designedthe control technology especially for <strong>heat</strong>pumps, regulating both <strong>heat</strong>ing <strong>and</strong> coolingoperation in summer.Ultra-low temperature radiatorsUltra-low temperature radiators are especiallysuitable for allowing <strong>heat</strong> pumps to be usedefficiently in radiator systems. The effective<strong>heat</strong> distribution through activators enableslow flow temperatures.Bathroom radiatorsThese innovative Vitoset bathroom radiators<strong>with</strong> their slender pipe elements look elegant<strong>and</strong> light. They will help you to make yourbathroom stylish, <strong>and</strong> will keep your towelsnice <strong>and</strong> warm. Alongside their connectionBeautifully finished <strong>and</strong> pleasing to the eye: Bathroomradiators come in many different sizes <strong>and</strong> colours. Theyalso make a stylish design statement.


Service for everyaspect of <strong>heat</strong>ing<strong>Viessmann</strong> trade partners


90/91With our trade partners, you're in good h<strong>and</strong>sAt <strong>Viessmann</strong>, proximity to trade partners is the basis of the company's success.Everyone can benefit from their expertise by choosing a new <strong>Viessmann</strong> <strong>heat</strong> pump.Property developers <strong>and</strong> system userscan receive advice, sales, installation<strong>and</strong> customer service exclusively via<strong>Viessmann</strong> trade partners, who receiveregular training at the <strong>Viessmann</strong> Academy,<strong>and</strong> have an in‐depth knowledge of thecompany's products.Every system user benefits from thecomprehensive service that all installationcontractors offer as st<strong>and</strong>ard.Affordable finance, economical <strong>heat</strong>ingHere are some financial terms <strong>and</strong>conditions to shout about: <strong>Viessmann</strong> <strong>and</strong>CreditPlus Bank have some winning financialdeals to support you if you are updating anexisting system. A new <strong>heat</strong> pump can befinanced for just 3.99 % effective APR. Thismeans you generally save much more on<strong>heat</strong>ing costs than you spend on finance.For detailed information, please contact yourlocal contractor.Some service examples:• Free, no-obligation <strong>and</strong> individual advice,even on site• Clear calculation of <strong>heat</strong>ing cost savingsthrough the installation of a <strong>heat</strong> pump,even in combination <strong>with</strong> solar collectors• Calculation of the payback period, afterwhich the new <strong>heat</strong> pump will have paidfor itself through energy savings• Calculation of the actual <strong>heat</strong> <strong>and</strong> DHWdem<strong>and</strong> for a household or property• Complete solution <strong>with</strong> everything froma single source – including <strong>geothermal</strong>probe drilling• Support when applying for subsidieswww.viessmann.de/foerdermittelThe government is rewarding environmentallyresponsible <strong>heat</strong>ing. Current informationcan be found on the internet atwww.viessmann.de/foerdermittel. Thisinformation is constantly being updated <strong>and</strong>can offer an initial overview before consultinga contractor.


Contacts <strong>and</strong>further information<strong>Viessmann</strong> online offers detailed information about products,subsidy opportunities <strong>and</strong> services.Always there for youAs a globally active family business, <strong>Viessmann</strong> is involved in constant dialogue<strong>with</strong> its trade partners <strong>and</strong> system users.<strong>Viessmann</strong> trade partners are local,competent <strong>and</strong> committed contacts forinvestors, property developers <strong>and</strong> systemusers – they are always pleased to offer thenecessary support for all questions relating to<strong>heat</strong>ing systems <strong>and</strong> modernisation projects.In personal consultations, the best solutionsfor an efficient <strong>heat</strong>ing system are soughtfrom the <strong>Viessmann</strong> comprehensive range.<strong>Viessmann</strong> onlineA great deal of further information on<strong>Viessmann</strong> products <strong>and</strong> services can befound at www.viessmann.de.


92/93www.viessmann.deQuick help via the internetDo you have questions about <strong>Viessmann</strong>products or on the subject of <strong>heat</strong>ing?At www.viessmann.de, you can findcomprehensive information round the clockon all <strong>Viessmann</strong> <strong>heat</strong>ing systems <strong>and</strong> theiroutput levels, a technical glossary, an energysavings check <strong>and</strong> much more.Subsidy programmesFor current information regarding subsidies forenvironmentally responsible <strong>heat</strong>ing systemsfrom <strong>Viessmann</strong>, visit www.viessmann.de.Of course, individual <strong>and</strong> competent advicecan also be obtained from all <strong>Viessmann</strong>sales offices or directly from your<strong>heat</strong>ing contractor.Your local contactIt is extremely easy to find local <strong>Viessmann</strong><strong>heat</strong>ing contractors using the quick searchfunction at www.viessmann.de.Simply click on "Partner vor Ort" to show<strong>heat</strong>ing contractors in the local area.


