illiant spectroscopy <strong>PRODUCT</strong> <strong>CATALOGUE</strong>2011www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | ContentsContentsINTRODUCTION........................................................3SILVER GATE EVOLUTION ATR............................. 62<strong>PRODUCT</strong> SELECTOR........................................... 6/7INFRARED TRANSMISSION SPECTROSCOPY..... 9GATEWAY ATR SYSTEM....................................... 64GATEWAY TOP PLATE OPTIONS............................. 65TRANSMISSION SPECTROSCOPY INTRODUCTION.. 1025 REFLECTION ATR...............................................67THE OMNI-CELL SYSTEM...................................... 11WINDOW POLISHING KIT.......................................... 14VARIABLE PATHLENGTH CELL................................ 15SAMPLE CELL HOLDERS INTRODUCTION............... 16THE SELECTOR.................................................... 68ENVIRONMENTAL CHAMBER FOR SELECTOR..... 69MINIDIFF PLUS...................................................... 70MONOLAYER GRAZING ANGLE............................... 71LIQUID SAMPLING CELLS........................................FLOW CELLS FOR VARIABLE TEMP CELL17SPECULAR REFLECTANCE ACCESSORY 30˚........... 73ACCESSORIES FOR SAMPLE PREPARATION.... 75& HEATINGS JACKETS............................................. 19FLOW CELLS FOR HEATING JACKETS.................... 20ACCESSORIES FOR SAMPLE PREPARATIONINTRODUCTION....................................................... 76HIGH PRESSURE LIQUID CELL................................. 21PRESS CHOICE INTRODUCTION.............................77SPECTROELECTROCHEMICAL CELL....................... 22ATLAS 15T & 25T MANUAL HYDRAULIC PRESS... 78THE VARIABLE TEMPERATURE CELL HOLDER....... 23ATLAS LOW TONNAGE CONVERSION KITS.........79ELECTRICAL HEATING JACKET............................... 25ATLAS POWER PRESSES...................................... 80WATER HEATING JACKET.......................................OIL IN WATER ANALYSIS KIT...................................2627ATLAS AUTO HYDRAULIC PRESSES...................... 81EVACUABLE PELLET DIES....................................... 83DC-2 DIAMOND COMPRESSION CELL.................... 28MICROFOCUS BEAM CONDENSER......................... 29MICRO COMPRESSION CELL.................................. 30ATLAS LIGHTWEIGHT DIES................................... 85SPECADIE............................................................. 86VACUUM PUMP SYSTEM......................................... 87STORM 10cm GAS CELLS.....................................31HEATED PLATENS................................................... 88STORM 10cm HEATED GAS CELL......................... 32CYCLONE GAS CELLS.......................................... 33CONSTANT THICKNESS & H.T. FILM MAKER.......... 89SPECAMILL........................................................... 92TORNADO GAS CELLS.........................................HIGH TEMP / HIGH PRESSURE CELL39SPECACABINET.................................................... 93SPECACARDS & MAGNETIC FILM HOLDER............ 94FOR EXTREME CONDITION ANALYSIS.................... 44FTIR STARTER KIT.................................................... 95POLARIZERS INTRODUCTION.................................46PROFESSIONAL STARTER KIT.................................96FTIR INFRARED POLARIZERS.................................. 47STANDARD INFRARED POLARIZERS....................... 48SPECAC PROCESS CAPABILITIES.....................PROCESS CAPABILITIES INTRODUCTION...............9798HER INFRARED POLARIZERS.................................. 49IMAGE QUALITY INFRARED POLARIZERS............... 50PROCELL CASCADE............................................. 99PROCELL VORTEX................................................ 99OPTO-PHYSICS POLARIZERS..................................51PROCELL TYPHOON........................................... 100ROTATABLE POLARIZER MOUNTS.......................... 52INFRARED REFLECTANCE SPECTROSCOPY.... 53INFRARED REFLECTANCE SPECTROSCOPYINTRODUCTION....................................................... 54GOLDEN GATE DIAMOND ATR............................. 55GOLDEN GATE TOP PLATE OPTIONS................... 58MINI PROBE............................................................ 101SPECTROSCOPIST’S HINTS & TIPS.................. 102INDEX..................................................................... 105A - Z OF IR............................................................. 106OPTICAL MATERIALS FOR SPECTROSCOPY.... 111CONTACT US.......................................................... 112www.specac.com3


<strong>Specac</strong> Product Catalogue 2011 | Introduction<strong>Specac</strong> manufactures high quality IR & FTIR productsengineered to meet your needs and built to last.Welcome to the <strong>Specac</strong> Catalogue 2011 whichincludes all of the additions we have made overthe last year.At <strong>Specac</strong> we pride ourselves on offering highspecification, high quality accessories into the IRand FTIR market and we hope that you willcontinue to see the benefit of using <strong>Specac</strong>products for your sampling applications.We are striving to improve our customer serviceand responsiveness to the market. For the latestnews on promotions and new products pleasevisit our website at www.specac.com.If you would like to comment on this catalogue orany other customer service issues please emailus at customer.feedback@specac.co.ukOur next catalogue will be published January 2012.Satisfying our customers’ expectations<strong>Specac</strong> delivers quality products engineered tomeet your needs. Our accessories are easyto-useand built to last. From thin plastic filmpreparation accessories used for routine qualitychecks, to sophisticated, fibre-optic-coupled,remote sampling systems for reaction monitoring,<strong>Specac</strong> has the experience to provide the idealsampling solution. Even if your application is notstandard, you can draw upon the resources ofour optical and mechanical engineering experts,as well as our specialist team of spectroscopiststo satisfy your sampling requirements.Our service to you doesn’t stop there. We backour products with technical support and expertise.Whether you need advice in determining the bestaccessory for your application, or assistance withalignment or operation, a network of customersupport representatives is on hand worldwide.Last, but not least, is cost. <strong>Specac</strong> continuallyseeks to improve the quality of its products andservices, and to maintain competitive prices,through cost engineering and investment in thelatest technology. Cost effectiveness and durabilityare built-in to every product. This maximizessampling flexibility by allowing you to expand youraccessories as your sampling needs change.If you are involved with FTIR analysis <strong>Specac</strong> candeliver quality accessories, giving you genuinevalue for money. Join our many loyal and satisfiedcustomers who choose <strong>Specac</strong> to deliver.David Smith, Managing DirectorWhatever your application - you can be sure that wealready have the ideal sampling solution.brilliant spectroscopy 4www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | New Products / Catalogue KeyNew products for 2011<strong>Specac</strong> is committed to extending and enhancing its range of productsand in this latest edition of our catalogue we’ve added the following products...NEW40 Ton Automatic pressThis press is a 40 Ton version of our 8T and 25Tautomatic presses. It has all the same featuresand benefits as these presses and has beingdesigned for use in the XRF industry.15 Ton Power and Automatic pressesThese presses are a 15 Ton version of our 8T and25T power and automatic presses with all thesame features and benefits. They are designedfor customers who don’t require a 25 ton loadbut would still like the ease of use that the powerand automatic presses provide.ThermocirculatorThis is a suggested product for use where anaccessory that requires water cooling or heatingis not situated near a water supply. The use ofthis product prohibits the need to run longlengths of tubing or having to keep movingequipment.Vacuum KitThis accessory can be used wherever a vacuumis required. The kit includes all the connectionsrequired in order to evacuate any <strong>Specac</strong>accessory.Essential Spares Kits (ESK’s)These kits have being added to specificaccessories so that if a particular screw, washeror O-ring is lost or damaged it can be replacedfrom the kit and minimise the time delay in gettingthe accessory back to its proper workingcondition.4000 series controller connectivityOn our 4000 series controllers there is an optionfor the controller to be operated automatically bycomputer via RS232, RS485 or USB connectivity.The 4000 series controllers are supplied asstandard without any communication port fittingsbut the appropriate connectivity options can befitted if requested.Key to catalogue symbol usageThe symbols below indicate the service requirements for <strong>Specac</strong> accessoriesELECTRICElectric power is required forthis accessoryVACUUMVacuum Pump kit required forthis accessoryCooling water required forWATER 5 ltrthis accessory (Thermocirculatorpump with 5 litre bathP/N GS11127 can be offered)GASGases are used withthis accessoryCooling water required forWATER 12 ltrthis accessory (Thermocirculatorpump with 12 litre bathP/N GS11128 can be offered)ESKEssential spares kit is offeredwith this accessoryWater heating required for thisWATER 5 ltraccessory (Thermocirculatorpump with 5 litre bathP/N GS11127 can be offered)COMMSCommunications option on the4000 Series Controller is availablewith this accessorywww.specac.com5


<strong>Specac</strong> Product Catalogue 2011 | Product Selector<strong>Specac</strong> Product SelectorFor any virtually any sample type, there is a <strong>Specac</strong> accessory for either the transmissionor reflection technique. This table will help you identify the best accessory for your samplingapplication and shows which accessories can be used for various sample types undervarious conditions.Key★ Ideal for application❖ May be suitable;(contact <strong>Specac</strong>for further details)■ Requires additionalaccessorySolidPowderLiquidGasAdvancedResearchFlat / SmoothRough / AbrasiveHigh TemperatureLow TemperatureHigh PressureFInely GroundCoarse / CrystalineHigh TemperatureLow TemperatureHigh PressureFixed PathlengthVariable PathlengthAmbient ConditionsFlow ExperimentsHigh PressureHigh TemperatureLow TemperaturepH 11Fixed PathlengthVariable PathlengthHigh PressureHigh TemperaturepH 11ReactionCatalysisSupercriticalPart NumberSpectral RangeOmni Cellmullmull★★★★★★★★★★★★★★★★★★★★★★★★★★gum❖ ❖ ★ ★ ★❖★❖★❖★★★★ ★★ ★❖ ❖GS01800SeriesVariablePathlength CellLiquid CellsHigh PressureLiquid CellsSealed HeatableCellTransmissionSolid CellsDemountableHeatable CellSolids Holder★❖★★❖★DC Cell & MicrofocusBeam CondenserGS07500 GS05910GS20500 GS20510 GS20600GS20610 GS02550GS05000Series Series GS02560GS242XX GS241XX GS05800GS05670IR/Vis/UV★★★❖TornadoGas CellsCycloneStorm6www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Product SelectorKey★ Ideal for application❖ May be suitable;(contact <strong>Specac</strong>for further details)■ Requires additionalaccessorySolidPowderLiquidGasAdvancedResearchFlat / SmoothRough / AbrasiveHigh TemperatureLow TemperatureHigh PressureFInely GroundCoarse / CrystalineHigh TemperatureLow TemperatureHigh PressureFixed PathlengthVariable PathlengthAmbient ConditionsFlow ExperimentsHigh PressureHigh TemperatureLow TemperaturepH 11Fixed PathlengthVariable PathlengthHigh PressureHigh TemperaturepH 11ReactionCatalysisSupercriticalPart NumberSpectral RangeGolden Gate★★★❖★❖★★★★★ ★ ★★ ❖ ❖★★★★★★ ★ ★★★★ ★❖★★★❖ ❖ ❖❖★Silver GateEvolutionATRGatewayReflectionDiffuse25R★❖❖MiniDiff Plus❖★★★❖★★★★★★★★ ★ ★★★❖★❖★❖★★ ★ ★GS10500 GS10680 GS11165 GS11000 GS04510 GS19900 GS19820 GS19650 GS05850GS05855Far/Mid IRSelector❖★Specular30° Fixed AngleUnitMonolayerGrazing AngleHTHP Cell★★★★★❖❖❖❖❖★★Additional accessory options where indicatedGolden Gate Advanced ApplicationsGS10642 High Temperature Golden Gate GS10507 Reaction Cell Top PlateGS10514 Specular ReflectanceGS10566 Germanium Top PlateGS10585 Super Critical Top PlateGS10590 Low Temp. Top PlateSelector Liquid CellsCycloneEnvironmental ChamberGS19930Variable Temperature Cell HolderGS21525, GS21530Electrical Heating JacketGS20730Cyclone Cell Heating JacketGS24302/05/10www.specac.com7


InfraredTransmissionSpectroscopywww.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Transmission Spectroscopy IntroductionTransmission Spectroscopy IntroductionTransmission spectroscopy is the oldest and simplest technique for analyzing samples inthe infrared.Transmission SpectroscopyTransmission spectroscopy is the oldest andsimplest technique for analyzing samples in theinfrared.This method of analysis is based upon theabsorption of the infrared beam by a sample atspecific wavelengths. Different compounds eachdisplay a unique infrared spectrum allowing themto be identified.The extent of absorption ‘A’ is defined by theBeer-Lambert Law: A=abc where ‘A’ is theabsorptivity coefficient, ‘b’ is the pathlength, and‘c’ is the concentration. This law enablesscientists to use infrared data to determinequantitative information.Small amounts of sample can be analyzed byusing an appropriate microsample holder inconjunction with a beam condenser.LiquidsIn transmission spectroscopy, liquids areanalyzed as a thin film sandwiched between twowindows in a liquid cell. The type of cell, choice ofwindow material, and pathlength is determinedby the sample. Samples can be analyzed neat, ordiluted with an appropriate solvent. In order toperform quantitative analysis, the sample shouldbe analyzed in a cell with a known pathlength.A guide to pathlength selection for differentconcentrations in the mid infrared is shownbelow.AnalyticalConcentrationTypicalPathlengthSolidsA variety of methods exist for analyzing solidsamples by transmission spectroscopy. Thinpolymer films can be analyzed directly by using afilm holder.Transmission spectra of solids can also beobtained by grinding the sample together with aninfrared transparent matrix, such as KBr, andpressing the resulting powder into a thin disk.Another method of analyzing solids is to make amull by combining the sample with a liquidparaffin, such as Nujol, and placing it betweentwo infrared transparent windows.A diamond compression cell is available fortransmission studies of single fibres and othermicro samples.GasesGases have densities several orders ofmagnitude lower than liquids and solids atstandard temperature and pressure.Therefore, transmission spectroscopy of gasesrequires cells with a longer pathlength than thoseused for liquid or solid analyses, usually 10 cm orlonger.Low concentrations of gases require apathlength of several meters. This is achieved ina short space by using a multi-pass cell, wherethe infrared beam is bounced through the sampleseveral times in order to obtain the desiredpathlength.> 10 %10 % – 1 %1 % – 0.1 %< 0.1 %0.05 mm0.1 mm0.2 mm> 0.5 mmwww.specac.com10


<strong>Specac</strong> Product Catalogue 2011 | Omni Cell SystemOmni Cell SystemA Universal Transmission Cell for the analysis of liquids and mulls in FTIR orDispersive SpectroscopyOmni Cell SystemThe Omni Cell System is a low cost novelapproach to the analysis of liquid samples intransmission spectroscopy - one cell is suitablefor all applications.The cells are compatible with all FTIRSpectrometers as well as older dispersivesystems and can easily be configured for use asdemountable liquid cells, permanently sealedliquid cells or as mull cells.Transmission is a well established technique foranalyzing samples in the infrared. The choice ofwindow material, pathlength and windowconfiguration are determined by the sample andwavelength range of interest. Samples can beanalyzed neat or diluted with an appropriatesolvent. For quantitative analysis, the sample isoften analyzed in a cell with a known pathlength.A guide to the selection of the correct pathlengthfor various concentrations is given below:AnalyticalConcentration> 10 %10 % – 1 %1 % – 0.1 %< 0.1 %TypicalPathlength0.05 mm0.1 mm0.2 mm> 0.5 mmSolid samples can be analyzed using the mulltechnique. The solid is combined with a mullingagent such as Nujol, and/or Flourolube to form amull which is analyzed between circular windows.Key Features• Quick to assemble and change windows• Windows and Spacers compatible witholder <strong>Specac</strong> cells• FTIR and Dispersive compatibility• Quick release clamping mechanism• Low cost and reliable• Wide choice of window materialsApplicationsDemountable Cells• General Purpose• All liquids• Quantitative analysisSealed Cells• Volatile liquids• Quantitative applications• Low viscosity liquidsMull Cells• High viscosity liquids• Gels and pastes• Oils and greases• Solids suspended as mullsAll cells are shipped as a kit of parts and requireassembly by the user.www.specac.com11


<strong>Specac</strong> Product Catalogue 2011 | Omni Cell SystemOmni Cell SystemDemountable CellThis is a general-purpose cell for all liquids. It hasthe advantage of being easy to dismantle forcleaning, and for changing windows and spacers.Applications• General purpose• All liquids• Quantitative analysisSealed CellThe window pair and spacer are amalgamated asan assembly. The advantages of this cell are aconstant pathlength for quantitative analysis andsuitability for use with volatile liquids.Applications• Volatile liquids• Quantitative applications• Low viscosity liquidsMull CellThe Mull Cell does not use the standard liquidfilling ports. The sample is placed directly ontoone of the circular windows and the otherwindow is then placed on top. The advantage isthat very viscous liquids, gels and pastes caneasily be analyzed.Applications• High viscosity liquids• Gels and pastes• Oils and greases• Solids suspended as mullsOrdering informationOrdering an Omni Cell is easy - just order theUniversal Omni Cell Body, and buy the windowsand spacers to suit your application.Universal Omni-Cell BodyGS01800 The Omni Cell Body.Includes front and back plates,cell nest, 4 quick release nuts,bonded front PTFE gasket, rearneoprene gasket and 2 PTFELuer plugs.www.specac.com12


<strong>Specac</strong> Product Catalogue 2011 | Omni Cell System Ordering InformationOrdering informationDemountable Liquid Omni Cell Window Pairs(Rectangular) 41mm x 23mmGS01810 NaCl Liquid Omni WindowsGS01811 KBr Liquid Omni WindowsGS01812 CaF2 Liquid Omni WindowsGS01813 BaF2 Liquid Omni WindowsGS01814* ZnSe Liquid Omni WindowsGS01815 KRS-5 Liquid Omni WindowsGS01816 CsI Liquid Omni WindowsGS01817 CsBr Liquid Omni WindowsGS01818* Silica (IR) Liquid Omni WindowsGS01819* AgBr Liquid Omni WindowsGS01820* Silicon Liquid Omni WindowsGS01821* Polythene Liquid Omni WindowsLiquid Omni Cell Spacers (Rectangular)GS01850 0.05mm PTFE Spacers (5)GS01851 0.10mm PTFE Spacers (5)GS01852 0.20mm PTFE Spacers (5)GS01853 0.50mm PTFE Spacers (5)GS01854 1.00mm PTFE Spacers (5)GS01855 0.025mm Lead Spacers (5)GS01856 0.05mm Lead Spacers (5)GS01857 0.10mm Lead Spacers (5)GS01858 0.20mm Lead Spacers (5)GS01859 0.50mm Lead Spacers (5)GS01860 1.00mm Lead Spacers (5)GS01861 0.006mm Mylar Spacers (5)GS01862 0.012mm Mylar Spacers (5)GS01863 0.025mm Mylar Spacers (5)GS01864 Assorted PTFE Spacers (10)2 of each thickness suppliedMull Omni Cell Window Pairs(Circular) 25mm DiaGS01830 NaCl Mull OmniwindowsGS01831 KBr Mull Omni WindowsGS01832 CaF2 Mull Omni WindowsGS01833 BaF2 Mull Omni WindowsGS01834* ZnSe Mull Omni WindowsGS01835 KRS-5 Mull Omni WindowsGS01836 CsI Mull Omni WindowsGS01837 CsBr Mull Omni WindowsGS01838* Silica (IR) Mull Omni WindowsGS01839* AgBr Mull Omni WindowsGS01840* Silicon Mull Omni WindowsGS01841* Polythene Mull Omni WindowsMull Omni Cell Spacers (Circular)GS01870 0.05mm PTFE Spacers (5)GS01871 0.10mm PTFE Spacers (5)GS01872 0.20mm PTFE Spacers (5)GS01873 0.50mm PTFE Spacers (5)GS01874 1.00mm PTFE Spacers (5)GS01875 0.025mm Lead Spacers (5)GS01876 0.05mm Lead Spacers (5)GS01877 0.10mm Lead Spacers (5)GS01878 0.20mm Lead Spacers (5)GS01879 0.50mm Lead Spacers (5)GS01880 1.00mm Lead Spacers (5)GS01881 0.006mm Mylar Spacers (5)GS01882 0.012mm Mylar Spacers (5)GS01883 0.025mm Mylar Spacers (5)*These windows require additional spacerP/N GS01893Permanently Sealed Omni Cell Window Units(Rectangular with Lead Spacer)These Sealed Cell Assemblies are used in theOmni-Cell Body P/N GS01800Material 0.025 mm 0.05mm 0.10mm 0.20mm 0.50mm 1.00mmNaCl GS01910 GS01920 GS01930 GS01940 GS01950 GS01960KBr GS01911 GS01921 GS01931 GS01941 GS01951 GS01961CaF2 GS01912 GS01922 GS01932 GS01942 GS01952 GS01962BaF2 GS01913 GS01923 GS01933 GS01943 GS01953 GS01963ZnSe* GS01914 GS01924 GS01934 GS01944 GS01954 GS01964KRS-5 GS01915 GS01925 GS01935 GS01945 GS01955 GS01965Csl GS01916 GS01926 GS01936 GS01946 GS01956 GS01966CsBr GS01917 GS01927 GS01937 GS01947 GS01957 GS01967Silica (IR)* GS01918 GS01928 GS01938 GS01948 GS01958 GS01968SparesGS01110 Luer Syringe (2ml)GS01890 Rear Neoprene Gaskets (2)GS01891 Quick Release Nuts (4)GS01892 Luer Plugs for Omni-Cell (2)GS01893 Spacer for thin windows (1)GS03620 Bottle of Nujol (25ml)GS03621 Bottle of Fluorolube (25ml)All windows are 4mm thick except ZnSe, Silica(IR), AgBr and Si, which are 2mm and Polythene,which are 3mm thick. These windows require theadditional spacer for thin windows P/N GS01893www.specac.com13


<strong>Specac</strong> Product Catalogue 2011 | Window Polishing KitWindow Polishing KitKeep windows in top condition with the <strong>Specac</strong> Window Polishing KitKit Includes• Polishing Selvyt• Polyethylene bottle• Cleaning sponge• Bottle of polishing rouge• Plain Selvyt strips• Lapping paper• BrushesWindow Polishing KitThis kit contains all the essential materialsrequired to clean and repolish windows to aflatness within a few fringes. It is especiallyeffective in use with window materials such asNaCl and KBr. Repolishing can be achievedefficiently and economically with a minimumdegree of skill.Full instructions are included and all consumableparts are replaceable.Ordering InformationWindow Polishing KitGS04000 Polishing Kit CompleteGS04010 Polishing Selvyt(self adhesive pads) (5)GS04040 Polyethylene bottle (2)GS04050 Cleaning sponge (1)GS04060 Bottle of polishing rouge(approx 75g net)GS04080 Plain Selvyt strips (2)(non adhesive)GS04090 Lapping paper (5)GS04095 Brushes (2)www.specac.com14


<strong>Specac</strong> Product Catalogue 2011 | Variable Pathlength CellVariable Pathlength CellCells that allow adjustment of sample pathlength in situThe windows of the cell do not rotate in relationto the movement of the outer sleeve capassembly with the cell body and hence remainparallel to each other throughout the pathlengthrange. Choice of window materials allows for thestudy of many liquid sample types and there is astandard 3” x 2” mount fixing, such that the cellcan be used in a very wide range ofspectrometer systems.Key Features• Continuous adjustment of samplepathlength• Micrometer and vernier scales foraccurate pathlength setting and readability• Standard 3” x 2” slide mounting• Non-rotating windows• Pathlength variation: 0.04-6mm• Scale division: 5µm• Volume at maximum pathlength: 6mlApplications• Liquid analysis without dilution• Determination of absorption coefficientOrdering InformationVariable Pathlength Liquid CellGS07500 Variable Pathlength Cell withNaCl windowsGS07501 Variable Pathlength Cell withKBr windowsGS07502 Variable Pathlength Cell withCaF2 windowsGS07503 Variable Pathlength Cell withBaF2 windowsGS07509 Variable Pathlength Cell withZnSe windowsReplacement Windows for 7500 SeriesGS07020 Set of NaCl windowsGS07021 Set of KBr windowsGS07022 Set of CaF2 windowsGS07023 Set of BaF2 windowsGS07024 Set of CSi windowsGS07025 Set of CsBr windowsGS07026 Set of KRS-5 windowsGS07027 Set of Fused Silica (IR)GS07028 Set of AgBr WindowsGS07095 Set of Polyethylene windowsGS07096 Set of ZnSe windowsGS07097 Set of Silicon WindowsVariable Pathlength Liquid CellThe Variable Pathlength Cells P/N GS07500Series allow for liquids to be studied over a rangeof pathlengths obtainable from one cell.The pathlength range is adjustable from0.040mm to 6.000mm in increments of 0.005mmby anticlockwise rotation of an outer sleeve capassembly about the cell body that separates thewindows of the cell. Micrometer and vernierscales are marked on the cell body for accuratepathlength setting and readability.OptionsGS01110 Luer syringe (2ml)GS07130 Neoprene gaskets for 7500series (10)GS07135 Luer plug and reservoir cap for7500 seriesGS07140 PTFE gaskets (0.1mm) for7500 series (10)GS07150 Spare Window Keywww.specac.com15


<strong>Specac</strong> Product Catalogue 2011 | Sample Cell Holders IntroductionSample Cell Holders IntroductionLiquid and Solid Sample Cell Holders for Variable Temperature, Pressure and Flow Conditions<strong>Specac</strong> offers a range of transmissionaccessories to allow a sample to be studied attemperatures other than ambient. The VariableTemperature Cell holder P/N GS21525 can beused for the temperature range of –190°C to250°C and the Electrical Heating Jacket P/NGS20730 is used for temperatures fromambient to 250°C. Specific sample cell holdersfor liquids and solids are used within theseaccessories. These are known asGS20500/GS20510 Series liquid cells andGS20600 and GS20610 solid cells. Liquid cellsare supplied with windows from a wide range ofmaterials, to suit for specific sampleapplications. (A comprehensive list of IRtransmitting materials and their properties can befound at the back of the <strong>Specac</strong> catalogue.)All of the sample cells can also be operated atambient temperature and pressure when usedwith the 3” x 2” mount sample holder P/NGS20740. For experiments at high pressures,High Pressure Heatable Liquid Flow Cells P/NGS05910 series can be used in the ElectricalHeating Jacket and Variable Temperature Cellholder. These cells are supplied with their own 3”x 2” mounting plate for use in Spectrometers atambient temperature.Solid Sampling CellsChoice of sample sizes from 12mm to 30mm diameter and 0.1mm to 8mm thickP/N GS20600P/N GS20610Solid Sampling CellsThere are two types of solids holder, P/NGS20600 and P/N GS20610. P/N GS20600is used in the Electrical Heating Jacket P/NGS20730. The body has a fixed size aperture of10mm and hence solid samples can be analyzedfrom 12mm to 28mm dia. and up to 3mm thick.P/N GS20610 is used in the VariableTemperature Cell Holder P/N GS21525. Thesolids holder consists of outer and inner cellthreaded bodies and three pairs of pressureplates.The varying aperture sizes of the pressureplates enable samples with a diameter of12 - 17mm, 17 - 22mm and 22 - 30mm andthicknesses of a few microns to 8mm thick tobe analyzed.Both of the solids holders do not require anywindows for operation.Ordering InformationSolids HoldersGS20600 Solids Holder for Heating JacketsP/N GS20730 and P/N GS20710GS20610 Solids Holder for VariableTemperature Cell P/N GS21525Ambient Temperature HolderGS20740 3” x 2” mount holder for allsample cellswww.specac.com16


