FIRE DETECTION<br />

SYSTEMS<br />

Product catalogue


JUNO-SYS<br />

One loop analogue addressable control panel<br />

FUNCTIONAL CHARACTERISTICS<br />

Single loop panel - Non expandable<br />

Smaller Size: Junior 314x320x80<br />

Supports connection to Mini-repeater via RS485 and/or fibre-Optic interfaces<br />

125 device addresses<br />

96 VULCAN (addressable) ultra low current base sounders (32 address limit)<br />

32 individually programmable sounder addresses<br />

Full SAM (Self Addressable Module) support<br />

2 Fire output relays (change-over) and 1 Fault relay (change-over)<br />

2 conventional alarm outputs (Individually programmable)<br />

All detector loops monitored for integrity<br />

384 fully programmable zones<br />

512 fully programmable sounder groups<br />

Event log (rolling, 2000 entries)<br />

Compatible with Apollo S90 /XP95T and DiscoveryT Protocols<br />

Compatible with all our own low cost ancillary modules<br />

Backlit LCD display with 4 rows of 40 characters<br />

Programming by integrated keypad<br />

Multiple language support (menu selectable)<br />

Optional <strong>fire</strong> and fault LED zone indication<br />

Integrated 8 zone LED <strong>fire</strong> zone indication<br />

Interactive DiscoveryT functions<br />

Pr.Id.:30103<br />

2


RAIK Pr.Id.:30100<br />

1-3 loops analogue addressable control panel<br />

RAIK-1<br />

RAIK-1 is an analogue addressable control panel with<br />

modular 1-3 loop configuration with 32 zones. Main unit is<br />

composed from RAIK A and B modules. Analogue loops are<br />

created with modules RAIK-M . See accessories bellow<br />

CHARACTERISTICS<br />

DETECTOR INPUTS<br />

ALARM OUTPUTS<br />

PROGRAM OUTPUTS<br />

SERVICE PORTS<br />

EVENT BUFFER<br />

ACCESSORIES<br />

PGD<br />

Pr.Id.:31103<br />

RAIK-M<br />

Pr.Id.:31100<br />

under UNI EN54-2 and UNI<br />

EN54-4 , power supply 2A/24Vdc<br />

- max 378 analog detectors on 3<br />

(6) loops<br />

- max 248 conventional local or<br />

remote lines (loop RS485)<br />

- 32 zone<br />

- alarm output with indication of short<br />

circuit<br />

- max 6 outputs el. programed<br />

- max 64 outputs programmed on 8 channel<br />

adapters, local or remote<br />

- alarm and trouble output N.O./ N.C.<br />

- connection with a PC trough RS-232/485<br />

- serial clock/date output<br />

- local bus SPI for connection with I/O adapters<br />

Internal buffer for 800 evens, pos<strong>si</strong>ble to download to a PC or<br />

print to RS232<br />

Remote LCD indication keyboard<br />

Analogue addressable loop card for<br />

expan<strong>si</strong>on of loop with 126 address or<br />

2 loops of 63 address<br />

RAIK-U Input module with 8 inputs<br />

Pr.Id.:31101<br />

RAIK-I Output module with 8 relay outputs<br />

Pr.Id.:30102<br />

ANALOGUE ADDRESSABLE CONTROL PANEL<br />

3


FUNCTIONAL CHARACTERISTICS<br />

Fully expandable system - from 1 to 96 loops<br />

125 device addresses per loop<br />

96 VULCAN (addressable) ultra low current base sounders per loop<br />

32 individually programmable sounder addresses per loop<br />

2 Fire output relays (change-over)<br />

Open collector outputs for Fire, Fault and Pre-alarm remote indicators<br />

2 conventional alarm outputs on each Main Panel and Sub-panel<br />

Repeaters with optional Integrated Sub-panels<br />

All detector loops monitored for integrity<br />

384 fully programmable zones<br />

512 fully programmable sounder groups<br />

1 TO 3 LOOPS Event log (rolling, 2000 entries)<br />

Compatible with Apollo S90/XP95 and Discovery Protocols<br />

Compatible with all our own low cost ancillary modules<br />

Backlit LCD display with 4 rows of 40 characters<br />

Programming by infra-red remote keypad, PC keyboard and Windows based‘Loader’ software<br />

Windows based PC graphics software for alarm management and reporting<br />

Multiple language support (menu selectable)<br />

BMS output (RS232)<br />

Evacuate/Class Change input<br />

Multi-panel network by RS485 or fibre optic links<br />

Optional internal 40 column thermal printer<br />

Optional <strong>fire</strong> and fault LED zone indication<br />

ELECTRICAL & MECHANICAL CHARACTERISTICS<br />

Primary supply voltage<br />

Secondary supply voltage<br />

Power supply rating<br />

Sounder output rating<br />

Auxiliary output rating<br />

Battery fuse rating<br />

Auxiliary contact rating<br />

Quiescent current w/out devices<br />

Box *<br />

Cable entries<br />

Dimen<strong>si</strong>ons (1-3 loops box)<br />

Dimen<strong>si</strong>ons (1-12 loops box)<br />

Dimen<strong>si</strong>ons (sub-panel box)<br />

Dimen<strong>si</strong>ons (mini-repeater box)<br />

Battery Capacity<br />

Weight<br />

JUNO NET<br />

Analogue addressable network control panel<br />

4<br />

85-265V AC 50/60Hz<br />

24V DC nominal<br />

60W or 150W output<br />

1 Amp<br />

1 Amp fused<br />

3 Amp<br />

1A 50V AC/DC<br />

130 mA<br />

1.5mm aluminum or mild steel coated white<br />

Back through cut out/top by 6 removable plugs<br />

H: 370 W: 340 D: 127 (mm)<br />

H: 420 W: 550 D: 127 (mm)<br />

H: 370 W: 340 D: 127 (mm)<br />

TBA<br />

Up to 2 x 12V 12A/H<br />

6.5 Kg


1, 3 LOOP Juno-NET 100 Pr.Id.:30109 Juno-NET300<br />

4-12 LOOPS Juno-NET 400<br />

JUNO NET<br />

Analogue addressable network control panel<br />

5<br />

Pr.Id.:30105<br />

Pr.Id.:30104


JUNO NET<br />

Analogue addressable network control panel<br />

REP<br />

REPEATER WITH OR WITHOUT INTEGRATED SUB-PANEL<br />

The JUNO-NET repeater has an identical appearance to the JUNO-NET main panel and has <strong>si</strong>milar<br />

electrical characteristics. It allows full control and programming of the entire <strong>fire</strong> protection system as if<br />

you were at the main panel. A repeater with integrated sub-panel allows a distributed system topology<br />

ideal for multiple building networks where display and control is necessary in each building. Each<br />

integrated sub-panel has its own unique (programmable) address and can have either one or three<br />

<strong>detection</strong> loops. From the user perspective the only difference between a repeater and the main panel is<br />

that a repeater cannot support a printer.<br />

SUB-PANEL<br />

Whenever a <strong>fire</strong> alarm system grows beyond 3 loops in terms of either<br />

