200 <strong>Watt</strong> Termination <strong>and</strong> MismatchModel Impedance Frequency Range VSWR(maximum)50T-338-XXX*Referencedto 50 OhmsDC-3000 MHz (1.0:1)DC-2500 MHz (1.1:1 thru 1.2:1)DC-2000 MHz (1.3:1 thru 3.0:1)DC-1000 MHz (3.1:1 thru 10.0:1)1.15:1 (termination i.e. 1.0:1)± 5% DC-1000 MHz± 10% 1000-2500 MHz(all mismatch values)Input Power200 <strong>Watt</strong>s average @ +25º CDerate to 50 <strong>Watt</strong>s average @ +70º CPeak PowerOperatingTemperatureRF Connectors1000 <strong>Watt</strong>s (1 microsecond pulse) -55º C to +100º C N or 7/16 male or female*Insert VSWR required (1.0:1, 1.2:1, 1.3:1, 1.5:1, 1.6:1, 1.7:1, 1.8:1, 1.9:1, 2.0:1, 2.5:1, 3.0:1, 5.0:1, 10.0:1). Other VSWR available upon request.(Termination = 50T-338-1.0) (1.5:1 Mismatch = 50T-338-1.5) (5.0:1 Mismatch = 50T-338-5.0)This catalog represents less than 5% of our products. For your application, contact us at sales@jfwindustries.com5-13