13.07.2015 Views

MZ Liberec katalog

MZ Liberec katalog

MZ Liberec katalog

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CATALOGUESINCE 1958


WE ARE DEVELOPING 55 YEARS´ MANUFACTURE EXPERIENCE AND BRAND NAME TRADITION IN THE FIELDOF MEDICAL GAS TECHNOLOGYWE ARE FOCUSING OUR PRODUCTION SCOPE ON INSTALLATION OF FINAL ELEMENTS TO MEDICAL GAS DISTRIBUTIONSYSTEMS, INCLUDING GAS SOURCES AND GAS PIPELINE NETWORKWE OFFER ALL-INCLUSIVE OPTIONS LIKE PROJECT STUDY, INTERIOR DESIGN, BUILD-UP, MANUFACTURE,FINAL ASSEMBLY ON-SITE AS WELL AS AFTER-SALE SERVICESWE ARE EUROPEAN MANUFACTURERS HAVING A HIGH QUALITY OF PRODUCTS, PROFESSIONAL STAFFAND TOP EXPERIENCED EXPERTSWE HAVE STRONG AND FLEXIBLE TEAM OF DESIGNERS-ENGINEERS WHO ARE ABLE TO PROVIDE A FULL CUSTOMIZEDSOLUTIONWE GUARANTEE RELIABLE SHIPMENTS TO ALL CUSTOMERS IN A SHORT TIMEWE DESIGN OUR PRODUCTS UPON CUSTOMERS´ WISHES AND THEIR REQUESTS ON GLOBAL APPEARANCE OF INTERIORWE COMPLY INTERNATIONAL DIRECTIVES AND RULES RELATED TO MEDICAL DEVICES CONCERNEDAND MEDICAL GAS DISTRIBUTION SYSTEMWE USE FIRST-CLASS MATERIALS AND APPLY LATEST TECHNOLOGY IN PRODUCTION PROCESSING,WHICH CONTRIBUTES TO A PROTECTION OF ENVIRONMENTWE PROVIDE ALL-IN-ONE ASSISTANCE TO OUR CUSTOMERS THROUGH AUTHORIZED DEALERS LOCATED ON-SITEWE ARE RELIABLE AND LONG-TERM PARTNERS FOR HEALTHCARE PROFESSIONALS WORLDWIDE


CONTENTSCONTENTSCEILING PENDANTS 4 - 27SWIVELLING AND TILTING CEILING PENDANTS (OK07-57, OK07-55) 6 - 9SWIVELLING CEILING PENDANTS (OK07-28, OK07-16) 10 - 13STATIONARY AND HEIGHT-ADJUSTABLE CEILING PENDANTS (PS07, VK07, OK07-05) 14 - 16CEILING PENDANTS WITH COMPACT SPRING BALANCED ARMS (SPR10, SPR11) 17SOURCE COLUMNS TO CEILING PENDANTS 18 - 25TANDEM OPTION OF CEILING PENDANTS 26 - 27BED HEAD UNITS AND SUPPLY COLUMN UNITS 28 - 41BED HEAD UNITS (RN07-DN0) 30 - 31BED HEAD UNITS (RN07-DN1) 32 - 33BED HEAD UNITS (RN07-DN2) 34 - 35BED HEAD UNITS (RN07-DN3, RN07-DN3Z) 36 - 39SUPPLY COLUMN UNITS (ZS07, ZS07L) 40 - 41MEDICAL BEAMS 42 - 45MEDICAL BEAMS (ZMP07) 42 - 43MEDICAL BEAMS (LAMINAR, DOUBLE-SIDED) 44 - 452


CONTENTSCONTENTSMEDICAL GAS SOURCE STATIONS 46 - 49COMPRESSOR AND VACUUM STATIONS 46 - 47CYLINDER STATIONS 48OXYGEN CONCENTRATORS 49GAS DISTRIBUTION ELEMENTS 50 - 52GAS MONITORING DEVICE (<strong>MZ</strong>U 010 / II) 50GROUP ISOLATORS 51WALL-MOUNTED PANELS 52AUXILIARY ELEMENTS 53 - 55ACCESSORIES - GAS QUICK OUTLETS 53FLOWMETERS, DISPENSERS-HUMIDIFIERS, REDUCTION VALVES 54 - 55PROJECT ENGINEERING, ASSEMBLY, SERVICE & MAINTENANCE 56 - 57CERTIFICATES 58 - 59REFERENCES 603