<strong>detection</strong> points or topology, it is pos<strong>si</strong>ble to add sub-panels in<br />

increments of 3 loops and supplied in fully closed cabinets, provided<br />

with independent primary and secondary power supplies. In each<br />

cabinet it is pos<strong>si</strong>ble to install 1, 2 or 3 sub-panel boards with each<br />

board containing 3 loops, hence the 1-9 loops capability. The power<br />

supply is 5.4A PSU/Charger. Only one RS-422/485 or Fibre-optic<br />

interface is needed in each cabinet to provide the communication<br />

path to the rest of the system. These cabinets can be installed closer<br />

to the <strong>fire</strong> monitoring devices, enabling <strong>si</strong>gnificant savings in<br />

expen<strong>si</strong>ve <strong>fire</strong>-proof cabling<br />

REP-Mini<br />

This sleek, unobtru<strong>si</strong>ve repeater panel can be used to control any<br />

distributed, or self-contained JUNO-NET based <strong>fire</strong> alarm system.<br />

Because of its reduced dimen<strong>si</strong>ons it is especially recommended for<br />

front desk monitoring of large <strong>systems</strong> where it would be impractical to<br />

place a full <strong>si</strong>ze control panel in a cluttered reception booth. Up to 10<br />

repeaters can be connected to a main JUNO-NET <strong>fire</strong> alarm panel, all<br />

of which offer full control over the system. Connection to the JUNO-<br />

NET is via its data-loop communication bus and can be through an RS-<br />

422/485 or Fibre-optic interface. Compatible with Juno-SYS.<br />

6<br />

Pr.Id.:30114<br />

Pr.Id.:30113<br />

Pr.Id.:30108


J-NET-LOOPCON<br />

CHARACTERISTICS<br />

DIMENSIONS: FACE PLATE 76 x 76 x 2 (mm)<br />

DIMENSIONS: INDICATOR: 68 x 33 x 25 (mm)<br />

Loop card-1 & Loop card-3<br />

CHARACTERISTICS<br />

DIMENSIONS: FACE PLATE 76 x 76 x 2 (mm)<br />

DIMENSIONS: INDICATOR: 68 x 33 x 25 (mm)<br />

SUB-PANEL<br />

CHARACTERISTICS<br />

DIMENSIONS: FACE PLATE 76 x 76 x 2 (mm)<br />

DIMENSIONS: INDICATOR: 68 x 33 x 25 (mm)<br />

LOOP CONNECTOR<br />

This interface board provides a separate area for connecting the addressable<br />

loops wiring. It also has the entry level filtering to reduce overall noise<br />

susceptibility of the JUNO-NET panel ( needed if REP + loop card are used)<br />

LOOPCARD - SINGLE AND THREE LOOPS<br />

These are the work-horses of our range of panels. Since their creation in 1992 they have been improved in<br />

many respects, reaching today an unparalleled performance in their function of interfacing the real world of<br />

the loop wiring and devices, with the sen<strong>si</strong>tive electronics of an advanced <strong>fire</strong> alarm control panel.<br />

The sub-panel board is in essence a building block of a<br />

JUNO-NET control panel, either in a distributed or self<br />

contained topology.<br />

Capable of managing up to 3 loops of analogue<br />

addressable devices, it will operate on its own even in the<br />

event of lack of communication with the JUNO-NET main<br />

panel, detecting <strong>fire</strong> and fault <strong>si</strong>tuations and activating its<br />

own loop sounders, I/O units etc.<br />

This unit is also the processor board for the JUNO-NET<br />

Mini-Repeater as well as our low-costing <strong>si</strong>ngle loop<br />

panel named JUNiOr. JUNiOr will be out towards end of<br />

2003.<br />

Printer<br />

CHARACTERISTICS<br />

WEIGHT:<br />

DIMENSIONS:<br />

JUNO NET<br />

Analogue addressable network control panel<br />

Pr.Id.:30118<br />

Pr.Id.:30106 Pr.Id.:30107<br />

Pr.Id.:30108<br />

Pr.Id.:30110<br />

208 grams (including paper roll)<br />

H: 65 W: 145 D: 45 (mm)<br />

This 40 column internally mounted thermal printer provides a log<br />

of all the relevant events occurring in the JUNO-NET system. All<br />

events are date and time stamped and are backed up by the 2000<br />

events deep rolling log kept in the panel proces<strong>si</strong>ng unit.<br />

NOTE: In order for the printer to work properly it is necessary that<br />

the J-NET-QUART chip (pictured) be installed on the JUNO-NET<br />

main board.<br />

7<br />

ACCESSORIES<br />

SUB-PANEL BOARD<br />

INTERNAL PRINTERP I N<br />

O TO


If the system is distributed, the communication between the main panel and the external sub-panels or<br />

repeaters is supported by either an RS422/485 fully redundant loop or alternatively fibre-optic cable.<br />

In both cases the data loop is protected from interruptions or via short-circuits by creating a bi-directional<br />

communication flow. If the main panel is unable to communicate with a sub-panel or repeater, it will try<br />

reaching it through the oppo<strong>si</strong>te direction and <strong>si</strong>gnal a communication fault. If RS422/485 is to be used, the<br />

cable needed will be a 4 core shielded and <strong>fire</strong> proof data cable, running a loop from the main panel through all<br />

the repeaters and sub-panels in the system and returning to the main panel.<br />

It is de<strong>si</strong>rable to use fibre-optic cable for the data loop when longer distances between nodes demand it<br />

(above 1200 m) or in premises with high levels of electrical disturbances. The cable used for this type of<br />

connection should be dual core sheathed <strong>fire</strong> proof with 62.5/125 fibre terminated in ST connectors. This type<br />

of data loop is also fully redundant and permits distances between nodes of up to 4.5 Km.<br />

J-NET-INT-485<br />

CHARACTERISTICS<br />

WEIGHT:<br />

DIMENSIONS:<br />

WEIGHT:<br />

DIMENSIONS:<br />

34 grams<br />

H: 25 W: 115 D: 10 (mm)<br />

This board is a complement to the J-NET-INT-485, and provides<br />

the screw connection terminals that do not fit in the former PCB is<br />

reduced dimen<strong>si</strong>ons. It also provides spark-gap discharge<br />

protectors for each in or outbound connection, improving the<br />

degree of protection against atmospheric discharge interference.<br />

J-NET-INT-FO<br />

CHARACTERISTICS<br />

22 grams<br />

H: 39 W: 77 D: 9 (mm)<br />

EXTERNAL RS485 INTERFACE<br />

FIBRE-OPTIC COMMUNICATION INTERFACE<br />

This interface unit converts the TTL level networking <strong>si</strong>gnals to dual channel optical fibre<br />

compatible levels, to allow long distance interconnection between a JUNO-NET main<br />

panel and either one or more sub-panels and/or repeaters with or without integrated<br />

sub-panels.<br />

The optical inputs and outputs are inherently optically isolated from the panel or subpanel<br />

to which it is connected. This optical isolation avoids disturbance created by<br />

ground loops and ensures complete protection from pos<strong>si</strong>ble shock hazards and wiring<br />

mistakes.<br />

The TTL connections are via a 5 pin Molex connector which carries the supply and TTL<br />