The comprehensive <strong>Viessmann</strong> product rangeBoilers for oilup to 116 MW <strong>heat</strong>ingor 120 t/h steam outputBoilers for gasup to 116 MW <strong>heat</strong>ingor 120 t/h steam outputSolar thermalsystems <strong>and</strong>photovoltaicsDetached housesApartment buildingsCommerce / IndustryLocal <strong>heat</strong>ing networksIndividual solutions <strong>with</strong> efficient systemsThe comprehensive <strong>Viessmann</strong>product rangeThe comprehensive product range from<strong>Viessmann</strong> offers individual solutions <strong>with</strong>efficient systems for all applications <strong>and</strong> allenergy sources. For decades, the companyhas been supplying highly efficient <strong>and</strong> clean<strong>heat</strong>ing systems for oil <strong>and</strong> gas, as wellas solar thermal systems along <strong>with</strong> <strong>heat</strong>generators for sustainable fuels <strong>and</strong> <strong>heat</strong>pumps.The comprehensive product range from<strong>Viessmann</strong> offers top technology <strong>and</strong> setsnew benchmarks. With its high energyefficiency, this range helps to save <strong>heat</strong>ingcosts <strong>and</strong> is always the right choice whereecology is concerned.Individual <strong>and</strong> economical<strong>Viessmann</strong> offers the right <strong>heat</strong>ing system forany dem<strong>and</strong> – wall mounted or floorst<strong>and</strong>ing,in individual combinations – all are futureproof<strong>and</strong> economical. And whether for detachedhouses or two-family homes, large residentialbuildings, commercial/industrial use or forlocal <strong>heat</strong>ing networks; for modernisingexisting properties or new build – they arealways the right choice.Key performersThe <strong>Viessmann</strong> Group sets the technologicalpace for the <strong>heat</strong>ing industry. This is what the<strong>Viessmann</strong> name represents, <strong>and</strong> also whatthe names of the subsidiaries in the Grouprepresent, as they are founded on the samepioneering spirit <strong>and</strong> power of innovation.


94/95Wood combustiontechnology, CHP <strong>and</strong>biogas productionup to 50 MWHeat pumps forbrine, water <strong>and</strong> <strong>air</strong>up to 2 MWAir conditioningtechnology<strong>Heating</strong> systemaccessoriesThe comprehensive product range from <strong>Viessmann</strong>:Individual solutions <strong>with</strong> efficient systems for all energysources <strong>and</strong> applicationsThe product range for all fuel types <strong>and</strong>output ranges:• Boilers for oil or gas up to 116 MW <strong>heat</strong>ingor 120 t/h steam output• Solar thermal systems• Photovoltaics• Heat pumps up to 2 MW• Wood combustion systems up to 50 MW• Combined <strong>heat</strong> <strong>and</strong> power modules up to<strong>Viessmann</strong> is highly specialised in all thesemarket segments, yet at the same timethe company has a crucial advantage overspecialist suppliers: <strong>Viessmann</strong> underst<strong>and</strong>s<strong>heat</strong>ing technology as a systematic whole <strong>and</strong>offers unbiased advice on technology <strong>and</strong> fueltype. This guarantees the best solution forevery application.30 MW el• Systems for the production of biogas from18 kW elto 20 MW gas• Biogas upgrading plants up to 3000 m 3 /h• Air conditioning technology• <strong>Heating</strong> system accessories


The comprehensive <strong>Viessmann</strong> product rangeDetached houses Apartment buildings Commerce / Industry Local <strong>heat</strong>ing networksOil boilersArchitect's own home,Bad Füssing, GermanyResidential development, Zi WeiGarden Xi'an, ChinaAmeco A380 Hangar Beijing,ChinaEuropean Parliament, Strasbourg,FranceGas boilersDetached house, Kevelaer,Germany"Wohnoase" residential park inRegensburg, GermanyPorsche Leipzig,GermanyEuropean Parliament, Brussels,BelgiumSolar thermalsystems <strong>and</strong>photovoltaicsHeliotrop Freiburg,GermanyHafenCity, Hamburg,GermanyCity of Tomorrow, Malmö,SwedenThe Palm Jumeirah,DubaiWood combustiontechnology, CHP, <strong>and</strong>biogas productionDetached house, Wiesloch,GermanyHotel Lagorai Cavalese,ItalyCongressional Centre,Brunstad, NorwayMonastery, St. Ottilien,GermanyHeat pumps forbrine, water <strong>and</strong> <strong>air</strong>Loftcube Regional GardenShow, Neu-Ulm, GermanyStudio flats, Br<strong>and</strong>enburg,GermanyUniversity library, Bamberg,GermanyResidential estate, Pfäffikon,Switzerl<strong>and</strong>The comprehensive product range from <strong>Viessmann</strong>: Individual solutions<strong>with</strong> efficient systems for all energy sources <strong>and</strong> applications