CEILING PENDANTSCeiling pendants arrange the supplyof medical gases, electric power networkand low voltage cabling from ceiling itselfto a workplace of medical specialists.The source columns of different types(according to the specific requirementsof healthcare facilities) are to be consideredtheir integral part. The payload of ceilingpendant depends on a type of source headused and an arm length chosen. Colour andsize are optional upon customer‘s wishes.4


CEILING PENDANTSSWIVELLING AND TILTING CEILING PENDANTSCEILING PENDANT TYPE OK07-57 OK07-55 OK07-28 OK07-16 OK07-05 PS07 VK07horizontal setting x x x xsingle armed x xdouble armed x xvertical setting x x xsource column A (head) x x x x x x xsource column L (head) x x x x xsource column Z (head) x x xrotary source column (head) x x x x xOK07-57 PS07 OK07-285


CEILING PENDANTSOK07-57This type of ceiling pendant allowsa variable positioning of source columneither in horizontal or/and in verticaldirection, and also its setting whereverwithin its arms might reach.6


TYPE: OK07-57SWIVELLING AND TILTING CEILING PENDANTS31500 mm2800 mm330°400 - 1000 mm330°4330°1 - ceiling cover2 - swivelling (rotary) arm3 - tilting arm4 - source column (head)7


CEILING PENDANTSOK07-55This type of ceiling pendant allowsa variable positioning of source columneither in horizontal or/and vertical directionas well as its circular motion in a certainradius determined by an arm length.8


TYPE: OK07-55SWIVELLING AND TILTING CEILING PENDANTS2 1500 mm800 mm330°3330°1 - ceiling cover2 - tilting arm3 - source column (head)9


CEILING PENDANTSOK07-28This type of ceiling pendant allowsa variable positioning of source columneither in horizontal or/and vertical directionas well as its setting wherever its armsmight reach.10


TYPE: OK07-28SWIVELLING CEILING PENDANTS213400 - 1000 mm400 - 1000 mm 330°330°4330°1 - ceiling cover2 - upper swivelling (rotary) arm3 - lower swivelling (rotary) arm4 - source column (head)11


CEILING PENDANTSOK07-16This type of ceiling pendant allowsa variable positioning of source columneither in horizontal or/and vertical directionas well as its circular motion in a certainradius determined by an arm length.12


TYPE: OK07-16SWIVELLING CEILING PENDANTS21400 - 1000 mm330°3330°1 - ceiling cover2 - swivelling (rotary) arm3 - source column (head)13


CEILING PENDANTSSTATIONARY CEILING PENDANTS PS07PS07PS07 WITH SPRING BALANCED ARM SPR10This type of ceiling pendant allows an installation of sourcecolumn in a particularly specified place.11 - ceiling cover2 - source column (head)3 - suspended shelf system2314


CEILING PENDANTSHEIGHT- ADJUSTABLE CEILING PENDANTS VK0712364 5This type of ceiling pendant allows an installation of sourcecolumn in a particularly specified place and its setting in avertical position.360°71 - fault ceiling part2 - ceiling cover3 - retractable stem4 - source column (head)5 - medical gas outlet6 - inspection (control) gauges7 - roller with shelvesVK0715


CEILING PENDANTSSTATIONARY CEILING PENDANTS OKO7-05OK07-05 WITH ARMS TO ANCHOR ACCESSORIESThis type of ceiling pendant allows an installation of sourcecolumn in a particularly specified place and its own axisrotation.121 - ceiling cover2 - source column (head)330°16


CEILING PENDANTSWITH COMPACT SPRING BALANCED ARMS SPR10, SPR11Spring balanced arm with verticalunequipped tail-pieceG - scopeof permitted service loadThe ceiling pendants withcompact spring balanced, tiltingand swivelling (rotary) armsmanufactured in types SPR10or/and SPR11 and theircombinations, are carriers ofmedical accessories - operatinglights, cameras, monitors, X-rayprotective barriers and others.700 - 1100 800 - 966GV5 - 28 (kg) 0 - 14 (kg)SPR10SPR111100 (mm) 950 (mm)V - lifting heightSPR1117


CEILING PENDANTSSOURCE COLUMNS TO CEILING PENDANTSSuch a column combines in itself medicalgas outlets and electrical & media socketsin the workplace of medical staff with highdemands on technical facility equipment.Itsfitting is optional as per individual needsof the workplace concerned.18