Quart COMS<br />

CHARACTERISTICS<br />

WEIGHT:<br />

DIMENSIONS:<br />

Pr.Id.:30117<br />

Pr.Id.:30112<br />

JUNO NET<br />

Analogue addressable network control panel<br />

Pr.Id.:30116<br />

28 grams<br />

H: 41 W: 65 D: 20 (mm)<br />

When the need arises to interface the JUNO-NET with<br />

the out<strong>si</strong>de world, you will be required to use one of the<br />

following units. If your requirements are<br />

Uploading/Downloading data from your PC to the main<br />

panel, connecting your system to a graphics software<br />

like the Odyssey or the installation of an external<br />

printer, then you will need the J-NET-INT-COMS board<br />

correctly configured for each of the above mentioned<br />

purposes. Identification of the boards is by way of<br />

labels <strong>si</strong>nce the corresponding configuration of each<br />

board is done in factory.<br />

8<br />

ACCESSORIES<br />

OPTION<br />

OPTION COMMUNICATION INTERFACE OPTION


or many <strong>fire</strong> alarm <strong>systems</strong>, all that is<br />

required is a <strong>si</strong>mple stand-alone <strong>fire</strong> alarm<br />

panel, monitored by a receptionist or<br />

Fsecurity guard.<br />

Pr.Id.:30111<br />

Panel list screen with 5 panels connected<br />

Juno 1-3 loop panel display<br />

9<br />

A printer can be connected to the computer to<br />

record all alarm, fault and programming activity<br />

on the system.<br />

Initial alarm screen showing general area<br />

Highest zoom showing detector in alarm<br />

Juno NET panel display Front page showing Telephone Nº utility


ADDRESSABLE DETECTORS<br />

The X series is a precise, and high reliable EN-54 approved Analog Addressable smoke<br />

alarms. It comes with a series of 3 different types: smoke only (X-O), heat only (X-T), and<br />

smoke + heat combination (X-O/T) <strong>detection</strong>.<br />

ADDRESSABLE X SERIES<br />

�Dual LEDs for 360°vi<strong>si</strong>bility<br />

�Advanced <strong>detection</strong> and discrimination<br />

algorithms<br />

�Easy installation and maintenance<br />

�Sleek low-profile hou<strong>si</strong>ng de<strong>si</strong>gn<br />

�Durable sensor head, no need for<br />

replacement<br />

�SMD circuit board de<strong>si</strong>gn-satisfactory<br />

quality and reliability guaranteed<br />

�Five-year limited warranty<br />

�Sensor base option: standard and Shottky<br />

Diode<br />

Pr.Id.:32522 Pr.Id.:32523 Pr.Id.:32524<br />

Model X-O X-T X-O/T<br />

2/4 Wire 2 2 2<br />

Thermal / Optical Optical Thermal Thermal/Optical<br />

Voltage DC 15-30V 15-30V 15-30V<br />

Standby Current (Max) 370�A<br />

370�A 370�A<br />

Alarm Current (Max) 370�A 370�A 370�A<br />

Surge Current (Max) 370�A 370�A 370�A<br />

Start-Up Time (Max) 30sec 30sec 30sec<br />

Permis<strong>si</strong>ble Current (Max) 80mA<br />

80mA 80mA<br />

Frequency 3-5sec 3-5sec 3-5sec<br />

Base Model X-B X-B X-B<br />

10


X-MCPA-KAC<br />

ELECTRICAL CHARACTERISTICS<br />

ADDRESSABLE LOOP CURRENT<br />

LOOP CURRENT (NORMAL) 0,35 mA<br />

LOOP CURRENT (FIRE)<br />

3,1 mA<br />

OPERATING TEMPERATURE: 0 - 85°C<br />

HUMIDITY:<br />

30 - 95% NON-CONDENSING<br />

X-MCPA-FLAP<br />

ELECTRICAL CHARACTERISTICS<br />

ADDRESSABLE LOOP CURRENT<br />

LOOP CURRENT (NORMAL) 0,35 mA<br />

LOOP CURRENT (FIRE)<br />

3,1 mA<br />

OPERATING TEMPERATURE: 0 - 85°C<br />

HUMIDITY:<br />

30 - 95% NON-CONDENSING<br />

S-MCPA-2470<br />

Pr.Id.:32114<br />

MANUAL CALL POINTS<br />

ADDRESSABLE MANUAL CALL-POINT UNIT<br />

MECHANICAL CHARACTERISTICS<br />

WEIGHT<br />

150 grams<br />

DIMENSIONS H: 52 W: 87 D: 87 (mm)<br />

WIRE CAPACITY<br />

2<br />

up to 2,5mm<br />

FIXINGS<br />

surface mount: 4 holes<br />

The X-MCPA-KAC manual call point uses a new<br />

communication mechanism that gives a typical alarm response time<br />

of approximately one second and yet does not use Apollo's patented<br />

interrupt bit solution. This new communication system is fully<br />

compatible with all our addressable modules, SAM's, S90, XP95 and<br />

Discovery detectors. Like Apollo's interrupt based system, the more<br />

call points on a loop, the longer the time from activation to alarm.<br />

Pr.Id.:32526<br />

ADDRESSABLE MANUAL CALL-POINT UNIT (LOW-PROFILE)<br />

Both the MCPA-KAC and the MCPA-FLAP are addressable manual callpoints,<br />

compatible with a ver<strong>si</strong>on of the meter bus protocol used by several<br />

panel manufacturers, used for <strong>si</strong>gnaling an emergency or <strong>fire</strong> <strong>si</strong>tuation to an<br />

addressable <strong>fire</strong> <strong>detection</strong> control panel. The main features of these units are<br />

their low quiescent power consumption and low cost. An 8 way DIL switch is<br />

used for setting the address of the unit within the communication loop.<br />

Addresses 0 to 125 can be programmed in binary code, where a switch in the<br />

“OFF” po<strong>si</strong>tion represents a “0”. This unit returns an analog value of 16 when<br />

the glass is intact and a value of 64 when the glass panel has been pressed.<br />

The unit is provided with a bi-color LED which <strong>si</strong>gnals with a green light flash<br />

when the unit is being interrogated by the control panel. When in ALARM, the<br />

LED is illuminated in red by command of the control panel.<br />

Pr.Id.:32116<br />

MECHANICAL CHARACTERISTICS<br />

WEIGHT<br />

80 grams<br />

DIMENSIONS H: 28 W: 120 D: 80 (mm)<br />

WIRE CAPACITY<br />

2<br />

up to 2,5mm<br />

FIXINGS<br />

surface mount: 2 holes<br />

CONVENTIONAL MANUAL CALL-POINT UNIT (LOW-PROFILE)<br />

ELECTRICAL CHARACTERISTICS<br />

MECHANICAL CHARACTERISTICS<br />

QUIESCENT DC CURRENT<br />

40 µ A<br />

WEIGHT<br />

80 grams<br />

FIRE CURRENT<br />

20 mA<br />

DIMENSIONS H: 52 W: 87 D: 87 (mm)<br />

OPERATING TEMPERATURE 0 - 85°C<br />

WIRE CAPACITY<br />

2<br />

up to 2,5mm<br />

HUMIDITY<br />

30 - 95% NON-CONDENSING FIXINGS<br />

surface mount: 2 holes<br />

The S-MCPC-2470 is a conventional manual call-point compatible with all conventional <strong>fire</strong> alarm control panels.<br />