<strong>Specac</strong> Product Catalogue 2011 | Liquid Sampling CellsLiquid Sampling CellsFor high sensitivity ATR measurements with FT-IR or dispersive instrumentsKey FeaturesP/N GS20500• Choice of pathlength• Sealed or demountable cells• Variety of window materials• Static or flow modes• Luer fittings and stainless steel plugsLiquid Sampling CellsThere are many combinations for liquid cells andthey can be provided as static sealed (P/NGS20500 series), static demountable (P/NGS20510 series), flow sealed (P/N’s GS20560and GS20570 series) and flow demountable(P/N’s GS20580 and GS20590 series)versions.When you order a particular version you willreceive the complete cell with windows of choiceand a spacer at pathlength of choice allassembled together. Sealed cells have a leadspacer and lead top gasket and all componentsare permanently amalgamated/sealed together.Demountable cells have a PTFE spacer and PTFEtop gasket and as such allow for windows andspacer pathlengths to be interchangeable withinthese version cells. A threaded luer fitting,flushing tube, syringe needle, 2 PTFE washersand 3/32” Allen key are also included with thestatic version cells. The liquid is contained withinthe static version of liquid cells (sealed ordemountable) by threaded stainless steel screwplugs.The flow cells (GS20570 and GS20580 series)have an alternative front plate with permanentSwagelok connection fittings for 1/16” tubing.The threaded luer and flushing tube cannot beattached to the flow cell front plate.The P/N’s GS20570 and GS20580 series flowcells are, however, only suitable for use in theElectrical Heating Jacket P/N GS20730. For aliquid flow cell to be accommodated in theVariable Temperature Cell holder P/N GS21525,a different type of front flow plate is used with astatic sealed GS20500 series cell.These versions of flow cells for the VariableTemperature Cell are P/N GS20560 series cells.The flow front plate on these liquid cells has two1/16” stainless steel flow tubes welded to thesample inlet and outlet ports on the plate.The flow tubes are specifically shaped to allowfor a liquid flow cell to fit in the VariableTemperature Cell and be connected via Swagelokfittings to an external liquid supply.<strong>Specac</strong> recommends use of a sealed cell withinthe Variable Temperature Cell holder to offer thebest sealing integrity to contain a liquid samplewhen in the local operating vacuum environment.There are demountable flow cell equivalentversions of these sealed liquid flow cells thatcould be used in the Variable Temperature Cellholder. The flow front plate with stainless steeltubing and Swagelok fittings is attached to thedemountable liquid cells GS20510 series. Thesedemountable flow cells are GS20590 seriestype cells.Either a sealed (GS20560 series) ordemountable (GS20590 series) flow cell can beused in both the Variable Temperature CellHolder and Electrical Heating Jacket. It isimportant to note that the P/N’s GS20570 andGS20580 series flow cells cannot be used inthe Variable Temperature Cell.Please note that in order to use the flow cells inthe Variable Temperature Cell holder the flowoption GS20080 must be fitted.www.specac.com17


<strong>Specac</strong> Product Catalogue 2011 | Liquid Sampling Cells Ordering InformationLiquid Sampling CellsOrdering informationLiquid CellsGS20500* NaCl Sealed Heatable Liquid Cell(Specify pathlength, from 0.025, 0.05, 0.1, 0.2,0.5 and 1.0mm)GS20501* KBr Sealed Heatable Liquid Cell(Specify pathlength, from 0.025,0.05, 0.1, 0.2,0.5 and 1.0mm)GS20502* CaF2 Sealed Heatable Liquid Cell(Specify pathlength, from 0.025,0.05, 0.1, 0.2,0.5 and 1.0mm)GS20503* BaF2 Sealed Heatable Liquid Cell(Specify pathlength, from 0.025,0.05, 0.1, 0.2,0.5 and 1.0mm)GS20508* ZnSe Sealed Heatable Liquid Cell(Specify pathlength, from 0.025,0.05, 0.1, 0.2,0.5 and 1.0mm)GS20510** NaCl Demountable HeatableLiquid Cell(Specify pathlength, from 0.0006, 0.0012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)GS20511** KBr Demountable HeatableLiquid Cell(Specify pathlength, from 0.0006, 0.0012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)GS20512** CaF2 Demountable HeatableLiquid Cell.(Specify pathlength, from 0.0006, 0.0012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)GS20513** BaF2 Demountable HeatableLiquid Cell(Specify pathlength, from 0.0006, 0.0012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)GS20519** ZnSe Demountable HeatableLiquid Cell(Specify pathlength, from 0.0006, 0.0012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)* These cells include a complete cell with frontplate, top lead gasket, top window, lead spacer(choice of pathlength) and bottom window allsealed together** Includes a complete cell with front plate, topPTFE gasket, top window, PTFE or Mylar spacer(choice of pathlengths) and bottom window thatcan be separated from each other*** Please note that 0.006, 0.012 and 0.025mmspacers are only available in Mylar while all othersizes are in PTFE onlyESKWindows for Liquid CellsGS20520 Pair of NaCl windowsGS20521 Pair of KBr windowsGS20522 Pair of CaF2 windowsGS20523 Pair of BaF2 windowsGS20596 Pair of ZnSe windowsGS20598 Pair of Spec B (UV) windowsSpares and Consumables for Liquid CellsGS20040 Front PTFE Gaskets (10)GS20060 Rear PTFE Gaskets (10)GS20050 PTFE and Mylar Spacers Assorted(2 each of 0.006, 0.012, 0.025,0.05, 0.1, 0.2, 0.5 and 1.0mm)GS20070 PTFE and Mylar Spacers (10)(select from 0.006, 0.012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and1.0mm)***GS10030 Flushing Tube KitGS10040 Threaded Luer FittingGS10050 Syringe Needles (10)GS10060 Stainless Steel Plugs (2)GS10070 PTFE Sealing Washers (10)Heatable CellGS20539 Heatable Liquid Static Cells ESKAmbient Temperature HolderGS20740 3” x 2” mount holder for allsample cellsP/N GS20740www.specac.com18


<strong>Specac</strong> Product Catalogue 2011 | Liquid Sampling Cells Ordering InformationFlow Cells for Variable Temperature Cell Holder& Heating JacketsPlease note:- In order to use the flow cells in the Variable Temperature Cell holder (GS21525)the flow option kit GS20080 must be fitted.Ordering informationFlow CellsGS20560*NaCl Sealed Heatable Liquid Cellwith 1/1 6” Swagelok fittings forflow purposes.(Specify pathlength from 0.025, 0.05, 0.1, 0.2,0.5 and 1.0mm)GS20561* KBr Sealed Heatable Liquid Cellwith 1/1 6” Swagelok fittings forflow purposes.(Specify pathlength from 0.025, 0.05, 0.1, 0.2,0.5 and 1.0mm)GS20562* CaF2 Sealed Heatable Liquid Cellwith 1/1 6” Swagelok fittings forflow purposes.(Specify pathlength from 0.025, 0.05, 0.1, 0.2,0.5 and 1.0mm)GS20563* BaF2 Sealed Heatable Liquid Cellwith 1/1 6” Swagelok fittings forflow purposes.(Specify pathlength from 0.025, 0.05, 0.1, 0.2,0.5 and 1.0mm)GS20566* ZnSe Sealed Heatable Liquid Cellswith 1/1 6” Swagelok fittings forflow purposes.(Specify pathlength from 0.025, 0.05, 0.1, 0.2,0.5 and 1.0mm)*Includes a complete cell with front flow plate,top lead gasket, top window, lead spacer andbottom window all sealed togetherGS20590** NaCl Demountable HeatableLiquid Cells with 1/16” Swagelokfittings for flow purposes(Specify pathlength from 0.006, 0.012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)GS20591** KBr Demountable Heatable LiquidCells with 1/16” Swagelok fittingsfor flow purposes(Specify pathlength from 0.006, 0.012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)GS20592** CaF2 Demountable HeatableLiquid Cells with 1/16” Swagelokfittings for flow purposes(Specify pathlength from 0.006, 0.012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)GS20593** BaF2 Demountable HeatableLiquid Cells with 1/16” Swagelokfittings for flow purposes(Specify pathlength from 0.006, 0.012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)GS20594** ZnSe Demountable HeatableLiquid Cells with 1/16” Swagelokfittings for flow purposes(Specify pathlength from 0.006, 0.012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)Heatable Flow CellGS20569 Heatable Liquid Flow Cell ESKESK** Includes a complete cell with front flow plate,top PTFE gasket, top window, PTFE or Mylarspacer (choice of pathlengths) and bottomwindow that can be separated from each otherP/N GS20560/90www.specac.com19


<strong>Specac</strong> Product Catalogue 2011 | Liquid Sampling Cells Ordering InformationFlow Cells for Heating JacketsP/N GS20710 and GS20730 OnlyOrdering informationFlow CellsGS20570*NaCl Sealed Heatable Liquid Cellwith 1/1 6” Swagelok fittings forflow purposes.(Specify pathlength from 0.025, 0.05, 0.1, 0.2,0.5 and 1.0mm)GS20571* KBr Sealed Heatable Liquid Cellwith 1/1 6” Swagelok fittings forflow purposes.(Specify pathlength from 0.025, 0.05, 0.1, 0.2,0.5 and 1.0mm)GS20572* CaF2 Sealed Heatable Liquid Cellwith 1/1 6” Swagelok fittings forflow purposes.(Specify pathlength from 0.025, 0.05, 0.1, 0.2,0.5 and 1.0mm)GS20573* BaF2 Sealed Heatable Liquid Cellwith 1/1 6” Swagelok fittings forflow purposes.(Specify pathlength from 0.025, 0.05, 0.1, 0.2,0.5 and 1.0mm)GS20576* ZnSe Sealed Heatable Liquid Cellwith 1/1 6” Swagelok fittings forflow purposes.(Specify pathlength from 0.025, 0.05, 0.1, 0.2,0.5 and 1.0mm)*Includes a complete cell with front flow plate,top lead gasket, top window, lead spacer andbottom window all sealed togetherESKGS20580** NaCl Demountable HeatableLiquid Cells with 1/16” Swagelokfittings for flow purposes(Specify pathlength from 0.006, 0.012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)GS20581** KBr Demountable Heatable LiquidCells with 1/16” Swagelok fittingsfor flow purposes(Specify pathlength from 0.006, 0.012, 0.05,0.025, 0.1, 0.2, 0.25, 0.5 and 1.0mm)GS20582** CaF2 Demountable HeatableLiquid Cells with 1/16” Swagelokfittings for flow purposes(Specify pathlength from 0.006, 0.012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)GS20583** BaF2 Demountable HeatableLiquid Cells with 1/16” Swagelokfittings for flow purposes(Specify pathlength from 0.006, 0.012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)GS20586** ZnSe Demountable HeatableLiquid Cells with 1/16” Swagelokfittings for flow purposes(Specify pathlength from 0.006, 0.012, 0.025,0.05, 0.1, 0.2, 0.25, 0.5 and 1.0mm)Heatable Flow CellGS20569 Heatable Liquid Flow Cells ESK** Includes a complete cell with front flow plate,top PTFE gasket, top window, PTFE or Mylarspacer (choice of pathlengths) and bottomwindow that can be separated from each otherP/N GS20570/80www.specac.com20


<strong>Specac</strong> Product Catalogue 2011 | High Pressure Liquid CellHigh Pressure Liquid CellHigh Pressure Liquid Cell<strong>Specac</strong> produce High Pressure Liquid Cells thatare capable of being operated to 5000psi withSapphire or Spectrosil B windows and 2000psiwith ZnSe windows. The pathlength of these cellscan be 0.1mm, 0.2mm, 0.5mm, 1.0mm, 2mm,5mm or 10mm as standard. The windows arepermanently sealed in their window housingassemblies using Viton material O-rings and formost purposes the cells are rated to 180Ctemperature operation. The cells as standard areprovided with their own 3” x 2” mounting plate,which can be removed if the cell is placed into aheating accessory.There are two 1/16” stainless steel flow tubesbrazed to the High Pressure Liquid Cell body tointroduce the fluid to the inner chamber of thecell. The cell can be filled for static operation orfor flow. There is no security valve orover-pressurization device fitted as standard tothe cell, but because the flow tubing isconnected via Swagelok fittings, a safety devicecould be attached in line at this point to theSwagelok connections if required.To be heated, the High Pressure Liquid Cellrequires a heating device such as the ElectricalHeating Jacket and temperature controller(GS20730), or the Variable Temperature Cellholder and temperature controller (GS21525).Either heating accessory is designed to fit intothe sampling compartment of a spectrometer viathe standard 3" x 2" mounting plate, with theHigh Pressure Liquid Cell fitting directly into theElectrical Heating Jacket or the cell holder part ofthe Variable Temperature Cell holder. As anadditional mounting option, the VariableTemperature Cell Holder can also be installedinto a spectrometer via an appropriateBenchmark baseplate.For a volume of fluid needed to fill the HighPressure Liquid Cell, the smallest pathlength cellat 0.1mm requires approximately 15 microliters offluid, whereas the 10mm pathlength cell requires15 milliliters. This is the approximate amount offluid that will be contained in the inner cellchamber at any time, irrespective of it beingoperated for static or flow conditions.As standard the High Pressure Cells arefabricated in EN58 stainless steel but othermaterials are available on request.Ordering InformationGS05910 High Pressure Short PathlengthCell 2000 p.s.i(Specify pathlength from 0.1, 0.2, 0.5 and 1mmand window material from ZnSe, Sapphire andSpec B)GS05915 High Pressure Short PathlengthCell 5000 p.s.i(Specify pathlength from 0.1, 0.2, 0.5 and 1mmand window material from Sapphire or Spec B)GS05920 High Pressure Long PathlengthCell 2000 p.s.i(Specify pathlength from 2, 5 and 10mm andwindow material from ZnSe, Sapphire andSpec B)GS05925 High Pressure Long PathlengthCell 5000 p.s.i(Specify pathlength from 2, 5 and 10mm andwindow material from, Sapphire and Spec B)www.specac.com21


<strong>Specac</strong> Product Catalogue 2011 | High Pressure Liquid CellSpectroelectrochemical Transmission CellKey Features & Benefits• Demountable cell design for easeof cleaning• Modular design to fit a range of sampleholders to facilitate operation from-50°C to 70°C• Gold working and counterelectrodesimprinted on cell window• Perfluoroelastomer seals to ensurecompatibility with a range of solvents• Calcium fluoride windows for UV and IRapplications• 100 and 200 micron optical pathlengthsSpectroelectrochemical Transmission CellSpectroelectrochemistry couples the techniquesof electrochemistry and spectroscopy. It involvesthe application of an electric field to a samplewhilst simultaneously recording spectroscopicabsorption features, and has particularapplication for monitoring redox-coupledreactions to allow in-situ spectroscopic analysisof electro-generated intermediatesand/orproducts.The <strong>Specac</strong> Spectroelectrochemical transmissioncell is an FTIR accessory encompassing athin-layer optically-transparent electrodestructure to facilitate electrochemicalspectroscopicmeasurements.The cell comprises two CaF2 windows separatedby a 100 or 200 micron sample layer, where goldgrid working and counter electrodes, and asilver reference electrode, are photolithographicallyimprinted on the surface of the front windowin contact with the sample. Grid structures with aperiod of 20 lines/mm are available as standard.Perfluoroelastomer seals are used to ensurechemical compatibility with a range of organicsolvents, and the demountable cell design allowsfor ease of cleaning. The cell is air-tight, has asmall sample volume (ca 0.3 – 0.6 ml), and canbe used in an evacuated environment.<strong>Specac</strong>’s Spectroelectrochemical transmissioncell follows a modular design concept to fit with arange of <strong>Specac</strong> sample holders. In particular,the cell is compatible with <strong>Specac</strong>’s Standard CellHolder, Variable Temperature Cell Holder, Water-Heating/Cooling jacket, and Electrical Heatingjacket, to allow Spectroelectrochemicaltransmission measurements from – 50°C to 70°C.Ordering InformationGS20900 SpectroelectrochemicalTransmission Cell(Note: This cell includes both 100 micron and200micron spacer options, and is shippedconfigured at 200 microns )Cell Holders (one required)GS20740 Sample Cell ambient temperatureholder with 3"x 2" backplate mountGS20710 Water Heating JacketGS20730 Electrically Heated Jacket+ temperature controller*GS21525 Variable Temperature Cell holder+ temperature controller**(Notes: *specify country; **Includes NaCl windows(pair) for jacket; must specify country for controllerpower cables and spectrometer for baseplate)Associated and replacement partsGS20907 Pair of externalperfluoroelastomer sealsGS20908 Pair of internalperfluoroelastomer sealsGS20909 Rear CaF2 windowGS20910 Front CaF2 window (with electrode)GS20080 Variable Temperature Cell Holderflow fittings kitGS20200 Variable Temperature Cell Holderspare thermocoupleGS20802(T-type Copper/CopperNickel)Variable Temperature Cell Holderreplacement CaF2windows(pair) for jacketwww.specac.com22


<strong>Specac</strong> Product Catalogue 2011 | Variable Temperature Cell HolderVariable Temperature Cell HolderFor the analysis of liquids or solids between -190ºC and 250ºCP/N GS21525Key FeaturesP/N GS21530• Programmable controlled temperaturesfrom -190ºC to 250ºC (Stability ±0.1ºC)• Dewar cooling system• Heated Jacket windows to preventcondensation• Flow mode option kit for liquids• Solid sample gas exchange capability• Benchmark Baseplate or 3” x 2”mounting optionsVariable Temperature Cell HolderThe Variable Temperature Cell Holder P/NGS21525 is the ideal accessory to use for thetransmission study of liquid or solid samples atvarious temperatures ranging from -190ºC to250ºC.The Variable Temperature Cell Holder consists ofa vacuum jacket with two window ports and a setof windows (NaCl as standard) which contains arefrigerant dewar/cell holder assembly. Liquid orsolid sample holders are inserted into the heatingblock part of the dewar/cell holder and theassembled cell is operated within a vacuumenvironment maintained by the outer jacket.Using a combination of refrigerant and controlfrom the cell block heaters any temperature from-190ºC to 250ºC can be achieved. Choice ofwindow materials for both the jacket and samplecell holders allows for use of this accessory in theUV, visible and IR regions.The Variable Temperature Cell Holder is suppliedwith a high stability controller with a factory fittedoption for control via RS232, RS485 or USBconnectivity if ordered.For certain applications such as Raman,Fluorescence and UV spectral measurements<strong>Specac</strong> offer a four window port version on thevacuum jacket as the Variable TemperatureCuvette Holder (GS21530), special quartz glasscuvettes are used to contain a liquidsample. The four window ports allow forcollection of the scattered radiation from acuvette cell at a 90 deg incident angle as well asat a 180 deg (standard tranmission) as measuredfrom the Variable Temperature Cell Holder(GS21525)Applications• Analysis under extreme temperatureconditions• Absorption band study at lowtemperatures• Polymerization studies• Phase transition studies• Reaction kinetics• Polymorphism• Catalysis• Oxidation studieswww.specac.com23


<strong>Specac</strong> Product Catalogue 2011 | Variable Temperature Cell Holder Ordering InformationVariable Temperature Cell HoldersFor the analysis of liquids or solids between -190ºC and 250ºCOrdering InformationVariable Temperature Cell holdersGS21525 The Variable Temperature CellholderIncludes: Refrigerant dewar/cellholderVacuum jacket with NaCl windowsFixed thermocouple(copper-constantan)Low voltage supply cablesHigh Stability TemperatureController with factory fittedoption for control via RS232,RS485 or USB connectivityif orderedThis accessory also requires aliquid or solids sample holder(See pages 16 - 22)Please specify spectrometer make and modelfor Baseplate version. For controller specify 220Vor 110V and country of usageGS21530 4 Port Variable TemperatureCuvette holderIncludes: Refrigerant dewar/cellholderVacuum jacket with NaCl windowsFixed thermocouple(copper-constantan)Low voltage supply cablesHigh Stability TemperatureController with factory fittedoption for control via RS232,RS485 or USB connectivityif orderedPlease specify spectrometer make and modelfor Baseplate version. For controller specify 220Vor 110V and country of usageReplacement Windows for VariableTemperature Cell (copper-constantan)GS20800 Pair of NaCl windowsGS20801 Pair of KBr windowsGS20802 Pair of CaF2 windowsGS20803 Pair of BaF2 windowsGS20896 Pair of ZnSe windowsGS20898 Pair of Spec B (UV) windowsSpares for Variable Temperature Cell holderGS20200 Monitoring Thermocouple(copper-constantan)GS20201 System Control Thermocouple(copper-constantan)GS20810 Replacement set of O-ringsGS21526 VT Cell Holder ESKOptionsGS28000GS28001GS28002RS232 Connection kitUSB Connection kitRS485 Connection kitELECTRIC VACUUM COMMS ESKwww.specac.com24


<strong>Specac</strong> Product Catalogue 2011 | Electrical Heating JacketElectrical Heating JacketFor liquid and solid sampling in transmission from ambient to 250ºCKey Features• Programmable controlled temperaturesup to 250ºC• Static or flow sampling capabilities• Fully CE Safety compliant• Protective water cooling system• Standard 3” x 2” slide mountOrdering InformationElectrical Heating JacketThe Electrical Heating Jacket P/N GS20730,is used for the study of samples by transmissionspectroscopy over a temperature range fromambient to 250°C. It consists of a centralheatable chamber with a front cover plate.Liquid and solid sample cell holder types areplaced within the central chamber and held inplace by the cover plate. The whole assembly(Jacket plus sample cell holder) is installed into aspectrometer sample compartment via the3” x 2” slide mounting plate.Heating to the Jacket is provided by its owndedicated low voltage (30 Volts) temperaturecontrolling system, that is provided with theHeating Jacket as standard. A water coolingback plate incorporated into the 3” x 2” slidemounting plate of the Jacket acts to keep anyheat at the central chamber from spreading tothe mount area of the sample compartmentduring operation.For the study of liquid samples, the liquid cells ofthe GS20500/20510 Series type (static andflow versions) are placed into the ElectricalHeating Jackets central chamber. If solid samplesare to be analysed, then the specific solids holderP/N GS20600 is used within the ElectricalHeating Jacket.The Electrical Heating Jacket is supplied with ahigh stability power controller with a factory fittedoption for control via RS232, RS485 or USBconnectivity if ordered.GS20730Electrical Heating JacketIncludes: Low voltage heatedjacket with water cooling systemELECTRICCOMMSWATER 5 ltrNiCr/NiAl thermocoupleHigh Stability TemperatureController factory fitted option forcontrol via RS232, RS485 or USBconnectivity if ordered.This accessory also requires aliquid or solids sample holder(See pages 16 - 22)Please specify 220V or 110V & country of usageOptionsGS28000RS232 Connection kitGS28001USB Connection kitGS28002RS485 Connection kitwww.specac.com25


<strong>Specac</strong> Product Catalogue 2011 | Water Heating JacketWater Heating JacketFor liquid and solid sampling in transmission to 90 ºCOrdering InformationGS20710The Water Heating JacketIncludes, Water Heating Jacket ona 3” x 2” mountRequires, but does not include:1. A liquid or solid sample holder2. Thermocirculating systemWATER 5 ltrWater Heating JacketThe Water Heating Jacket is similar to theElectrical Heating Jacket, but it uses circulatingwater to heat the sample cell. A jacket aroundthe circular aperture is filled with a solution, forexample water, heated by a thermocirculatingsystem.Temperature control of the sample holder isreliant upon this thermocirculating system.The sample cell holders used with ElectricalHeating Jacket can also be used in thisaccessory.20500/20510 Series Liquid Cells Solids Holders & High Pressure Liquid Cells and compatible Mount HoldersKey: • = compatibleCell Holder/MountCell Series TypeVT CellGS21525EHJGS20730WHJGS20710AmbientGS20740Liquid CellsGS20500 Sealed/Static GS20510 Demountable/Static GS20560 VT Cell Sealed/Flow• GS20570 EHJ Sealed/Flow GS20580 EHJ Demountable/Flow GS20590 VT Cell Demountable/Flow GS20900 SEC Cell• • • •Solids HoldersGS20600GS20610•• • •High Pressure Liquid CellsGS05910 GS05915 GS05920 GS05925• • •26www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Oil in Water Analysis KitOil in Water Analysis KitFor the analysis of total recoverable oil and grease or petroleum hydrocarbons in waterKey Features• Matched transmission cell pairs• Large aperture to avoid scattering ofIR beam• Stoppered• Three different pathlengths:(10mm, 50mm, 100mm)• Transmission range approximately40,000cm -1 to 2,700cm -1• Slide mounted holderOrdering InformationGS08900GS08901GS08902GS08903GS08904Oil in Water Analysis KitIncludes:Matched pair of 10mm pathlengthrectangular infrared quartz cellsMatched pair of 50mm pathlengthcylindrical infrared quartz cellsMatched pair of 100mm pathlength cylindrical infraredquartz cellsSlide mounted holderOil in Water Analysis KitThe Oil In Water Analysis Kit enables the analysisof total recoverable oil and grease or petroleumhydrocarbons in water using a new method ofanalysis D7066-04 approved by the ASTM(American Society for Testing and Materials).The existing standard EPA methods 413.2 and418.1 have been replaced as they called for useof Freon as the extraction solvent for therecovery of oil and grease within a water sample.Freon is now banned from usage as it is anOzone depleting chemical and harmful to theenvironment. The D7066-04 method is verysimilar to the EPA methods but the Freon solventis replaced by use of the dimer/trimer ofchlorotrifluoroethylene (C2ClF3). This solvent isknown commercially as S-316 available as an IRspectroscopy grade solvent.The ASTM D7066-04 method can be purchasedfrom the American National Standards Institute(ANSI). Go to their website pagewww.webstore.ansi.org and search for themethod D7066-04. The method describes theprocedure for testing and lists the relevantequipment and chemicals needed. (<strong>Specac</strong>does not provide this equipment or chemicals.)The Oil in Water Analysis Kit from <strong>Specac</strong>contains matched pairs of infrared grade quartzcells supplied in three different pathlengths of10mm, 50mm and 100mm. They are all stopperedto ensure retention of volatile materials in thesamples. The cells have large filling ports toensure quick and efficient sample introductionand removal. Matching of the cells ensuresprecise, repeat measurements.The cells are placed into the spectrometer via theparticular 3” x 2” mounting holder supplied.www.specac.com27


<strong>Specac</strong> Product Catalogue 2011 | DC-2 Diamond Compression CellDC-2 Diamond Compression CellA Universal Diamond Compression Cell specially designed for FTIR microscopes and the<strong>Specac</strong> Microfocus Beam CondenserKey Features• Type IIIa flat diamond windows• Large clear aperture 1.5mm• Hastelloy body construction(3” x 2” x 9/16”, 76.2 x 50.8 x 14.3mm)• Universal use with FTIR microscopes and• Microfocus Beam Condenser• High working pressure, high throughputApplications• Compression to optimum transmissionthickness of polymers, rubbers andminerals• Microanalysis of brittle, elastic semi-rigidfibres, particles and fragmentsSpares and ConsumablesGS02508 Sample forcepsGS02509 Stainless steel sample needleGS02510 Sample preparation knife withblades (10) and blade removerDC-2 Diamond Compression CellThe DC-2 diamond compression cell enablessamples to be compressed to an ideal thicknessfor transmission experiments. It uses two typeIIIa diamond windows, each mounted into aHastelloy plate. The clear aperture of 1.5 mmdiameter provides excellent signal throughputwhen positioned at the beam focus of an FTIRspectrophotometer using an MCT detector. Foroptimum performance with a DTGS detector, theMicrofocus Beam Condenser P/N GS02560(with ZnSe lenses) or P/N GS02561 (with KRS-5lenses) is recommended to be used with the DC-2 in order to obtain high quality spectra.The DC-2, because of its small size and shapecan also be used with Infrared Microscopes,where the large aperture allows for more thanone sample to be loaded and compressed at onetime. Each individual sample could then beselectively moved into the light beam from the IRmicroscope, saving on the time needed to mountand prepare each sample between analyses.Ordering InformationGS02550 DC-2 Diamond Compression CellOptionsGS02551* Diasqueeze Plus Kit withZnSe lensesGS02552* Diasqueeze Plus Kit withKRS-5 lensesIncludes: DC-2 DiamondCompression CellMicrofocus Beam CondenserForcepsStainless steel sample needleSample preparation knifeBlades (10)Blade remover (2)GS02560* Microfocus Beam Condenser withZnSe LensesGS02561* Microfocus Beam Condenser withKRS-5 LensesGS02570 KRS-5 lens kit for use withMicrofocus Beam CondenserGS02571 ZnSe lens kit for use withMicrofocus Beam Condenser*Please specify spectrometer make and model28www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Microfocus Beam CondenserMicrofocus Beam CondenserA rugged, high performance 4x Beam Condenser specially designed for use with theDC-2 Diamond Compression CellOrdering InformationMicrofocus Beam CondenserGS02560 Microfocus Beam CondenserZnSePlease specify spectrometer make and modelGS02561 Microfocus Beam CondenserKRS-5Please specify spectrometer make and modelMicrofocus Beam CondenserThe Microfocus Beam Condenser is a highperformance 4x beam condenser speciallydesigned for use with the DC-2 DiamondCompression Cell (P/N GS02550). The simpletwo lens linear optical system ensures easyalignment and high throughput over a wideworking wavelength range. The Microfocus beamcondenser can be supplied with either ZnSelenses (P/N GS02560) or with KRS-5 lenses(P/N GS02561). (KRS-5 allows an extendedrange in the mid-infrared to circa 350 cm-1).Lens upgrade kits (P/N GS02570 KRS-5 lenskit, P/N GS02571 ZnSe lens kit) are availableshould you wish to change from one version tothe other.The Microfocus Beam Condenser is opticallymatched for the DC-2 Diamond CompressionCell (P/N GS02550), which locates accuratelyand reproducibly in the beam condenser usingspring ball catches. The whole accessorycombination (DC-2 in the Microfocus beamcondenser) is mounted into a spectrometersample compartment via a standard <strong>Specac</strong>Benchmark baseplate. This allows for optimumstability in all FTIR spectrometers.GS02570GS02571Microfocus Beam CondenserKRS-5 Lens KitMicrofocus Beam CondenserZnSe Lens KitGS02508GS02509GS02510Sample forcepsStainless steel sample needleSample preparation knife withblades (10) and blade removerwww.specac.com29