CEILING PENDANTSSOURCE COLUMNS TO CEILING PENDANTSSOURCE COLUMNS L06 L10 L15 A Zlength of rods to shelves and accessories (mm) 600 1000 1500 400 - 1000 0recommended number of shelves 1 2 4 1 xtread depthxtread depth free x x x xusually for anaestheologist workplace x xusually for surgeon workplace x x xusually for surgical intervention operating theatres x x19


CEILING PENDANTSL06, L10, L15Its frontwall is equipped with two stainlesssteel brackets which vertically adjustableshelves, infusion pumpholders or otherequipment can be attached to. The sidewallsare set with media outlets.The source column can be combined withany arms of series OK07. Available in threelengths L06 (694 mm), L10 (1094 mm)and L15 (1594 mm) that determine themaximum equipment of the source columnconcerned.20


TYPE: L06, L10, L15SOURCE COLUMNS TO CEILING PENDANTS1 - back column cover2 - air motor outlet and AGSS outlet3 - high-voltage electrical outlet4 - jack bushes (earthing)5 - arm motion control6 - medical rail7 - shelf8 - rod for shelves and other accessories1 824375621


CEILING PENDANTSSOURCE COLUMN A (HEAD)This source column is the most frequentlyused either in anaesthesiology sectionorwhereverit is necessary to have enoughspace hereunder. Column setting is optionalas per the individual needs of the workplace.In the bottom part this source columnmay be equipped with two stainless steelbrackets which vertically adjustable shelves,infusion pump holders or other equipmentcan be fitted to. The front and rear wallsare set with media outlets. The sourcecolumn can be combined with any armsof series OK07.22


SOURCE COLUMN ASOURCE COLUMNS TO CEILING PENDANTS1 - medical gas quick outlets2 - air motor outlet and AGSS outlet3 - high-voltage electric sockets4 - jack bushes (earthing)5 - arm motion control6 - medical rail7 - shelf8 - rod for shelves and other accessories63 42 187523


CEILING PENDANTSSOURCE COLUMN ZThis source column is the most frequentlyused in anaesthesiology section.Its advantage is possibility to suspendan anaesthesiologic machine on.Thisfeature allows a permanent connectionbetween that device and the source columnwhen handled in the operation theatre andwhen this area is disinfected. Column fittingis optional as per individual needs of theworkplace concerned.The source columncan be fitted with different standard holdersof anaesthesiologic device. Media outletsare set from the rearwall of the column.The source column can be combinedwith arms of series OK07-28, OK07-16,OK07-05.24


SOURCE COLUMN ZSOURCE COLUMNS TO CEILING PENDANTS1 - medical gas quick outlets2 - gauges3 - high-voltage electric sockets4 - jack bushes (earthing)5 - lift control of machine holder6 - arm motion control7 - holder of anesthesiology machine8 - handle with control button9 - air motor outlet and AGSS outlet1236845925


CEILING PENDANTSAny type of ceiling pendant and sourcecolumns can be combined each other,altogether.This option is suitable forhealthcare facilities with the most intensivepatient care. Its main advantage is the highcapacity of media outlets and possibilityto mount a large number of differentaccessories and equipments. Of course,it is comfortable for physicians and nursesas well.26


CEILING PENDANTSTANDEM OPTION OF CEILING PENDANTS27


BED HEAD UNITSBed head units are especially designedfor patients´ wards and medical facilities,where medical gas outlets, high-voltageand low-voltage sockets are required.Direct,indirect or night lights (either fluorescentor LED types) may become a part of bedhead units, too. Their design is oftenmatching the total appearance of wardinterior.28


BED HEAD UNITSBED HEAD UNITSBED HEAD UNIT TYPE DN0 DN1 DN2 DN3 DN3-Z ZS07horizontal installation x x x x xvertical installationxdirect and night lighting x x xindirect lighting x x x xfitting to medical gases x x x x xfor in-patient wards x x x xfor ICU x x x xwall built-inxmultiple-bed options x x x x29


BED HEAD UNITSRN07-DN0Bed head unit RN07-DN0 is designed forstandard patient wards where no medicalgas outlets are needed. It containshigh-voltage and low-voltage powerinstallations. It can be fitted direct, indirectand night lighting. Of course, medical railand other optional accessories canbe mounted on.30


TYPE: RN07-DN0BED HEAD UNITS211 - high-voltage electric sockets2 - medical rail231