96/97Futureproof <strong>heat</strong>ing technology forall requirementsEnergy consumption worldwide has doubledsince 1970 <strong>and</strong> will triple by 2030. The result:The fossil fuels, oil <strong>and</strong> gas, are dwindling,energy prices are on the rise <strong>and</strong> excessiveCO 2emissions continue to affect ourenvironment. Energy efficiency is a must if wewant our future to be secure.In these projects, <strong>Viessmann</strong> again <strong>and</strong>again faces up to the most varied challengesto supply efficient <strong>heat</strong>ing technology byoffering innovative solutions – in historicallisted buildings as well as in modern industrialcomplexes <strong>and</strong> the large-scale residential <strong>and</strong>industrial arena.In almost every industrial nation, supplying<strong>heat</strong> to residential <strong>and</strong> commercial buildingsaccounts for the largest share of energyconsumption – consequently it also offers thegreatest savings potential. Advanced efficient<strong>heat</strong>ing systems from <strong>Viessmann</strong> are in usearound the world, not only in many privatehouseholds, but also in numerous majorinternational projects, where they make asizeable contribution to the efficient use ofenergy resources.City of Tomorrow, Malmö, Sweden


The company


98/99<strong>Viessmann</strong> – climate of innovation<strong>Viessmann</strong> is one of the leading internationalmanufacturers of <strong>heat</strong>ing systems <strong>and</strong>, <strong>with</strong>its comprehensive product range, offersindividually tailored, efficient systems for allapplications <strong>and</strong> types of fuel.As a third generation family run business,<strong>Viessmann</strong> has been supplying highly efficient<strong>and</strong> clean <strong>heat</strong>ing systems for many decades.A strong br<strong>and</strong> creates trustTogether <strong>with</strong> our br<strong>and</strong> label, our key br<strong>and</strong>message is an identifying feature throughoutthe world. „Climate of innovation“ is apromise on three levels: It is a commitment toa culture of innovation. It is also a promise ofenhanced product benefits <strong>and</strong>, at the sametime, an obligation to protect the environment.satisfied <strong>with</strong>out compromising the qualityof life for the generations to come.We consider climate protection,environmental responsibility <strong>and</strong> resourceefficiency to be key priorities throughoutour company, which has more than 9600employees globally.Efficiency PlusWith the strategic „Efficiency Plus“sustainability project, launched in 2005,<strong>Viessmann</strong> demonstrates at its own site inAllendorf (Eder) that the political goals set for2050 <strong>with</strong> regard to energy <strong>and</strong> climate canalready be achieved today <strong>with</strong> commerciallyavailable technology. In 2012, we will alreadyachieve the following results:Deutschl<strong>and</strong>s nachhaltigsteProduktion 2009Deutschl<strong>and</strong>s nachhaltigsteMarke 2011<strong>Viessmann</strong> was awarded theGerman Sustainability Prize for the"most sustainable production 2009"<strong>and</strong> as being the "most sustainablebr<strong>and</strong> 2011".Acting in a sustainable mannerFor <strong>Viessmann</strong>, taking responsibility signifiesa commitment to acting sustainably.This means bringing ecology, economy <strong>and</strong>social responsibility into harmony <strong>with</strong> eachother, ensuring that current needs are<strong>Viessmann</strong> Group• Consumption of fossil fuels reduced by 66percent compared to 2005• Use of renewables increased to 56 percent• CO 2emissions reduced by 80 percentcompared to 2005The long term goal is to cover all thecompany‘s <strong>heat</strong>ing energy requirementsourselves.For the particularly efficient utilisationof energy through the innovative <strong>heat</strong>recovery centre at the company'smain site in Allendorf/Eder,<strong>Viessmann</strong> was rewarded <strong>with</strong> theEnergy Efficiency Award 2010.Company details• Established in: 1917• Employees: 9600• Group turnover: €1.86 billion• Export share: 55 percent• 24 manufacturing plants in 11 countries• Sales companies <strong>and</strong> representationsin 74 countries• 120 sales outlets worldwideComprehensive range of products from<strong>Viessmann</strong> for every type of fuel <strong>and</strong> alloutput ranges• Boilers for oil <strong>and</strong> gas• Solar thermal systems• Photovoltaics• Heat pumps• Wood combustion systems• Combined <strong>heat</strong> <strong>and</strong> power• Biogas production plants• Biogas upgrading plants• Air conditioning• <strong>Heating</strong> system accessories


The <strong>Viessmann</strong> GroupD-35107 Allendorf (Eder)Telephone +49 (0)6452 70-0Fax +49 (0)6452 70-2780www.viessmann.comYour <strong>heat</strong>ing contractor:9449 593 - 5 GB 06/2012Copyright <strong>Viessmann</strong>.Duplication <strong>and</strong> alternative use only <strong>with</strong> prior written consent.Subject to technical modifications.