The main feature of this unit is the use of a bi-color LED to <strong>si</strong>gnal the operational status of the call-point. The<br />

included LED blinks regularly with the green color while connected to a <strong>detection</strong> zone and lights with a permanent<br />

red light when activated, (alarm condition). This, allied with its very competitive price and aesthetic appearance ,<br />

make the S-MCPC-2470 a very attractive product.<br />

11


SOUNDERS FEATURING LOW POWER CONSUMPTION & HIGH SOUND OUTPUT<br />

1 2 3 4 5 6 7 8<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

X-VIPER - A<br />

X-VIPER - A<br />

CHARACTERISTICS<br />

STANDARD SHADOW<br />

SUPPLY VOLTAGE:<br />

17-40 V DC 17-40 V DC<br />

CURRENT CONSUMPTION QUIESCENT: 1 mA<br />

1 mA<br />

CURRENT CONSUMPTION ALARM: 6 mA<br />

6 mA<br />

HIGH FREQUENCY SOUND: 11 mA<br />

11 mA<br />

ADDRESS RANGE:<br />

94 - 125 (32/Loop) SHADOW (64/Loop)<br />

PROGRAMMING DATA FOR ADDRESSABLE BASE SOUNDER<br />

SWITCHES 1-5: REGULAR ADDRESSES FROM 094 TO 125 IN BINARY<br />

SWITCH 6: OFF: IAS LOOP SOUNDER ON: APOLLO SOUNDER CIRCUIT CONTROLLER<br />

SWITCH 7 & 8: OFF: SWEEP SOUND (800 - 1000 Hz)<br />

SWITCH 7 ON & 8 OFF: ALTERNATE SOUND (2800 - 3500 Hz)<br />

SWITCH 7 OFF & 8 ON: ALTERNATE SOUND (800 - 1000 Hz)<br />

SWITCH 7 & 8: ON: CONTINUOUS (800 Hz)<br />

X-VIPER SE<br />

CHARACTERISTICS<br />

X-VIPER - BEACON<br />

CHARACTERISTICS<br />

ADDRESSABLE SOUNDERS<br />

Pr.Id.:32532<br />

VIPER ADDRESSABLE SOUNDER<br />

WEIGHT:<br />

153 grams<br />

DIMENSIONS: DIAMETER: 100 - HEIGHT: 85 (mm)<br />

SOUND OUTPUT: 85dB @ 1 METRE (92dB High Pitch)<br />

TONES:<br />

4 TONES SELECTED BY DIL SWITCH<br />

PROTECTION RATING: IP65<br />

__<br />

++ ++ _<br />

__<br />

__<br />

CONNECTION DIAGRAM<br />

WEIGHT:<br />

DIMENSIONS:<br />

CONTINUOUS TONE:<br />

RAMP TONE:<br />

BI-TONAL<br />

BI-TONAL<br />

1 2 3 4 5 6 7 8<br />

Also exists in<br />

SHADOW<br />

ver<strong>si</strong>on<br />

(see BASE SOUNDER)<br />

VIPER ADDRESSABLE SOUNDER - SPECIAL EDITION<br />

WEIGHT: 125 grams<br />

DIMENSIONS: DIAMETER: 100 - HEIGHT: 85 (mm)<br />

SOUND OUTPUT- CONTINUOUS85<br />

dB @ 1 METRE<br />

SOUND OUTPUT- SWEEP: 85 dB @ 1 METRE<br />

SOUND OUTPUT- ALTERNATING: 85 dB @ 1 METRE<br />

SOUND OUTPUT- HIGH PITCH: 92 dB @ 1 METRE<br />

VIPER ADDRESSABLE SOUNDER & BEACON<br />

X-VIPER BEACON<br />

This addressable sounder is a surface mountable unit available in red and white colors with very low power<br />

consumption as its main characteristic. It has a sound output of up to 92dBA with less than 5mA power<br />

consumption @ 24V. It is pos<strong>si</strong>ble to place up to 96 sounders or 64 sounder/beacons in a <strong>si</strong>ngle loop, 32 of which<br />

can be given a response address, the remaining being shadow sounders.<br />

Pr.Id.:32529<br />

STANDARD SHADOW<br />

SUPPLY VOLTAGE:<br />

17-40 V DC 17-40 V DC<br />

CURRENT CONSUMPTION QUIESCENT: 0.8 mA<br />

0.8 mA<br />

CURRENT CONSUMPTION ALARM:<br />

ADDRESS RANGE:<br />

3.5 mA<br />

3.5 mA<br />

94 - 125 (32/Loop) + SHADOW (64/Loop)<br />

TONES:<br />

4 TONES SELECTED BY DIL SWITCH<br />

PROTECTION RATING:<br />

IP65<br />

This addressable sounder is a surface mountable unit available in red and white colors with very low power<br />

consumption as its main characteristic. It has a sound output of up to 92dBA with less than 5mA power<br />

consumption @ 24V. It is pos<strong>si</strong>ble to place up to 96 sounders or 64 sounder/beacons in a <strong>si</strong>ngle loop, 32 of which<br />

can be given a response address, the remaining being shadow sounders.<br />

Pr.Id.:32531<br />

X-VIPER - A - SE<br />

SUPPLY VOLTAGE:<br />

17-40 V DC<br />

CURRENT CONSUMPTION QUIESCENT: 1 mA<br />

CURRENT CONSUMPTION ALARM: 4.5 mA<br />

ADDRESS RANGE:<br />

94 - 125 (32/Loop)<br />

TONES:<br />

4 TONES SELECTED BY JUMPERS<br />

PROTECTION RATING:<br />

IP44<br />

175 grams<br />

DIAMETER: 100 - HEIGHT: 70 (mm)<br />

1000Hz<br />

800 - 1200Hz<br />

1000 - 1300Hz<br />

2000 - 2600Hz<br />

This addressable sounder/beacon, is a surface mountable unit available in red color with very low power<br />

consumption as its main characteristic. It has a sound output of up to 92dBA with less than 5mA power<br />

consumption @ 24V. This includes a high power LED based beacon which uses 8 super-high efficiency RED<br />

LED's. It is pos<strong>si</strong>ble to place up to 96 sounders or 64 sounder/beacons in a <strong>si</strong>ngle loop, 32 of which can be<br />

given a response address, the remaining being shadow sounders. The beacon operation can be chosen<br />

between two modes:<br />

Mode A: The beacon operates <strong>si</strong>multaneously with the sounder and stops with the <strong>si</strong>lencing.<br />

Mode B: The beacon operates <strong>si</strong>multaneously with the sounder but does not stop flashing until the loop is<br />