<strong>Specac</strong> Product Catalogue 2011 | GS02520Micro Compression CellThe <strong>Specac</strong> Micro Compression Cell is intended for soft solid or semi liquid sample analysis byFTIR transmission or infrared microscopyOrdering InformationMicro Compression CellGS02520 Micro Compression Cell(With choice ofNaCl or KBr windows)Micro Compression Cell WindowsGS09070 NaCl windows circular 13mm dia(pair)GS09071 KBr windows circular 13mm dia(pair)GS09072 CaF2 windows circular 13mm dia(pair)GS09073 BaF2 windows circular 13mm dia(pair)GS09076 ZnSe windows circular 13mm dia(pair)Key Features• Uniform pressure applied across sample• Non rotating windows• 7.0 mm clear aperture• Choice of window materials• Standard 3” by 2” slide mountMicro Compression CellThe <strong>Specac</strong> Micro Compression Cell is intendedfor soft solid or semi liquid sample analysis byFTIR transmission or infrared microscopy. Thecell allows for samples to be compressed andflattened between two non-rotating transmissionwindows for analysis. It is supplied with a choiceof NaCl or KBr windows as standard, but CaF2,BaF2, and ZnSe windows are also available. Thecell is mounted to a standard spectrophotometer3” by 2” slide mount for ease of use in a broadrange of optical spectrometers.With a clear aperture of 7.0 mm diameter, the<strong>Specac</strong> Micro Compression Cell allows for agood signal when placed at the sampling focusof a standard FTIR spectrometer. Alternatively,the Micro Compression Cell can also be usedwith an infrared microscope, where the largeaperture allows for more than one sample to beloaded at one time.30www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Storm 10cm Gas CellStorm 10cm Gas CellDesigned for Routine Gas AnalysisP/N GS05800 P/N GS05000 P/N GS05030Key Features• Demountable for ease of cleaning andwindow replacement• Choice of cell material: stainless steelor Pyrex• Choice of window materials• Window diameter: 47mm• Clear aperture: 39mm• Two ports for static or flow experiments• Slide mounted cell holderApplications• Qualitative gas analysis• Residual solvent vapour analysis• Liquid head-space analysisStorm 10cm Gas CellThese gas cells are ideal for analyzing gases andvapors at room temperature and low pressures.Gases and gaseous mixtures can be examined instatic or flow modes.The cells consist of threaded cylindrical vesselswith end caps, window seals and removablewindows. The cell bodies are available in Pyrex and stainless steel.Pyrex and PTFE taps and valves are used forthe Pyrex cells while stainless steel and Viton ®sealed valves are used for the stainless steelcells to introduce samples into these cells.GASOrdering InformationStorm 10cm Gas CellsGS05000GS05800Cell MountsGS05030Series Storm 10cm Pyrex Gas Cell (specify windows)Series Storm 10cm StainlessSteel Gas Cell (specify windows)Cell Mount for Pyrex andStainless Steel Storm Gas CellReplacement Windowsfor Pyrex and Stainless SteelStorm Gas CellsGS05020 Pair of NaCl windowsGS05021 Pair of KBr windowsGS05022 Pair of CaF2 windowsGS05023 Pair of BaF2 windowsGS05096 Pair of ZnSe windowsSpares and ConsumablesGS05040 Complete seal kit for Pyrex Gas CellGS05803 Vacuum valve for Stainless SteelGas CellGS05804 Complete seal kit for StainlessSteel Gas Cellwww.specac.com31


<strong>Specac</strong> Product Catalogue 2011 | 10cm Heated Gas CellStorm 10cm Heated Gas CellAnalyze gaseous samples and vapors from room temperature to 250°CKey Features• Stainless steel construction• Stainless steel vacuum stopcock• Chemically resistant window seals• Choice of window materials• 10cm pathlength/38mm clear aperture• Low voltage (30v) heater system foroperator safety• Programmable controlled temperaturevia optional RS232,RS485 orUSB connection• Slide mounting supplied• Flow mode (optional)• Window size 47mm diameterApplications• Gases and vapours at elevatedtemperatures• Vapours generated by solids and liquidsat elevated temperatures• Decomposition studiesStorm 10cm Heated Gas CellThe Storm 10cm Heated Gas Cell analyzesgaseous samples and vapours from ambienttemperature to 250°C.The cell is an evacuable stainless steel chamberwith an injection septum sample introduction portand is heated by a low voltage (30v) heatersurrounding the body.The exact gas temperature can be measuredwith an additional monitoring thermocouple(supplied) which passes through a vacuumtight seal into the gas cavity. The cell is suppliedwith a High Stability Temperature Controller witha factory fitted option for control via RS232,RS485 or USB connectivity if ordered.The cell can be converted to a flow mode via1/16” stainless steel flow tube in exchange at theinjection septum and additional monitoringthermocouple connection ports.ELECTRIC VACUUM GAS COMMSOrdering InformationStorm 10cm Heated Gas CellGS05670 Series Storm 10cm HeatedGas Cell (specify windows)Includes: High StabilityTemperature ControllerPlease specify 220V or 110V & country of usageOptionsGS28000 RS232 Connection kitGS28001 USB Connection kitGS28002 RS485 Connection kitReplacement WindowsGS05020 Pair of NaCl windowsGS05121 Pair of KBr windowsGS05022 Pair of CaF2 windowsGS05023 Pair of BaF2 windowsGS05096 Pair of ZnSe windowsPlease note part No GS05121 are thickerKBr windows required for this cell.Spares and ConsumablesGS05662 Stainless steel flow tubes (10)GS05665 Injection Septa (10)GS05667 Complete seal kitwww.specac.com32


<strong>Specac</strong> Product Catalogue 2011 | Cyclone Gas CellsCyclone Gas CellsHeatable Long Pathlength Gas CellsStandard Features• Fixed pathlength• Borosilicate glass body• Ambient temperature operation• Vacuum to 15 p.s.i. operation• Gold mirrors (protected)• Viton ® ‘O’ ring seals• KBr windows• Adhesive-free construction• Nickel-plated aluminium components• Vacuum / gas inlet & outlet taps• Purgeable transfer optics box• Benchmark series baseplate mounting• CE compliantOptional Features• Variable pathlength mirror carriage• Additional fixed pathlength mirrorcarriages (all models)• ZnSe or CaF2 windows• Nickel-plated aluminium body forhigh pressures operation (up to 125 p.s.i.)• Heating jacket / controller for hightemperature operation (up to 200°C)• Pressure gauge kit• Desiccant storage caps• Purge bellows• Laser alignment accessoryCyclone Gas CellsBased on the White cell principle of multiple lightpasses between an arrangement of reflectingmirrors, Cyclone gas cells are available in threesizes:• Cyclone C2 - Fixed or variablepathlengths ranging from 0.5m to 2.5m• Cyclone C5 - Fixed or variablepathlengths ranging from 1m to 8m• Cyclone C10 - Fixed or variablepathlengths ranging from 2.1m to 10.6mCyclone series gas cells are suitable foroperation in all modern FT-IR spectrometersusing the <strong>Specac</strong> Benchmark baseplateprovided as standard.Cells are available as standard with a borosilicateglass body for operation at ambient temperaturesand pressures ranging from vacuum to 15 p.s.i.Protected gold mirrors, internal and externalcomponents made from nickel-plated aluminiumand stainless steel, and Viton ® ‘O’ rings arecombined to ensure the highest chemicalscompatibility and protection from leaks.Vacuum/gas inlet and outlet taps, KBr windowsand a purgeable transfer optics box furtherenhance this already highly featured range.Unsurpassed UpgradeabilityCyclone’s impressive list of optional featuresmeans that any analytical challenge can be met.Variable pathlength mirror carriages, and a rangeof fixed pathlength mirror carriages can be usedwithin a single gas cell body to greatly enhanceanalytical flexibility and reduce costs.Nickel-plated aluminium bodies can be specifiedfor high pressure operation up to 125 p.s.i., andheating jackets/high stability temperaturecontrollers allow operation at temperatures upto 200°C.Purge bellows allow the transfer optics to beused under inert gas atmospheres (e.g. nitrogen)in applications where the elimination ofatmospheric H 2 O and CO 2 absorbancesis required.Design ExcellenceTo ensure perfect operation and freedom fromunwanted impurities, a number of uniquefeatures have been incorporated into the designand manufacture of the Cyclone series. Cont’d-www.specac.com33


<strong>Specac</strong> Product Catalogue 2011 | Cyclone Gas CellsCyclone Gas CellsHeatable Long Pathlength Gas CellsThe cells are completely free from adhesives andall of the Viton ® ‘O’ ring seals are carefullypre-baked to eliminate any contamination fromsolvents or out-gassing.Internal screws have small bleed holes drilled intothem to prevent any trapped pockets of gascausing sample cross contamination.CE ComplianceAll Cyclone series heated gas cell systems areCE compliant ensuring that they can be operatedsafely at all times under the recommendedconditions.Cyclone C2Specifications• Pathlength: 0.5m - 2.5m (fixed or variable)• Pathlength steps: 0.5m• Volume: 0.19 litres• Cell body material: Borosilicate glass(optional metal body)• Pressure range: Vacuum to 15 p.s.i.(optional 125 p.s.i.)• Temperature range: Ambient(optional heated systems available)• Mirrors: Gold (protected)• Windows: KBr (optional ZnSe or CaF2)• Inlet/outlet fittings: Stainless steel taps‘O’ rings: Viton ®• Internal components: Nickel-platedaluminium & stainless steel• Transfer optics: Aluminium mirrors inpurgeable optics box• Cell mount: Benchmark series baseplate• Dimensions (mm): H384 W153 D120Cyclone C5Specifications• Pathlength: 1m - 8m (fixed or variable)• Pathlength steps: 1m• Volume: 1.33 litres• Cell body material: Borosilicate glass(optional metal body)• Pressure range: Vacuum to 15 p.s.i.(optional 125 p.s.i.)• Temperature range: Ambient (optionalheated systems available)• Mirrors: Gold (protected)• Windows: KBr (optional ZnSe or CaF2)Inlet/outlet fittings: Stainless steel taps‘O’ rings: Viton ®Internal components: Nickel-platedaluminium & stainless steel• Transfer optics: Aluminium mirrors inpurgeable optics box• Cell mount: Benchmark series baseplate• Dimensions (mm): H536 W153 D130www.specac.com34


<strong>Specac</strong> Product Catalogue 2011 | Cyclone Gas CellsCyclone Gas CellsHeatable Long Pathlength Gas CellsCyclone C10Specifications• Pathlength: 2.1m-10.6m (fixed or variable)• Pathlength steps: 1.06m• Volume: 2.61 litres• Cell body material: Borosilicate glass(optional metal body)• Pressure range: Vacuum to 15 p.s.i.(optional 125 p.s.i.)• Temperature range: Ambient (optionalheated systems available)• Mirrors: Gold (protected)• Windows: KBr (optional ZnSe or CaF2)Inlet/outlet fittings: Stainless steel taps‘O’ rings: Viton ®Internal components: Nickel-platedaluminium & stainless steel• Transfer optics: Aluminium mirrors inpurgeable optics box• Cell mount: Benchmark series baseplate• Dimensions (mm): H540 W153 D146Mirror CarriageWindowsVacuum/GasInlet & OutletTapsOptics BoxObjective MirrorsGlass or MetalBodyPurge PortsCell A B C D EC2 384 314 73 47 153C5 536 466 114 87 153C10 540 470 143 113 153All dimensions in mmCellBasePathlengthC2 12.5cmC525cmC10 26.4cmPathlengthRange0.5m to 2.5m(in 0.5m steps)1m to 8m(in 1m steps)2.1m to 10.6m(in 1.06m steps)Volume0.19 litres1.33 litres2.60 litresCyclone Key Dimensionswww.specac.com35


<strong>Specac</strong> Product Catalogue 2011 | Cyclone Gas CellsCyclone Gas Cells - Optional FeaturesOptional FeaturesOptional FeaturesCyclone series heatable long pathlength gascells have been designed with the serious analystin mind. These high performance, superior qualitycells are backed by a comprehensive range ofoptional upgrades ensuring that they meet everyanalytical challenge.Purge BellowsA pair of purge bellows is available for theCyclone series gas cells. These fit between theoptics box of the cell and the spectrometer toallow the purging of transfer optics with inertgases such as nitrogen. This feature allowsabsorbances due to atmospheric H 2 O and CO 2 tobe eliminated from spectral measurements.These bellows are designed to fit all <strong>Specac</strong>Benchmark sampling accessories.GS10707 Purge Bellows (pair)Desiccant Storage CapsThese caps are designed to fit over the opticalinlet and outlet ports of the Cyclone series gascells to seal the transfer optics when the cells arenot in use.One of the caps contains a desiccant materialwhich maintains a dry atmosphere within thetransfer optics box and extends the life of KBrwindows.GS24150 Desiccant Storage CapsPressure Gauge KitA pressure gauge kit is available to fit theCyclone series gas cells. Gauges can bespecified for low pressure operation (vacuum to15 p.s.i.) and high pressure operation (vacuum to125 p.s.i). An integral pressure relief valveensures that cells are automaticallydepressurised in the event of accidental overpressurisation.<strong>Specac</strong> recommend the use of a pressure gaugewhen operating gas cells at elevated pressures.GS24160 Pressure Gauge Kit(Specify High or Low pressure)36www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Cyclone Gas CellsCyclone Gas Cells - Optional FeaturesOptional FeaturesHeating Jacket / High StabilityTemperature ControllerAll of the Cyclone series gas cells (glass andmetal bodied versions) can be upgraded toheatable gas cells by the addition of theappropriate Heating Jacket and High StabilityTemperature Controller. The heating jacket simplyslides over the gas cell and it can be operatedfrom ambient temperatures up to 200°C.Low voltage (32V) heaters are used to ensuresafe operation at all times and the temperaturecontroller has a factory fitted option of RS232,RS485 or USB connectivity if ordered.Temperature stability is +/-1°C and a key featureof the design is the uniformity of the heatingacross the whole cell, which prevents localised˝cold spots˝ within the cell.All of the Cyclone series Heating Jacket / HighStability Temperature Controller systems areCE compliant ensuring that they can be operatedsafely at all times under the recommendedconditions.GS24302 Heating Jacket / Controller forCyclone C2GS24305 Heating Jacket / Controller forCyclone C5GS24310 Heating Jacket / Controller forCyclone C10(Specify voltage and country of usage)Benchmark Series LaserAlignment AccessoryThis accessory allows the visual verification ofthe optical pathlength through Cyclone seriesgas cells.This is especially useful when differentpathlengths are regularly used with variablepathlength cells.The accessory is based on a low power (0.8mW)visible continuous wave LED precisely located inposition in a Benchmark accessory alignmenthousing. The gas cell simply slots into thealignment accessory. The 635nm Class II lasercan be powered from a battery unit or by thededicated mains transformer supplied.Benchmark Laser Alignment Accessory is Ccompliant ensuring that it can be operated safelyat all times under the recommended conditions.GS24500 Benchmark Series LaserAlignment Accessory(Specify voltage and country of usage)37www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Cyclone Gas CellsCyclone Gas Cells - Ordering InformationHeatable Long Pathlength Gas CellsOrdering InformationGS24102 Cyclone C2Long Pathlength Gas Cell0.5m to 2.5m (supplied withKBr windows as standard)specify fixed or variable pathlength, Windows(KBr, ZnSe or CaF 2 ), Body material (nickel-platedaluminium or glass)GS24105 Cyclone C5Long Pathlength Gas Cell1m to 8m (supplied withKBr windows as standard)specify Fixed or variable pathlengthPathlength (for fixed pathlength version)Windows (KBr, ZnSe or CaF 2 )Body material (nickel-plated aluminium or glass)GS24110 Cyclone C10Long Pathlength Gas Cell2.1m to 10.6m (supplied withKBr windows as standard)specify Fixed or variable pathlengthPathlength (for fixed pathlength version)Windows (KBr, ZnSe or CaF 2 )Body material (nickel-plated aluminium or glass)Fixed pathlengths availableCyclone C2 0.5, 1.0, 1.5, 2.0 & 2.5mCyclone C5 1, 2, 3, 4, 5, 6, 7 & 8mCyclone C10 2.1, 3.2, 4.2, 5.3, 6.3, 7.4,8.5, 9.5 & 10.6mOptionsGS10707 Purge Bellows (pair)GS24150 Desiccant Storage CapsGS24152 Mirror Carriage Assembly forCyclone series gas cells(specify model, variable or fixed pathlength, andpathlength where a fixed pathlength mirrorcarriage is required)GS24160 Pressure Gauge KitTo fit Cyclone and Tornado series gas cells(specify High or Low Pressure)GS24302 Heating Jacket / Controller forCyclone C2(Specify voltage and country of usage)GS24305 Heating Jacket / Controller forCyclone C5(Specify voltage and country of usage)GS24310 Heating Jacket / Controller forCyclone C10(Specify voltage and country of usage)GS28000 RS232 Connection kitGS28001 USB Connection kitGS28002 RS485 Connection kitGS24500 Laser Alignment AccessoryGS24153 Replacement KBr windows forCyclone and Tornado seriesgas cells(specify model)GS24154 Replacement ZnSe windows forCyclone and Tornado seriesgas cells(specify model)GS24155 Replacement CaF2 windows forCyclone and Tornado seriesgas cells(specify model)GS24103 Cyclone Gas Cell C2 ESKGS24106 Cyclone Gas Cell C5, C10, C20 ESKGas CellsVACUUMGASESKHeating Jackets & Laser Alignment AccessoryELECTRICCOMMSwww.specac.com38


<strong>Specac</strong> Product Catalogue 2011 | Tornado Gas CellsTornado Gas CellsA low-cost range of gas cells for routine analysis at ambient conditionsStandard Features• Wide pathlength range (1m - 20m)• Vacuum to 15 p.s.i. operation• Ambient temperature operation• Borosilicate glass body• Anodised components• Gold mirrors (protected)• Viton ® ‘O’ ring seals• KBr, ZnSe or CaF2 windows• Purgeable transfer optics box• Benchmark series baseplate mountingOptional Features• Additional mirror carriage assemblies• Vacuum/gas inlet & outlet taps• Pressure gauge• Desiccant storage caps• Purge bellowsTornado Gas CellsThe Tornado series is the ideal choice foranalysts requiring a fixed, long pathlength gas cellfor routine applications.Based on the White cell principle of multiple lightpasses between an arrangement of reflectingmirrors, Tornado series is available in threesizes:• Tornado T5Pathlengths ranging from 1m to 8min 1m steps• Tornado T10Pathlengths ranging from 2.1m to 10.6min 1.06m steps• Tornado T20Pathlengths ranging from 2m to 20min 2m stepsTornado series gas cells are suitable foroperation in all modern FT-IR spectrometersusing the <strong>Specac</strong> Benchmark baseplateprovided as standard.Borosilicate glass body material and anodisedaluminium/stainless steel internal and externalcomponents provide superior corrosion resistanceagainst a wide range of gases and vapors.Viton ® ‘O’ rings ensure leak-free performanceunder vacuum and ambient pressures. State-ofthe-artoptical design combined with gold mirrorsensures the highest possible light throughputgiving superior analytical sensitivity.The supreme, in-built flexibility of the Tornado series allows additional mirror carriages to beused in the same body shell, maximisinganalytical capability and minimising operationalcosts.A choice of KBr, ZnSe or CaF2 window materialsallows users to make the optimum windowchoice for their applications, and the transferoptics box is equipped with purge ports to allowoperation under inert atmospheres. A range ofoptional features further enhances the flexibility ofthe Tornado range.www.specac.com39


<strong>Specac</strong> Product Catalogue 2011 | Tornado Gas CellsTornado Gas CellsA low-cost range of gas cells for routine analysis at ambient conditionsTornado T5Specifications• Pathlength (fixed): 1m - 8m• Pathlength steps: 1m• Volume: 1.33 litres• Cell body material: Borosilicate glass• Pressure range: Vacuum to 15 p.s.i.• Temperature range: Ambient• Mirrors: Gold (protected)• Windows: KBr, ZnSe or CaF2• Inlet/outlet tubing: 1/4˝• ‘O’ rings: Viton ®• Internal components: Anodised aluminium& stainless steel• Transfer optics: Aluminium mirrors inpurgeable optics box• Cell mount: Benchmark series baseplate• Dimensions (mm): H455 W153 D130Tornado T10Specifications• Pathlength (fixed): 2.1m - 10.6m• Pathlength steps: 1.06m• Volume: 2.6 litres• Cell body material: Borosilicate glass• Pressure range: Vacuum to 15 p.s.i.• Temperature range: Ambient• Mirrors: Gold (protected)• Windows: KBr, ZnSe or CaF2• Inlet/outlet tubing: 1/4˝• ‘O’ rings: Viton ®• Internal components: Anodised aluminium& stainless steel• Transfer optics: Aluminium mirrors inpurgeable optics box• Cell mount: Benchmark series baseplate• Dimensions (mm): H470 W153 D146www.specac.com40


<strong>Specac</strong> Product Catalogue 2011 | Tornado Gas CellsTornado Gas CellsA low-cost range of gas cells for routine analysis at ambient conditionsTornado T20Specifications• Pathlength (fixed): 2m - 20m• Pathlength steps: 2m• Volume: 4.7 litres• Cell body material: Borosilicate glass• Pressure range: Vacuum to 15 p.s.i.• Temperature range: Ambient• Mirrors: Gold (protected)• Windows: KBr, ZnSe or CaF2• Inlet/outlet tubing: 1/4˝• ‘O’ rings: Viton ®• Internal components: Anodised aluminium& stainless steel• Transfer optics: Aluminium mirrors inpurgeable optics box• Cell mount: Benchmark series baseplate• Dimensions (mm): H675 W153 D146Mirror CarriageWindowsVacuum/GasInlet & OutletTapsOptics BoxObjective MirrorsGlass or MetalBodyPurge PortsCell A B C D ET5 455 385 114 86 153T10 470 400 143 113 153CellT5BasePathlength25cmT10 26.4cmPathlengthRange1m to 8m(in 1m steps)2.1m to 10.6m(in 1.06m steps)Volume1.33 litres2.6 litresT20 675 606 143 113 153T200.5cm2m to 20m(in 2m steps)4.7 litresAll dimensions in mmTornado Key Dimensionswww.specac.com41


<strong>Specac</strong> Product Catalogue 2011 | Tornado Gas CellsTornado Gas Cells - Optional FeaturesOptional FeaturesOptional FeaturesTornado series long pathlength gas cells havebeen designed with the serious analyst in mind.These high performance, superior quality cells arebacked by a range of optional upgrades to furtherenhance their performance.Purge BellowsA pair of purge bellows is available for theTornado series gas cells. These fit between theoptics box of the cell and the spectrometer toallow the purging of transfer optics with inertgases such as nitrogen. This feature allowsabsorbances due to atmospheric H 2O and CO 2to be eliminated from spectral measurements.GS10707 Purge Bellows (pair)Desiccant Storage CapsThese caps are designed to fit over the opticalinlet and outlet ports of the Tornado series gascells to seal the transfer optics when the cells arenot in use. One of the caps contains a desiccantmaterial, which maintains a dry atmospherewithin the transfer optics box and extends the lifeof KBr windows.GS24150 Desiccant Storage CapsPressure Gauge KitA pressure gauge kit is available to fit theTornado series gas cells. Gauges are designedfor low pressure operation (vacuum to 15 p.s.i.)and an integral pressure relief valve ensures thatcells are automatically depressurised in the eventof accidental over pressurisation.GS24160 Pressure Gauge Kit(Specify for Tornado series).42www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Tornado Gas CellsTornado Gas Cells - Optional Features cont’dOptional FeaturesMirror Carriage AssemblyAdditional mirror carriages can be specified foruse within a single Tornado body. This featuregreatly enhances the analytical flexibility of theseries, and significantly reduces operating costs.GS24252 Mirror Carriage Assembly(Specify model and pathlength)Ordering InformationGS24205 Tornado T51m - 8m Fixed Long PathlengthGas Cell(specify: pathlength & windows)GS24205 Tornado T102.1m - 10.6m Fixed LongPathlength Gas Cell(specify: pathlength & windows)GS24205 Tornado T51m - 8m Fixed Long PathlengthGas Cell(specify: pathlength & windows)Fixed pathlengths availableTornado T5 1, 2, 3, 4, 5, 6, 7, 8mTornado T10 2.1, 3.2, 4.2, 5.3, 6.3, 7.4, 8.5,9.5 & 10.6mTornado T20 2, 4, 6, 8, 10, 12, 14, 16, 18& 20mOptionsGS10707 Purge Bellows (pair)GS24150 Desiccant Storage CapsGS24252 Mirror Carriage Assembly forTornado series gas cells(specify model & pathlength)GS24160 Pressure Gauge Kit to fitTornado series gas cells(specify model & high or low pressure)GS24161 Vacuum / Gas Inlet & Outlet Tapswith push-on connectors forTornado series gas cellsGS24206 Tornado Gas Cell T5 ESKGS24207 Tornado Gas Cell CT10, T20 ESKReplacement WindowsGS24153 Replacement KBr windows forTornado and Cyclone seriesgas cells(specify model)GS24154 Replacement ZnSe windows forTornado and Cyclone seriesgas cells(specify model)GS24155 Replacement CaF2 windows forTornado and Cyclone seriesgas cells(specify model)VACUUM GAS ESKwww.specac.com43


<strong>Specac</strong> Product Catalogue 2011 | High Temperature/High Pressure CellHigh Temperature/High Pressure Cell For ExtremeCondition AnalysisIn-situ analysis under extreme conditionsHigh Temperature/High Pressure CellHigh technology products and modern industrialprocesses require in-situ analysis under extremeconditions of temperature and pressure.The ability to recreate these conditions andspectroscopically analyse samples or monitorprocesses in the laboratory is provided by the<strong>Specac</strong> High Temperature/High Pressure Cell.The cell has been designed for high opticalthroughput and allows simple interchangebetween its multi-purpose analysisconfigurations, Transmission, Reflectance andDecomposition (See figures 1, 2 and 3 below).Key: S = Sample W = WindowKey Features• Extreme Condition SpectroscopyProgrammable controlled temperatures upto 800°C and pressures from vacuum to1000 p.s.i.• Multi-purpose AnalyzerTransmission, specular reflectanceand decomposition.• Optimised DesignPermits easy interchange betweenanalysis modes• Safe and reliable constructionRugged, durable constructionincorporating safety approved electronicsand safety burst discFigure 1 - Transmission analysis modeApplications• Component failure• Decomposition studies• In-situ reaction monitoring• Surface emissivity measurements• Process gas analysisFigure 2 - Reflectance analysis modeFigure 3 - Decomposition analysis modewww.specac.com44