BED HEAD UNITSRN07-DN1Bed head unit RN07-DN1 is designed forstandard patient wards where medicalgas outlets, high-voltage & low-voltageinstallations are needed. It can be equippedwith direct, indirect and night lights.Of course, medical rail and other optionalaccessories can be mounted on.32


TYPE: RN07-DN1BED HEAD UNITS3311221 - high-voltage electric sockets2 - medical gas quick outlets3 - medical rail33


BED HEAD UNITSRN07-DN2Bed head unit RN07-DN2 allowsa multi-spectral placement of medicalgas outlets and low-voltage installationson the left/right side or just in the middleof itself. It is distinguished by an easyplugging-in of multibedded options to themedical gas distribution systemand low-voltage power circuit.34


TYPE: RN07-DN2BED HEAD UNITS3123121 - high-voltage electric sockets2 - medical gas quick outlets3 - medical rail35


BED HEAD UNITSRN07-DN3Bed head unit RN07-DN3 allows a multispectralplacement of medical gas outletsand low-voltage installations on the left/right side or just in the middle of itself.It is distinguished by an easy plugging-inof multibedded options to the medical gasdistribution system and low-voltage powercircuit. Its essential advantage is a lowdepth. So it does not touch the manipulationspace in front of itself.36


TYPE: RN07-DN3BED HEAD UNITS3311221 - high-voltage electric sockets2 - medical gas quick outlets3 - medical rail37


BED HEAD UNITSSINGLE-CHANNELLED RN07-DN3RN07-DN32 1Bed head unit RN07-DN3 is designed for standard patientwards with a need of medical gas outlets. It containshigh-voltage and low-voltage installations. Medical railand other optional accessories can be mounted on. Itsessential advantage is a low depth. So it does not touch themanipulation space in front of itself.1 - high-voltage electric sockets2 - medical gas quick outlets38


BED HEAD UNITSIN-BUILT RN07-DN3Z1This bed head unit is designed for standard in-patient wardswith the need for outlets of medical gases, high-voltageelectricity and low-voltage installations.Optional accessories can be mounted on bed head unit,too. Its main feature is the design intended for installation inthe interior (part of a furniture set, behind a painting, etc.)1 - high-voltage electric sockets2 - medical gas quick outlets2RN07-DN3Z39


BED HEAD UNITSSUPPLY COLUMNS ZS07ZS07Supply columns are mainly used in places where it isimpossible to install bed head unit, i.e. between windows,glazed walls, support columns, etc.The rod mounted on thecolumn foreside is intended for fixation of adjustable rotaryshelves with medical rails and accessories.43211 - shelf2 - rod for shelves and other accessories3 - medical gas quick outlets4 - high-voltage electric sockets40


BED HEAD UNITSSUPPLY COLUMNS ZS07LThese vertical supply columns are primarily fitted in sucha space where bed head units cannot be wall-mounted, i.e.between windows, on glass-walled areas, on supportingpillars etc.. In the front side of supply column there is a rodused for fixation of height-adjustable and adaptive shelvesequipped with medical rails and accessories.1 - shelf2 - rod for shelves and other accessories3 - medical gas quick outlets4 - high-voltage electric sockets5,6 - indirect lighting5ZS07L4213641


MEDICAL BEAMSZMP07Medical beams are designed to providemedical gas, electric power and datadistribution as close as possible tothe bedside area. It is mainly used forspecialized medical facilities (ICU, ARD).The medical beam can be fitted with halogenor LED spot lamp, bracket arms, telescopicrod with curtain, medical rail, positional(night) light or other accessories uponneeds & requirements of the workplaceconcerned. Thanks to its design it ensuresan optimal use of space with begard tosafety of patient as well as medical staff.42


TYPE: ZMP07MEDICAL BEAM4231 - rotary roller with shelf2 - ceiling cover3 - arms for accessories4 - suspended ceiling depth1360°43


MEDICAL BEAMSLAMINAR ZMP07ZMP07Laminar medical beam ZMP07 is used wherever a laminarair-flow coming from ceiling to be streamlined, namely insupra-aseptic environment. It is available in U- or L-shapedoptions, too.44


MEDICAL BEAMSDOUBLE-SIDED ZMP0743This type of medical beam is used wherever medical gasoutlets and high/low-voltage installations to be fitted bothmodule sides.1 - electrical socket2 - indirect light3 - direct light4 - medical rail5 - gas quick outlet6 - beam stem125ZMP0745