12


X-VULCAN<br />

CHARACTERISTICS STANDARD SHADOW<br />

SUPPLY VOLTAGE:<br />

CURRENT CONSUMPTION QUIESCENT:<br />

CURRENT CONSUMPTION ALARM:<br />

ADDRESS RANGE:<br />

TONES:<br />

PROTECTION RATING:<br />

ADDRESSABLE SOUNDERS<br />

1 2 3 4 5 6 7 8<br />

ON<br />

OFF<br />

SWITCHES 1-5: REGULAR ADDRESSES FROM 094 TO 125 IN BINARY<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

Pr.Id.:32533<br />

PROGRAMMING DATA FOR ADDRESSABLE BASE SOUNDER<br />

17-40 V DC<br />

0.8 mA<br />

3.5 mA<br />

94 - 125 (32/Loop)<br />

SWITCH 6: OFF: IAS LOOP SOUNDER<br />

ON: APOLLO SOUNDER CIRCUIT CONTROLLER<br />

SWITCH 7 & 8: OFF: SWEEP SOUND (800 - 1000 Hz)<br />

SWITCH 7 ON & 8 OFF: ALTERNATE SOUND (2800 - 3500 Hz)<br />

SWITCH 7 OFF & 8 ON: ALTERNATE SOUND (800 - 1000 Hz)<br />

SWITCH 7 & 8: ON: CONTINUOUS (800 Hz)<br />

VULCAN ADDRESSABLE BASE SOUNDER Accepts APOLLO XP95 Detector Base.<br />

+<br />

17-40 V DC<br />

0.8 mA<br />

3.5 mA<br />

SHADOW (64/Loop)<br />

4 TONES SELECTED BY JUMPERS<br />

IP44<br />

1 2 3 4 5 6 7 8<br />

WEIGHT:<br />

75 grams<br />

DIMENSIONS:<br />

DIAM.: 112 - HEIGHT: 37 (mm)<br />

SOUND OUTPUT- CONTINUOUS 85 dB @ 1 METRE<br />

SOUND OUTPUT- SWEEP: 85 dB @ 1 METRE<br />

SOUND OUTPUT- ALTERNATING:<br />

SOUND OUTPUT- HIGH PITCH:<br />

85 dB @ 1 METRE<br />

92 dB @ 1 METRE<br />

This sounder is an ultra low power base sounder, intended to be used both as a stand-alone low profile<br />

sounder, or as a combined detector plus sounder assembly. When configured as a SHADOW sounder, by<br />

cutting the appropriate link, these sounders become invi<strong>si</strong>ble to the <strong>fire</strong> alarm control panel. This<br />

characteristic means that although the panel can control the activation of the sounders - in up to 32 groups per<br />

loop - each of these groups can have more than one and up to 64 sounders because the devices are not<br />

reporting back to the panel. This also means that device addresses 94 to 125, hereto reserved for<br />

addressable sounders, can be concurrently used by other device types, i.e. detectors and call points,<br />

meaning that at this stage the total numbers of sounders per loop is raised to 64 together with up to 125 other<br />

devices, detectors etc... This implies that the sounders are NOT monitored individually, but solely as part of<br />

the <strong>detection</strong> loop.<br />

13<br />

_<br />

_<br />

++ ++ _<br />

_<br />

X-VULCAN - A


SAM<br />

FEATURES<br />

Up to 125 SAM's can be connected to a loop<br />

SAM addresses are set by the test\commis<strong>si</strong>oning sequence<br />

SAM's can be fitted to the same loop as any of our addressable modules<br />

SAM's can be fitted to the same loop as S90, XP95 and Discovery detectors<br />

SAM addresses can be erased and re-programmed<br />

SOFT ADDRESSABLE MODULE<br />

Fully encased for protection in high impact plastic<br />

Small dimen<strong>si</strong>ons: 41.5 x 24.5 x 10.5 (mm)<br />

Connections compatible with fork terminals or wire up to 1.5 mm2<br />

Two ver<strong>si</strong>ons available: SAM-S for Smoke detectors<br />

SAM-H for Heat detectors<br />

Following strategy of providing competitive products for our esteemed customers, we are pleased to<br />

announce the launch of SAM. This tiny, very low cost, module provides any conventional detector with an<br />

address without the inconvenience of u<strong>si</strong>ng a manual addres<strong>si</strong>ng unit or DIP switch. The SAM is <strong>si</strong>mply<br />

attached to the conventional detector and the detector address is automatically as<strong>si</strong>gned to each SAM by the<br />

JUNO-NET or JUNiOr control panel during commis<strong>si</strong>oning and testing. A SAM based system tolerates loop<br />

branches and can monitor loop interruptions and head removal. SAM is ideal for low budget retrofits where<br />

<strong>fire</strong> point identification is needed but the cost of fitting a fully analogue system is too high. SAM is also an<br />

option in low budget installations that would normally be implemented with 4 to 8 zone conventional <strong>systems</strong>.<br />

It gives you the cable savings pos<strong>si</strong>ble (see below) with an addressable system, together with the loop<br />

sounder capability but without the extra costs of analogue addressable heads. Compatible with any make of<br />

conventional detector, the SAM is fully encapsulated in a plastic case, unobtru<strong>si</strong>ve and easy to connect to the<br />

detector base.<br />

3<br />

2<br />

Pr.Id.:32530<br />

CONVENTIONAL PANEL INSTALATION<br />

CABLE REQUIRED: METERS<br />

200<br />

5 6 7 8<br />

1<br />

4<br />

3<br />

SAME INSTALATION USING<br />

JUNO-NET PANEL & SAM SYSTEM<br />

CABLE REQUIRED: METERS<br />

78<br />

2<br />

4<br />

5 6 7 8<br />

A SAM system can prove economical as an alternative to conventional <strong>systems</strong> as small as 4 <strong>detection</strong><br />

zones. Up to 125 <strong>detection</strong> devices can be fitted to a <strong>si</strong>ngle loop of <strong>fire</strong>proof cable. This, together with the<br />

use of addressable loop powered sounders, keeps wiring costs to a minimum and gives the customer all the<br />

flexibility and programmability of an addressable system at an extremely competitive price.<br />

14<br />

1<br />

4


X-IN X-I/O<br />

X-IN<br />

ELECTRICAL CHARACTERISTICS<br />

ADDRESSABLE LOOP CURRENT<br />

LOOP CURRENT (NORMAL)<br />

LOOP CURRENT (O.C. FAULT)<br />

LOOP CURRENT (S.C. FAULT)<br />

LOOP CURRENT (FIRE)<br />

X-I/O<br />

Pr.Id.:32600<br />

ELECTRICAL CHARACTERISTICS<br />

ADDRESSABLE LOOP SUPPLY<br />

LOOP CURRENT (NORMAL)<br />

LOOP CURRENT (O.C. FAULT)<br />

LOOP CURRENT (S.C. FAULT)<br />

LOOP CURRENT (FIRE)<br />

LOOP CURRENT (RELAY ACTIVE)<br />

RELAY CONTACT RATING<br />

mA<br />

0,7<br />

0,7<br />

0,7<br />

3,1<br />

mA<br />

0,7<br />

0,7<br />

0,7<br />

3,1<br />

18,5<br />

50V 1A Re<strong>si</strong>stive<br />

ADDRESSABLE SINGLE INPUT UNIT<br />

MECHANICAL CHARACTERISTICS<br />

WEIGHT<br />

30 grams<br />

DIMENSIONS H: 20 W: 45 D: 53 (mm)<br />

WIRE CAPACITY<br />

2<br />

up to 2,5mm<br />

FIXINGS<br />

surface mount: 4 holes<br />

The INPUT UNIT is an addressable module, compatible with a ver<strong>si</strong>on of the meter bus protocol used by several<br />

panel manufacturers, which allows the connection of a normally open contact to an addressable <strong>fire</strong> <strong>detection</strong><br />

system.<br />

This is normally used to <strong>si</strong>gnal an alarm or fault <strong>si</strong>tuation in machinery or other alarm <strong>si</strong>tuations like flooding, etc...,<br />

by means of Fire <strong>detection</strong> system.<br />

The module is supplied from the <strong>detection</strong> loop and monitors the connection to the monitored switch. This is done<br />

by placing a 22 K ohm E.O.L. at the connections end and connecting a 4K7 re<strong>si</strong>stor in series with the alarm switch.<br />

The input status is visualized locally by a red LED, where the red light <strong>si</strong>gnals an alarm condition.<br />