<strong>Specac</strong> Product Catalogue 2011 | High Temperature/High Pressure Cell Ordering InformationHigh Temperature/High Pressure Cell For ExtremeCondition AnalysisIn-situ analysis under extreme conditionsThe High Temperature/High Pressure Cellpermits analysis of solid samples in transmission,specular reflectance and decomposition modes;and process gases in static or flow transmissionmode. Sample temperatures of up to 800° C canbe achieved and the cell can operate atpressures from vacuum to 1000 p.s.i.The cell windows and body are separately heatedand controlled up to 200°C to preventcondensation of evolved materials adhering tothe ZnSe windows. Water cooled top and bottomblocks prevent undue heating of thespectrometer sample compartment and maintainaccessible surfaces at a safe temperature.Switching between transmission (maximumsample diameter 13mm) and specular reflectancemodes is achieved by changing an opticalpressurised window assembly on the cell bodyand fitting to an alternative baseplate.The decomposition mode is obtained by a simplerepositioning of the sample holder/heaterassembly which places the heated sample in apan just below the optical beam. Gases evolvedfrom the sample at different temperatures canthen be analyzed. The cell has provision for asteady gas flow for either gas analysis or purging.The cell volume is 80ml.Cell temperature is regulated using a dedicatedcontroller that can be programmed manually orthrough a computer. The design incorporates anumber of important safety features. In particular,all electrical supplies to the cell comply toCanadian Standards Association (CSA)regulations (30 volts or less) and the temperaturecontrollers are equipped with open circuitdetection on the thermocouple inputs to preventoverheating.The cell itself is fitted with a burst disk to preventinadvertent over pressurisation and, if necessary,this can be piped to a fume cupboard or otheroutlet point.The cell as standard is ruggedlyconstructed from durable SS316 stainless steeland can be disassembled for thorough cleaning ifrequired.Ordering InformationHigh Temperature/High Pressure CellGS05850 High Temperature/High PressureCell SystemIncludes: Optical unit with ZnSewindows and instrumentbaseplate, transmission/decomposition sample holder,programmable high stabilitytemperature controller.Please specify spectrometer make and model.GS05855 Advanced High Temperature/HighPressure Cell SystemIncludes: Optical unit with ZnSewindows and instrumentbaseplate, transmission/decomposition sample holder,reflectance mode wedgepressurised window assemblyand reflectance mode baseplate,programmable high stabilitytemperature controller.With optional RS232, RS485 or USB connectionPlease specify spectrometer make and model.GS05860 Reflectance mode kitConsists of a kit of parts to convert a GS05850HTHP cell to a fully advanced HTHP cell assupplied under GS05855GS05865 Replacement Seal kitGS05867 Replacement ZnSe cell windows(tested and certified)GS05868 Decomposition pans-Spare Set (2)GS05869 Replacement ‘Burst-Disk’OptionsGS05870GS28000GS28001GS28002HTHP Cell ESKRS232 Connection kitUSB Connection kitRS485 Connection kitELECTRICVACUUMGASWATER 5 ltr COMMS ESKwww.specac.com45


<strong>Specac</strong> Product Catalogue 2011 | Polarisers IntroductionPolarisers IntroductionPolarizers are commonly used to polarize radiation from unpolarized sources, attenuateradiation from polarized sources, or act as polarizing beamsplitters. <strong>Specac</strong> offers a range ofholographic wire-grid polarizers for use in the 2-30µm spectral range.These precision polarizers are manufactured in aclass 1000 clean room facility at <strong>Specac</strong>’s UnitedKingdom factory, by means of a holographicfabrication technique originally developed inconjunction with the United Kingdom’s NationalPhysical Laboratory (NPL).The process involves exposing a photo-resistcoating on a suitable material substrate to aninterferometrically-generated fringe pattern froma monochromatic UV source.The regular sinusoidal profile of the developedphoto-resist is subsequently metal coated at anoblique angle to create an array of fine parallellines at a set period.This technique lends itself well to the generationof extremely uniform sub-micron grid wirespacings (2500 - 4000 lines/mm), which have asignificantly reduced level of light scattering incomparison to traditional ruled wire gridpolarizers. As the wire grid is formed on thephoto-resist itself, the technique is also wellsuited to fabricating polarizers on substrates thatdo not otherwise lend themselves to the rulingprocess.<strong>Specac</strong> offers a range of polarizers on infraredmaterials such as Barium Fluoride (BaF2),Calcium Fluoride (CaF2), KRS-5, Zinc Selenide(ZnSe), and Germanium (Ge), in a range ofcategories to meet a broad scope of customerrequirements.Applications• Infrared spectroscopy of materials (typicallyplastics/polymers and crystallography)• Infrared microscopy (samplecharacterization)• NIR/Mid-IR thermal imaging systems• Plasma diagnostics• Beamsplitters in polarizedlight interferometry• Analysis in infrared astronomy• Low power laser polarization andbeam attenuation• Coupling devices for Mid-IR and longwavelength lasersStandard, High Extinction Ratio (HER), and ImageQuality High Extinction Ratio (IQ-HER) polarizersare offered mounted or unmounted, with a rangeof diameters from 25 to 75 mm depending onsubstrate material.Square polarizers in these categories are alsoavailable upon request. The performance of<strong>Specac</strong> polarizers does not vary significantly withchange of incident angle between 0 to 20degrees.www.specac.com46


<strong>Specac</strong> Product Catalogue 2011 | FTIR Infrared PolarizersFTIR Infrared PolarizersThese polarizers are offered on BaF2, CaF2, KRS-5, Ge, and ZnSe substrates. Spring mountedwith a 25mm clear aperture, they fit directly into the aperture ports of all Benchmark baseplatecompatible accessories.TransmissionEfficiency % (K1)Transmission of UnwantedRadiation % (K2)Degree ofPolarization %(K1-K2) / (K1+K2)Extinction/Contrast Ratioexpressed as K1/K2Substrate KRS-5 CaF2 BaF2 Ge ZnSeSpectral Range (µm) 2 - 35 1 - 10 1 - 12.5 8 - 12 1 - 15Grid Period (µm) 0.25 0.25 0.25 0.4 0.252.5µm 72 89 88 765.0µm 84 88 88 858.0µm 8710.0µm 75 50 84 91 742.5µm 1.50 1.00 1.10 1.405.0µm 0.50 0.28 0.30 0.508.0µm 0.3510.0µm 0.23 0.10 0.20 0.25 0.202.5µm 95.8 97.8 97.5 96.35.0µm 98.8 99.3 99.3 98.88.0µm 99.210.0µm 99.7 99.6 99.5 99.4 99.42.5µm 48:1 89:1 80:1 54:15.0µm 168:1 314:1 293:1 170:18.0µm 249:110.0µm 326:1 500:1 420:1 364:1 370:1These specifications represent typical minimum performance. Actual results may vary. Maximum operating temperature for Ge is 80°C, all others are 110°C. Other materials,including Sapphire, CsI and MgF and custom specifications available upon request.CaF 2 BaF 2Transmission %ZnSeKRS-5GeWavelength µmOrdering InformationRange (KRS-μm) OD (mm) CA (mm) t (mm) Part NumberKRS-5 2-35 34.9 25 7.9 GS12000Ge 8-12 25.0 25 7.9 GS12700Range (KRS-μm) OD (mm) CA (mm) t (mm) Part NumberBaF2 1-12.5 50.0 25 7.9 GS12900ZnSe 1-15 34.9 25 7.9 GS12950CaF2 1-10 38.0 25 7.9 GS12800Polarizer Mount and HolderGS12500 Polarizer Mount with slidemounted plate and rotating ringPolarizer KitGS12501Polarizer KitIncludes: Polarizer(please specify part number)Polarizer mount and storage casewww.specac.com47


<strong>Specac</strong> Product Catalogue 2011 | Standard Infrared PolarizersStandard Infrared PolarizersThese polarizers are offered on BaF2, CaF2, KRS-5, Ge, and ZnSe substrates, in a choice ofsupport rings. Manufactured at 4000 lines/mm, they ensure enhanced performance at shorterwavelengths for precision applications.TransmissionEfficiency % (K1)Transmission of UnwantedRadiation % (K2)Degree ofPolarization %(K1-K2) / (K1+K2)Extinction/Contrast Ratioexpressed as K1/K2Substrate KRS-5 CaF2 BaF2 Ge ZnSeSpectral Range (µm) 2 - 35 1 - 10 1 - 12.5 8 - 12 1 - 15Grid Period (µm) 0.25 0.25 0.25 0.4 0.252.5µm 72 89 88 765.0µm 84 88 88 858.0µm 8710.0µm 75 50 84 91 742.5µm 1.50 1.00 1.10 1.405.0µm 0.50 0.28 0.30 0.508.0µm 0.3510.0µm 0.23 0.10 0.20 0.25 0.202.5µm 95.8 97.8 97.5 96.35.0µm 98.8 99.3 99.3 98.88.0µm 99.210.0µm 99.7 99.6 99.5 99.4 99.42.5µm 48:1 89:1 80:1 54:15.0µm 168:1 314:1 293:1 170:18.0µm 249:110.0µm 326:1 500:1 420:1 364:1 370:1These specifications represent typical minimum performance. Actual results may vary. Maximum operating temperature for Ge is 80°C, all others are 110°C. Other materials,including Sapphire, CsI and MgF and custom specifications available upon request.CaF 2 BaF 2Transmission %ZnSeKRS-5GeWavelength µmOrdering InformationSubstrate Ring Mount Part NumberOD (mm) CA (mm) OD (mm) t (mm)KRS-525.0 unmounted N/A N/A GS5700129.0 25.0 41.0 6.7 GS5701042.0 38.0 55.0 8.7 GS5701254.0 50.0 70.0 8.7 GS5701425.0 unmounted N/A N/A GS5700329.0 25.0 41.0 6.7 GS57070Ge 42.0 38.0 55.0 8.7 GS5707254.0 50.0 70.0 8.7 GS5707475.0 71.0 90.0 9.7 GS5707625.0 unmounted N/A N/A GS5700629.0 25.0 41.0 6.7 GS57080CaF2 42.0 38.0 55.0 8.7 GS5708254.0 50.0 70.0 8.7 GS5708475.0 71.0 90.0 9.7 GS5708625.0 unmounted N/A N/A GS5700829.0 25.0 41.0 6.7 GS57090BaF2 42.0 38.0 55.0 8.7 GS5709254.0 50.0 70.0 8.7 GS5709475.0 71.0 90.0 9.7 GS5709625.0 unmounted N/A N/A GS5701629.0 25.0 41.0 6.7 GS57050ZnSe 42.0 38.0 55.0 8.7 GS5705254.0 50.0 70.0 8.7 GS5705475.0 71.0 90.0 9.7 GS5705648www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | High Extinction Ratio (HER) Infrared PolarizersHigh Extinction Ratio (HER) Infrared PolarizersThese polarizers are offered on BaF2, CaF2, KRS-5, Ge, and ZnSe substrates, in a choice ofsupport rings. Manufactured at 4000 lines/mm, with an enhanced coating process, theyensure a higher degree of polarization extinction without jeopardising transmission throughput.TransmissionEfficiency % (K1)Transmission of UnwantedRadiation % (K2)Degree ofPolarization %(K1-K2) / (K1+K2)Extinction/Contrast Ratioexpressed as K1/K2Substrate KRS-5 CaF2 BaF2 Ge ZnSeSpectral Range (µm) 2 - 35 1 - 10 1 - 12.5 8 - 12 1 - 15Grid Period (µm) 0.25 0.25 0.25 0.4 0.252.5µm 70 84 84 745.0µm 80 86 86 818.0µm 8510.0µm 72 48 80 88 722.5µm 0.35 0.25 0.28 0.525.0µm 0.15 0.13 0.15 0.208.0µm 0.1410.0µm 0.12 0.05 0.07 0.14 0.122.5µm 99.0 99.4 99.3 96.65.0µm 99.6 99.6 99.6 99.58.0µm 99.610.0µm 99.7 99.8 99.8 99.6 99.62.5µm 200:1 336:1 300:1 142:15.0µm 533:1 662:1 573:1 405:18.0µm 607:110.0µm 600:1 960:1 1143:1 629:1 600:1These specifications represent typical minimum performance. Actual results may vary. Maximum operating temperature for Ge is 80°C, all others are 110°C. Other materials,including Sapphire, CsI and MgF and custom specifications available upon request.CaF 2 BaF 2Transmission %ZnSeKRS-5GeWavelength µmOrdering InformationSubstrate Ring Mount Part NumberOD (mm) CA (mm) OD (mm) t (mm)KRS-525.0 unmounted N/A N/A GS5700229.0 25.0 41.0 6.7 GS5701142.0 38.0 55.0 8.7 GS5701354.0 50.0 70.0 8.7 GS5701525.0 unmounted N/A N/A GS5700429.0 25.0 41.0 6.7 GS57071Ge 42.0 38.0 55.0 8.7 GS5707354.0 50.0 70.0 8.7 GS5707575.0 71.0 90.0 9.7 GS5707725.0 unmounted N/A N/A GS5700729.0 25.0 41.0 6.7 GS57081CaF2 42.0 38.0 55.0 8.7 GS5708354.0 50.0 70.0 8.7 GS5708575.0 71.0 90.0 9.7 GS5708725.0 unmounted N/A N/A GS5700929.0 25.0 41.0 6.7 GS57091BaF2 42.0 38.0 55.0 8.7 GS5709354.0 50.0 70.0 8.7 GS5709575.0 71.0 90.0 9.7 GS5709725.0 unmounted N/A N/A GS5701729.0 25.0 41.0 6.7 GS57051ZnSe 42.0 38.0 55.0 8.7 GS5705354.0 50.0 70.0 8.7 GS5705575.0 71.0 90.0 9.7 GS5705749www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Image Quality Infrared PolarizersImage Quality Infrared PolarizersThese polarizers are offered on Ge and ZnSe substrates, in a choice of support rings.Anti-reflection coatings and a high specification of optical flatness and parallelism make thesepolarizers well suited for imaging applications.SubstrateZnSeGeSpectral Range (µm)Anti-reflection Coating% TransmissionEfficiency (K 1)4µm10µm3-5 8-12 8-12Yes Yes Yes93 - -- 85 90% Transmission ofUnwanted Radiation (K 2 )% Degree of (Ê 1 -Ê 2 )Polarization (Ê 1 +Ê 2 )Extinction Ratio4µm10µm4µm10µm4µm10µm0.35 - -- 0.12 0.1499.2 - -- 99.7 99.7130:1 - -- 350:1 320:1Damage Threshold (watts/cm 2 ) CWMax. Operating Temperature °C50 50 50110 110 80These specifications represent typical minimum performance. Actual results may vary. Maximum operating temperature for Ge is 80°C, all others are 110°C. Other materials,including Sapphire, CsI and MgF and custom specifications available upon request.CaF 2 BaF 2Transmission %ZnSeKRS-5GeWavelength µmOrdering InformationRange (KRS-µm) OD (mm) CA (mm) t (mm) Part NumberGe 8-12 41 25 6.7 GS570788-12 55 38 8.7 GS570798-12 70 50 8.7 GS570688-12 90 71 9.7 GS57069ZnSe 3-5 41 25 6.7 GS570583-5 55 38 8.7 GS570603-5 70 50 8.7 GS570623-5 90 71 9.7 GS57064ZnSe 8-12 41 25 6.7 GS570598-12 55 38 8.7 GS570618-12 70 50 8.7 GS570638-12 90 71 9.7 GS5706550www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Opto-Physics Infrared PolarizersOpto-Physics Infrared Polarizers<strong>Specac</strong> offer a range of opto-physics polarizers from stock in standard 25 or 50 mm supportrings. These are provided on Barium Fluoride (BaF2), Calcium Fluoride (CaF2), KRS-5, andZinc Selenide (ZnSe) substrates, and are manufactured at 2500 lines/mm to provideacceptable polarization performance at an economical price.SpecificationsWire Grid Spacing: 2500 lines/mmMounting Ring Diameters:25.0 +0.0/-0.2 mm50.0 +0.0/-0.2 mmMounting Ring Thickness:5.0 ±0.1 mm (Ø 25 mm)6.0 ±0.1 mm (Ø 50 mm)Polarizer Clear Aperture:18.0 ±0.1 mm (Ø 25 mm)34.0 ±0.1 mm (Ø 50 mm)Substrate Thickness:2.0 +0.0/-0.2 mm (Ø 25 mm)4.0 +0.0/-0.2 mm (Ø 50 mm)Typical Transmission (K1) and Attenuation (K2) Plots for <strong>Specac</strong> Economy PolarizersCaF 2 BaF 2ZnSeKRS-5SubstrateMaterialKRS-5CaF 2BaF 2ZnSeWavelength (µm) /Wavenumber (cm-1)2.5 / 40005 / 200010 / 10002.5 / 40005 / 200010 / 10002.5 / 40005 / 200010 / 10002.5 / 40005 / 200010 / 1000Typical Extinction Ratio(K1/K2)100300300100300300100300400100300400Ordering InformationPartNumberGS57500GS57501GS57502GS57503GS57504GS57505GS57506GS57507SubstrateMaterialKRS-5CaF 2BaF 2ZnSeKRS-5CaF 2BaF 2ZnSeMounting RingDia. (mm)2525252550505050Parallelism(arc minutes)53335333Flatness (fringesper inch@633 nm)42224222www.specac.com51


<strong>Specac</strong> Product Catalogue 2011 | Rotatable Polarizer MountsRotatable Polarizer MountsP/N GS57370P/N GS57350P/N GS12510The Rotatable Polarizer Mounts GS57340,GS57350, GS57360 and GS57370 aredesigned to accommodate the <strong>Specac</strong>GS57010 Series of ring mount polarizers. Whenthe polarizer is placed into its appropriate mount,the polarizing grid can be rotated for selection ofa particular degree angle of polarized light.The rotatable polarizer mounts correspond to theparticular size of GS50710 Series polarizer (seeordering information).The rotatable polarizer mounts are provided withtheir own protective covers, such that a GS57010Series ring mount polarizer can be containedsafely within the mount when not in use.The rotatable polarizer mounts are graduated in2 (two) degree angle intervals and can beestimated to 1 (one) degree accuracy. They canbe mounted directly either to a bench or via asupport post.Ordering InformationRotatable Polarizer MountsGS57340 Rotatable polarizer mount for25.0mm diameter clear aperture,ring mounted GS57010 seriespolarizers.GS57350 Rotatable polarizer mount for38.0mm diameter clear aperture,ring mounted GS57010 seriespolarizers.GS57360 Rotatable polarizer mount for50.0mm diameter clear aperture,ring mounted GS57010 seriespolarizers.GS57370 Rotatable polarizer mount for71.0mm diameter clear aperture,ring mounted GS57010 seriespolarizers.The polarizer mount GS12510 is a rotatablemount that is attached directly to the apertureports of any optical unit used with <strong>Specac</strong>Benchmark baseplate compatible accessories.Such accessories include the Golden Gate ,Silver Gate and Gateway horizontal ATRsystems and the Cyclone and Tornado longpathlength gas cells.The polarizer mount GS12510 accepts the<strong>Specac</strong> range of GS57010 Series, 38mmcircular aperture, ring mount polarizers. When apolarizer has been installed into the mount, it canbe rotated for a particular angular degree ofpolarized light by adjustment of an outer rotatingring on the polarizer mount itself.The polarizer mount GS12510 can be used whenpolarized light experimentation is to be carriedout using any of the aforementioned <strong>Specac</strong>accessories, particularly if there is limited spacewithin a spectrometer sample compartment.The standard aperture ports of the Benchmark baseplate compatible optical units will accept aGS12000 Series polarizer. To rotate this type ofpolarizer, it must be removed from the apertureport and turned to align with the indicatinggrooves in the aperture port ring for either parallelor perpendicular polarization and thenre-inserted. There is always a potential risk ofgetting fingermarks on the polarizer substratewhen placing the polarizer into or removing itfrom the aperture mounting ports. If there is arequirement for continual changing of thepolarizer orientation, the use of an appropriateGS57010 Series polarizer within the GS12510polarizer mount may help to minimise the risk ofmarking to the polarizer grid on thesubstrate surface.GS12510 Benchmark Polarizer Mount(specify KRS-5, Ge, CaF2, BaF2 or ZnSesubstrate polarizer to be used)www.specac.com52


InfraredReflectanceSpectroscopywww.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Infrared Reflectance Spectroscopy IntroductionInfrared Reflectance Spectroscopy IntroductionReflectance spectroscopy is used for samples that are difficult to analyze by transmission.An advantage of many reflectance techniques is that the samples can usually be analyzedwithout any preparation.1. Internal Reflectance- measurements: made using an ATR element incontact with the sampleInternal reflection occurs when infrared radiationenters an ATR crystal made of a highly refractiveinfrared transmitting material. ATR crystals aredesigned to enable total internal reflectioncreating an evanescent wave at the crystalsurface. This wave extends into a sample held inintimate contact with the crystal and absorptionspectra can be recorded as a result. The depthof penetration of the evanescent wave into thesample is a function of the crystal material andthe angle of incidence. Deeper penetration isachieved with either a smaller incidence angle ora lower refractive index crystal. The depth ofpenetration also increases with the wavelength.2. External Reflectance- measurements: made by collecting the infraredbeam reflected from the sample surfaceIn external reflectance, incident radiation isfocused directly on to the surface of a sample.The light reflected from the sample may bescattered in different directions or reflecteddirectly, depending upon the physical form of thesample. When reflected light is scattered by thesample it is called diffuse reflection. When it isreflected directly, it is called specular reflection.Diffuse ReflectanceIn diffuse reflection infrared spectroscopy(DRIFTS) diffusely scattered light can be collectedeither directly from a sample, or from an abrasivesampling pad previously abraded against anintractable sample. Many samples will givediffuse reflectance spectra. These includepowders, fibers or matt surfaced samples suchas textiles.Where samples have a rough surface, such as apowder, specularly reflected light is a minorcontributor to the overall signal. <strong>Specac</strong> diffusereflection accessories are optimized to increasecollection of the diffuse reflectance and decreasethe specular component, as the specularcomponent may adversely affect the spectrum.Specular ReflectanceSpecular reflectance is a nondestructive methodfor surface measurements using the mirror-likereflection from the shiny surface of a sample.Specular reflectance occurs when the reflectedangle of infrared radiation equals the angleof incidence. The amount of light reflecteddepends on the angle of incidence, and therefractive index, surface roughness, andabsorption properties of the sample. Specularreflection accessories for infrared spectroscopyare used typically to measure coatings onreflective surfaces. This type of measurement isactually a transmission measurement of thecoating, rather than a specular reflectionmeasurement from the front surface. Typicalapplications include the study of surface coatingson surface treated, painted, or polymer coatedmetals.Increased pathlengths through thin coatings canbe achieved by increasing the angle of incidence.The maximum sensitivity is achieved at the grazingangle (80-85°). Monolayer films at a liquid-airinterface can be studied using a grazing angle ofincidence. Thicker coatings, in the micrometerthickness range, are studied typically usingangles of 30°. Band intensities of the spectra alsodepend on the type and degree of polarization aswell as the effective pathlength. The <strong>Specac</strong>range of reflectance accessories includes bothfixed and variable incidence angle accessories.www.specac.com54


<strong>Specac</strong> Product Catalogue 2011 | Golden Gate Single Reflection Diamond ATRGolden Gate Single Reflection Diamond ATR Series MkIIThe Golden Gate is the world’s most versatile Infrared sampling system. It analyzes all typesof samples, from hard solids to corrosive liquids, and it is easy to use, sensitive, and robustGolden Gate Diamond ATROutstanding sensitivity is achieved using highpressure contact against a solid, type IIIadiamond, selected for its unparalleled sensitivityas a single reflection ATR element together withits unique physical and chemical stability.The accessory can be used to analyze a range ofsamples from single particles and fibers tocorrosive liquids. While the large working areasample platform is ideal for macro sampling.The diamond is high temperature bonded into itstungsten carbide mount, giving performance andstrength to withstand the high pressures requiredfor maximum optical contact with hard samples.The quick lock and release bridge allows for fastsample change around. The built-in pressurecontrol mechanism means reproducible resultsre obtainable and optimum sample clamping isachieved.Key Features• High sample throughput - no samplepreparation• Rugged type IIIa diamond ATR metalbondedinto a tungsten carbide mount• Hard, inert, sapphire self-levellingpressure anvil• Pressure bridge for highest sensitivity• A wide choice of available options• Quick release bridge with safety interlock• Built-in pressure control for reproducibleresultsApplications• QA on pharmaceutical powders• Analysis of hard and soft polymer pellets• Forensic sampling, paint chips andsingle fibers• Hard samples, e.g. rock and geochemicals• Corrosive liquids• Coated wires• Air sensitive sampleswww.specac.com55


<strong>Specac</strong> Product Catalogue 2011 | Golden Gate Single Reflection Diamond ATRReproducibility and Sensitivity of the Golden Gate Single Reflection ATR System0.41.20.350.3Lacquer on Copper WirePaper SampleWool/Polymer ClothSweetner (powder)Nylon MonofilamentSingle Human Hair10.80.25Absorbance0.2Absorbance0.60.150.4Hard Red Polymer0.1Soft Polymer PelletPeet Tubing0.2Hard ABS PelletSoft Polyurethane0.05Polythene SheetPTFE SheetIrregular Peet Pellet0020 40 60 80 100 120 140 160 180 200Applied Load (lbs)0020 40 60 80 100 120 140 160 180 200Applied Load (lbs)Typical competitive ATR pressure rangeTypical competitive ATR pressure rangeGolden Gate pressure rangeGolden Gate pressure rangeThe effect of load on ATR sensitivityA key feature of the Golden Gate SingleReflection ATR System is the outstanding contactachievable between solid samples and thediamond crystal.For many sample types (particularly powders andfibers), as the load is applied to the sample andoptical contact between the diamond and thesample increases, the intensity of theabsorbance bands also increase. In other words,increasing the load increases the sensitivity. TheGolden Gate gives the highest load capability ofany commercial diamond ATR (over 180 lbs) andthe diagrams above illustrate how that impactssensitivity for a variety of sample types.For softer samples, such as polymers, a similareffect is seen. However, once the sample hasfully contacted the ATR surface, the absorbancestops increasing with increasing pressure.In order to achieve the best measurementrepeatability and reproducibility for thesesamples, the instrument should ideally apply aload above the “knee” of the curve where theabsorbance becomes much less sensitive toload. The diagram above right illustrates somemeasurements for typical samples. Note how theharder sample types need a higher load to reachthis ideal situation - and very often the GoldenGate is the only product that can do it.0.70.50.6Absorbance / a.u.0.40.30.20.1WaterAbsorbance / a.u.0.50.40.30.20.1Polyethylene glycol (PEG 600)0.00.03900 3600 3300 3000 2700 2400 2100 1800 1500 1200 900 6003900 3600 3300 3000 2700 2400 2100 1800 1500 1200 900 600Wavenumber cm -1Wavenumber cm -11.20.400.35Absorbance / a.u.1.00.80.60.40.2Polydimethylsiloxane (PDMS)Absorbance / a.u.0.300.250.200.150.100.05Hexadecane (C 16 H 34 )0.00.003900 3600 3300 3000 2700 2400 2100 1800 1500 1200 900 600Wavenumber cm -1-0.053900 3600 3300 3000 2700 2400 2100 1800 1500 1200 900 600Wavenumber cm -1www.specac.com56