MEDICAL GAS SOURCE STATIONSCOMPRESSOR STATIONSCompressor station provides (in automatic mode)the required pressure and the planned flow of medicalcompressed air, in a quality complied with EuropeanDirectives as well as other standards valid worldwide.They are stationary units available in several options, e.g.oilfree - oil, spiral - piston, differing each other by coolingsubstance, type of drive, etc. Standard compressor stationsare supplied with an output of 2.2 to 608 Nm 3 /hour.46


MEDICAL GAS SOURCE STATIONSVACUUM STATIONSIt provides (in automatic mode) the required suctionand the planned flow of medical vacuum for needsof vacuum suction. A very important part is treatment andcleaning of contamined exhaust air. Therefore, it is necessaryto equip each vacuum station in automatic mode with perfectantibacterial filter and dirt arrester.Standard range of vacuum stations with capacities from6.4 to 632 Nm 3 /hour is supplied.47


MEDICAL GAS SOURCE STATIONSCYLINDER STATIONSCylinder solution is the oldest, the most proven and also thecheapest investment method how to arrange the medical gassupply. However its great disadvantage consists in a difficulthandling with heavy cylinders and in a costly maintenance.We supply cylinder sources with automatic, semi-automaticand manual switches. The designed flow is 15 m 3 /hrto 300 m 3 /hr.48


MEDICAL GAS SOURCE STATIONSOXYGEN CONCENTRATORSAir CompressorRefrigerated DryerAir Buffer TankPSA ConcentratorOxygen ReceiverSterile FiltersComplete OXYSWING® System.Oxygen concentrator is based on the use of molecularsieves being able to separate nitrogen from oxygen becauseof different size of molecules. This equipment is able toproduce oxygen-enriched air with 93-95% oxygen.This gas may replace medical oxygen in case all requiredfeatures are observed. Oxygen concentrator is availablein six different volumes with a production capacity from3 to 48 Nm 3 /hr 0 2.49


GAS DISTRIBUTION ELEMENTSGAS PRESSURE WARNING <strong>MZ</strong>U 010 / II<strong>MZ</strong>U 010 / IIMonitoring device <strong>MZ</strong>U with touchscreen is designed for clinical and operationalstatus warning in medical gas pipeline and distribution resources. Its purposeis either to warn the staff by means of light or/and sound alarm that somethingunusual with gas pressure, flow or supply happened, or to send a status informationto external devices. <strong>MZ</strong>U can be built-in or wall-mounted, its setting is always donein menu using a touchscreen. The pre-setting of the monitored parameters is donein device menu through touchscreen directly at the place of installation.MPaOPERATION THEATRE50


GAS DISTRIBUTION ELEMENTSGROUP ISOLATORSPKNVTGroup isolator is intended for stopping the gas flow tothe next distribution area.It serves solely for emergencypurposes and for maintenance, not for routine use.Its pressure sensors are designed for warning becauseof non-standard pressure in the distribution area concerned.They are configured for upto 5 gases, including anycombination of your own choice.K - branch closing (*ball cocks with selected parameters)V - drainsN - emergency inputs: DN 4, PN 10 medical gas quick outletsT - output pressure gauges *S - pressure sensors* (for signalling systems)P - signalling wire passageSU 03S51


GAS DISTRIBUTION ELEMENTSWALL-MOUNTED PANELSUR.17 BWall-mounted panels is connecting point to the medicalgas distribution network. It can be equipped either witha medical gas quick outlet specified for gas concernedor with a pressure gauge. They are manufactured in twooptions - either with surgical instruments drive - air engineor with exhaust system adapted to exhale mixturesof anaestethic gases - AGSS. It can be built-inor wall-mounted.52


AUXILIARY ELEMENTSGAS QUICK OUTLETSGas quick outlet is intended for easy connection anddisconnection of two distribution sections. When connectedwith the counter-piece in question, the tough and tightcircuit is created. In case of disconnection it works likea self-acting stopper with separation valve. The gas quickoutlet is available in several options that differ each otherwith a kind of mounting on mother board and way ofconnection to the central distribution network.It is immutable for certain gases and manufacturedin colour-distinguishable media options. The adaptorsare placed into the gas quick outlets and such a connectionbecomes a functional unit.Type denomination Gas ColourUR 107 O 2whiteUR 507 N 2O blueUR 607 air black & whiteUR 807 negative pressure yellow & blackUR 707 CO 2grey53


