17.07.2015 Views

In-Slab Tank - Savewater.com.au

In-Slab Tank - Savewater.com.au

In-Slab Tank - Savewater.com.au

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical Sheet: <strong>In</strong>-<strong>Slab</strong> <strong>Tank</strong>SpecificationsEach rigid tank is made from rotational-molded Polyethylene.The <strong>In</strong>-<strong>Slab</strong> tank has been tested in accordance withAS3610-1995 relating to the structural capacity of a tank towithstand the applied load of the concrete duringconstruction. The assessment of the tank in accordancewith AS3610-1995 was conducted by Cardno, a leader inFEA (Finite Element Analysis).<strong>Tank</strong> CapacityA single Rain Reviva <strong>In</strong>-<strong>Slab</strong> tank has a 660 litre capacity.The number of rigid tanks that can be incorporated into theslab is limited only by the size and type of slab. The uniquedesign of the rigid tank allows for multiple units to beinstalled in a collective group, increasing the overall capacityof the <strong>com</strong>bined tank system.Dimensions<strong>In</strong>-<strong>Slab</strong> <strong>Tank</strong> DesignThe <strong>In</strong>-<strong>Slab</strong> tank has been designed by engineersincorporating all the relevant requirements relating tostrength, thermal and other related considerations.The patented <strong>In</strong>-<strong>Slab</strong> tank design is <strong>com</strong>pliant with BuildingCode of Australia – Residential <strong>Slab</strong>s and Footings-Construction AS2870-1996. <strong>In</strong>-<strong>Slab</strong> tanks are manufacturedunder strict ISO/9001.2000 Standards.Constructed from polyethylene, the tank is designed in sucha way that it can be used as the formwork within the slab.WarrantyAll Rain Reviva <strong>In</strong>-<strong>Slab</strong> tanks are backed by 10 year moneyback guarantee.Design ProcessUsing the plans from the architect/designer/builder, NewWater will make re<strong>com</strong>mendations as to the positioning ofthe rigid tanks within the dwelling’s slab to optimise thecapture of rainwater.Upon the tank positioning being approved by thearchitect/designer/builder, New Water will then customisethe system package for the dwelling.New Water will supply the tanks with all necessary fittings to<strong>com</strong>plete the installation.Applicable RebateYour clients may be eligible for a rebate from their state orlocal government – check with your New Water consultantto determine which rebates are applicable in utilising the<strong>In</strong>-<strong>Slab</strong> tank solution.Page 2 of 4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!