<strong>Drain</strong> <strong>Waste</strong> & <strong>Vent</strong> (<strong>DWV</strong>) <strong>Systems</strong>SCJ PIPE & FITTINGS FOR NON-PRESSURE SEWERAGE APPLICATIONS


contents<strong>Drain</strong> <strong>Waste</strong> & <strong>Vent</strong> (<strong>DWV</strong>) <strong>Systems</strong>SCJ PIPE & FITTINGS FOR NON-PRESSURE SEWERAGE APPLICATIONSproduct manualContentsIntroductionBenefitsThe CompanyQualityAustralian StandardsDrawings and Dimensions<strong>DWV</strong> Sewer Pipe<strong>DWV</strong> Sewer Pipe (Heavy)<strong>DWV</strong> Sewer Pipe (Extra Heavy)<strong>DWV</strong> Sewer FittingsBendsManhold Drop BendsJunctionsTeesAccess CoupldingsThreaded Access CapsCouplingsLevel Invert TapersPush On CapsDisconnector TrapsRisersBoundary TrapProperty ConnectorsAdaptorsBushesSquash Top InletsSocket PlugsFlangesSleevesVertical BackdropsSaddlesSolvent Cement & Priming FluidSolvent Cement Type ‘P’Solvent Cement Type ‘N’Priming FluidStandard Symbol GuideStandard SCJ Symbols<strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> -1


<strong>DWV</strong> Sewer Pipe SCJIntroductionPVC is widely accepted as the preferredpipe for sewer applications, withadvantages of cost effectiveness, longlengths, ease of handling and installation,resistance to root penetration and itsproven performance.The following catalogue details the rangeof SCJ products manufactured by Vinidexfor sewerage applications and includedproduct data for sewer pipe, sewer fittingsand appropriate solvent cement andpriming fluids.Vinidex also specialises in fabricatedfittings for custom applications. Contactyour nearest Vinidex office to discusscustomised requirements.2<strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> -


<strong>DWV</strong> Sewer Pipe SCJNom. size Angle Code Qty per carton L1 L2(mm) (mm) (mm)45 o PLAIN BENDS F&F100* 45 o 46040 40 84150* 45 o 47010 12 122225* 45 o 47410 5 190225 45 o 47610 235300 45 o 48010 330375 45 o 48470 55090 o PLAIN BENDS F&F100* 90 o 46080 28 165150* 88 o 47030 8 226225* 90 o 47420 3 290225 90 o 47620 375300 90 o 48020 500375 90 o 48480 740OTHER PLAIN BENDS F & F100* 5 o 46000 60 60100* 30 o 46020 45 75100* 60 o 46070 35 93225 30 o 47605 230225 22.5 o 47603 215300 60 o 48015 395SIDE ACCESS BENDS F & F100* 45 o 46050 20 116100* 88 o 46090 15 170REAR ACCESS BENDS225* F & F 90 o 47625 375*Moulded fitting, all other products are custom fabricated.Note: All fittings are custom fabricated unless otherwise specified<strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> -5


<strong>DWV</strong> Sewer Pipe SCJNom. size Angle Code Qty per L1 L2 Type(mm) carton (mm) (mm)90 o MANHOLE DROP BENDS M & F100 90 o 47531 150 110 (MMBW -)150 90 o 47571 220 160 (MMBW -)225 x 150 90 o 47860 450 250 (MMBW -90 o MANHOLE DROP BENDS F & F100 90 o 47530 160 110 (MMBW -)150 90 o 47570 235 260 (MMBW -)225 90 o 47658 520 495 (MMBW -)45 o JUNCTIONS F & F100* 45 o 46200 16 259 190 Threaded Top & Branch100* 45 o 46205 4 277 198 Threaded Top & Branch150* 45 o 47120 4 427 274 Threaded Top & Branch225* 45 o 47450 2 585 440225 45 o 47680 770 520300 45 o 48090 960 670375 45 o 48560 1490 945175/100 45 o 47586 620 250 (MMBW – 13)175/150 45 o 47587 690 325 (MMBW – 14)*Moulded fitting, all other products are custom fabricated.Note: All fittings are custom fabricated unless otherwise specified6<strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> -


<strong>DWV</strong> Sewer Pipe SCJNom. size Angle Code Qty per L1 L2 Type(mm) carton (mm) (mm)45 o REDUCING JUNCTIONS F & F100 x 65 43 o 46220 20 228 167 Threaded - Branch150 x 100 45 o 47110 7 336 263 RRJ Branch225 x 100 45 o 47440 4 480 290 Threaded - Branch225 x 150 45 o 47445 3 480 360225 x 100 45 o 47660 530 250300 x 100 45 o 48060 660 400300 x 150 45 o 48070 760 470300 x 225 45 o 48080 920 600375 x 100 45 o 48520 1100 490375 x 150 45 o 48530 1150 530375 x 225 45 o 48540 1290 660375 x 300 45 o 48550 1370 81090 o JUNCTIONS F & F100* 90 o 46300 18 240 145 Threaded - Branch150* 90 o 47205 4 354 204225 90 o 47740 770 580300 90 o 48170 960 845375 90 o q2746 1490 106990 o REDUCING JUNCTIONS F & F150 x 100 90 o 47190 6 300 175 Threaded - Branch225 x 150 90 o 47730300 x 225 90 o 4816045 o SIDE ACCESS JUNCTIONS F & F100 45 o 46230 12 277 198 RH100 45 o 46240 12 277 198 LH*Moulded fitting, all other products are custom fabricated.Note: All fittings are custom fabricated unless otherwise specified<strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> -7