AUXILIARY ELEMENTSFLOWMETERS DISPENSERS-HUMIDIFIERSFLOWMETER ME.03DISPENSER - HUMIDIFIERS <strong>MZ</strong> 103 F, <strong>MZ</strong> 104 FThey are intended for oxygen dosage from centraldistribution network and simultaneously for its efficacioushumidification. The relative oxygen humidity is 80 pctat least. They can be easily linked up to other oxygendistribution sealings with gas quick outlets. Their flow canbe adjusted in two levels - 1 to 5 l/min and/or 2 to 20l/min.54


AUXILIARY ELEMENTSVACUUM REDUCTION VALVERV.02 is a special low-pressure reduction valve intended formanual pressure adjusment of passing-through fluid media.Its connectable to all (formerly or temporarily) manufacturedgas quick outlets. Input pressure is 300 - 1000 kPa, outputpressure is 20 - 700 kPa.Vacuum reduction valve type VR01 is intendedfor a reduction of underpressure coming from centraldistribution underpressure circuit. It is connectable to allunderpressure distribution sealings with gas quick outlets.The underpressure adjustment is achieved by turningtheregulation knob located in the valve body axis.It is equipped with a vacuum meter that may checkthe output underpressure in a range from 0 upto 100 kPa.RV.02VR.0155


PROJECT ENGINEERING, ASSEMBLY, SERVICE & MAINTENANCEPROJECT ENGINEERINGThe company is fully certified for all its project engineering activities. The team of designers is ready to give a turn-key projectsolution, i.e. gas sources, pipeline distribution network and source column supply units of medical as well as technical gasesincluded. Any project engineering services are provided in a full compliance with EN 7396 or local norms (if requested). We are ableto satisfy any customers, starting from small projects through huge hospital deals. The top-class project study is always tailor-madeand trying to meet all client´s possible and/or impossible dreams.56


PROJECT ENGINEERING, ASSEMBLY, SERVICE & MAINTENANCEASSEMBLYOur experienced and permanently well-trained staff provides an high-quality assembly of the supplied medical gas deviceson-site, both in the Czech republic and in abroad. These assembly services are done in a conformity to EN 7396. Theassembly period is tailored to the customers´ requests and notions.SERVICE AND MAINTENANCEWe offer a wide range of services that may seriously reduce the standard user´s risks. Such services are provided withina guarantee period or/and thereafter, general overhauls included. Furthermore the safety and functionality testing (likeregular safety technical controls), check-ups, inspections, drawing-ups of operational documents, status reports (includingrectification proposals) are realized as well.On the territory of the Czech republic we are entitled to provide and to offer quality check-ups of medical gases as perEuropean Pharmacopoeia. Our laboratory has been appointed for that business by the State Insitute of Drug Control inPrague.57