The INPUT unit is available as an electronic module with four fixing holes, or as a boxed unit for individual module<br />

installations. The module detects and reacts to four bands of re<strong>si</strong>stance between its input terminals, which are as<br />

follows:<br />

OPEN TO 50K - FAULT REPORTED 50K TO 8K2 - NORMAL REPORTED 8K2 TO 2K2 - FIRE REPORTED 2K2 TO 0R0 - FAULT REPORTED<br />

Pr.Id.:32510<br />

ADDRESSABLE SINGLE INPUT/OUTPUT UNIT<br />

MECHANICAL CHARACTERISTICS<br />

WEIGHT<br />

30 grams<br />

DIMENSIONS H: 15 W: 52 D: 57 (mm)<br />

WIRE CAPACITY<br />

2<br />

up to 2,5mm<br />

FIXINGS<br />

surface mount: 4 holes<br />

The I/O-ISO is an addressable module, compatible with a ver<strong>si</strong>on of the meter bus protocol used by several panel<br />

manufacturers, which allows the connection of a normally open contact to an addressable <strong>fire</strong> <strong>detection</strong> system,<br />

providing at the same time an output relay contact to control ancillary equipment.<br />

This is normally used to <strong>si</strong>gnal alarm or fault <strong>si</strong>tuations in machinery or other alarm <strong>si</strong>tuations like flooding etc...,<br />

and controlling ancillary equipment, by means of the Fire <strong>detection</strong> system.<br />

The module is supplied from the <strong>detection</strong> loop and monitors the monitored switch. This is done by placing a 22K<br />

ohms E.O.L. re<strong>si</strong>stors at the connections ends and wiring a 4K7 re<strong>si</strong>stor in series with the alarm switch.<br />

The input status is visualized locally by a red LED, where the red light <strong>si</strong>gnals an alarm condition.<br />

The relay operation is <strong>si</strong>gnaled by a yellow LED which lights when the relay is actuated.<br />

The power for actuating the relay can be external or drawn from the <strong>detection</strong> loop. The choice is made by shorting<br />

two pads on the solder <strong>si</strong>de of the PCB for loop power, or leaving those open if an external supply is available. By<br />

default, the unit is prepared for loop power. The external supply is optically isolated from the <strong>detection</strong> loop. The<br />

I/O-ISO is available as an electronic module with four fixing holes, or as a boxed unit for individual module<br />

installations. The module detects and reacts to four bands of re<strong>si</strong>stance between its input terminals, which are as<br />

follows:<br />

OPEN TO 50K - FAULT REPORTED 50K TO 8K2 - NORMAL REPORTED 8K2 TO 2K2 - FIRE REPORTED 2K2 TO 0R0 - FAULT REPORTED<br />

15


X-I/O3 X-I/O8<br />

X-I/03<br />

ELECTRICAL CHARACTERISTICS<br />

ADDRESSABLE LOOP SUPPLY<br />

LOOP CURRENT (NORMAL)<br />

LOOP CURRENT (O.C. FAULT)<br />

LOOP CURRENT (S.C. FAULT)<br />

LOOP CURRENT (FIRE)<br />

RELAY CONTACT RATING<br />

ADDRESSABLE TRIPLE INPUT / OUTPUT UNIT<br />

The 3 I/O-ISO is an addressable module, compatible with a ver<strong>si</strong>on of the Meter bus protocol used by several panel<br />

manufacturers, which allows the connection of three normally open contacts to an addressable <strong>fire</strong> <strong>detection</strong><br />

system, providing at the same time three output relay contacts to control ancillary equipment. This is normally<br />

used to <strong>si</strong>gnal alarm or fault <strong>si</strong>tuations in machinery or other alarm <strong>si</strong>tuations like flooding etc..., and controlling<br />

ancillary equipment, by means of the Fire <strong>detection</strong> system. The module is supplied from the <strong>detection</strong> loop and<br />

monitors the connection to the monitored switches. This is done by placing a 22K ohms E.O.L. re<strong>si</strong>stors at the<br />

connections ends and wiring a 4K7 re<strong>si</strong>stor in series with the alarm switches. The input status is visualized locally<br />

by three red LED's which <strong>si</strong>gnal a <strong>fire</strong> condition at the inputs, and a yellow common fault LED. The relay operation<br />

is <strong>si</strong>gnaled by three red LEDs which light when the respective relays are actuated. The power for actuating the<br />

relays is derived from an external P.S.U. The external supply is optically isolated from the <strong>detection</strong> loop. The 3<br />

I/O-ISO is available as an electronic module with four fixing holes. The module detects and reacts to four bands of<br />

re<strong>si</strong>stance between its input terminals, which are as follows:<br />

X-I/O8<br />

Pr.Id.:32527<br />

mA<br />

0,7<br />

3,1<br />

3,1<br />

ELECTRICAL CHARACTERISTICS<br />

ADDRESSABLE LOOP CURRENT<br />

LOOP CURRENT (NORMAL): 0.7 mA<br />

RELAY CONTACT RATING: 50V 1A RESISTIVE<br />

3,1<br />

50V 1A Re<strong>si</strong>stive<br />

MECHANICAL CHARACTERISTICS<br />

WEIGHT<br />

80 grams<br />

DIMENSIONS H: 20 W: 72 D: 88 (mm)<br />

WIRE CAPACITY<br />

2<br />

up to 2,5mm<br />

FIXINGS<br />

surface mount: 4 holes<br />

OPEN TO 50K - FAULT REPORTED 50K TO 8K2 - NORMAL REPORTED 8K2 TO 2K2 - FIRE REPORTED 2K2 TO 0R0 - FAULT REPORTED<br />

Pr.Id.:32601<br />

ADDRESSABLE 8 INPUT / 2 OUTPUT UNIT<br />

MECHANICAL CHARACTERISTICS<br />

WEIGHT<br />

60 grams<br />

DIMENSIONS H: 20 W: 88 D: 74 (mm)<br />

WIRE CAPACITY<br />

2<br />

up to 2,5mm<br />

FIXINGS<br />

surface mount: 4 holes<br />

The 8 I/O module is an addressable module, compatible with a ver<strong>si</strong>on of the meter bus protocol used by several<br />

panel manufacturers, which allows the connection of eight normally open contacts to an addressable <strong>fire</strong> <strong>detection</strong><br />

system, providing at the same time two output relay contacts to control a conventional <strong>fire</strong> alarm panel.<br />

This module will normally be used to interface existing conventional <strong>fire</strong> alarm <strong>systems</strong> to an analogue<br />

addressable <strong>fire</strong> control panel. The module is supplied from the <strong>detection</strong> loop but requires a nominal 24V DC<br />

supply for relay energizing. This auxiliary supply can be derived from the conventional <strong>fire</strong> alarm panel. The alarm<br />

<strong>si</strong>lencing and reset functions of the conventional <strong>fire</strong> alarm panel can be executed by <strong>si</strong>lencing and resetting the<br />

analogue addressable <strong>fire</strong> control panel. The 8 inputs are digital normally open inputs that can be connected to the<br />

zone repeater outputs of the conventional <strong>fire</strong> alarm panel. The <strong>si</strong>lence and reset relay operation is <strong>si</strong>gnaled by<br />

two green LEDs. The external supply is optically isolated from the <strong>detection</strong> loop.<br />