<strong>DWV</strong> Sewer Pipe SCJNom. size Angle Code Qty per L1 L2 Type(mm) carton (mm) (mm)90 o REAR ACCESS JUNCTIONS F & F100* 90 o 46310 12 240 145150 90 o 47584 360 204TEE F & F (without cap)100* 46450 20 220 110150* 47290 7 364 162225 x 225 47830 660 325300 x 300 48250 790 400REDUCING TEE F & F (without cap)225 x 100 47810 500 230225 x 150 47820 545 270300 x 150 48230 640 325INSPECTION TEE F & F (includes cap)100 x 100* 46440 20 220 120 1 cap150 x 150* 47280 7 364 162225 x 150 47870 545 250300 x 150 48300 640 280TEE M & F (without cap)100* 46480 20 220 100 Threaded150* 47310 7 350 162REDUCING TEE M & F (without cap)225 x 100 47840 500 250*Moulded fitting, all other products are custom fabricated.Note: All fittings are custom fabricated unless otherwise specified8<strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> -


<strong>DWV</strong> Sewer Pipe SCJNom. size Angle Code Qty per L1 L2 Type(mm) carton (mm) (mm)INSPECTION TEE M & F (includes cap)100* 46500 20 220 120 2 caps100 x 100* 46470 20 219 122150 x 150* 47300 7 350 167300 x 150 48310 640 280ACCESS COUPLING F & F (without cap)100* 46380 50 107150* 47240 18 186ACCESS COUPLING M & F (without cap)150* (no cap) 47250 18 215 RRJ-Spigot150* (with cap) 47260 12 250 RRJ-SpigotTHREADED ACCESS CAP100* 46430 45 133 31150* 47270 40 175 35PUSH ON CAPS100* 46650 110 114 29150* 47380 40 169 42225 47990 8 265 175300 48450 3 330 220375 48990 420 320PLAIN/STRAIGHT COUPLING F & F225 47940 320300 48390 420375 48930 810*Moulded fitting, all other products are custom fabricated.Note: All fittings are custom fabricated unless otherwise specified<strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> -9


<strong>DWV</strong> Sewer Pipe SCJNom. size Angle Code Qty per L1 L2 Type(mm) carton (mm) (mm)REPAIR COUPLING F & F100 58250 35 127 110150 58260 12 185 165SLIP COUPLING (RRJ)100* 50220 35 143150* 50520 12 245LEVEL INVERT TAPERS M & F150 x 100* 47340 20 233225 x 100 47900 430225 x 150 47910 415300 x 225 48350 520375 x 225 48870 688375 x 300 48880 770DISCONNECTOR TRAP ASSEMBLY (FIXED) F & F100* 46510 10 447 232150 47325 2 460 55090 o D.T. RISER F & F100 x 50* 46560 36 175 95100 x 50 x 50* 46565 20 197 9590 o D.T. 4 – WAY RISER M & F100 x 50 x 50 x 50 x 40* 46570 20 210 95100 x 50 x 50 x 40 x 40* 46575 20 210 95SEWER BOUNDARY TRAP F & F100* 46510 10 447 232*Moulded fitting, all other products are custom fabricated.Note: All fittings are custom fabricated unless otherwise specified10<strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> -


<strong>DWV</strong> Sewer Pipe SCJNom. size Angle Code Qty per L1 L2 Type(mm) carton (mm) (mm)SOCKET PLUGS100* 46653 30 110150* 47390 12 110FLANGES(Drilled to AS2129 – Table C and includes metal backing ring)225 47950 220 Socket300 48400 310 Socket300 48410 250 SpigotSLEEVE - PVC SPIGOT TO A.C. SOCKET ADAPTOR100 47500 90150 47550 95SEWER VERTICAL BACKDROP100 47520150 47590SEWER SADDLE150/100 45 o 47546 300 315 MMBW - 58225/100 45 o 47775 360 315 MMBW - 59225/150 45 o 47777 420 335 MMBW - 60*Moulded fitting, all other products are custom fabricated.Note: All fittings are custom fabricated unless otherwise specified<strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> -11