58CERTIFICATES


CERTIFICATES59


OUR REFERENCE LISTCOUNTRY HOSPITAL/CLINICCOUNTRY HOSPITAL/CLINICALBANIASALUZ HOSPITAL TIRANAAZERBAIJANMTN HOSPITAL BAKUBELGIUMMILITARY HOSPITAL REINE ASTRIDIN NEDER-OVER-HEMBEECK BRUSSELSBELGIUMREHABILITATION HOSPITAL VALIDAIN BERCHEM-STE-AGATHE BRUSSELSCAMEROONHOSPITAL CENTER PANAFRICAIN GSA DOUALACZECH REPUBLIC UNIVERSITY HOSPITAL IN MOTOL PRAGUECZECH REPUBLIC INSTITUTE FOR CLINICALAND EXPERIMENTAL MEDICINE PRAGUECZECH REPUBLIC UNIVERSITY HOSPITAL BRNOCZECH REPUBLIC HOSPITAL NA FRANTIŠKU PRAGUECZECH REPUBLIC NA HOMOLCE HOSPITAL PRAGUECZECH REPUBLIC UNIVERSITY HOSPITAL KRÁLOVSKÉ VINOHRADYPRAGUECZECH REPUBLIC THOMAYER HOSPITAL PRAGUECZECH REPUBLIC LIBEREC REGIONAL HOSPITALCZECH REPUBLIC HOSPITAL PŘÍBRAMCZECH REPUBLIC HOSPITAL CARLSBADCZECH REPUBLIC MASARYK HOSPITAL IN ÚSTÍ NAD LABEMCZECH REPUBLIC HOSPITAL JINDŘICHŮV HRADECCZECH REPUBLIC HOSPITAL CHEBCZECH REPUBLIC HOSPITAL „PODHORSKÁ“ BRUNTÁLCZECH REPUBLIC UNIVERSITY HOSPITAL ST. ANNA BRNOCZECH REPUBLIC UNIVERSITY HOSPITAL OSTRAVACZECH REPUBLIC UNIVERSITY HOSPITAL HRADEC KRÁLOVÉCZECH REPUBLIC REGIONAL HOSPITAL MLADÁ BOLESLAVCZECH REPUBLIC REGIONAL HOSPITAL KLADNOCZECH REPUBLIC UNIVERSITY HOSPITAL PLZEŇFINLANDHELSINKI UNIVERSITY HOSPITALGABONOWENDO HOSPITAL LIBREVILLEGEORGIASACHKERE MEDICAL CENTERGERMANYHOSPITAL FRANKFURT AM MAINHUNGARYHOSPITAL DEBRECENIRELANDCORK UNIVERSITY HOSPITALITALYEUROPEAN HOSPITAL ROMAITALYPOLICLINICO PORTUENSE ROMAITALYOSPEDALE SAN RAFAELE DI PISANA (ROMA)KAZAKHSTANPRENATAL CENTRUM ALMATYKAZAKHSTANPRENATAL CENTRE ALMATYKAZAKHSTANEMERGENCY HOSPITAL ALMATYKAZAKHSTANCHILDREN HOSPITAL ALMATYKAZAKHSTANKAZAKHSTANLEBANONLIBYALITHUANIALITHUANIALITHUANIALITHUANIALITHUANIAPOLANDPOLANDPOLANDPOLANDPOLANDPORTUGALROMANIAROMANIAROMANIAROMANIAROMANIAROMANIARUSSIARUSSIARUSSIARUSSIARUSSIARUSSIARUSSIARUSSIARUSSIARUSSIASAUDI ARABIASUDANSUDANSYRIATHE NETHERLANDSTHE NETHERLANDSUZBEKISTANYEMENCARDIOLOGIC CENTRE KARAGANDYPRENATAL CENTRE CHIMKENTRIZK HOSPITAL BEIRUTJAMIL HOSPITALHOSPITAL TRAKAJ CITYREGIONAL CLINIC KLAJPEDAFAMILY CLINIC SHAULIAJCITY HOSPITAL SHILUJTECITY HOSPITAL SANTORISHKEHOSPITAL KAMIENNA GORAHOSPITAL-OIOM-PULTUSKHOSPITAL SW.RAFALA KRAKOWHOSPITAL DR.SOKOLOWSKIEGO WALBRZYCHHOSPITAL MIEJSKI BYDGOSZCZHOSPITAL LISBOAINEU TOWN HOSPITALDR.GEORGE TRIFON TOWN HOSPITALNĂSAUDFOISOR HOSPITAL BUCHARESTST.STEFAN HOSPITAL BUCHARESTCOUNTY EMERGENCY HOSPITAL TIMIŞOARAVICTOR GOMOIU HOSPITAL BUCHARESTMATERNAL HOSPITAL OMSKMATERNAL HOSPITAL SALAVATMATERNAL HOSPITAL BELORECKREGIONAL HOSPITAL OMSKREGIONAL HOSPITAL ARCHANGELSKREGIONAL HOSPITAL STAVROPOLREGIONAL CLINIC HOSPITAL EKATERINBURGCITY HOSPITAL NOJABRSKMEDICAL CENTER ULAN-UDERUSSIAN FINNISH CLINIC SCANDINAVIAST.PETERSBURGZAHRAN AL-JANOUB HOSPITAL RIYADHHOSPITAL MADANISOBA UNIVERSITY HOSPITAL KHARTOUMDR.SHAMI HOSPITAL DAMASCUSAZM MAASTRICHTMAXIMA MEDISCH CENTRUM VELDHOVENREPUBLICAN SPECIALIZED CENTER OF SURGERYTASHKENTIBN SINA HOSPITAL AL MUKALLA60


Czech RepublicPhone: +420 488 040 375Fax: +420 488 040 326E-mail: export@mzliberec.czwww.mzliberec.czCopyright © <strong>MZ</strong> <strong>Liberec</strong>, a.s., 2013EUROPEAN UNIONEUROPEAN REGIONAL DEVELOPMENT FUNDINVESTMENT IN YOUR FUTURE

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!