<strong>Specac</strong> Product Catalogue 2011 | Golden Gate Single Reflection Diamond ATRSchematic of the Golden Gate Single ReflectionATR systemBeam Condensing LensesThe Top-plates of the Golden Gate SingleReflection ATR Series are supplied on an opticalunit which contains mirrors and a choice of beamcondensing optics (ZnSe or KRS-5).All Top-plates are interchangeable with theoptical unit.A schematic is shown opposite of the beam paththrough the Golden Gate optical system. Thesymmetrical design coupled with the use of theBenchmark base-plate system means that theGolden Gate can be used in most commerciallyavailable FTIR instruments.Golden Gate Anvil OptionsA variety of special anvils are available for use with the Golden Gate Top-plates. The useof an appropriate anvil improves the sample handling capabilities of the Golden Gate Single Reflection ATR System.67128 93541 Reactive Sample AnvilSamples which are sensitive to air or moisturecan be loaded and pressed in a dry box. Theanvil has a seal which compresses as the sampleis pressed, thus keeping it in an inert environmentwhile the spectrum is being run.2 & 5 Grooved Anvils(Narrow and Wide) To study the coating ontransformer wire the grooved anvils hold the wireexactly in the middle of the diamond.3 Sapphire AnvilThis is the standard anvil and is used for mostsample types. It has the advantage of being veryhard, and easy to clean to prevent sample carryover.It is also self-leveling to accommodate nonflatsamples.4 Stainless Steel Flat AnvilThis is used for fibers or fine wires. It is not selfleveling,which can be an advantage with thistype of sample.6 Pellet AnvilPolymer pellets are held firmly in position with thisconcave anvil. With a flat anvil they could movewhen pressure is applied.7 Volatiles CoverIf liquid samples are very volatile the cover isuseful to minimize evaporation.8 View-Thru AnvilThe View-Thru Anvil allows the sample to beviewed through a 4x lens system with a built-inreflective illuminator.9 Flow-Thru AnvilThis micro flow cell anvil seals under pressurearound the diamond. Its volume is 28 microlitersand it can operate at 1000 psi. It may be used asa flow cell or as a micro reaction chamber.www.specac.com57


<strong>Specac</strong> Product Catalogue 2011 | Golden Gate Top-plate OptionsGolden Gate Top Plate OptionsHigh Temperature Top-plateKey Features• Heatable to 300ºC• Diamond in tungsten carbide mount• Low voltage heaters• Thermal safety fuses• Programmable temperature control viaoptional RS232, RS485 or USB connection• Complies with CE regulations• Low thermal massMany reactions and processes occur at hightemperatures. The Heated Diamond Top-plateincludes all the normal features of the GoldenGate sampling technique but with the addedbenefit of heating samples up to 300ºC. Diamondhas a uniquely high thermal conductivity.The Top-plate has a low thermal mass, and incombination with high power heaters in closeproximity to the diamond, both rapid and efficientheating is achieved. This gives a high degree oftemperature control. A rapid sample turn aroundis therefore possible. The Top-plate can be usedApplications• Polymerization studies• Thermochemical studies• Curing reactions• Degradation / decompositionwith a computer controlled temperaturecontroller with digital readout to 1°C. With safetyin mind, low voltage (30V) heaters are used, andfor additional protection thermal fuses are fittedas standard. The controller complies withEuropean CE regulations.ELECTRICReaction CellKey Features• Controlled temperatures to 200ºC• Low voltage (30V)• Cell volume 28ml• Pressures up to 3000psi• Water jacket to prevent overheating• Stainless steel construction with a choiceof other materials• Stirring option• Flow through configuration optionThe Reaction Cell allows in-compartmentreaction monitoring over a broad range ofextreme conditions. The diamond is metalbonded into a tungsten carbide mount and this iscontained within a high pressure reaction vessel.The unique strength and durability of the diamondelement makes it ideal for withstandingcombinations of aggressive chemical contact athigh temperatures and pressures.Applications• Chemical reaction analysis at hightemperatures and pressures• Caustic solutions• Slurries with abrasive particulates• Acidic reactions• Optimization of process parametersELECTRICGASWATER 5 ltrwww.specac.com58


<strong>Specac</strong> Product Catalogue 2011 | Golden Gate Top-plate OptionsLow Temperature Top-plateKey Features• Continuous control of sample temperaturefrom -150°C to 80°C.• High thermal conductivity provides rapidcooling and temperature stabilization• Proven, strong clamping device, based onthe Golden Gate Diamond ATR, allowsrapid, reproducible sample throughput.• Thermally insulated copper and stainlesssteel dewar allows for the use of liquidnitrogen, dry ice, or salt & water mixtures.The Golden Gate low temperature diamond ATRsystem is the first ATR accessory to provide highperformance ATR measurements down to nearliquid nitrogen temperature. The system uses athermally insulated copper and stainless steeldewar in conjunction with an integral heaterThe high thermal conductivity of the diamondcrystal provides rapid temperature stabilization,accurate temperature measurement, and avoidstemperature gradients across the sample.The diamond ATR crystal is high temperaturemetal bonded into a tungsten carbide supportdisk and the top plate is hard-anodized to makethe accessory chemically resistant and capableof withstanding the pressures required foroptimum crystal and sample contact. Pressure isapplied to the sample using the quick lock andrelease bridge from the proven Golden Gate diamond ATR system.This clamping device allows rapid samplethroughput and reproducible solid sampling.It also has a built-in torque limiter to control theloads applied to the diamond.The Golden Gate low temperature diamond ATRis constructed in such a way that the crystalmounting is under a constant load. This ensuresthat the diamond is kept in constant opticalalignment, negating the effects of thermalexpansion and contraction. The upper thermaldewar body of the system is separated from thetop-plate by a replaceable, thermally conductingspacer, avoiding the need for use of sealants thatmay contaminate the diamond surface. The systemis easily and quickly taken apart for cleaning.ELECTRICMicro Specular Reflectance Top-plateApplications• Micro reflectance samples• Very highly absorbing samples• Carbon black containing polymersA 45º angle Micro Specular Reflection Top-plateis for flat samples of greater than 3mm x 6mm,or powders that can be pressed into a selfsupportingwafer. A scribed reference grid allowsaccurate repeat positioning of samples.www.specac.com59


<strong>Specac</strong> Product Catalogue 2011 | Golden Gate Top-plate OptionsSupercritical Fluids Top-plateKey Features• Pressures up to 6000 p.s.i• Temperature controlled to 300°C• Low volume 28µl stainless steel sample cell• Standard 1/16th inch fittings• CE MarkedThe Supercritical Fluids Analyzer version of theGolden Gate Diamond ATR is designed foroperation at extreme temperatures andpressures. The diamond ATR element is hightemperature metal bonded into a tungstencarbide disk, avoiding the use of adhesives orresins that may be dissolved or attacked by thechemical aggressiveness of supercritical fluids.The sample chamber has been speciallyconstructed using stainless steel and is capableof withstanding pressures up to 6000 p.s.i. andOrdering InformationGolden Gate ATR Mk II seriesA Complete Golden Gate ATR Mk II Systemconsists of an Optics Unit with ZnSe or KRS-5Lenses, Top-plate (GS10563), Baseplate andPurge Bellows.Please specify Spectrometer make and model forthe appropriate baseplateApplications• Supercritical and Near Supercritical fluids• Extreme condition analysis of polymers• In-situ ATR studies at high temperaturesand pressurestemperatures up to 300°C. The high thermalconductivity of the diamond element is ideal forfast temperature equilibrium and accuratetemperature measurement, reducing analysistime and increasing sample throughput.The analyzer is equipped with a thermalprotection system to prevent thermal runaway.ELECTRICGASGS10500 Complete Golden Gate ATR Mk IIwith ZnSe LensesGS10515 Complete Golden Gate ATR Mk IIwith KRS-5 LensesA Golden Gate top-plate can be provided as acomplete accessory on a ZnSe or KRS-5 lensoptical unit or as an upgrade additional top-plateESKTop-Plate OptionsGS10563 Diamond ATR Top-plate Mk IIIncludes: Sapphire and Pelletanvils, volatiles coverGS10566 Germanium ATR Top-plate Mk IIIncludes: Large stainless steelanvil and volatiles coverGS10514 Micro Specular ReflectanceTop-plateIncludes: Reference mirrorGS10507 In-Situ Reaction Cell Top PlateIncludes Temperature controller.Specify 220V or 110V and country for controllerGS10513 Stirring option for Reaction CellGS10585 Supercritical fluids top-plate.Includes Temperature controllerSpecify 220V or 110V and country for controllerGS10590 Low Temperature Diamond ATRTop PlateIncludes Temperature controllerSpecify 220V or 110V and country for controllerGS10640 High Temperature top-plateIncludes Sapphire and Pelletanvils, volatiles cover andtemperature controllerSpecify 220V or 110V and country for controllerwww.specac.com60


<strong>Specac</strong> Product Catalogue 2011 | Golden Gate Ordering InformationOrdering information cont’dAccessory OptionsGS10642Heatable Golden Gate ATR Mk IIA Complete Heatable GoldenESKGate ATR Mk II Systemconsisting of an Optics Unit withZnSe or KRS-5 lenses, HeatedTop-plate, Baseplate, PurgeBellows and TemperatureController.Specify Spectrometer make and model for theappropriate baseplate - 220V or 110V and countryfor the Controller and ZnSe or KRS-5 lenses.GS10586 Supercritical fluids Golden Gate ATR MK IIESKA Complete Supercritical fluidsGolden Gate ATR Mk II Systemconsisting of an Optics Unit withZnSe or KRS-5 lenses,Supercritical fluids, Top-plate,Baseplate, Purge Bellows andTemperature Controller.Specify Spectrometer make and model for theappropriate baseplate - 220V or 110V and countryfor the Controller and ZnSe or KRS-5 lenses.GS10592 Low Temperature Golden Gate ATR MK IIESKA Complete Low TemperatureGolden Gate ATR Mk II Systemconsisting of an Optics Unit withZnSe or KRS-5 lenses, LowTemperature, Top-plate, Baseplate,Purge Bellows and TemperatureController.Specify Spectrometer make and model for theappropriate baseplate. 220V or 110V and countryfor the Controller and ZnSe or KRS-5 lenses.GS10525 Reaction Cell Golden Gate ATR MK IIESKA Complete Reaction Cell GoldenGate ATR Mk II Systemconsisting of an Optics Unit withZnSe or KRS-5 lenses, ReactionCell Top-plate, Baseplate, PurgeBellows and Temperature Controller.Specify Spectrometer make and model for theappropriate baseplate. 220V or 110V and countryfor the Controller and ZnSe or KRS-5 lenses.GS10513 Stirring option for Reaction CellUpgrade - LensesGS10552 ZnSe lens upgrade kit6500 - 600cm-1GS10508KRS-5 lens upgrade kit6500 - 400cm-1Anvil Options - Mk II Golden Gate Top-platesGS10503 Volatiles coverGS10531 Sapphire anvilGS10532 Pellet anvilGS10536 Reactive sample anvilGS10547 Grooved anvil - narrow gaugeGS10548 Grooved anvil - wide gaugeGS10549 Stainless steel flat anvilGS10567 Stainless steel large anvil forGermanium Top-plateGS10568 Micro Reaction/Flow Cell anvilGS10569 View-Thru Anvil/Bridge assemblySparesGS10707Purge bellowsMk I to Mk II Top-plate UpgradeGS10564 <strong>Specac</strong> can upgrade an existingMk I (Pre Oct 1999) Golden GateTop-plate to a Mk II version with aquick lock and release bridge andin-built pressure mechanism.The upgrade includes Sapphireanvil P/N GS10531 and PelletAnvil P/N GS10532.Return your Mk I Top-plate to your <strong>Specac</strong> Dealerfor the upgrade.GS10550 Golden Gate ATRAccessories ESKGS10527 Golden Gate MicrospecularATR ESKGS10528GS10529OptionsGS28000GS28001GS28002Golden Gate Reaction CellATR ESKGolden Gate SCF ATR ESKRS232 Connection kitUSB Connection kitRS485 Connection kitwww.specac.com61


<strong>Specac</strong> Product Catalogue 2011 | Silver Gate Evolution Single Reflection ATRSilver Gate Evolution Single Reflection ATRA cost-effective, basic, high throughput single reflection ATR accessory for the FTIR analysisof solids, liquids, gels and pastes - with interchangeable crystal plates.Silver Gate EvolutionThe Silver Gate Evolution single reflection ATRsystem is a high throughput FTIR accessorycapable of analysing solids, liquids and pasteswith little or no sample preparation.The Silver Gate Evolution standardconfiguration has an interchangeable crystalplate with replacement crystal plates availableat reasonable prices.The sampling surface can be flat or recessed -depending on customer requirements and canbe bought with or without the clamp bridge.Stability and high sample throughput is providedby the built-in torque limiter which controls theapplied load and the Benchmark baseplatemounting system allows the Silver Gate Evolution to be rapidly mounted in thespectrometer without re-alignment.The Silver Gate Evolution single reflection ATR isextremely robust and the factory pre-alignedoptics help make it an ideal cost-effectiveaccessory for quality assurance andsample analysis.Key Features• Rapid analysis of solids, liquids, gels andpastes with little or no sample preparation• High optical throughput provides fast andefficient sample measurement• Proven, strong clamping device, based onthe Golden Gate ATR technology, allowsrapid, reproducible sample throughput• Flat crystal surface provides optimumsample contact and prevents point loadingand stray light• Open top-plate architecture for easysample accessApplications• Highly absorbing samples• Small samples• Liquids, semi-solids, films and finelymilled powderswww.specac.com62


<strong>Specac</strong> Product Catalogue 2011 | Silver Gate Evolution Ordering InformationSilver Gate Evolution Ordering InformationPlease specify if a base plate is required, andfor what make and model of spectrometerSilver Gate Optics UnitGS10681 Silver Gate Evolution Optics UnitNote: the Optics Unit includes a volatiles coverand purge bellowsSilver Gate Evolution Top PlatesGS10682-1 Top Plate without clamp bridgeGS10682-2 Top Plate with clamp bridgeNote: GS10682-2 includes both Pellet andPlane AnvilFully configured Silver Gate EvolutionGS10680-1 ZnSe flat crystal platewith clamp bridgeGS10680-2 Ge flat crystal platewith clamp bridgeGS10680-3 ZnSe recessed crystal platewith clamp bridgeGS10680-4 Ge recessed crystal platewith clamp bridgeGS10680-5 ZnSe flat crystal platewithout clamp bridgeGS10680-6 Ge flat crystal platewithout clamp bridgeGS10680-7 ZnSe recessed crystal platewithout clamp bridgeGS10680-8 Ge recessed crystal platewithout clamp bridgeSilver Gate Evolution Crystal PlatesGS10683-1 ZnSe flat crystal plateGS10683-2 Ge flat crystal plateGS10684-1 ZnSe recessed crystal plateGS10684-2 Ge recessed crystal plateSilver Gate Evolution Replacement partsGS10503 Volatiles CoverGS10532 Pellet AnvilGS10567 Plane AnvilGS10707 Purge BellowsGS10685 Silver Gate Evolution ESKHigh optical throughput provides fast andefficient sample measurementAbsorbance / a.u.Absorbance / a.u.0.50.40.30.20.1Water0.03900 3600 3300 3000 2700 2400 2100 1800 1500 1200 900 600Wavenumber cm -10.70.60.50.40.30.2Polyethylene glycol (PEG 600)0.10.03900 3600 3300 3000 2700 2400 2100 1800 1500 1200 900 600Wavenumber cm -11.21.0Absorbance / a.u.0.80.60.4Polydimethylsiloxane (PDMS)0.20.03900 3600 3300 3000 2700 2400 2100 1800 1500 1200 900 600Wavenumber cm -10.400.35Absorbance / a.u.0.300.250.200.150.10Hexadecane (C 16H 34)0.050.003900 3600 3300 3000 2700 2400 2100 1800 1500 1200 900 600Wavenumber cm -1www.specac.com63


<strong>Specac</strong> Product Catalogue 2011 | Gateway ATR SystemGateway ATR SystemAn advanced 6 reflection ATR system for the infrared analysis of solids, liquids, pastes and gelsKey Features• Replaceable crystals• High optical throughput• Purgeable optics• Extensive range of optional top plates• Benckmark base-plate systemGateway ATR SystemThe <strong>Specac</strong> Gateway ATR system is a low costmulti-reflection horizontal ATR accessory.High performance transfer optics and antireflectioncoated ZnSe crystals ensures unrivalledthroughput and sampling sensitivity.The rugged design, simple optical layout and<strong>Specac</strong>'s unique Benchmark base-platesystem ensures optimum performance no matterwhich instrument make or model you use. Thestandard dual top plate configuration offers themost versatile package while optional, additionaltop plates allow sampling flexibility and systemexpandability.For the study of samples at elevated temperaturesup to 200°C, there is an additional option ofthe electrically heated trough top plate with 45°angle ZnSe crystal and dedicated temperaturecontroller P/N GS11155. The plate is an opentrough design similar to the standard trough topplate P/N GS11166, whereby a liquid is simplypoured in to cover the crystal. The thermostabilizedopen trough top plate P/N GS11139 issimilar to the P/N GS11155 top plate, but relieson a thermocirculating fluid for heating ratherthan from an electrically powered temperaturecontroller.An alternative type of heatable top plate forGateway ATR is the 550 microliter thermostabilizedflow through top plate assembly with45° angle ZnSe crystal P/N GS11118.Applications• Aqueous solutions• Liquids – static or flowing• Pastes and gels• Polymer films• Fine powders• Quality control• Temperature sensitive samples• Reaction kinetics• EducationA liquid sample can be flowed across thesampling surface of a ZnSe crystal in an enclosedchamber. The outer casing can be heated by theflow of a thermocirculating solution surroundingthe sample/crystal area. The temperatureachievable is dependent upon the thermocirculatingfluid being used i.e. water or oil, etc.A liquid sample pumping system can be used fordelivery of the liquid sample via peristaltic typeflow through flexible tubing attached to thesample ports on the flow plate. The sample flowthrough the thermostabilized flow through topplate is rated up to a 60psi maximum.There is also a room temperature flowthroughtop plate version with 550µl volume P/NGS11116.All of the Gateway ATR top plates are suppliedwith a 45° angle ZnSe crystal P/N GS11145, butalternative germanium P/N GS11147 and siliconP/N GS11146 crystals at a 45° angle are alsoavailable. They can be supplied on their own forplacement into the trough or thermostabilized topplates, but they must be pre-affixed into a flat topplate assembly.www.specac.com64


<strong>Specac</strong> Product Catalogue 2011 | Gateway ATR System Top-plate OptionsGateway ATR Top Plate Options Ordering InformationGS11133Flat top-plate• Ideal for solids or films• Variety of crystals availableGS11166Trough top-plate• Ideal for liquids and pastes• Removable crystal• Variety of crystals availableGS11116Flow thru top-plate• Process control• 550µl volume• Removable crystal• Variety of crystals available• Reaction monitoringGS11118WATER 5 ltrThermostabilized Top Plate• Reaction kinetics• 550µl volume• Removable crystal• Stainless steel top plate andKalrez spacer• Heatable to 90ºCWater heated trough top-plateGS11139 A sub ambient to 90°Ctop-plate heated or cooled byWATER 5 ltr thermocirculating fluidGS11155ELECTRICElectrically heatedtrough top-plateAn electrically heated top platewith dedicated temperaturecontroller. This top plate is heatableto 200ºC.www.specac.com65


<strong>Specac</strong> Product Catalogue 2011 | Gateway ATR SystemGateway ATR Example Spectra63.052.5Absorbance / a.u.4321WaterAbsorbance / a.u.2.01.51.00.5Polyethylene glycol (PEG 600)00.03900 3600 3300 3000 2700 2400 2100 1800 1500 1200 900 6003900 3600 3300 3000 2700 2400 2100 1800 1500 1200 900 600Wavenumber cm -1Wavenumber cm -14.02.03.5Absorbance / a.u.3.02.52.01.51.0Polydimethylsiloxane y (PDMS)Absorbance / a.u.1.51.00.5Hexadecane (C 16 H 34 )0.50.00.03900 3600 3300 3000 2700 2400 2100 1800 1500 1200 900 6003900 3600 3300 3000 2700 2400 2100 1800 1500 1200 900 600Wavenumber cm -1Wavenumber cm -1Gateway ATR Top Plate Options Ordering InformationGS11165 Gateway Combination systemIncludes: optics unit, Benchmarkbase-plate, ZnSe trough and flattop plates, sample clamp,purge bellowsOptional Top PlatesGS11118 550µl Thermostabilized FlowThrough Top Plate withZnSe 45° crystalGS11116 550µl Flow Through Top Platewith ZnSe 45° crystalGS11139 Water Heated/Cooled Trough TopPlate with ZnSe 45° crystalGS11155 Electrically Heated Trough TopPlate with ZnSe 45° crystal & AutoTemperature Controller (200°C)(Specify 220V or 110V)Other OptionsGS11132 Volatiles CoverOptionsGS28000 RS232 Connection kitGS28001 USB Connection kitGS28002 RS485 Connection kitSpares and ConsumablesGS10707 Pair of Purge Bellows forenclosing Benchmark ATR beampath in spectrometer samplingcompartmentGS11129 Gasket Replacement Kit for 11130,11139 and 11155 Top PlatesGS11167 Kalrez Gasket Set forTrough Top-platesGS11152 Silicone tubing for Flow ThroughTop-platesGS11133 ZnSe Flat top plateGS11145 Replacement ZnSe crystal for alltop plates (except Flat GS11133)GS11150 Kalrez Gaskets for 550 l Top PlatesGS11166 ZnSe Trough top plateGS11170 Gateway optics unit onlyGS11171 Sample ClampOther crystal materials available on request.www.specac.com66


<strong>Specac</strong> Product Catalogue 2011 | 25 Reflection ATR25 Reflection ATRFor high sensitivity ATR measurements with FT-IR or dispersive instrumentsKey Features• Variable angle of incidence (30º - 60º)• 25 Reflections• Suitable for both FT-IR and dispersiveinstruments• Two pin sample location on sample mount• Standard 3” x 2” slide mounting• Choice of crystal materials; KRS-5 asstandard• Interchangeable sample holders (solids,liquids and pastes)Applications• Solids• Liquids• Pastes• Variable depth studies for coatingsand films25 Reflection ATRThe 25 Reflection Variable Incidence ATR (P/NGS11000) is a vertically mounted ATR crystalaccessory capable of being operated for acrystal incidence angle of between 30º to 60º.The angle of incidence for the crystal is quicklyand easily selected by rotation of a knurledadjustment screw. This moves the sample holderand crystal assembly to the correct positionwhen the back face of the holder is in line withthe required angle setting as indicated on thegraduated plate.The standard crystal holder (P/N GS11001)supplied with the ATR Accessory is for solidsamples, but a liquids holder (P/N GS11003) anda paste holder (P/N GS11002) are available onrequest. Although the sample holder and crystalassembly can be positioned between the anglesof 30º to 60º, it is only when the holder andcrystal assembly are correctly aligned at the 45ºangle, that 25 internal reflections are obtainedwithin the crystal. Sufficient sample is required tocover both faces of the trapezium shaped crystalfor 25 reflection events to be measured.The ATR Accessory is supplied with a KRS-5crystal as standard, but a variety of crystalmaterials such as ZnSe, Ge and Si are availableto extend the sample handling and studycapabilities of the accessory.The IR beam is directed through and collectedfrom the crystal by four mirrors which areadjustable for both their rotation and tilt.The accessory is supplied with a standard 3” x 2”mounting plate that allows it to be positioned inthe spectrometer sample compartment using theinstruments own 3” x 2” mounting baseplate.In addition, the accessory is supplied with asupport foot that is used in one corner of thebase. The foot is adjustable for height to providemechanical stability of the accessory whilst in thesample compartment. A thumb nut locks the footin position.Ordering information25 Reflection Variable Incidence Angle ATRGS11000 Includes: Solids holder and KRS-5crystal (45°)OptionsGS11001 Solids holder for 25 Reflection ATRGS11002 Paste holder for 25 Reflection ATRGS11003 Liquid holder for 25 Reflection ATRSpares and ConsumablesGS11004 KRS-5 crystal (45°)GS11006 Ge crystal (45°)GS11009 Si crystal (45°)GS11014 ZnSe crystal (45°)GS11008 PTFE gaskets (1 large, 1 small) forliquid holder (5 sets)www.specac.com67


<strong>Specac</strong> Product Catalogue 2011 | The Selector 68The Selector An expandable diffuse reflectance sampling system that can change with your applicationsKey Features• Diffuse or total reflectance capabilities• Minimal alignment• Easy sample handling• Macro, micro and tilted cups• Diabrase synthetic diamond abrasive pads• Sampling expandability via specialbaseplate optionApplications• Powders• Intractable solids• Liquid samples as a dispersion overKBr matrixThe Selector Diffuse reflectance is based upon the collectionof radiation that has been diffusely scatteredfrom the sample. The <strong>Specac</strong> Selector uses anoptimized off axis optics configuration whichselectively collects the diffusely reflectedcomponents, whilst minimizing the specularcomponent.Various sampling cups are offered including astandard 11 mm diameter cup, a micro 4 mmdiameter cup, and tilted cups. The tilted cupsallow for collection of total reflectance, diffuseand specular components. In addition, anabrasive sampler, 12 mm diameter, can be usedwith Diabrase pads to allow quick and easysample preparation of intractable solids.The abrasive pad is simply rubbed against thesample of interest and mounted in the Selector accessory. The Selector is mounted on its ownbaseplate. The off-axis design allows room forthe use of specialist alternative configurations.The Environmental Chamber option (see nextpage) extends the sampling capabilities of theSelector .Ordering informationThe Selector Diffuse Reflectance SystemGS19900 The Selector includes opticalunit with dedicated baseplateMicro sample cup(4mm diameter)2 Standard cups (11mm diameter)Diabrase abrasive sample pads12mm diameter (20)2 Mounts for abrasivesample padsTilted cup for total reflectancemeasurements(Please specify spectrometer make and model)www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | The Selector - OptionsEnvironmental Chamber option for The Selector A water cooling jacket keeps the outside of thechamber cool when operating at hightemperatures and a safety “burst disk” activateswhenever the pressure exceeds therecommended safety limit.The Environmental Chamber, in conjunction withthe Selector, is ideal for use in chemicalresearch such as kinetics, catalysis, surfaceanalysis, polymerization and co-ordinationchemistry.Key Features• Programmable controlled temperaturesto 800ºC• Operates from vacuum (10 -3 Torr) to highpressure (500 psi)• Provides controlled atmosphere (gas inletand outlet)• Extensive safety featuresEnvironmental ChamberThis accessory allows for the study of diffuselyreflecting solid samples in a controlledatmosphere ranging from ambient temperatureto 800°C, and vacuum (10-3 Torr) to 500 p.s.i.pressure.The standard chamber window is ZnSe, whichgives a good balance between IR transmissionand mechanical strength. Other opticaltransmitting windows are available on request.The body is constructed from 316 stainless steelfor ruggedness and chemical resistance.Safety features include a low voltage automaticpower supply and an automatic shut-downfeature, should the temperature sensor detectan overheating fault.Ordering informationEnvironmental ChamberGS19930 Environmental Chamber andHigh Stability Controller withRS232 interface.Please specify spectrometer make and model.Please specify 220V or 110V & country of usageOptionsGS28000 RS232 Connection kitGS28001 USB Connection kitGS28002 RS485 Connection kitThe Selector - Spares & ConsumablesGS03610 KBr powder (50g)GS19915 4mm diameter micro cup forthe SelectorGS19916 11mm diameter standard cupfor the SelectorGS19917 Tilted cup for total reflectancemeasurementsGS19918 Abrasive pad sample mountfor the SelectorGS19919 Diabrase abrasive sample pads12mm diameter for Selector (100)GS19931 Environmental Chamber ESKELECTRIC VACUUM WATER 5 ltrESK COMMS GASwww.specac.com69