PVC Downpipe SystemSolvent Cement Joint375 M/S Shroud x 0.3(VX Product Code 59214)DI Cover with Concrete Surround(VX Product Code 53161)225 Access Cap SWJ(VX Product Code 52975)225 x 3m <strong>DWV</strong> Pipe(VX Product Code 19200)Maintenance ShaftMAINTENANCE SHAFTNom. size Code Description Hand(mm)150 x 150 52931 In-Line M/S W/Cap SWJ225 x 225 52934 In-Line M/S W/Cap SWJ150 x 225 52937 In-Line M/S W/Cap SWJ150 x 150 52979 Shaft Elbow W/Cap SWJ 15° Left150 x 150 52980 Shaft Elbow W/Cap SWJ 15° Right150 x 150 52962 Shaft Elbow W/Cap SWJ 22.5° Left150 x 150 52963 Shaft Elbow W/Cap SWJ 22.5° Right150 x 150 52960 Shaft Elbow W/Cap SWJ 30° Left150 x 150 52961 Shaft Elbow W/Cap SWJ 30° Right150 x 150 52965 Shaft Elbow W/Cap SWJ 45° Left150 x 150 52966 Shaft Elbow W/Cap SWJ 45° Right150 x 150 52989 Shaft Elbow W/Cap SWJ 60° Left150 x 150 52990 Shaft Elbow W/Cap SWJ 60° Right150 x 150 52959 Shaft Elbow W/Cap SWJ 90° Left150 x 150 52958 Shaft Elbow W/Cap SWJ 90° Right150 52964 Terminal Elbow W/Cap SWJ 90°150 65129 Ultra-Rib to PVC Converter150 50540 Pipe Socket RRJ12 <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> -


PVC Downpipe SystemSolvent Cement JointCode Size Qty PerCartonPRIMING FLUID - RED82341 250ml 3682342 500ml 2082343 1 litre 1282344 4 litre 482345 20 litre 1Please note: Clear solvent cements andpriming fluid may also be available.Contact your nearest Vinidex office fordetails. Always use the correct solventcement for the application.Average number of joints per 500mlThe following table provides anindication as to the number of jointsthat are made per 500ml container ofpriming fluid and solvent cement.For the use of pressure & non-pressure applicationsTYPE ‘N’ SOLVENT CEMENT - BLUE82430 125ml 3682432 250ml 3682434 500ml 2082436 1 litre 1282438 4 litre 4For the use in non-pressure applicationsTYPE ’P’ SOLVENT CEMENT – GREEN82420 125ml 3682422 250ml 3682424 500ml 2082426 1 litre 1282428 4 litre 4For use in pressure including potable water, applicationsSize of pipe DN (mm) 15 20 25 32 40 50 65 80Priming Fluid 1050 625 450 325 250 150 125 100Solvent Cement 300 175 130 95 70 42 35 30Size of pipe DN (mm) 100 125 150 200 225 250 300 375Priming Fluid 70 60 45 25 15 12 12 12Solvent Cement 25 20 15 10 7 6 5 5<strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> -13


Maintenance ShaftStandard Symbol GuideSpigot & Socket –Solvent Weld Joint Pipe (SCJ)45 o Bend (SCJ)Tee (SCJ)15 o Bend (SCJ)Tee, Spigot (SCJ)90 o Bend (SCJ)Inspection Tee,Cap on Branch (SCJ)Inspection Tee, Spigot,Cap on Branch (SCJ)Side Access Bend (SCJ)90 o Bend, Rear Access (SCJ)Level Invert 45 o45 o Bend, Spigot (SCJ)Junction (SCJ)Slip Coupling45 o Junction, Spigot, (SCJ)Access Coupling45 o Junction, Spigot, Side Access (SCJ)Plain CouplingDouble Junction – (SCJ)Push Cap90 o Junction (SCJ)Threaded Cap90 o Junction, Spigot (SCJ)Connector & Cap90 o Junction, Rear Access (SCJ)Socket PlugFlangeAdaptor Collar14 <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> - SCJ <strong>DWV</strong> <strong>Systems</strong> -


NATIONAL OFFICEPO Box 4990North Rocks NSW 2151TEL: (02) 9604 2422FAX: (02) 9604 1078SYDNEY254 Woodpark Rd,Smithfield NSW 2164TEL: (02) 9604 2422FAX: (02) 9604 4435MELBOURNE86 Whiteside Rd,Clayton VIC 3168TEL: (03) 9543 2311FAX: (03) 9543 7420BRISBANE224 Musgrave Rd,Coopers Plains QLD 4108TEL: (07) 3277 2822FAX: (07) 3277 3696TOWNSVILLE49 Enterprise Ave,Bohle QLD 4816TEL: (07) 4774 5044FAX: (07) 4774 5728ADELAIDE550 Churchill Rd,Kilburn SA 5084TEL: (08) 8260 2077FAX: (08) 8349 6931PERTHSainsbury Rd,O’Connor WA 6163TEL: (08) 9337 4344FAX: (08) 9331 3383DARWIN3846 Marjorie St,Berrimah NT 0828TEL: (08) 8932 8200FAX: (08) 8932 8211LAUNCESTON15 Thistle St,South Launceston TAS 7249TEL: (03) 6344 2521FAX: (03) 6343 1100HOTLINE 13 11 69E-mailinfo@vinidex.com.auWebsitewww.vinidex.com.auVINIDEX PTY LTDABN 42 000 664 942VIN019