13.07.2015 Views

Dynacalibrator® Model 150 Calibration Gas Generator ... - Interchim

Dynacalibrator® Model 150 Calibration Gas Generator ... - Interchim

Dynacalibrator® Model 150 Calibration Gas Generator ... - Interchim

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

AnalyticalComponentsSystems&VICI Metronics Inc.Dynacalibrator ® <strong>Model</strong> <strong>150</strong><strong>Calibration</strong> <strong>Gas</strong> <strong>Generator</strong>PPB to high PPM rangeTemperature control with an accuracyof ±0.01°CEconomical, flexible alternative tobulky bottled gas mixturesDescriptionThe Dynacalibrator ® <strong>Model</strong> <strong>150</strong> is a constant temperaturesystem designed to generate precise ppm or ppb concentrationsof chemical compounds in a gas stream, usingpermeation devices as the trace gas source. It is used asa reference for the calibration of instruments in the field ofgas chromatography, verifying the accuracy of analyticaldata generated from air pollution monitoring, industrialhygiene surveys, odor survey programs, and tracer studies,and in other instruments that measure gas concentrations.A passivated glass-coated permeation chamber housesthe permeation device(s), with measured inert carrier gassweeping the calibration gas/vapor from the chamber. Adigital temperature controller maintains the chambertemperature at a set point with an accuracy of ±0.01°C,traceable to NIST standards. The wide range of temperaturesettings (5°C above ambient to 110°C) allows the end userto generate a wide range of volumetric concentrations forboth low and high vapor pressure chemical compounds,establishing or changing the desired volumetricconcentration by simply varying the carrier flow.PASSIVATEDGLASS-COATEDSS LINEToinstrumentOUTLETCarrier gassourceINLETDEDICATED SWITCHED-MODETEMPERATURE CONTROLLER055(front panel)PASSIVATEDGLASS-COATED SSPERMEATIONCHAMBERAdvantages Over Bottled StandardsPermeation devices from VICIMetronics offer severalkey advantages overcylinder-supplied gascalibration standards.Economy is always amajor consideration;customers who havedone the arithmetic, factoringin the cost of cylinderpurchase, shipment, anddisposal, typically discover that the purchase of aDynacalibrator and a supply of permeation devices willstart to save them money in the second year of use.Multicomponent mixtures can be easily generated with aDynacalibrator and the appropriate combination ofpermeation devices. This technique also allows the removalof a single component from a gas mixture by simplyremoving the appropriate permeation device. Alternativemethods require expensive custom mixtures or a largenumber of gas cylinders, which consume valuable labspace as well.Bottled standards can also have problems arising fromdegradation of the standard within the cylinder, fromchanges in the concentration levels as the cylinder pressurechanges, and from interaction of calibration componentsand surfaces.(Custom plumbing also available)


SpecificationsFeaturesPermeation chamberPermeation deviceMaximum total lengthMaximum diameterTemperature controlRangeAccuracyAccessoriesCarrier flowDimensionsWeightPassivated glass-coated stainless steel chamberStainless steel capDedicated switched-mode temperature controller withfront panel and serial port controlDigital readout for set point and chamber temperaturePower switch with LED indicator lightStainless steel inlet and outlet fittings for 1/16" tubing(1/4" and 1/8" also available)Universal power input 110 VAC/230 VACCooling fanStainless steel, passivated with Inertium ® andUltradeactivation ® coatingScrew cap access9.5" long by 0.875" ID (24 cm x 2.2 cm)24 cm (9.5")1.6 cm (0.62")30°C to 110°C±0.01°C at a set point from 5°C above ambient to 110°CPower cord for 110 VAC power source(220 VAC <strong>Model</strong> <strong>150</strong>-C)Forceps for removing and inserting permeation devicesTool for removing and securing permeation chamber capRecommended range of 100 - 1200 ml/min6" wide x 15" deep x 7" high(15.4 cm x 38.1 cm x 17.7 cm)10.5 lbs. (4.8 kg)North America, South America, and Australia/Oceania contact:Metronics Inc.tel: 360 697-9199fax: 360 697-6682metronics@vici.comEurope, Asia, and Africa contact:VICI AG Internationaltel: Int + 41 41 925-6200fax: Int + 41 41 925-6201info@vici.chUS customerscall toll-free(877) 737-1887Inertium ® and Ultradeactivation ® are registered trademarks of AMCX (Advanced Materials Components Express).VICI ® is a registered trademark of Valco Instruments Co. Inc. and VICI AG. Dynacalibrator ® and Dynacal ® are registered trademarks of VICI Metronics, Inc. Rev. 11/05

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!