16


X-<br />

X-LSCISO<br />

TECHNICAL CHARACTERISTICS<br />

WORKING VOLTAGE:<br />

QUIESCENT CURRENT CONSUMPTION:<br />

ALARM CURRENT CONSUMPTION:<br />

OPERATING TEMPERATURE:<br />

HUMIDITY:<br />

X-LSCM<br />

Pr.Id.:32602<br />

TECHNICAL CHARACTERISTICS<br />

LOOP SOUNDER CONTROL MODULE WITH 1 AMP MONITORED OUTPUT<br />

EXTERNAL SUPPLY<br />

WORKING VOLTAGE:<br />

QUIESCENT CURRENT CONSUMPTION:<br />

ALARM CURRENT CONSUMPTION:<br />

ISOLATION:<br />

DIMENSIONS:<br />

WEIGHT:<br />

LOOP SOUNDER CONTROL MODULE<br />

30 - 95% NON-CONDENSING<br />

H: 16 W: 37 D: 31 (mm)<br />

15 grams<br />

12 - 30 Volts DC<br />

1.9mA max..<br />

1A max.<br />

500 Volts DC/max.<br />

H: 19 W: 48 D: 58 (mm)<br />

30 grams<br />

The LSC-ISO is an externally powered sounder control module, de<strong>si</strong>gned mechanically to be mounted in<strong>si</strong>de a<br />

standard module box The main feature of this module is its capability to drive and monitor a bell output with a<br />

maximum output of 1A. The wiring to the sounders is monitored for short and open circuit in quiescent mode<br />

requiring a <strong>si</strong>ngle 10K ohm re<strong>si</strong>stor to be placed at the end of the monitored line. A <strong>si</strong>x way DIL switch of which only<br />

the first five sections are used allows programming of addresses 94 to 125. The output of the module is by a two<br />

way terminal block where the line of conventional sounders is connected. The output can either be pulsed or<br />

continuous. The protocol used by the LSC-ISO is only compatible with GFE's range of panels. A maximum<br />

number of 32 modules can be connected to each addressable loop. The current derived to the sounder output is<br />

limited to 1A which protects the output from overloading if the output is accidentally shorted. When the line<br />

monitored is correctly terminated by a 10K ohm re<strong>si</strong>stor an analogue value of 16 is returned upon interrogation of<br />

the device. If the sounder line is either interrupted or short circuited at any point, a fault value of 4 is returned.<br />

When in alarm, the analogue value reported by the device is always 17. This <strong>si</strong>gnals to the control panel that the<br />

sounder controller has responded to its activation command.<br />

Pr.Id.:32603<br />

WORKING VOLTAGE:<br />

QUIESCENT CURRENT CONSUMPTION:<br />

ALARM CURRENT CONSUMPTION:<br />

OPERATING TEMPERATURE:<br />

17-40 VOLTS DC<br />

750uA MAX.<br />

1.5mA MAX.<br />

0 - 85°C<br />

30 - 95% NON-CONDENSING<br />

17-40 VOLTS DC<br />

330uA MAX.<br />

40mA MAX. (load dependent)<br />

0 - 85°C<br />

HUMIDITY:<br />

DIMENSIONS:<br />

WEIGHT:<br />

The LSCM1 is a loop powered sounder control module, de<strong>si</strong>gned mechanically to be mounted in<strong>si</strong>de any<br />

conventional sounder or beacon with up to 40mA consumption. The main features of this module are its low<br />

power consumption in quiescent mode and its electronic and mechanical <strong>si</strong>mplicity which make it a reliable<br />

and economical piece of equipment. A <strong>si</strong>x way DIL switch allows as<strong>si</strong>gning of the address pertaining to each<br />

sounder, in the range from 94 to 125. The first five switches define this address, where an "all off" setting<br />

corresponds to address 94. Switch #6 defines the operation mode of the module; If this switch is OFF, the<br />

module responds as an GFE sounder controller, if it is in the ON po<strong>si</strong>tion, its operation will be equivalent to an<br />

Apollo Sounder Circuit Controller. The output of the module is by two leads that are <strong>si</strong>mply connected to the<br />

terminals of the sounder or beacon which are relevant. The output can either be pulsed or continuous. The<br />

protocol used by the LSCM1 is only compatible with GFE's range of panels. When exposed to a XP95<br />

interrogation format the module just continues its power management function without disturbing the<br />

communication of other XP95 devices in the loop. The current derived to the sounder output is limited to<br />

40mA which protects the loop from overloading if the output is accidentally shorted. When a sounder is<br />

connected to the module's output an analogue value of 16 is returned upon interrogation of the device. If no<br />

connection is made to the output, a fault value of 4 is returned. When in alarm, the analogue value reported by<br />

the device is always 17. This <strong>si</strong>gnals to the control panel that the sounder controller has responded to its<br />

activation command.<br />

17<br />

X-LSCM


X-ZMU X-ZMU4<br />

X-ZMU<br />

ELECTRICAL CHARACTERISTICS<br />

ADDRESSABLE LOOP SIDE mA<br />

LOOP CURRENT (NORMAL) 2,9<br />

LOOP CURRENT (O.C. FAULT) 1,5<br />

LOOP CURRENT (S.C.FAULT) 1,5<br />

LOOP CURRENT (FIRE) 3,1<br />

X-ZMU4<br />

Pr.Id.:32511<br />

EXTERNAL SUPPLY SIDE<br />

SUPPLY CURRENT (NORMAL)<br />

SUPPLY CURRENT (O.C. FAULT)<br />

SUPPLY CURRENT (S.C.FAULT)<br />

SUPPLY CURRENT (FIRE)<br />

ZONE MONITORING UNIT<br />

The ZMU is an addressable module, compatible with a ver<strong>si</strong>on of the meter bus protocol used by several panel<br />

manufacturers, and which allows the connection of a number of conventional smoke or heat detectors and manual<br />

call-points, to an addressable <strong>fire</strong> <strong>detection</strong> system. This means that from a <strong>detection</strong> and alarm proces<strong>si</strong>ng point<br />

of view, that group of <strong>detection</strong> devices is given an address and con<strong>si</strong>dered as an unique alarm source. U<strong>si</strong>ng this<br />

module is a natural option in the protection of large areas, like underground parking lots, where the expense of<br />

u<strong>si</strong>ng addressable detectors is not justifiable, even though the configuration of the rest of the building requires<br />

those. This module can draw its power from the communication loop which dispenses with the need for an<br />

additional power supply connection, or be supplied from an external power supply unit. This is defined by<br />

removing the two jumpers installed as a default. The unit controls a zone of conventional detectors with a 4K7 ohm<br />

pas<strong>si</strong>ve E.O.L. Because the current drawn from the loop can be <strong>si</strong>gnificant, especially in Fire and S.C. Fault<br />

conditions, the number of modules that can be supplied is limited. The current status is visualized locally by a dual<br />

color LED, where the green light means a normal current condition, a red light <strong>si</strong>gnals a <strong>fire</strong> condition and no light<br />

indicates a fault. The unit monitors the external power supply, reporting a fault if the auxiliary power is not present.<br />

The ZMU is available as an electronic module with four fixing holes, or as a boxed unit for individual module<br />

installations. The module detects and reacts to four bands of zone current which are interpreted and <strong>si</strong>gnaled to<br />

the control panel and which are as follows:<br />

0 TO NORMAL - FAULT REPORTED NORMAL TO ALARM - NORMAL REPORTED ALARM TO SHORT CCT - FIRE REPORTED SHORT CCT - FAULT REPORTED<br />