<strong>Specac</strong> Product Catalogue 2011 | Minidiff PlusMinidiff PlusA diffuse reflectance accessory for routine analysisMinidiff PlusFor routine diffuse reflectance sampling,theMinidiff Plus is the ideal accessory of choice.High performance solids analysis is made simplethrough a minimal alignment optical system. Solidsampling versatility is maintained through the useof standard sampling cups and Diabrase abrasivesampling pads. The sample introduction systemreduces the risk of sample spillage, with up to 3samples being loaded at the same time. TheBenchmark baseplate mounting providesconsistent, stable and reliable positioning of theaccessory in the spectrometer.Key Features• Pre-aligned mirrors• Easy sample handling• Diabraze sampling• Benchmark baseplate mounted• Micrometer focusing adjustmentApplications• Powders• Intractable solids• Liquid samples as a dispersion overKBr matrixOrdering informationMinidiff Plus Diffuse Reflectance AccessoryGS04510 Includes: Optical unitand baseplateAbrasive sample holders with3 mounts (2)Sample cup holders with3 cups (2)Diabrase abrasive pads(9mm diameter) (20)KBr Powder (50g)Pestle and MortarSpares and ConsumablesGS03610 KBr powder (50g)GS04505 Sample cup holders with3 cups (2)GS04506 Diabrase abrasive pads(9mm diameter) forMinidiff Plus (100)GS04508 Abrasive sample holders with3 mounts (2)www.specac.com70


<strong>Specac</strong> Product Catalogue 2011 | Monolayer/Grazing Angle Specular ReflectanceMonolayer/Grazing Angle Specular ReflectanceKey Features• Grazing angle capability• Monolayer analysis• Continuously variable incidence anglesfrom 8º - 85º(dependant on spectrometer)• Volume of trough 8.9ml• Sample size 85 x 22mm liquid& 140 x 35mm solid• Built-in polarizer mount• Aperture stop facility for controlling thesampled area• Liquid film compression/expansioncapability• Inert PTFE sample trough (liquids)Applications• Reflection-absorption spectra of solids• Langmuir-Blodgett films• Surfactant studies• Liquids in biological membranes• Semi-conductors• Paints• Resins• Polymer coatings• Matt surfaced samples• Molecular orientation of surfacesEnvironmental ChamberThe Monolayer/Grazing Angle SpecularReflectance Accessory P/N GS19650 is a dualpurpose sampling device designed to provide themeans of in-situ FTIR monolayer investigation offilms at an air/liquid interface and grazingincidence angle measurements of thin filmcoatings on solid reflective surfaces. Theaccessory can be easily converted from oneform to the other by simple changeover of theappropriate sample holder.The range of grazing incident angles availablewith this accessory are from 8º to 85º with nostray light, on most spectrometer systems.Aperture stops are provided to redefine thebeam profile, for prime position on samples at ornear grazing angles, to enhance theperformance.In the monolayer mode a variety of monolayersystems including surfactants, proteins,detergents, oils, polymers and phospholipids inbiological membranes can be studied in theirnative environment for information such assolvation, molecular orientation, configurationand phase transition. A special liquid samplingtrough, fabricated in PTFE, is used to contain thesample of interest. A rotatable polarizer mountand surface film stretching device are provided toaid in the studies. Any of <strong>Specac</strong>’s P/N GS12000series polarisers can be placed into the polarizermount. The polarizer substrate chosen willdetermine the frequency range that can beobserved in the Mid IR.www.specac.com71


<strong>Specac</strong> Product Catalogue 2011 | Monolayer/Grazing Angle Ordering InformationFor solid surface sampling, an alternative flatsampling stage is used within theMonolayer/Grazing Angle accessory in place ofthe liquid sampling trough.An important point about the sampling arearequirement for the monolayer grazing angleaccessory is that it is chiefly dependent on theincident angle of the beam of light beingprojected to the sample surface.Whether it is a liquid sample or a solid surface,as the angle gets shallower (i.e. towards the 85degree maximum for monolayer experiments)the spread of light across the surface gets largeras the elliptical shaped pool of light gets longer.You therefore need a longer and thinner samplesize area to make use of the available light, tomaximise a sample signal. At grazing angles theamount of specularly reflected light can be verylow in intensity and hence <strong>Specac</strong> would normallyrecommend that a sensitive detection systemsuch as an MCT detector is used formeasurement.For liquid samples, the maximum length andwidth for a liquid surface is limited to 85mm and22mm respectively. For the solid samplingplatform, the maximum length of sample that canbe accommodated is 140mm and the maximumwidth is 35mm.The Monolayer/Grazing Angle accessory isbaseplate mounted within a spectrometersample compartment and an appropriatebaseplate or fixings are supplied when orderedfor a specific spectrometer system. It is notcompatible for attachment to a Benchmark stylebaseplate. However, in the majority of instances,the Monolayer Grazing Angle accessory can beadapted for use in a different spectrometersample compartment by simple changeover tothe appropriate baseplate.Ordering informationMonolayer/Grazing Angle AccessoryGS19650 Includes: Optical unit withbaseplateHorizontal sample stageAperture stopsPolarizer mountPTFE sample troughSuitable for most spectrometers – please specifymake and modelSpares and ConsumablesGS19662 PTFE trough for monolayermode samplesGS19663 Aperture stops and holder for theMonolayer/Grazing Angleaccessorywww.specac.com72


<strong>Specac</strong> Product Catalogue 2011 | Specular Reflectance Accessory 30°Specular Reflectance Accessory 30°For surface analysis of solids by specular reflectanceKey Features• 30º fixed angle• Convenient horizontal sample position(20.8mm diameter full aperture)• Accommodates powder samples• Suitable for dispersiveand large beam FT-IR• Minimal alignmentApplications• Analysis of surface coatings(polymer, optical)• Local analysis of defects and inclusions• Fragile samplesSpecular Reflectance Accessory 30°Specular reflectance is a non-destructive methodfor surface measurements using a mirror-likereflection from the shiny or semi-matt surface ofa sample. Specular reflectance occurs when thereflected angle of infrared radiation equals theangle of incidence. The amount of light reflecteddepends on the angle of incidence, the refractiveindex, surface roughness and absorptionproperties of the sample.The fixed angle specular reflectance accessoryP/N GS19820 allows for a beam of radiation at afixed angle of 30 degrees incidence to fall uponthe surface of a solid material, in order to gainspectroscopic information on any surface layersof the flat solid sample. (Liquids or gums etccannot be analyzed due to the orientation of thesample).The solid sample is inverted and placed over theaperture at the top of the accessory. The incidentbeam is projected from a fixed mirror blocksurface to the sample surface and is specularlyreflected from the sample surface back to thefixed mirror block and then directed to thedetector. The sample spectral collection iscarried out after a reference spectrum has beencollected using the reference mirror (supplied) inplace of the sample. There are two differentaperture stops (5mm and 10mm diameter) thatcan be used to mask down the area of study onthe sample if desired. The sample sits flat overthe aperture and its size is necessarily limited bythe dimensions of the sample compartment andthe size of the aperture stop chosen.The accessory is installed within a spectrometerusing a Benchmark type baseplate and sowhen ordering, you need to state whichspectrometer is to be used to receive theappropriate baseplate.Ordering InformationFixed Angle Specular Reflectancefor FT-IR SpectrometersGS19820 Fixed Angle Specular Reflectancefor FT-IR SpectrometersIncludes:Optical unitReference mirrorSample aperture masks(5mm and 10mm diameter)www.specac.com73


Accessoriesfor SamplePreparationwww.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Sample Preparation - IntroductionAccessories for Sample Preparation - Introduction<strong>Specac</strong> manufactures a comprehensive range of accessories for sample preparationAccessories for Sample PreparationThis section of the catalogue is concerned withaccessories that are used for the preparation ofsamples prior to transmission or reflectancespectroscopy measurements.Classically, hydraulic presses and dies are used tomake pellet disks from a pre-ground mixture ofKBr and sample. However, the hydraulic pressescan be adapted for use in other applications.For instance, they can be used in conjunctionwith heated platens and film making systems forthe production of a wide range of solid/film typesamples.<strong>Specac</strong> produces a wide range of samplemounts from simple cards to X-Y stages.In addition, <strong>Specac</strong> offers comprehensivesampling kits that combine all the vital parts andaccessories you need to analyze virtually anysample by IR Spectroscopy.www.specac.com76


<strong>Specac</strong> Product Catalogue 2011 | Press Choice - IntroductionPress Choice - IntroductionA concise and easy to understand guide on which <strong>Specac</strong> Press to choose<strong>Specac</strong> makes a variety of hydraulic presses fora wide range of pressing applications. There isalso a range of accessories that can be usedwithin the presses themselves, for the formationand preparation of particular sample types priorto analysis by techniques such as Infrared or X-Ray spectroscopy. The <strong>Specac</strong> accessories thatcan be used within the presses are evacuablepellet dies, heated platens and film makersystems.The <strong>Specac</strong> presses themselves can becategorised as manual or automatic operatedpress systems. For manual operation thisinvolves building up the pressure on the systemand hence the load that can be applied by handpumping the press, whereas an automatic pressis the build up of pressure on the system andapplication of a load via pushing of a button.There are different versions of automatic pressesand they can be further categorised as to theirmode of operation and functionality.Each press can be specifically chosen to fulfil aparticular application dependent principally on theload range that can be applied. The load isapplied according to the operation and the waythat the load is applied is due to the functionalityof the press.Further to the functionality in respect of theAtlas Auto or Power presses, incorporated intothe pressing mechanism are compression discsprings that allow for a slow release of any loadto the sample pressing procedure.In the compression process the disc springs willbe initially compressed before full resistance ismet to stop the travel of the piston.When any stored load is released the discsprings will relax to their non-compressed stateand hence provide for a slow release of a fullload. For some samples, a slow load releasehelps to keep the sample in a compacted stateand to minimise risk of fracture.The following table categorizes our press rangePressNamePartNumberTypePressureSystem (Fluid)OperationTo Apply LoadFunctionalityTo Apply LoadLoad RangeIn TonsAtlas Manual 15T GS15011 Manual Oil (Tellus 37) Hand Pump Manual 1 to 15Atlas Manual 25T GS25011 Manual Oil (Tellus 37) Hand Pump Manual 1 to 25Atlas Power 8T GS25400 Automatic Oil (Tellus 37) Button Press Power Assisted 1 to 8Atlas Power 15T GS25430 Automatic Oil (Tellus 37) Button Press Power Assisted 2 to 15Atlas Power 25T GS25420 Automatic Oil (Tellus 37) Button Press Power Assisted 3 to 25Atlas Auto 8T GS25440 Automatic Oil (Tellus 37) Button PressAtlas Auto 15T GS25450 Automatic Oil (Tellus 37) Button PressAtlas Auto 25T GS25460 Automatic Oil (Tellus 37) Button PressAtlas Auto 40T GS25470 Automatic Oil (Tellus 37) Button PressProgrammableAutomaticProgrammableAutomaticProgrammableAutomaticProgrammableAutomatic1 to 82 to 153 to 254 to 40Press Accessories<strong>Specac</strong> presses are designed to apply aspecific load to a sample, but it is actually theaccessory itself within the press that determinesthe specific pressure applied to the sample.To give an example, if a 13mm evacuable pelletdie P/N GS03000 filled with a powder sample isplaced within a 15 ton manual hydraulic press P/NGS15011, an applied load of 10 tons (i.e. 22400lbs) is being spread over an area of 132.73 mm2(or 0.205 in2 ). This equates to a pressure of109,268 lbs per square inch or 48.78 tons persquare inch.Similarly, when a film maker accessory (P/N’sGS15640 or GS15800) is placed in a press,the load is being spread over an area of film of660.51 mm2, the films being produced having a29mm diameter. During this method of filmpreparation from a melted sample, a load of 1 to2 tons is usually sufficient to apply an appropriatepressure to the sample.www.specac.com77


<strong>Specac</strong> Product Catalogue 2011 | Atlas Manual Hydraulic Press - 15T & 25TAtlas Manual Hydraulic Press - 15T & 25TEasy to use, rugged and durable Hydraulic Presses suitable for a wide range of applicationsAtlas Manual Hydraulic Press 15T & 25TThe Atlas 15T and 25 T Manual HydraulicPresses have been designed to handle a widevariety of pressing applications. They arespecifically suited to the preparation of KBr discsusing the <strong>Specac</strong> Evacuable Pellet Die assembly.The Atlas Presses can also be used with <strong>Specac</strong>Heated Platens for applications such as thepreparation of thin polymer films.Ordering InformationKey Features• Polycarbonate safety guards• Adjustable upper bolster• Adjustable pressure control valve• Vacuum Ports• Pressure release valve• Gauges for low pressure applications (0-1,0-2, 0-5 Tons optional)GS15011 Atlas 15T Manual Hydraulic PressGS25011 Atlas 25T Manual Hydraulic PressSpares and ConsumablesGS15100 Seals and Gaskets Kit for 15 and25 Ton PressesGS15101 Hydraulic Oil for 15 and 25 TonPresses (1 litre)Options / Associated productsGS15051 Gauge Conversion Kit 0-1 TonGS15052 Gauge Conversion Kit 0-2 TonGS15055 Gauge Conversion Kit 0-5 TonSpecificationsMax height (at handle) 610mmMax width 310mmMax depth 190mmWeight 50kgLower piston stroke 25.4mmUpper bolster screw travel 89mmMinimum distance between pressing faces 38mmMaximum distance between pressing faces 152mmLower pressing face diameter 86mmUpper pressing face diameter 32mmMax width of samplingArea (side-to-side) 134mmMax Depth of SamplingArea (back-to-front) 141mmwww.specac.com78


<strong>Specac</strong> Product Catalogue 2011 | Atlas Low Tonnage Conversion KitLow Tonnage Conversion Kit for Atlas 15T Manual Hydraulic PressThe standard 0 to 15 ton manual hydraulic pressP/N GS15011 can be operated to apply up to a 15ton maximum load. On the press itself there is apressure relief valve (located under the loadgauge) which can be set to "vent off" any excesspressure in the pumping system such that amaximum load setting can be selected on thepress. This maximum load is indicated on thestandard 0 to 15 ton load gauge. Hence, if thispressure relief valve is adjusted accordingly, thenit is possible to build up a pressure thatcorresponds to e.g. a maximum of 5 tons load asindicated at the 15 ton load gauge.Any further pulls on the pump handle of the pressresults in this excess pressure being vented offat the pressure release valve. In this way it actsas a safety device to prevent overloading to asample (or die assembly) in the pressing area.The low tonnage gauge conversion kits, 0 to 1tons (P/N GS15051), 0 to 2 tons (P/NGS15052) and 0 to 5 tons (P/N GS15055)provide an additional load gauge to be usedalong with the standard 15 ton load gauge on thepress.The appropriate gauge kit is fitted by thecustomer to allow both gauges to be connectedto the press. The lower tonnage gauge can beisolated from the system but any pressure of oilin the system will always be registered at the 15ton gauge. The lower tonnage load gauge hasfiner divisions for reading of an applied load so ifit is important to know that you are applying say4.1 tons as opposed to say possibly 4.5 tons,then the 0 to 5 ton load gauge reading may berequired. But, the press itself could only beoperated up to a maximum load allowable withthe low tonnage gauge switched on line forreading. As a precaution it is recommended tohave the pressure release valve set at the lowtonnage gauge load maximum to preventpossible damage to the lower tonnage gaugeshould it accidentally not be isolated from its ownvalve tap.Therefore, in essence the 15 ton press will allowyou to apply any load up to 15 tons to a sampleor an evacuable pellet die in the pressing area.However, if a finer reading of the load applied upto a maximum of 5 tons is required, then theadditional gauge kit P/N GS15055 can be fittedto the press.The low ton gauges available for the 15 tonmanual hydraulic press and their divisions are:-0 to 1 ton gauge - gauge divisionsevery 0.05 tons load.0 to 2 ton gauge - gauge divisionsevery 0.10 tons load.0 to 5 ton gauge - gauge divisionsevery 0.20 tons load.As the gauges are analogue (needle pointers)it should be possible to read a value betweenthese divisions, hence for a 0 to 1 ton gaugeevery 0.025 tons and so on.Ordering InformationGS15051GS15052GS15055Gauge Conversion Kit 0-1 TonGauge Conversion Kit 0-2 TonGauge Conversion Kit 0-5 Tonwww.specac.com79


<strong>Specac</strong> Product Catalogue 2011 | Atlas Power Press - 8T, 15T & 25TAtlas Power Press - 8T, 15T & 25TKey Features• Microprocessor controlled pressureapplication and release• Large working distance between pressingsurfaces• Fully CE Marked• Low noise operation• Liquid crystal digital display• Multi-lingual display option• Integral high clarity PETG safety Guards• Fully compatible with <strong>Specac</strong>sample preparation accessoriesAtlas Power Press 8T, 15T & 25TThe Atlas Series Power Presses 8T, 15T & 25T,are power assisted hydraulic presses operatingto 8 Tons, 15 Tons & 25 Tons respectively. Theyhave been designed to handle a wide variety ofpressing applications, including XRF and IRsample preparation. All Presses are fullycompatible with <strong>Specac</strong> dies and other samplepreparation accessories.The presses enable the controlled applicationand release of applied load and canaccommodate large samples up to 200mm indiameter. The LCD display shows press statusand load conditions giving a digital display ofload applied.The power unit is extremely quiet and operatesbelow 62dB(A). Fitted with PETG safety guardsas standard, the Atlas Series Power Pressesare fully CE marked to comply with strictEuropean regulations.The Atlas Series Power Presses have agenerous working distance of up to 155mmbetween the pressing faces and are suitable forthe preparation of KBr discs for infrared analysisusing <strong>Specac</strong> evacuable pellet dies. They canalso be used with heated platens for applicationsincluding the preparation of thin polymer filmsubstrates.The Atlas Series Power Presses are durable,easy to use and ideal for repetitive pressingoperations at higher loads when used inconjunction with Atlas Series LightweightDies for x-ray fluorescence sample preparation.Specifications 8T 15T 25TMax. Piston Load 8 Tons 15 Tons 25 TonsDigital Display (.5 Ton steps)1-8 TonsDigital Display (.5 Ton steps) 2-15 TonsDigital Display (1 Ton steps)3-25 TonsSpecifications 8T, 15T & 25TTop Bolster Diameter32mmTop Lead Screw Vertical travel 90mmRam (Piston) Bolster Diameter 83mmRam (Piston) Stroke24mmMax/Min Pressing Faces Dist. 155mm - 40mmSample Area (Dia x Ht) 220mm Dia x 155mmBase Footprint (W x D) 425mm x 405mmHeight (without lead screw) 500mmHeight545mm - 640mmOil Type Tellus 37Oil Reservoir Capacity0.6 litresWeight95KgOrdering Information8T 15T 25TGS25400 GS25430 GS25420 UK/Europe (230v, 50Hz)GS25401 GS25431 GS25421 USA (110v, 60Hz)GS25402 GS25432 GS25422 Japan (100v, 50/60Hz)GS25403 GS25433 GS25423 China (230v, 50Hz)GS25404 GS25434 GS25424 Korea (230v, 60Hz)Atlas Series DiesMax. LoadGS25410 Lightweight 32mm Die 25 TonsGS25411 Lightweight 40mm Die 25 TonsELECTRICwww.specac.com80


<strong>Specac</strong> Product Catalogue 2011 | Atlas Auto Press - 8T, 15T, 25T & 40TAtlas Auto Press - 8T, 15T, 25T & 40TKey Features• Programmable microprocessor controlledpressure application and release• Simple user operation procedures viasymbols and prompts• Maintain load applied from automatic“top up”• Graphics display with LED backlight control• End of cycle alarm or indication• Integral high clarity PETG safety guards• Fully CE marked• Fully compatible with <strong>Specac</strong>sample preparation accessoriesAtlas Auto Press - 8T, 15T, 25T & 40TThe Atlas Auto Presses 8T, 15T, 25T & 40T areprogrammable, microprocessor controlled,power assisted hydraulic presses, operating to8 Tons, 15 Tons, 25 Tons and 40 Tonsrespectively. They have been designed for awide variety of pressing applications includingXRF and IR sample preparation. All presses arefully compatible with <strong>Specac</strong> dies and othersample preparation accessories.The Presses enable the controlled applicationand release of an applied load, accommodatingsamples up to 200mm in diameter. The appliedload can be maintained indefinitely, or to aspecific time via user programmablefunctionality.The graphic display shows the press programstatus and load conditions providing a digitaldisplay of load applied, together with an end ofcycle alarm/indicator.The power unit is extremely quiet and operatesbelow 62dB.Fitted with PETG safety guards as standard theAtlas Auto Presses are fully CE marked tocomply with strict European regulations.The Atlas Auto Presses have a generousworking distance of up to 155mm between thepressing faces and are suitable for thepreparation of KBr discs for infrared analysisusing <strong>Specac</strong> evacuable pellet dies. They canalso be used with the Atlas Heated Platens forapplications including the preparation of thepolymer film substrates.The Atlas Auto Presses are simple to use andprogram via the use of screen symbols andprompts. Options include user selectablelanguages and load units. The Presses durabilityare ideal for applications such as X-rayfluorescence sample preparation using Atlas Series Lightweight Dies.www.specac.com81


<strong>Specac</strong> Product Catalogue 2011 | Atlas Auto Press - 8T, 15T, 25T & 40TAtlas Auto Press - 8T, 15T, 25T & 40TSpecificationsMax. Piston Load8T 15T 25T 40T8 Tons 15 Tons 25 Tons 40 Tons8T Digital Display (.2 Ton Steps) 1-8 Tons15T Digital Display (.2 Ton Steps) 2-15 Tons25T Digital Display (.5 Ton Steps) 3-25 Tons40T Digital Display (.5 Ton Steps) 4-40 TonsOrdering Information8TGS25440GS25441GS25442GS25443GS2544415TGS25450GS25451GS25452GS25453GS2545425TGS25460GS25461GS25462GS25463GS2546440TGS25470GS25471GS25472GS25473GS25474UK/Europe (230v, 50Hz)USA (110v, 60Hz)Japan (100v, 50/60Hz)China (230v, 50Hz)Korea (230v, 60Hz)UK/Europe (230v, 50Hz)USA (110v, 60Hz)Japan (100v, 50/60Hz)China (230v, 50Hz)Korea (230v, 60Hz)UK/Europe (230v, 50Hz)USA (110v, 60Hz)Japan (100v, 50/60Hz)China (230v, 50Hz)Korea (230v, 60Hz)UK/Europe (230v, 50Hz)USA (110v, 60Hz)Japan (100v, 50/60Hz)China (230v, 50Hz)Korea (230v, 60Hz)Specifications 8T, 15T, 25T & 40TTop Bolster Diameter32mmTop Lead Screw Vertical travel 90mmTop Lead Screw Vertical travel 80mm (40T)Ram (Piston) Bolster Diameter 82mmRam (Piston) Stroke24mmRam (Piston) Stroke38mm (40T)Max/Min Pressing Faces Dist. 155mm - 40mmMax/Min Pressing Faces Dist. 140mm - 60mm (40T)Sample Area (Dia. x Hgt) 220mm x 155mmSample Area (Dia. x Hgt) 240mm x 220mm (40T)Base Footprint (W x D) 425mm x 405mmBase Footprint (W x D) 430mm x 405mm (40T)Height (without lead screw) 500mmHeight (without lead screw) 550mm (40T)Height (Lead Screw At Min. & Max. DistancesBetween Pressing Faces) 545mm - 640mmHeight (Lead Screw At Min. & Max. DistancesBetween Pressing Faces) 580mm - 660mm (40T)Oil Type Tellus 37Oil Reservoir Capacity 0.6 litres & 1litre (40T)Weight95Kg & 130Kg (40T)Communication TypeUSBDisplay UnitsTons, Tonnes, US TonsHold Times0.1 to 99 minutes and infinityOptimised Release Rates Fast, Medium, SlowStored Programs 6Maximum Program Segments 10ELECTRICAtlas Series DiesMax. LoadGS25410 Lightweight 32mm Die 25 TonsGS25411 Lightweight 40mm Die 25 Tonswww.specac.com82


<strong>Specac</strong> Product Catalogue 2011 | Evacuable Pellet DiesEvacuable Pellet DiesProduction of high quality sample pellets from 5mm to 40mm diameterKey Features• Hardened Stainless Steel• Highly polished pellets• Evacuable for sample pellet clarity andquality• Vacuum pump kit for moisture freepressing (optional)Evacuable Pellet DiesEvacuable Pellet Dies will fit into any of the<strong>Specac</strong> presses. However, it is usual that a largerdiameter size of evacuable pellet die requires ahigher load to be applied by a press forcompaction of the sample. The dies themselvesare rated to a particular tonnage load maximumand so when certain combinations of a die sizeare used in a particular press, care must beobserved that the maximum tonnage load for thedie is not exceeded.The range of Evacuable Pellet Dies supplied asstandard are:-GS03060 5mm evacuable pellet die(Max load 2.0 Tons)GS03100 10mm evacuable pellet die(Max load 5.0 Tons)GS03000 13mm evacuable pellet die(Max load 10.0 Tons)GS03165 20mm evacuable pellet die(Max load 25.0 Tons)GS03300 32mm evacuable pellet die(Max load 50.0 Tons)GS03290 40mm evacuable pellet die(Max load 85.0 Tons)These dies are made from 440c hardenedstainless steel and all of the dies are equippedwith nitrile o-ring seals and an evacuation portfor removal of moisture if desired during thepressing processVACUUMwww.specac.com83


<strong>Specac</strong> Product Catalogue 2011 | Evacuable Pellet DiesEvacuable Pellet Dies Ordering InformationSpecificationsA+B = Plunger HeightC = Stainless Steel Pellet Height(only 1 pellet in 3mm die).D = Base HeightE = DiameterA+B+C+D = Total Height of DieDie Size 5mm 10mm 13mm 20mm 32mm 40mmP/N GS03060 GS03100 GS03000 GS03165 GS03300 GS03290A 13.7 16 16.0 21.4 21.4 21.4B 38.8 19.1 19.1 35.8 35.8 35.8C 12.7 12.7 12.7 19.1 19.1 19.1D 22.2 22.7 22.2 27.8 27.8 27.8E 50.8 50.8 50.8 68.3 68.3 95.3Evacuable Pellet Dies Complete OptionsSize (dia) Die Pellet Holder5mm GS3060 GS340010mm GS3100 GS340413mm GS3000 GS341020mm GS3165 GS3193*32mm GS3300 GS3520*40mm GS3290 GS3298**These pellet holders are sample retaining ringsonly and do not have a rectangular mounting plate.Die SparesSpares and ConsumablesGS3600 Agate Pestle and Mortar(Mortar Bowl dia. 4cm)GS3610 KBr powder (50g)GS3460 Paper rings for 13mm die(11mm diameter aperture) (100)GS3470 Micro frames for 13mm die(11mm x 2mm aperture) (100)GS3475 Ultra Micro frames for 13mmdie (4 x 1mm aperture) (100)DiameterSet ofPelletsPlunger Body BaseExtractorRingO Ring Kit5mm GS03061 GS03063 GS03064 GS03050 GS03069 GS0306210mm GS03101 GS03103 GS03104 GS03050 GS03025 GS0310213mm GS03010 GS03030 GS03040 GS03050 GS03025 GS0302020mm GS03166 GS03168 GS03169 GS03191 GS03521 GS0316732mm GS03310 GS03330 GS03340 GS03230 GS03521 GS0332040mm GS03291 GS03293 GS03294 GS03295 GS03297 GS0329284www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Atlas Lightweight DiesAtlas Lightweight DiesOrdering InformationGS25410GS25411GS25412GS25413GS25414GS25415GS25416GS25417GS25418GS25419Atlas 32mm LightweightEvacuable Pellet DieAtlas 40mm LightweightEvacuable Pellet DieAtlas 32mm EvacuablePellet Die BodyAtlas 32mm EvacuablePellet Die PlungerAtlas 32mm EvacuablePellet Die BaseAtlas 32mm EvacuablePellet Die O-Ring KitAtlas 40mm EvacuablePellet Die BodyAtlas 40mm EvacuablePellet Die PlungerAtlas 40mm EvacuablePellet Die BaseAtlas 40mm EvacuablePellet Die O-Ring KitAtlas Lightweight DiesThe Atlas Lightweight Evacuable Pellet Dieshave been specifically designed to work with therange of Atlas automatic presses up to amaximum load rating of 25 tons. The dies arealso compatible for use with <strong>Specac</strong>’s 15 and 25ton manual hydraulic presses.The dies are made of 440C stainless steel andoffered to prepare pellet discs of 32mm (P/NGS25410) or 40mm (P/N GS25411) diametersize.They are well suited for the preparation of solidpellets for study by X-Ray Fluorescencespectroscopy. When many samples are to beprepared for study, the physical effort required toload and remove an Atlas LightweightEvacuable Pellet Die into a press is greatlyreduced, as the dies themselves are physicallysmaller and lighter in weight by comparison toconventional 32mm and 40mm diameter pelletdies. The 32mm die P/N GS25410 isapproximately 1.8Kgs and the 40mm die P/NGS25411 is approximately 1.9kgs in weight. Bycomparison the 40mm pellet die P/N GS03290is close to 5.0kgs in weight.To aid in the weight reduction there are noindividual internal pressing pellets as withconventional dies and so a sample iscompressed between the plunger and the basepiece of the die assembly. For this reason theplunger itself has a highly polished surface thatmakes contact with the sample. The highlypolished face helps in producing an even surfaceto the sample pellet and in release of the samplefrom the die components.The Atlas Lightweight Evacuable Pellet Dieshave an evacuation port and can be operatedusing a partial vacuum for the compression ofsamples into pellets that may be moisturesensitive.VACUUMwww.specac.com85


