13.07.2015 Views

Test Report Thermal Imaging PV Module ... - PHOTON Info

Test Report Thermal Imaging PV Module ... - PHOTON Info

Test Report Thermal Imaging PV Module ... - PHOTON Info

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Test</strong> <strong>Report</strong><strong>Thermal</strong> <strong>Imaging</strong> <strong>PV</strong> <strong>Module</strong><strong>Test</strong> Item 1234Protocol-No. 123458Customer DataCustomer:<strong>PHOTON</strong> Europe GmbHJülicher Straße 37652070 AachenGermanyDate: 10/10/2010<strong>Module</strong> ParametersData by customerData by Photon<strong>Test</strong> item: 1234Manufacturer: Sample<strong>Module</strong> type: SampleSerial number: 1234567890Dimensions:1655 x 992 x 45 mmWeight:22.5 kgCell technology: poly-crystalline-SiSeries Cells: 60Parallel Cells: 1Measurement ParametersPower supply:<strong>Thermal</strong> imaging system:Current feed:Exposure time:Operator:Progammable DC Power Supply GEN 150-22 3.3 kWInfratec VarioCAM hr head17.27 A @ 44.2 V1 minuteDr. Andreas RosenbergerPage 4/5


Terms of use<strong>PHOTON</strong> Laboratory GmbH, Juelicher Strasse 376, 52070 Aachen, GermanyUsing the test reportThe test report is protected by copyrights. The test report may be published under the followingconditions.1. The test report may only be reproduced in its original, complete form, i.e. it is forbidden to change,alter, add, or remove elements of the report for the purpose of publication or circulation to a third party,nor is it allowed to circulate just a portion of the test report to a third party.2. It is forbidden to share a version of the test report that consists of wording or interpretations madeby the ordering party that deviate from that in the test report.3. When circulating the test report to a third party, readers should be able to recognize immediatelyand clearly that this document is a test report from <strong>PHOTON</strong> Laboratory GmbH. Furthermore, the testdate in the report should be visible. The following wording should be used when making this reference:“The test report was produced by <strong>PHOTON</strong> Laboratory GmbH on 10/10/2010 under the log number123458”4. It is forbidden to publish the test report for the purpose of advertising purposes if the manufacturerhas altered product characteristics mentioned in the report after the date of the test.5. When sharing the test report, or referring to the test report, references should only be made to thetest subject identified by serial number. It is forbidden to use, directly or indirectly, the test report torefer to all products in a product series.6. <strong>PHOTON</strong>’s logo is copyrighted and trademark protected. The logo may only be reproduced as partof the complete test report with written approval from <strong>PHOTON</strong> Laboratory GmbH.Page 5/5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!