17.07.2015 Views

Title 15 BUILDINGS AND CONSTRUCTION ... - City of Sand City

Title 15 BUILDINGS AND CONSTRUCTION ... - City of Sand City

Title 15 BUILDINGS AND CONSTRUCTION ... - City of Sand City

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Exception:(1) Trash areas adjacent to solid brick or concrete walls with no openings or eaves are notrequired to be protected by automatic sprinkler system(s).<strong>15</strong>.08.090 Section 307 Amended.Section 307 - Incinerators, Open Burning and Commercial Barbecue Pits.Open BurningSection 307. General. Open burning shall be prohibited including the outdoor rubbish fires andbonfires, unless (1) the fire is confined to an approved incinerator as defined by the UniformMechanical Code and authorized by the Monterey Bay Air pollution Control District, (2) theopen fire is for the explicit purpose <strong>of</strong> preparation <strong>of</strong> food, such as in the case <strong>of</strong> a luau,barbecue, and the like, or (3) open fire rings or 2-ft by 2-ft by 2-ft warming fires are locatedwithin the coastal beach areas, excluding fenced <strong>of</strong>f sensitive habitat areas, at a minimumdistance <strong>of</strong> fifty (50) feet from any habitable structure and are under constant attendance, (4) gasfueled factory manufactured / industry safety certified fire-pits, and (5) a special condition orcircumstance exists and written authorization is granted by the Fire Chief and/or Police Chief.<strong>15</strong>.08.100 Section 316 Amended. Section 316 - Storage <strong>of</strong> Idle Pallets.Section 316.1. General. The requirements <strong>of</strong> this section apply to all pallets, whether wood orplastic.<strong>15</strong>.08.110 Section 503.2.6.1 Added.503.2.6.1 Private Bridge Engineering. Every private bridge hereafter constructed shall meet thefollowing engineering requirements:a. The weight shall be designated for a minimum <strong>of</strong> HB-17 loading as prescribed by theAASHTO.b. The unobstructed vertical clearance shall be not less than fifteen feet (<strong>15</strong>') clear.c. The width shall be a minimum <strong>of</strong> twenty feet (20') clear. The fire code <strong>of</strong>ficial may requireadditional width when the traffic flow may be restricted or reduce the width to a minimum <strong>of</strong>twelve feet (12') for Occupancy Group U or R-1 occupancies.d. The maximum grade change <strong>of</strong> the approach to and from any private bridge shall not exceedeight percent (8%) for a minimum distance <strong>of</strong> ten feet (10').<strong>15</strong>.08.120 Section 503.2.6.2 Added.503.2.6.2. Private Bridge Certification. Every private bridge hereafter constructed shall beengineered by a licensed pr<strong>of</strong>essional engineer knowledgeable and experienced in the

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!