Durag GmbH - Agent: Saacke Australia Pty Ltd<br />

DURAG Continued … … …<br />

Note 1: Class depends upon specific<br />

Burner programmer, flame monitor and<br />

flame sensor<br />

Note 2: Flame failure response time is<br />

not to exceed 2 seconds.<br />

Fireye Inc – Agent: POGC Sensor Technology Pty Ltd<br />

5675 4.01 Electronic Flame Safeguard and Dectectors<br />

Fireye E210/211 Flame Monitoring TM<br />

Microprocessor – Based Burner<br />

Management Control<br />

Configuration: E210/211 complete with<br />

EP 113NR or EP 113E Programmer and<br />

Selected Amplifier Modules & Scanner Types<br />

Scanner<br />

Type<br />

Infrared<br />

Ultra<br />

Violet<br />

Self<br />

check<br />

Ultra-<br />

Violet<br />

Flame<br />

Rod<br />

Photocell<br />

Scanner<br />

Model<br />

Amplifier<br />

Module<br />

AG 210<br />

Class. With<br />

EP113NR<br />

Programmr<br />

AG 210<br />

48PT2-1003 E1R1, E1R3 1A 1Ca, 1Cb<br />

48PT2-1007 E1R1, E1R3 1A 1Ca, 1Cb<br />

48PT2-9003 E1R1, E1R3 1A 1Ca, 1Cb<br />

48PT2-9007 E1R1, E1R3 1A 1Ca, 1Cb<br />

45UV5-1007 EUVS4 1A 1Ca, 1Cb<br />

45UV5-1008 EUVS4 1A 1Ca, 1Cb<br />

45UV5-1009 EUVS4 1A 1Ca, 1Cb<br />

UV1A3 EUV1 2A 2Ca, 2Cb<br />

UV1A6 EUV1 2A 2Ca, 2Cb<br />

UV2 EUV1 2A 2Ca, 2Cb<br />

45UV3-1050 EUV1 2A 2Ca, 2Cb<br />

UV8A EUV1 2A 2Ca, 2Cb<br />

69ND1-<br />

1000K4<br />

ERT1 2A 2Ca, 2Cb<br />

69ND1-<br />

1000K6<br />

ERT1 2A 2Ca, 2Cb<br />

69ND1-<br />

1000K8<br />

ERT1 2A 2Ca, 2Cb<br />

45CM1-<br />

1000<br />

ERT1 2A 2Ca, 2Cb<br />

45CM1-<br />

1000Y<br />

ERT1 2A 2Ca, 2Cb<br />

Note: Additional suffix character denotes different enclosure types to cater for<br />

extreme environment conditions ie. Weather proof, explosion proof etc. Operation<br />

remains unaltered. Contact the manufacturer for further information.<br />

Fireye Inc – Agent: POGC Sensor Technology P/L<br />

5790 11.98 M Series II Electronic Flame Safeguard System<br />

with Ionisation or UV Detection. The list below<br />

shows the combinations of components and class.<br />

Chassis Progrmmr Amplifier UV Scanner<br />

or Flame Rod<br />

Class<br />

MC120E MP100 MARTIT 69NDI 2Cb<br />

MC120RE “ “ “ “<br />

MC120E MP100 MAUVIT UV1A, UV8A 2Cb<br />

MC120RE “ “ “ “<br />

MC120E MP102 MARTIT 69NDI 2B<br />

MC120RE “ “ “ “<br />

MC120E MP102 MAUVIT UV1A, UV8A 2B<br />

MC120RE “ “ “ “<br />

MC230 MP100E MARTIT 69NDI 2Cb<br />

MC230R “ “ “ “<br />

MC230 MP100E MAUVIT UV1A, UV8A 2Cb<br />

MC230R “ “ “ “<br />

MC230 MP102E MARTIT 69NDI 2B<br />

MC230R “ “ “ “<br />

MC230 MP102E MAUVIT UV1A, UV8A 2B<br />

MC230R “ “ “ “<br />

120<br />

Fireye Inc – Agent: POGC Sensor Technology P/L<br />

FIREYE<br />

5974 3.00 Flame Detector<br />

Amplifier Model 25SU3-2000 Class 3D<br />

Note: Comes complete with any of<br />

the following Fireye flame<br />

scanners Models 45UV5-1101,<br />

45RM4-1001 and 45RM4-1000<br />

Georg Hegwein GmbH & Co KG<br />

Agent: Saacke Australia Pty Limited<br />

HEGWEIN<br />

6658 9.04 Z0215Z Series Flame Monitor – Ionization<br />

Type Models Z0215Z0033, Z0215Z033B,<br />

Z0215Z033C, Z0215Z033M, Z0215Z033Y<br />

and Z0215Z033Z 3D<br />

Gosfern Pty Ltd<br />

IRIS<br />

5840 4.99 Model 400 Flame Monitoring System<br />

with UV Detector Class 3D<br />

Model 700 DC Series Flame Monitor<br />

& Scanner Class 3D<br />

Hamworthy Combustion Engineering Limited<br />

6450 6.03 Hamworthy Microprocessor<br />

Based Flame Monitoring<br />

System Model SmartScan 121<br />

Amplifier: Facia Head Unit<br />

Part No 363920652<br />

Panel Head Unit<br />

Part No 363920603<br />

Wall Mount Head Unit<br />

Part No 363920660<br />

Rack Mount Part No<br />

3439017/008/U<br />

Sensor: UV (Safe Area)<br />

Part No 363920794/P<br />

UV (Intrinsically Safe)<br />

Part No 363920802/P<br />

UV (Stainless Steel)<br />

Part No 363921068/P<br />

UV – Vis (Safe Area)<br />

Part No 363920828/P<br />

UV – Vis (Intrinsically Safe)<br />

Part No 363920836/P<br />

UV – Vis (Stainless Steel)<br />

Part No 363921076/P<br />

Refer manufacturers instruction manual<br />

for temperature ratings. Flame failure<br />

response time is selectable, ie 1 sec<br />

or 3 sec. AG 210 specifies response<br />

time is not to exceed 2 sec.<br />

Honeywell Limited<br />

HONEYWELL<br />

3911 4.85 Electronic Flame Switch and Optional<br />

Flame Amplifiers<br />

Flame Switch Model R4348B 1057 Class 3D<br />

Optional Amplifiers:<br />

Ultraviolet:<br />

R7061A 1008, R7061A 1016,<br />

R7247C 1019, R7247C 1035,<br />

R7321B 1010, R7321B 1028,<br />

R7323A 1020, R7323B 1018<br />

and R7323B 1026 Class 3D<br />

Ultraviolet (Adjustable Sensitivity)<br />

R7247B 1011, R7247B 1037<br />

and R7476A 1015 Class 3D<br />

Rectifying Flame Rod:<br />

R7321A 1012 Class 3D<br />

<strong>AGA</strong> Product Directory - July 2006 Edition