<strong>Specac</strong> Product Catalogue 2011 | Specadie Specadie Produces KBr pellets without using a pressSpecadie The Specadie accessory allows for theproduction of a solid KBr pellet for analysis byInfra Red spectroscopy without the need of aseparate press and die.The Specadie consists of a die body and twobolts that each have a highly polished pressingface. In operation a ground KBr powder is placedin the die body and compressed between thetwo bolts that are tightened together. A KBrpellet of 8.5mm diameter is formed. The bolts arethen removed and the compressed KBr powderis retained inside the die body. The die body inturn acts as the pellet holder and is placed into aspectrometer via the Specadie holder 3” x 2”mount plate P/N GS03560Ordering InformationKey Features• No press or pellet holder required• Rapid sample preparation• Evacuable for sample clarity and qualityApplications• Halide pellets for IR analysisSpecadie GS03550Specadie with bolts andseals onlySpecadie KitGS03700 Includes: Specadie Specadie HolderBench mounted wrench (spanner)Open ended wrench (spanner)Spare set of boltsSpare set of sealsBottle of KBr powder (50g)Spares and consumablesGS03560 Circular Specadie HolderGS03570 Set of boltsGS03590 Set of two open ended wrenches(spanners), 9/16” (14.3mm) and1/2” (12.7mm) AFGS03595 Bench mounted wrench (spanner)GS03580 Set of sealsGS03610 KBr powder (50g)VACUUMwww.specac.com86


<strong>Specac</strong> Product Catalogue 2011 | Vacuum Pump SystemVacuum Pump SystemVacuum Pump System for Evacuable DiesVacuum Pump SystemThe vacuum pump P/N GS03640 is a dualvoltage operation (220 volts and 110 volts), twostage vacuum pump capable of pulling a vacuumto 0.05 Torr or better. It is an ideal vacuum pumpto use with the <strong>Specac</strong> Accessories that have thecapability of being operated under these vacuumconditions.It is designed for normal starting in lowtemperature and low voltage conditions.(Typically temperatures at or above 5°C with a +/-10% rated voltage.An air passage prevents any pump oil fromreturning into the pipeline or vacuum vesselbeing pumped after the vacuum pump isstopped.There is an inbuilt oil mist eliminating device and ithas an oil/gas separator at the air exhaust outletwhich removes any oil contamination in the airexhaust.The pump operates at a high ultimate vacuumwith low noise.Each vacuum pump has been factory tested forits vacuum pump speed in both CFM andmicron units.The vacuum pump GS03640 is supplied alongwith an appropriate kit of parts (a pressuregauge, vacuum tubing and particular connectingunions) compatible for immediate use with theappropriate <strong>Specac</strong> accessories.SpecificationsNo of stages: 2Free Air Displacement: 85 litres/min at 220 voltsoperation.Ultimate vacuum: 15 microns.Pump motor: 0.25 HP.Pump speed: 2880 RPM (220Volts), 3440 RPM(110Volts).Electrical connectivity: 220Volts/50Hz,110Volts/60Hz.Oil capacity: 400mls.Maximum operating temperature capability:80°C.Minimum operating temperature capability: 1°C.Overall width (side to side dimension): 150mm.Overall length (front to back dimension): 350mm.Overall height (to top of handle): 250mm.Ordering InformationVacuum Pump SystemGS03640 Vacuum Pump KitFor producing clear, moisture freesample pellets with the EvacuablePellet Dies.Includes: Vacuum Pump(1x10-1 mbar), gauge& connector tube.Please state 220V or 110V and countryGS03643VACUUMVacuum Pump Oil (1 litre)www.specac.com87


<strong>Specac</strong> Product Catalogue 2011 | Atlas Heated PlatensAtlas Heated PlatensA quick and simple accessory for converting standard Hydraulic Presses to heatable versionsAtlas Heated PlatensThe Atlas Heated Platens have been designedto provide heatable pressing surfaces compatiblewith all <strong>Specac</strong> Hydraulic Presses. The platensare easily installed by replacing the bolster fixingof the press by the top platen and placing thebottom platen over the lower pressing face ofthe press.The platens have a large surface area, arerugged, durable and have full CE safety approval.They are fitted with a permanent thermocouplewhich monitors the temperature close to thepressing surface. The press connection ports arewater cooled which allows for an efficient heatingand cooling cycle.The platens are controlled by a digital automatictemperature controller with a stability of ± 1ºCKey Features• Digital temperature display• Controlled temperature to 300ºC withwater cooling• 15 Ton load bearing capacity• CE Safety Approved• 100mm diameter pressing surface• Compatible with all <strong>Specac</strong> HydraulicPressesOrdering InformationGS15515 Atlas Water Cooled HeatedPlatens and AutomaticTemperature Controller withDigital Display.Includes 2 metres of 6mm id.PVC tubing and flow connectors.Specify 220V or 110V and country of usageSpares and ConsumablesGS15601 PTFE sheets 0.25mm thick forWater Cooled Heated Platens (10)GS15512 Replacement heater set forPlatens (220V)GS15522 Replacement heater set forPlatens (110V)ELECTRICWATER 12 ltrwww.specac.com88


<strong>Specac</strong> Product Catalogue 2011 | Atlas Constant Thickness and High Temp. Film-MakerAtlas Constant Thickness and High Temp. Film-MakerFilm making systems to produce high quality, reproducible polymer filmsP/N GS15640P/N GS15800Key Features - GS15800• Up to 400ºC operation• 10 minute cycle time• CE Safety Approved• Integral heating and cooling• 2 Ton load limit• 0.015, 0.025, 0.050, 0.100, 0.250,0.500mm films of 29mm diameter• Easy film releaseKey Features - GS15640• Up to 300ºC operation• 15 minute cycle time• 4 Ton load limit• 0.015, 0.025, 0.050, 0.100,0.250,0.500mm films of 29mm diameter• Easy film release• Operates with Heated Platens P/N 15515Atlas Constant Thickness Film-Maker<strong>Specac</strong> make two types of film maker accessorythat are ideal for the preparation of thin films frompolymers materials. The films produced are29mm in diameter and can vary in thickness dueto use of a set spacing ring. Individual spacingrings are supplied for a nominal thickness of filmat 0.015, 0.025, 0.05, 0.100, 0.250 and 0.500millimeters. The principal difference between thetwo film maker accessories is the maximumoperating temperature allowable by each one.The Constant Thickness Film Maker AccessoryP/N GS15640 is designed to be used with theAtlas Heated Platens P/N GS15515 within a 15ton Manual Hydraulic Press P/N GS15011.However, the 25 Ton Manual Hydraulic Press P/NGS25011, the Atlas Power T8 Press P/NGS25400 and Atlas Auto T8 Press P/NGS25440 can also be used with the AtlasHeated Platens P/N 15515 and Film MakerAccessory P/N GS15640.The Atlas Heated Platens provide thetemperatures necessary to melt a sample withinthe film maker accessory prior to compressionvia the press. The maximum temperatureprovided by the Atlas Heated Platens is 300°C,so any materials that have a melting point higherthan this are not suitable for forming into thinfilms using the Atlas Constant Thickness FilmMaker P/N GS15640. The specified maximumload limit for this accessory within the press is 4tons when indicated at the load gauge on theManual Hydraulic Presses and digital display onthe Atlas Power and Auto Presses. Typically a 1ton load gives acceptable results for film thickness.Atlas High Temperature Film-MakerThe High Temperature Film Maker Accessory P/NGS15800 has a set of heated platens alreadyincorporated into the film making part of theaccessory and so the Atlas Heated Platens P/NGS15515 are not needed for use when P/NGS15800 is installed in a press. (The HighTemperature Film Maker Accessory P/NGS15800 will fit into the same presses for useas the combination of P/N’s GS15515 andGS15640.)The heated surfaces of P/N GS15800 areoperable up to 400°C, so it is possible to makethin films of samples with melting points up to thistemperature in this film maker accessory. Themaximum load limit for this accessory is 2 tonswhen indicated at the load gauge on the ManualHydraulic Presses and digital display on the AtlasPower and Auto Presses, but similar to thewww.specac.com89


<strong>Specac</strong> Product Catalogue 2011 | Atlas Constant Thickness Film-Maker Ordering InformationAtlas Constant Thickness Film-MakerFilm making systems to produce high quality, reproducible polymer filmsconstant thickness film maker, acceptableresults for film thickness is typically achieved at a1 ton load.For samples that require at least a 300°Ctemperature to melt, the High Temperature FilmMaker Kit P/N GS15800 must be used. However,the combination of separate items as offered bythe Atlas Constant Thickness Film Maker P/NGS15640 and the Atlas Heated Platens P/NGS15515 means that there can be moreflexibility in use of these accessories. A presswith the Atlas Heated Platens can be usedwithout the need of the Atlas ConstantThickness Film Maker Accessory, if a heatedpressing surface is required for other purposes.The Atlas Heated Platens themselves can beused up to a maximum 15 ton applied load asindicated by the load gauge on the ManualPresses and to 8 tons applied load on the digitaldisplays of the Atlas Power and Auto T8 Presses.Included in the Atlas Constant Thickness FilmMaker Accessory P/N GS15640 is a separatecooling chamber block. This cooling chamber isincorporated as part of the water cooling systemrequired for operation of the Atlas HeatedPlatens P/N GS15515. Use of the coolingchamber block can help in the speed of filmpreparation, because when the sample has beenmelted and compressed within the film makingplaten assembly (between the heated platens inthe press), the film making platen assembly canbe transferred from the press into the coolingchamber block. The time of transfer would bepart of the overall sample preparation regimeadopted, but typically could be at a temperature50°C lower than the temperature used formelting and compression of the sample. If thesample has melted and been compressed at200°C, when transferred to the cooling block at150°C, it will cool faster to ambient temperaturewhereby the film can be handled, rather thanwaiting for the Atlas Heated Platens to get coolenough to touch. If there is an additional filmmaker platen assembly available, this could nowbe placed into the Atlas Heated Platens and thenext film could be in preparation whilst the otheris cooling. This is a possible method of thin filmproduction that can only be achieved with theConstant Thickness Film Maker P/N GS15640due to its specific design.In summary, the Atlas High Temperature FilmMaker Accessory P/N GS15800 must be usedfor samples that melt between 300°C and 400°C.Either Film Maker Accessory can be used withsamples that melt up to 300°C, but there isgreater potential flexibility for use of a Press withAtlas Heated Platens that are needed with theAtlas Constant Thickness Film MakerP/N GS15640.Ordering InformationFilm Maker SystemsGS15640 Atlas Constant ThicknessFilm MakerIncludes: 0.015,0.025,0.050,0.100,0.250 and 0.500 mm spacer ringsAluminium foil discs 40mmdiameter (200)<strong>Specac</strong>ards 10mm diameter clearaperture (20)Stainless steel forcepsGS15800 Atlas High TemperatureConstant Thickness Film MakerIncludes: 0.015,0.025,0.050,0.100,0.250 and 0.500 mm spacer ringsAluminum disc foils 40mmdiameter (200)Tool for making aluminum foilsample cup<strong>Specac</strong>ards 10mm diameter clearaperture (20)Stainless steel forcepsHigh stability digital temperaturecontroller (400˚C)Non-drip water connectors(Specify 220V or 110V and country of usage)Constant Thickness Film Maker KitsGS15631 Atlas Constant Thickness FilmMaker Kit IIncludes: Constant Thickness FilmMaker System (GS15640)Heated Platens and DigitalAutomatic Temperature Controller(300˚C) (15515)(Specify 220V or 110V and country of usage)GS15633 Atlas Constant Thickness FilmMaker Kit IIIncludes: Constant Thickness FilmMaker System (GS15640)Heated Platens and DigitalController (3000C) (GS15515)15 Ton Manual Hydraulic Press(GS15011)(Specify 220V or 110V and country of usage)Ordering information cont’dwww.specac.com90


<strong>Specac</strong> Product Catalogue 2011 | Atlas High Temperature Film-Maker Ordering InformationAtlas High Temperature Constant Thickness Film-MakerFilm making systems to produce high quality, reproducible polymer filmsOrdering Information cont’dAtlas High Temperature Constant ThicknessFilm-Maker KitGS15810 Atlas High Temperature ConstantThickness Film Maker KitIncludes: High TemperatureConstant Thickness Film MakerSystem (GS15800)15 Ton Manual Hydraulic Press(GS15011)(Specify 220V or 110V and country of usage)ELECTRICWATER 5 ltrSpares and ConsumablesGS03800 10mm diameter aperture<strong>Specac</strong>ards (100)GS03805 PTFE retaining rings forsupporting elastic filmsamples (20)GS03810 10mm x 25mm aperture<strong>Specac</strong>ards (100)GS03820 Magnetic film holderGS15627 40mm diameter aluminum foildiscs (200)GS15641 Constant Thickness Film MakerReplacement Cooling Block AssyGS15642 Constant Thickness Film MakerReplacement Platen AssyGS15629 Constant Thickness Film MakerReplacement Spacer Ring SetGS15805 High Temperature Film MakerReplacement Spacer Ring Setwww.specac.com91


<strong>Specac</strong> Product Catalogue 2011 | Specamill 92Specamill Provides efficient grinding and blending of solid materialsKey Features• Rapid grinding• Choice of capsule and sphere materials• Adjustable vibration• Timer with manual overrideApplications• Grinding and blending a wide variety ofmaterials• Sample preparation for KBr pellets• Sample preparation for diffuse reflectancespectroscopySpares and ConsumablesGS06300 Agate spheres for Specamill (3)GS06400GS06500GS06600GS06700Stainless steel spheresfor Specamill (3)Replacement Bladefor Specamill Replacement Clip for Specamill Spare Capsule Holderfor Specamill Specamill The Specamill grinding accessory is designed tomix a solid sample with an excess of KBr powderfor the preparation of powder samples prior tocompression into KBr pellets for IR study. It canalso be used in preparing samples for diffusereflectance spectroscopy. The target particle sizeof the sample is at least 0.025mm (if not smaller)to coincide with the wavelength of light in theclassical Mid IR region. Final particle size willdepend specifically on the actual sample and themixture proportions and the amount of timebeing applied for the grinding process.There are two capsule sets that can be usedwithin the Specamill grinding accessory P/NGS06000. One capsule set P/N GS06200 is anagate capsule set and the other P/N 6100 is astainless steel capsule set. Each set consists of acapsule body, stopper and three grinding ballsfabricated in the agate or stainless steel.The reason for use of either set is principally dueto the difference in hardness of material. Agate,being a naturally occurring mineral is typicallybetween 6 and 7 on the Mohs scale of hardness.Steel, depending on its fabrication and chemicalmake up, can vary from between 5 to 8.5 on thesame Mohs scale of hardness. The <strong>Specac</strong>stainless steel capsule set is typically of a Mohshardness of 7.5.The capacity of each capsule is 3ml and therecommended filling volume is 30% (excludingspheres).Ordering InformationSpecamill GS06000 Specamill (220V, 50Hz) UKGS06001 Specamill (220V, 50Hz) EUGS06800 Specamill (110V, 60Hz) USThe Specamill requires a capsule setCapsule SetsGS06100 Stainless steel capsulefor Specamill Includes Stainless steel stopperStainless steel spheres (3)GS06200 Agate capsule for Specamill Includes Agate stopperAgate spheres (3)ELECTRICwww.specac.com


<strong>Specac</strong> Product Catalogue 2011 | <strong>Specac</strong>abinet <strong>Specac</strong>abinet <strong>Specac</strong>abinet Allows storage of hygroscopic infrared materials under controlled conditionsKey Features• Thermostatically controlled up to 80ºC(stability ±0.5ºC)• Sliding doors• Size (L x W x H): Internal: 737x331x432mmExternal: 762x356x508mm• Can be wall mountedThe <strong>Specac</strong>abinet is a drying cabinet suitablefor the storage of hygroscopic materials (such asIR cell windows or reference samples) and anyother accessories that require a moisture freestorage environment.The <strong>Specac</strong>abinet is thermostatically controlledover the temperature range from ambient to80°C.A drying agent is included with a colour indicatorallowing for a constant check on the humidity.Ordering InformationGS19100GS19102<strong>Specac</strong>abinet (220V, 50Hz) UK<strong>Specac</strong>abinet (220V, 50Hz) EUELECTRICwww.specac.com93


<strong>Specac</strong> Product Catalogue 2011 | <strong>Specac</strong>ards & Magnetic Film Holder<strong>Specac</strong>ards & Magnetic Film HolderFilm making systems to produce high quality, reproducible polymer filmsP/N GS03800 P/N GS03810 P/N GS03820Key Features• Self sealing adhesive coating (<strong>Specac</strong>ard)• Magnetic ring (Film Holder)• Indexing space (<strong>Specac</strong>ard)• Clear aperture:10mm diameter or 25 x 10mm (<strong>Specac</strong>ard)25mm diameter (Magnetic Film Holder)Ordering InformationFilm Maker SystemsGS03800 <strong>Specac</strong>ards 10mm diameteraperture (100)GS03810 <strong>Specac</strong>ards 25 x 10mmaperture (100)GS03820 Magnetic Film Holder• 3” x 2” Slide mountedwww.specac.com94


<strong>Specac</strong> Product Catalogue 2011 | FT-IR Starter KitFT-IR Starter KitProvides a cost-effective package for routine transmission analysis of solids, liquids and gasesContents• Omni Liquid Cell• Omni Mull Cell• 10cm Gas CellFT-IR Starter KitThe FT-IR Starter Kit is the perfect combinationof transmission accessories, for use with solids,liquids and gases. The items are packaged in ahard shell carrying case for storage andtransportation.• Film holder• Specadie• Carrying caseOrdering InformationFT-IR Starter KitGS01135 FT-IR Starter KitKit Includes the following:GS01110 Luer syringeGS01800 Omni Cell assembly (2)GS01811 Pair of KBr windows forOmni Liquid CellGS01812 Pair of CaF2 windows forOmni Liquid CellGS01831 Pair of KBr windows forOmni Mull CellGS01851 PTFE spacers 0.1mm forOmni Liquid Cell (5)GS01864 Assorted PTFE spacers forOmni Liquid Cell (10)GS01871GS02303GS03600GS03610GS03620GS03700GS03820GS05000GS05030PTFE spacers 0.1mm forOmni Mull Cell (5)MicrospatulaAgate pestle and mortarBottle of KBr powder (50g)Bottle of Nujol (25ml)Specadie disc pressing kitMagnetic film holderSeries 10cm Pyrex gas cell withKBr windows (P/N 5021)Circular cell mount forPyrex gas cell (slide mounted)www.specac.com95


<strong>Specac</strong> Product Catalogue 2011 | Professional Starter KitProfessional Starter KitThe cost-effective way to obtain reflectance sampling versatilityP/N GS11165 P/N GS04510 P/N GS19820Contents• Benchmark ATR for liquids, semisolidsand films• Minidiff Plus for solids and polymers• Fixed Angle Specular ReflectanceAccessory for solids and polymersProfessional Starter KitThe Professional Starter Kit offers an economicpackage of three high performance accessoriesgiving coverage of the most popular techniquesin reflectance sampling.The kit consists of Attenuated Total Reflectance(ATR), Diffuse Reflectance (DRIFT) and SpecularReflectance units. Also included in the kit are allancillary consumables such as KBr powder,spatula, pestle and mortar and Diabrase abrasivepads necessary to tackle most samples in theinfrared spectroscopy laboratory.All of the accessories are compatible with thestandard Benchmark baseplate mounting andtherefore can be quickly and easily interchanged.The units in the Professional Starter Kit requireminimal alignment thereby reducing operatorlearning and set-up time.Ordering InformationProfessional Starter KitGS04540 Professional Starter Kit(Please specify spectrometer make and model)Includes:Benchmark Gateway ATR Unit(GS11165)Fixed Angle 30º SpecularReflectance Unit (GS19820)Reference mirrorSample aperture masks(5mm and 10mm diameter)Minidiff Plus Diffuse ReflectanceAccessory (GS04510)Sample cup holders (2)Abrasive sample holders (2)Diabrase abrasive pads (20)Pestle and MortarSpatulaKBr powder (50g)Spares and ConsumablesPlease see under individualsections in the catalogueFor Benchmark ATR - Page 57For Minidiff Plus - Page 62For Fixed Angle - Page 65www.specac.com96


<strong>Specac</strong>ProcessCapabilitieswww.specac.com


<strong>Specac</strong> Product Catalogue 2011 | <strong>Specac</strong> Process Capabilities<strong>Specac</strong> Process CapabilitiesA proven track record of reliability and robustness in the most demanding industrial environments.ProCell Process Flow Cells<strong>Specac</strong> have over 15 years of process applicationexperience. Our ProCell process flow cells aredesigned to withstand the rigors of process andenvironmental conditions while maintainingcontinuous measurement stability and have aproven track record of reliability and robustnessin the most demanding industrial environments.• Process cells are a key enabling technologyto facilitate the acquisition of continuous onlineUV/Vis and NIR spectroscopic absorbanceprocess measurementsProcess flow cells are typically installed as part ofthe process circuit either directly in the processstream or as a “by-pass loop”.• By adopting the process flow cell in a “by-passloop” configuration, the user has the opportunityto isolate the process flow cell from the processcell for routine cleaning, servicing, or calibration.Computer-aided optical design ensures that<strong>Specac</strong>’s process flow cells have the highestlevels of optical throughput to ensure the bestquality of spectroscopic data.<strong>Specac</strong> process cells are customized to ensureexact matching with the client’s processrequirements.• Material metallurgies, seal types, and windowmaterials are chosen to be compatible with thechemical and environmental needs of theapplication. This often goes beyond standardoperating conditions, and includes aggressivecleaning regimes and extreme weatherconditions.• Optical designs are configured for the UV/Visor NIR spectral regions as appropriate, andoptical pathlengths are set to ensure optimumspectral absorbance of the target chemicalspecies.• A range of pipe fittings and flange connectionsare available to interface the process flow cellwith the process pipe work.• Cleaning ports and seal leak warning ports canalso be integrated into the cell design.www.specac.com98


<strong>Specac</strong> Product Catalogue 2011 | Process CapabilitiesProCell CascadeLiquid Phase Process Flow CellProCell CascadeThe <strong>Specac</strong> ProCell Cascade liquid phaseprocess cell is a rugged transmission mode cellideally suited for optical sampling of industrialfluids. The ProCell Cascade series is designedto be pipe-mounted into the sample analysis partof the process steam or in a by-pass.Key Features• Optical transmission pathlengths areavailable from 1.0 to 10 mm to optimiseUV/Vis or NIR spectroscopic absorptionfeatures for analysis.• Capability for high temperatureapplications (up to 400°C)• Can be configured for a wide range ofANSI and DIN flange sizes• Cleaning port option for in-situ servicingProCell VortexLiquid Phase Process Flow CellProCell VortexThe <strong>Specac</strong> ProCell Vortex liquid phase processcell is an extremely robust cell that deliversoptimum sensitivity to process characteristicsThe ProCell Vortex series is designed to beflange mounted directly into the process streamor in a by-passKey Features• Optical transmission pathlengths areavailable from 1.0 to 10 mm to optimiseUV/Vis or NIR spectroscopic absorptionfeatures for analysis.• Capability for high temperatureapplications (up to 400°C)• Can be configured for a wide range ofANSI and DIN flange sizes• Cleaning port option for in-situ servicing99www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Process CapabilitiesProCell TyphoonGas/Vapour Phase Process Flow CellProCell TyphoonThe <strong>Specac</strong> ProCell Typhoon is a ruggedpipe-mounted spectroscopic transmission cell forgas phase process monitoring in the UV/Vis orNIR region. The ProCell Typhoon is typicallyfitted into the process stream or in a by-passusing Swagelok connectors.Sapphire windows give outstanding abrasion andchemical resistance, in addition to the ability towithstand severe thermal shock (e.g. highpressure steam cleaning).Key Features• To ensure optimum UV/Vis or NIRspectroscopic absorption features forpathlengths are available at 20cm, 30cm,or 50cm.• Cleaning ports allow the internal cellwindows to be cleaned without removingthe cell from the pipe work in the event offouling (either from long term use orfollowing a process upset)• Optical fibre connectivity is ensured byindustry standard SMA 905 connectors• anti-extrusion seal design to give highpressure capability and long-term reliability100www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Process CapabilitiesMini ProbeLiquid Phase Process Flow CellMini ProbeThe <strong>Specac</strong> Mini Probe is a high performanceprobe that allows remote process monitoring andcontrol. The Mini Probe can be specified in arange of materials and sizes.Key FeaturesMini Probe Close Up• Designed for operation in the NIR spectralregion with optical pathlengths in therange of 1 to 10mm• Sapphire windows sealed by means ofa Gold / Nickel diffusion bond ensureexcellent chemical and mechanicalresistance• Body material can be selected to suitapplication with Stainless Steel 316L orHastelloy C276 commonly used• Probe Length (immersion length) in therange of 100 to 500mm• Capable for operation at temperatures upto 250˚C and at pressures from vacuumup to 1500 psi.• Compatibility to the user’s instrument isensured with a choice of fibre connectortypes (SMA and FC) as well as fibre type(single or multimode)• The wide choice of probe lengths allowsthe probes to be mounted in a range oflocations without excessive probe bodyprotrusion from the vessel or pipe• The Mini Probe can be supplied with anarmoured fibre optic cable which ensuresthat any stresses from the weight of thecable are not transmitted to the opticalfibre connection interface.www.specac.com101


<strong>Specac</strong> Product Catalogue 2011 | Spectroscopist’s Hints and TipsSpectroscopist’s Hints and TipsThe following hints and tips on Infrared Sampling may help you achieve better spectra withgreater ease. Don’t forget to contact your local <strong>Specac</strong> representative if you need any helpwith your application. Contact details are listed at the back of this catalogue.Sample PreparationFor the preparation of halide disks,pestles,mortars and KBr powder should be stored in adry environment such as the <strong>Specac</strong>abinet.The equipment should be used while still warm tominimize water contamination of the disk.A good approximation for “first time right” halidedisks is to choose a weight-to-weight ratio of 1%sample to 99% KBr. This approximation is goodfor most organic materials.Don’t take shortcuts by insufficient grinding ofhalide disk constituents. The target particle size is0.025 mm, to coincide with the wavelength oflight in the classical mid-infrared region.Fold a sheet of paper in half to make a simplefunnel for swift and easy transfer of the grounduphalide disk constituents into the pellet dies.Take the time to use a vacuum pump withevacuable pellet dies when producing halidedisks. The resulting higher quality disks produceimproved spectra.If a finished halide disk absorbs too strongly,there is no need to start again completely.Simply break off a small piece and regrind withadditional KBr.If so, use the one window only for improvedspectral quality. Always run background data forboth one and two windows in anticipation of this.When using liquid transmission cells in quantitativemeasurements it is useful to check thepathlength before and after an experiment. Thisis especially helpful with demountable cells.Try using two syringes, one in each cell port,when filling and emptying liquid transmissioncells. This helps to prevent air bubbles in theliquid film, and is especially useful when usingvery thin spacers.Whilst doing a series of concentration solutions itis advisable to change the sample via the fillingports rather than dismantling the cell.Concentration contamination effects are avoidedin quantitative work by analyzing the sample setin increasing order of concentration.Typical transmission pathlengths for organicsolvent based solutions are as follows:AnalyticalConcentration> 10 %10 % – 1 %1 % – 0.1 %< 0.1 %TypicalPathlength0.05 mm0.1 mm0.2 mm> 0.5 mmWhen using diamond compression cells it isworth checking to see if the sample haspreferentially adhered to just one of the windows.www.specac.com102


