13.07.2015 Views

Humboldt Catalog - Asphalt - Comlibris

Humboldt Catalog - Asphalt - Comlibris

Humboldt Catalog - Asphalt - Comlibris

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Specific Gravity—Rice Test1.800.544.7220 • www.humboldtmfg.comRice Test Setup<strong>Asphalt</strong>Typical Rice Test StetupVacuum Pycnometer (Rice Test) Set— H-1750Used in Rice testing to determine the maximum specific gravity ofbituminous paving mixtures with maximum aggregate size up to19.1mm (3/4in.). 2000g capacity, 7-1/2" ID x 6" depth. Set includesaluminum volumetric canister; volumetric lid; flat, Plexiglas vacuumlid with O-ring; volumeter; vacuum gauge with release valve andfittings (dial reading 0 to 30"), and a metal water vacuum aspiratorwith 3/8" IPT and 6' hose. Unit achieves vacuum using an aspirator oroptional vacuum pump. Use with H-1756 vibrating table, andH-1754D manometer, sold separately. See page 150 for vacuumpumps. Replacement parts are available, please inquire.Meets ASTM D2041; AASHTO T209, T283.H-1820H-1820H-1750Aluminum Lid— H-1750.2Replacement lid for models H-1750 and H-1751.O-Ring— H-1750.3Replacement o-ring for models H-1750 and H-1751.Stainless Steel, Vacuum Pycnometer Set— H-1750SSSame as H-1750 except stainless steel vessel.Small Vacuum Pycnometer Set— H-1751Same as H-1750 except 1500g capacity, 7-1/2" ID x 4" depth.Large-Capacity Vacuum Pycnometer Set— H-1820Large-capacity unit, 10L (2.64 gal.), 6000g (13.2 lbs.) sample weight,with maximum aggregate size of 50mm (2in.). Set features domedtransparent cover for easy observation of sample testing, perforatedplastic shelf, which some States require; water inlet valve and 1/4"ID hose, quick-disconnect, vacuum gauge, vacuum hose andaspirator with 3/8" NPT fitting. Flange OD is 10-3/4" (273mm);maximum clearance above plate is 7-3/4" (197mm). Use withH-1826A vibrating table, and H-1754D manometer, sold separately.See page 150 for vacuum pumps. Replacement parts areavailable, please inquire. Dimensions: 9-7/16" ID x 12-1/8"(240 ID x 311mm). Meets AASHTO T209, T283.H-1754DDigital Manometer— H-1754DDigital Manometer, Certified— H-1754DCAA precise measurement device designed to replace mercury-filledmanometers used in Rice test applications. This portable, hand-helddevice can be easily moved around the laboratory. Holes areprovided for bench or wall mounting and a 3/8" barb fitting isused for quick connections. The instrument features a digital displayrange of 0 to 1000mm Hg (absolute) at a resolution of 0.1mm Hg.The device has a rated accuracy of +/-0.5% full scale and is poweredby one 9V battery.Slow Release Valve for Vacuum Pycnometers— H-1749For use with H-1750, H-1751 and H-1820 for greater accuracy andshorter dry back time. Brass valve maintains 30mm vacuum pressureon sample. Meets ASTM D2041, AASHTO T283.H-1749148

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!