<strong>Specac</strong> Product Catalogue 2011 | Spectroscopist’s Hints and TipsSpectroscopist’s Hints and TipsThe following hints and tips on Infrared Sampling may help you achieve better spectra withgreater ease. Don’t forget to contact your local <strong>Specac</strong> representative if you need any helpwith your application. Contact details are listed at the back of this catalogue.Reflection MeasurementsTwo ways of reducing the ATR penetration depthinto a strongly absorbing sample are choosing anATR crystal with a higher refractive index (see thelist of optical material properties at the back ofthis catalogue), and selecting a larger angle ofincidence.When analyzing powdered samples using ATR,pre-grinding the sample will improve thehomogeneity of the sample particles, and yieldbetter spectra.Aerosol spray samples can be convenientlyanalyzed using the ATR technique. Spray thecontents onto a flat or trough top-plate, in a fumecupboard, away from the spectrometercompartment.Lacquers and coatings can be analyzed forspecular reflectance in the following way. Wrapaluminium foil (shiny side out) around thereference mirror and apply the coating. Allow todry and record spectra of the resulting film.When using diffuse reflectance the sampleheights are not alway uniform. Each time thesample is changed it is desirable to reach theoptimum height and peak energy as quickly aspossible. A rolling micrometer on the <strong>Specac</strong>Minidiff Plus accessory adjusts the height inseconds, without using tools.Level the surface of a sample for diffusereflectance measurement by gently tampingdown the surface, using a glass slide resting onthe surface under its own weight. Do not pressthe surface hard, and risk compacting thesample. The surface can be seen through theglass slide.www.specac.com103


<strong>Specac</strong> Product Catalogue 2011 | Spectroscopist’s Hints and TipsSpectroscopist’s Hints and TipsThe following hints and tips on Infrared Sampling may help you achieve better spectra withgreater ease. Don’t forget to contact your local <strong>Specac</strong> representative if you need any helpwith your application. Contact details are listed at the back of this catalogue.Transmission MeasurementsAlways wear gloves when handling all infraredwindows to avoid contamination. This is goodpractice even for non-hygroscopic windows.Always check the chemical compatibility of awindow or crystal material by using scrapfragments. If in doubt, contact your local<strong>Specac</strong> representative for assistance.For accessories that are, or maybe, out ofalignment, a small beam white light source isideal for recreating the beam path. Once roughalignment has been recovered, use the energylevel output on the spectrometer in order to finetunethe signal.Test the identity of an unknown window or crystalby measuring the transmission characteristics inthe spectrometer. Be aware that the cut-offvalues quoted in transmission characteristicstables are typically for short pathlengths of a fewmillimeters. Longer paths through ATR crystalswill reduce the absorption cut-off back towardsshorter wavelengths.When using a temperature controlled accessory,always remember to set the temperature to20ºC after use. This will remove the risk ofaccidentally heating the accessory the next timeit is switched on.When cleaning accessory optics it is advisable toremove the accessory from the spectrometer.If this is undesirable, be economical with theamount of solvent used, as large amounts ofsolvent vapour can have an effect on subsequentspectra. It is also advisable to purge theaccessory before use.Choosing Fluorolube as a mulling agent allowsthe study of all CH stretching bands in an infraredspectrum using the mull technique. These aremasked by paraffin absorptions when usingNujol.The use of an O-ring on the plunger body of anevacuable pellet die prevents the plunger fallingonto the newly pressed disk when removing thedisk from the body of the die.Fingerprints can be removed from mirrors byslowly dragging a methanol soaked lens tissueover the surface of the mirror. Use a stream ofdry air to remove excess solvent.www.specac.com104


<strong>Specac</strong> Product Catalogue 2011 | IndexIndexAnvils for ATR, 53, 55, 60, 61ATR, 25 Reflection, 65, 67ATR, Gateway Kit, 50, 62, 63, 64, 65ATR, Golden Gate Diamond ATR, 7, 50, 53, 54,55, 56, 59,ATR, Silver Gate Evolution, 6, 60, 61ATR, 17, 54, 55, 56, 62, 64, 96,106Beam Condenser, Microfocus, 10, 25, 28, 29Demountable Cells, 11, 17, 22Diabrase abrasive sample pads, 68, 69Diamond Compression Cell, 28, 29Dies, 75, 80, 81, 82, 83, 84, 85Dies, Lightweight, 85Diffuse Reflectance, Minidiff , 7, 70, 96Diffuse Reflectance, Monolayer, 7, 54, 71, 72Diffuse Reflectance, Selector , 67, 68, 69Environmental Chamber, 7, 68, 69, 71Film Makers, 89, 90, 91, 94Flow Cells and Kits, 16, 17, 19 20, 98, 99, 100, 101Fluorolube, 104, 107, 13Gas Cells, 10 cm, 31Gas Cells, General, 33, 34, 35, 36, 37, 38, 39, 40,41, 42, 43, 52Gas Cells, Heated 10 cm, 32Gas Cells, Long Path, 21, 34, 35, 36, 37, 38, 39,42, 43,Gasket, 12, 13, 15, 17, 18, 19, 20, 66, 67, 78Heated Platens, 76, 77, 78, 80, 81, 88, 89, 90Heating Jacket, Electrical, 25Heating Jacket, Water, 26High Temperature/High Pressure Cell, 44, 45KBr powder, 69, 70, 84, 86, 92, 95, 96, 102, 108Laser Alignment Accessory, 37Liquid Cells, 6, 11, 15, 16, 17, 18, 19, 20, 96, 101, 109Luer Syringe, 13, 15, 96Magnetic Film Holder, 91, 94, 95, 110,Micro Specular Reflectance, 59, 60Mull Cells, 11, 12Nujol Mull, 10, 11, 13, 95, 107, 108,Oil In Water Analysis Kit, 27Omni Cell System, 11, 12, 13, 109Pestle and Mortar, 70, 84, 95, 96Polarizers, 46, 47, 48, 49, 50, 51Polarizer mounts, 52Presses, Atlas , 15 Ton, 78Presses, Atlas , 25 Ton, 78Presses, Atlas , Power Press, 80Presses, Atlas , Auto Press 81, 82Presses, General, 77, 78, 79, 80, 81, 82Process Cells, 99, 100, 101Professional Starter Kit, 96Purge Bellows, 36, 42, 43Reaction Cell, 7, 58, 61Sealed Cells, 11, 12, 13, 17Solid Cells, 6, 16Spacers, general, 18, 19, 90, 91, 95Spacers, Omni Cell , 11, 12, 13<strong>Specac</strong>abinet , 93<strong>Specac</strong>ards, 94, 110Specadie , 86Specamill , 92Specular Reflectance, Fixed Angle, 7, 73, 96, 110FT-IR Starter Kit, 95Supercritical Fluids, 60, 61Top-plates for ATR, 58, 59, 60, 61, 65Vacuum Pump, 87Variable Pathlength Cell, 15Variable Temperature Cell holder, 23, 24Volatiles Cover, 57, 61Window Polishing Kit, 14Windows, 10 cm Gas Cells, 27Windows, Long Path Gas Cells, 13Windows, Variable Temperature Cell holder, 24Windows, Variable Pathlength Cell, 15www.specac.com105


<strong>Specac</strong> Product Catalogue 2011 | A-Z of IRA-Z of IR100% LineRatio of two background spectra under identicalconditions. Determines condition ofspectrometer, or accessory, and quality ofspectra. An ideal 100% Line would be a horizontalline at 100%.Benchmark<strong>Specac</strong>’s universal compatibility baseplatesystem, adapting <strong>Specac</strong> accessories to allspectrometer models. Also <strong>Specac</strong>’s 6 ReflectionATR System, capable of analyzing almost anysample.AAbsorbanceThe amount of Infrared radiation absorbed by asample. It is proportional to concentration, and isdefined by Beer’s Law, so it can be used forQuantitative Analysis. Often the Y-axis unit inInfrared spectra, absorbance is related totransmittance by A=log10 (1/T), where A is theabsorbance and T is the transmittance.Attenuated Total Reflectance (ATR)A reflectance sampling technique, used in suchaccessories as the Golden Gate and theBenchmark 6 Reflection ATR System. A beam ofInfrared radiation is passed through a prism ofmaterial which is Infrared transparent, and has ahigh refractive index, at least higher than thesample being analyzed. Due to internalreflectance, the light reflects off the surface ofthe crystal at least once, setting up anevanescent wave, which extends into the sampleby typically a few microns. The sample must beheld in intimate contact with the crystal.BBackground SpectrumA single beam spectrum produced without asample in the Infrared beam. It is used to recordthe contributions that the instrument and theenvironment make to the measurement.The sample spectrum can be ratioed against thebackground spectrum to remove thesecontributions.Baseline correctionThe manipulation of a spectrum to correct asloped or curving baseline. The spectroscopistdraws a function parallel to the baseline which isthen subtracted from the spectrum.BeamsplitterAn optical device which reflects half the radiationstriking it, and transmits half.CCalibrationIn Quantitative Analysis, the correlation of peakheights and areas in a spectrum with theconcentrations of standard analytes. Aftercalibration, unknown analyte concentrations canbe calculated.Calibration curveAn Absorbance vs. Concentration plot used incalibration. If the sample obeys Beer’s Law, theplot will be linear and unknown concentrationscan be calculated.CondenserThe optical element that condenses light on asample.Critical AngleDefined as being:c = arcsin (n1/n2)where c is the critical angle for an interfacebetween two specific media, n1 and n2 are therefractive indices of the two media and n 2 hasthe higher refractive index; the critical angle is thesmallest angle of incidence at which totalinternal reflection occurs.DDepth of PenetrationWhen a sample is analyzed using ATR, the depthof penetration is the depth at which theevanescent wave has decreased to 1/e (or36.788%) of its original value after penetratingthe sample. The depth of penetration isdependent on many factors, including the angleof incidence, the refractive index of the ATRcrystal, and the wavelength of the Infraredradiation.Cont’dwww.specac.com106


<strong>Specac</strong> Product Catalogue 2011 | A-Z of IRA-Z of IRDiffractionThe bending of light around the edge of anopaque body, or through a narrow slit, resultingin a series of alternately high and low intensitiesin the shadow of the obstacle.Diffuse reflectionThe random reflection resulting when a beam oflight reflects off a rough, matt surface e.g.powder or fibre.Dispersive InstrumentsInfrared spectrometers that use a grating orprism to disperse Infrared radiation into itscomponent wavelengths before detecting them.This type of instrument is less widespread sincethe arrival of FTIR spectrometers.DRIFTS (Diffuse Reflectance Infrared FourierTransform Spectroscopy)A reflection sampling technique making use ofthe phenomenon of diffuse reflectance.EEvanescent waveA standing wave of radiation set up in an ATRcrystal at the interface with the sample. Thewave penetrates into the sample and an Infraredspectrum can be obtained.FFar IRInfrared radiation between 400 and 10 cm -1 .FluorolubePolymer of trifluorovinyl chloride (-CF2-CFCl-)xused for the preparation of mulls. Unlike Nujol, itdoesn’t mask CH stretch bands.Fourier TransformThe integration performed upon an interferogramto produce an Infrared spectrum.Fourier Transform Infrared (FTIR)SpectrometerThe instrument used for FTIR spectroscopy.FTIR SpectroscopyA method of obtaining an Infrared spectrum bymeasuring the interferogram of a sample usingan interferometer, then performing a FourierTransform upon the interferogram to obtainthe spectrum.GGermaniumElement, atomic number 32, atomic weight72.6:a gray-white metallic semiconductor. Its highrefractive index (4.01) makes it an importantmaterial for ATR crystals, used to analyze highlyabsorbing samples.Golden Gate <strong>Specac</strong>’s world-famous single reflection ATRaccessory, analyzing almost all sample types:hard solids, to powders, to corrosive liquids, to fibres.The Golden Gate is the world’s mostversatile sampling system. The standardDiamond Golden Gate uses a type IIa diamondas the ATR element for unparalleled opticalsensitivity, while diamond’s unique physicalstrength makes it ideal for excellent contact withthe hardest of solids. Its tremendous chemicalstability allows it to withstand corrosive liquids.Other Golden Gate versions available, toaccommodate various types of sample, include aGermanium Golden Gate , whose high refractiveindex is useful for highly absorbing samples, anda heatable version for high temperature analysis.Grazing angle reflectionAn optical phenomenon occurring when theincident Infrared radiation strikes a sample,deposited on a reflective material, at an angle ofaround 80º to the normal. Useful for the analysisof thin coatings, e.g. paints on metallic surfaces.IIndex of refractionA property of a material describing the behaviourof electromagnetic radiation when travellingthrough it (not all EM radiation can travel throughall materials). It is defined as being the ratio ofthe speed of light in a vacuum to the speed oflight in the material concerned. Also calledrefractive index.Infrared (IR) radiationThe region of the electromagnetic spectrum from14,000 to 10 cm -1 .Infrared SpectroscopyThe study of the characteristic Infrared spectra ofmatter.Cont’dwww.specac.com107


<strong>Specac</strong> Product Catalogue 2011 | A-Z of IRA-Z of IRInfrared spectrumA plot of Intensity of Infrared radiation vs.Wavenumber. A spectrum can be interpreted todetermine the molecular structure of the samplefrom which it has been obtained, becausedifferent functional groups in a molecule will eachproduce a unique feature, or fingerprint, in thespectrum.InterferogramA plot of Infrared detector response vs. Opticalpath difference. This is what an FTIRspectrometer measures, to be FourierTransformed to obtain a spectrum.InterferometerAn optical device causing two beams of light totravel different distances to produce an opticalpath difference. This allows constructive anddestructive interference to occur, and changingthe optical path difference allows themeasurement of an interferogram.Internal reflectionThe effect where electromagnetic radiationpassing through a material reflects off thesurface of the material at the interface withanother medium, which has a lower refractiveindex, instead of leaving the material to enter thenew medium. If the angle of incidence is largerthan the critical angle, then none of the light willbe transmitted to the new medium, it will all bereflected. This phenomenon is called total internalreflection.KKBr pelletA pellet produced for use in transmissionanalysis. This technique is used for powdersand other solids. The sample is ground, then“diluted” with KBr powder, before being pressedinto a pellet. The pellet is then mounted on a<strong>Specac</strong>ard before being placed directly in theInfrared beam for analysis.Kramers-Kronig TransformA mathematical calculation performed uponspecular reflectance spectra to eliminate theeffect of variations in the refractive index of thesample. It results in ak-spectrum and ann-spectrum, which are the true absorbancespectrum and a plot of Refractive index vs.Wavenumber respectively.KRS-5Trade name for thallium iodide bromide, acommon ATR crystal material (Refractive index2.38) with Near IR and Mid IR transmissioncharacteristics.Kubelka-Munk unitsUnit of intensity of diffuse reflected light. TheKubelka-Munk equation relates this intensity tothe concentration and scattering factor of asample. The scattering factoris determined bythe particle size, shape and packing density, butcan be difficult to quantify.MMicrometerA gauge for accurately measuring smalldistances, thicknesses etc.Mid IRInfrared radiation between 4,000 and 400 cm -1 .MullA Transmission sampling technique. A solidsample is ground, then dispersed in a mullingagent (e.g. Nujol). The mull mixture is thensandwiched between two windows (e.g. KBr) inan Omni-Cell body before being placed directly inthe Infrared beam.Mulling agent(Usually) an oil added to a ground sample in thepreparation of a mull.NNear IRInfrared radiation between 14,000 and 4,000cm -1 .NujolA liquid paraffin used for the preparation of mulls.Nujol is not always the best mulling agent as itmasks any CH stretch bands that wouldotherwise be seen in the sample spectrum.Cont’dwww.specac.com108


<strong>Specac</strong> Product Catalogue 2011 | A-Z of IRA-Z of IROmni Cell With over 400 window and pathlengthcombinations available as standard, to cater forevery sample and wavelength of interest,<strong>Specac</strong>’s Omni Cell is the simple stand mostversatile Infrared transmission cell systemavailable anywhere. The Omni Cell can beconfigured as a sealed liquid cell, a demountableliquid cell, or a mull cell. Easily assembled, ordisassembled, in a few seconds, it is designedfor fast sample turn-around. With a knownpathlength, the spectrum from an Omni Cell is suitable for Quantitative Analysis.PPeak-to-Peak NoiseA noise measurement often made on a 100%Line to determine spectrum quality andinstrument performance when obtained undercontrolled conditions. It is measured as thedifference between the lowest and highesttransmittance value in a specific wavenumberrange.PolarizerA device for converting light into polarized light.Typically, polarizers are a ZnSe substrate withthin parallel gold wires on the surface to forma grid.Polymer filmA thin film, of precise thickness, pressed at anelevated temperature using a <strong>Specac</strong>Constant Thickness Film Maker Kit. The film canthen be mounted in a magnetic film holder beforebeing placed directly in the Infrared beam fortransmission analysis.QQuantitative AnalysisCalculation of sample concentration usingmeasurements from a spectrum, such as bandratios and peak areas and heights.This techniquerequires a calibration before unknownconcentrations can be determined.RRaman effectWhen monochromatic light is scattered bymolecules, a small fraction of the scattered lightis observed to have a different frequency fromthat of the incident beam; this is the Ramaneffect. Raman spectroscopy can reveal vibrationsthat may be inactive under Infrared analysis, andtherefore can provide complementaryinformation about the molecular structure of thesample under examination. The <strong>Specac</strong> VariableTemperature Cell holder is suitable for the RamanTechnique.Reflection AbsorptionAlso known as “Double-transmission”, reflectionabsorption is a sampling technique used on thincoatings on metal. The Infrared beam passesthrough the coating again after reflecting off themetal surface, before reaching the detector.Refractive IndexSee Index of Refraction.ResolutionMeasure of the ability of a spectrometer todistinguish features of a spectrum which are veryclose together.SScanThe measuring of an interferogram in FTIR.Usually involves cycling the mirror in theinterferometer once.Sealed Liquid CellsBasic accessories used to obtain transmissionspectra of liquids. Consists of two IR transparentwindows (e.g. NaCl), held apart by a spacer,filled with the liquid under consideration. The cellis then put directly into the beam. <strong>Specac</strong>’sadvanced Omni-Cell system can be configuredfor use as a sealed liquid cell, with 9 options forwindows and 6 options for pathlength to give 54standard combinations.Cont’dwww.specac.com109


<strong>Specac</strong> Product Catalogue 2011 | A-Z of IRA-Z of IRSelector <strong>Specac</strong>’s versatile diffuse reflectance accessory,featuring unique off-axis optics to fully minimizeunwanted specular reflectance, offers rapid FTIRanalysis of solids with minimal samplepreparation. The Selector can include anEnvironmental Chamber, for extremetemperature and pressure analyses, anAutosampler, to automatically analyze up to 32samples, and an X-Y stage, for sample mappingof large or inhomogeneous samples.Signal-to-Noise Ratio (SNR)To determine the quality of a spectrum, orspectrometer, the SNR is the ratio of the signal,or intensity, of the spectrum to the noise at anearby point on the baseline.SiliconElement, atomic number 14, atomic weight28.09, grayish metallic semiconductor.A very hard, inert crystal with a refractive index of3.42, Silicon is very useful for Far IR in the range400 to 30cm -1 .Single Beam SpectrumThe spectrum obtained after FourierTransforming an interferogram. The single beamspectrum is a combination of the spectra of thesample (if applicable), the instrument and theenvironment.Sirocco Gas Cell<strong>Specac</strong>’s advanced transmission gas analysiscell is a new concept in gas cell specification.With an extensive array of standard features onthe base unit, personalized modifications can bemade from a range of precision engineeredoptions. A range of pathlength options allowsanalysis at low pressures to be performed in thelonger cells, and pathlengths can be verified witha laser alignment accessory.<strong>Specac</strong>ard Mount for the transmission analysis, and storage,of KBr pellets. <strong>Specac</strong>ards can also be used,with a magnetic film holder, for polymer films.Specular ReflectanceThe reflectance occurring when a beam of lightstrikes a smooth, shiny surface, e.g. a mirror,such that the angle of incidence equals the angleof reflection. Specular reflectance can be used toobtain Infrared spectra.TTransmissionA physical phenomenon where radiation passesthrough a body.When producing a transmissionspectrum a proportion of the energy is absorbedby the sample, while the remainder travels on tothe detector.Transmission SamplingThe method of sampling whereby the Infraredbeam passes directly through the sample beforebeing detected, used in such accessories as theVariable Temperature Cell holder, the Omni Cell and the Sirocco Series Gas Cell. An appropriatepathlength must be selected so as to avoid totalabsorption of the Infrared.TransmittanceUnit of measurement of the amount of radiationtransmitted by a sample. It is often the Y-axis ofInfrared spectra. Transmittance is not linearlyproportional to the concentration of the sample,therefore spectra plotted with these units cannotbe used for Quantitative Analysis.VVariable Temperature Cell holder<strong>Specac</strong>’s most advanced accessory for thetransmission analysis of liquids and solids attemperatures from -190ºC to 250ºC. Choice ofwindow material allows this accessory to beused in UV, Visible and Infrared regions. Thisaccessory can also be used for Fluorescenceand the Raman Technique.WWavelengthOne wavelength is the distance between twoidentical points on two adjacent identical wavesin a beam.WavenumberWavenumber is defined as the reciprocal of thewavelength expressed in cm. Units are cm -1 .Wave numbers are normally the units along theX-axis in Infrared spectra.www.specac.com110


<strong>Specac</strong> Product Catalogue 2011 | Optical Materials for SpectroscopyOptical Materials for SpectroscopyWindowmaterialfromRangetoRefractiveIndex at2000cm -1General PropertiesMgF2 91,000 1,100 1.37Almost insoluble in water. Hard material suited to relatively high pressure applications. Bi-refringent andsubject to thermal shock. Should not be used above 500°C.LiF 83,000 1,400 1.33 Slightly water soluble. Hard, brittle material. Subject to thermal shock. Should not be used above 400°C.CaF2 77,000 900 1.40BaF2 66,666 800 1.45NaCl 40,000 600 1.52AMTIR 11,000 725 2.50AgBr 22,000 300 2.30KCl 33,000 400 1.40KBr 43,500 400 1.54KRS-5 17,000 250 2.38Insoluble in water, resists most acids and alkalis. Soluble in ammonium salts. Its high mechanical strengthmakes it particularly useful for high pressure work. Sensitive to mechanical and thermal shock. Does not fog.Insoluble in water, soluble in acids and NH4Cl. Very sensitive to mechanical and thermal shock.Good resistance to fluorine and fluorides. Does not fog.Soluble in water and glycerine. Slightly soluble in alcohols. Fair resistance to mechanical and thermal shockand can be easily polished.Amorphous Material which Transmits Infrared Radiation. A chalcogenide glass which although relatively hardis brittle. Insoluble in water, resistant to acid but attacked by alkalis.Insoluble in water, soluble in acids and NH4CL. Very sensitive to mechanical shock and is malleable.Will cold form. Good resistance to thermal shock. Corrosive to metals and alloys. Sensitive to strong UVradiation and will darken with long exposure.Hygroscopic material similar to NaCl but with extended transmission range.Less soluble and lower reflection losses.Hygroscopic material similar to NaCl. Soluble in water, glycerine and alcohols. Slightly soluble in ether.Fairly good resistance to mechanical and thermal shock.This material is a mixture of Thallium Bromide and Thallium Iodide salts and is extremely toxic.Orange/red in colour. Slightly soluble in water, soluble in bases, but not soluble in acids. Not hygroscopic.Good transmission range and is ideal for ATR work. Soft, hence easily deformed.CsBr 42,000 250 1.66 Hygroscopic material. Soluble in water and acids. Soft, hence easily deformed.CsI 42,000 200 1.74Extremely hygroscopic material. Soluble in water and alcohols. Useful because of wide transmission range.Mildly toxic.Silica SiO 2UV Grade59,000 3700 1.46Resistant to acids and alkalis and unaffected by most solvents. Transmission at 50,000cm-1 is98% for UV grade and 40% for IR grade.Silica SiO 2IR Grade40,000 3000 1.46Resistant to acids and alkalis and unaffected by most solvents. Transmission at 50,000cm-1 is98% for UV grade and 40% for IR grade.ZnS(Cleartran)50,000 770 2.25ZnSe 20,000 500 2.43Ge 5,000 550 4.01Diamond 40,000 10 2.40Si 8,333 33 3.42Insoluble in water, normal acids and bases and virtually all organic solvents.Reacts to strong oxidising agents. Good resistance to thermal and mechanical shock.Suitable for work in temperature range -200°C to 800°C.Toxic, hard and brittle material. Amber/yellow in colour. Insoluble in water, but attacked by strong acidsand bases (pH range 4 to 11 tolerant). Organic solvents have no effect. Ideal for ATR work.Low absorption at 10.6 microns hence popular window material for CO2 lasers.Hard and very brittle material. Is temperature sensitive and loses transmission when heated.Optically opaque at 190°C. Insoluble in water. Soluble in hot sulphuric acid and aqua regia.Suitable for ATR work where high pressure contact is not required.Very hard and extremely chemically resistant. A diamond window is often chosen for highpressure applications. Excellent for ATR work.Very hard, but brittle and relatively inert material. Is attacked by a combination of HF and HNO3.Withstands thermal shock. Useful for Far IR. in the region 400-30cm-1.Polyethylene625 4 1.52Inexpensive Far IR window material. Insoluble in water but tends to swell and be contaminated withsome organic solvents. Melting point 110°C.111www.specac.com


<strong>Specac</strong> Product Catalogue 2011 | Noteswww.specac.com112


<strong>Specac</strong> Product Catalogue 2011 | Worldwide DistributionWorldwide DistributionU.K.<strong>Specac</strong> Ltd.River House97 Cray AvenueOrpingtonKent BR5 4HEU.K.T: + 44 (0)1689 873134F: + 44 (0)1689 878527sales@specac.co.ukwww.specac.comMain OfficesU.S.A.<strong>Specac</strong> Inc.50 Sharpe DriveCranstonRhode Island 02920U.S.A.Toll free: 1 800 447 2558T: 401 854 5281F: 401 463 6206sales@specac.co.ukwww.specac.comExclusive DistributorsFranceEurolabo35 Rue de Meux75019 ParisFranceT: 01 42 08 01 28F: 01 42 08 13 65contact@eurolabo.frwww.eurolabo.frGermanyL.O.T. Oriel GmbHIm Tiefen See 58D-64293 DarmstadtGermanyT: +49 6151 88060F: +49 6151 896667info@lot-oriel.dewww.lot-oriel.com/deSpainTeknokroma S. Coop C. LtdaPO Box 14708190 Sant Cugat del VallesBarcelonaT: +34 936 748 800F: +34 936 752 405comercial@teknokroma.eswww.teknokroma.es/esSwitzerlandPortmann Instruments AGGewerbestrasse 18CH-4105 Beil-BenkenSwitzerlandT: +41 61 726 65 55F: +41 61 726 65 50info@portmann-instruments.chwww.portmann-instruments.ch/chJapanSystems Engineering6-12-17 HonkomagomeBunkyo-kuTokyo 113-0021JapanT: 03 3946 4993F: 03 3946 4983systems-eng@systems-eng.co.jpwww.systems-eng.co.jpwww.specac.com113


illiant spectroscopy UK<strong>Specac</strong> Ltd., River House, 97 Cray Avenue, Orpington, Kent, BR5 4HE U.K.T: + 44 (0)1689 873134 F: + 44 (0)1689 878527sales@specac.co.ukUSA<strong>Specac</strong> Inc., 50 Sharpe Drive, Cranston, Rhode Island , 02920 U.S.A.Toll free: 1 800 447 2558 T: 401 854 5281 F: 401 463 6206sales@specac.co.ukwww.specac.com