Pr.Id.:32528<br />

ELECTRICAL CHARACTERISTICS<br />

ADDRESSABLE LOOP SIDE mA<br />

LOOP CURRENT (NORMAL) 1,5<br />

LOOP CURRENT (O.C. FAULT) 1,5<br />

LOOP CURRENT (S.C.FAULT) 1,5<br />

LOOP CURRENT (FIRE) 1,5<br />

EXTERNAL SUPPLY SIDE mA<br />

SUPPLY CURRENT (NORMAL) 7 / CCT<br />

SUPPLY CURRENT (O.C. FAULT) 1,5 / CCT<br />

SUPPLY CURRENT (S.C.FAULT) 60 / CCT<br />

SUPPLY CURRENT (FIRE) 30 / CCT<br />

0 TO NORMAL - FAULT REPORTED NORMAL TO ALARM - NORMAL REPORTED ALARM TO SHORT CCT - FIRE REPORTED SHORT CCT - FAULT REPORTED<br />

mA<br />

7<br />

1,5<br />

60<br />

30<br />

MECHANICAL CHARACTERISTICS<br />

WEIGHT 30 grams<br />

DIMENSIONS H: 20 W: 60 D: 60 (mm)<br />

2<br />

WIRE CAPACITYUP<br />

TO 2,5 mm<br />

ADDRESSABLE 4 ZONE MONITOR UNIT EXTERNALLY POWERED<br />

MECHANICAL CHARACTERISTICS<br />

WEIGHT 130 grams<br />

DIMENSIONS H: 20 W: 75 D: 148 (mm)<br />

2<br />

WIRE CAPACITYUP<br />

TO 2,5 mm<br />

The QUAD-ZMU is an addressable module, compatible with a ver<strong>si</strong>on of the meter bus protocol used by several<br />

panel manufacturers, and which allows the connection of four zones with a number of conventional smoke or heat<br />

detectors and manual call-points, to an addressable <strong>fire</strong> <strong>detection</strong> system, u<strong>si</strong>ng four consecutive addresses. This<br />

means that from a <strong>detection</strong> and alarm proces<strong>si</strong>ng point of view, each group of <strong>detection</strong> devices is given an<br />

address and con<strong>si</strong>dered as an unique alarm source. U<strong>si</strong>ng this module is a natural option in the protection of large<br />

areas, like underground parking lots, where the expense of u<strong>si</strong>ng addressable detectors is not justifiable, even<br />

though the configuration of the rest of the building requires those. This module requires the connection of 24V DC<br />

supply which is permanently monitored and allows the connection of four standard zones of detectors with 4K7<br />

ohm pas<strong>si</strong>ve E.O.L. The <strong>detection</strong> zones and their supply voltage are optically isolated from the addressable<br />

<strong>detection</strong> loop, which allows the use of a local independent power supply. If that supply fails, a FAULT condition is<br />

reported to the control panel. The current status of each zone is visualized locally by two LED’s, where the yellow<br />

light means a fault condition and a red light <strong>si</strong>gnals a <strong>fire</strong> condition and no light indicates a normal <strong>si</strong>tuation. A green<br />

LED indicates that there is power on the zone connections. The individual zones of this module detect and react to<br />

four bands of zone current which are interpreted and <strong>si</strong>gnaled to the control panel and are as follows:<br />

18


X-IND<br />

CHARACTERISTICS<br />

WORKING VOLTAGE RANGE:<br />

CURRENT CONSUMPTION:<br />

This remote indicator can be used with any <strong>fire</strong> alarm detector, be it of<br />

the conventional or addressable/analogue types, to indicate<br />

remotely the activation of the relevant <strong>detection</strong> device. It’s main<br />

characteristics are the high vi<strong>si</strong>bility due to the alternate blinking of<br />

two high efficiency LED’s (“A” Ver<strong>si</strong>on), and the wide operating<br />

voltage range 3 to 15 DC Volts, with a minimum of 300 µ A current<br />

consumption. The two connections of this device are non-polarized,<br />

avoiding wasted time at the installation phase. The unit comes<br />

complete with a face plate compatible with standard flush mounting<br />

boxes.<br />

JUNCTION BOX<br />

485 INT<br />

CHARACTERISTICS<br />

SUPPLY VOLTAGE:<br />

OPERATING CURRENT:<br />

MAX BAUD RATE:<br />

Pr.Id.:32521<br />

3 - 15 V DC<br />

300 µA - 15 mA<br />

Pr.Id.:32604<br />

Our ABS molded multi purpose<br />

junction box is provided in RED or<br />

WHITE color with matching snap-on<br />

cover and has four mounting holes<br />

compatible with our <strong>si</strong>ngle channel<br />

addressable modules. It is intended<br />

for surface use but can also be<br />

embedded.<br />

Weight with cover: 74 grams.<br />

Pr.Id.:32605<br />

20-30V.<br />

25mA max.<br />

9600 baud<br />

FLASHING REMOTE INDICATOR<br />

DIMENSIONS: FACE PLATE<br />

DIMENSIONS: INDICATOR:<br />

WEIGHT:<br />

DIMENSIONS:<br />

This optically isolated converter can be used to connect RS232<br />

<strong>si</strong>gnaling equipment over distances up to 1200 m. It is mainly<br />

used in conjunction with the JUNO panels and repeaters.<br />

ACCESSORIES<br />

76 x 76 x 2 (mm)<br />

68 x 33 x 25 (mm)<br />

ABS MULTI PURPOSE JUNCTION BOX<br />

19<br />

RS232/RS485 CONVERTER<br />

44 grams<br />

H: 51 W: 101 D: 16 (mm)


CONVENTIONAL DETECTORS<br />

S-T Series<br />

�Product Features:<br />

�4 wire models<br />

�Dual LEDs for 360°vi<strong>si</strong>bility<br />

�Advanced <strong>detection</strong> and discrimination algorithms<br />

�Easy installation and maintenance<br />

�Sleek low-profile hou<strong>si</strong>ng de<strong>si</strong>gn<br />

�Durable sensor head, no need for replacement<br />

�SMD circuit board de<strong>si</strong>gn-satisfactory quality and<br />

reliability guaranteed<br />

�Integrated heat detector for S-T models<br />

�Five-year limited warranty<br />

�N/C (normal/close)-N/O (normal/open)selectable relay<br />

output<br />

�AR (Auto Reset) function for security <strong>systems</strong><br />

�(optional for 4 wire models)<br />

�Sensor base option: standard and Shottky Diode<br />

S-O Series<br />

�4 wire models<br />

�Dual LEDs for 360°vi<strong>si</strong>bility<br />

�Advanced <strong>detection</strong> and discrimination algorithms<br />

�Easy installation and maintenance<br />

�Sleek low-profile hou<strong>si</strong>ng de<strong>si</strong>gn<br />

�Durable sensor head, no need for replacement<br />

�SMD circuit board de<strong>si</strong>gn-satisfactory quality and<br />

reliability guaranteed<br />

�Remote LED<br />

�Five-year limited warranty<br />

�N/C (normal/close)-N/O (normal/open)selectable relay<br />

output<br />

�AR (Auto Reset) function for security <strong>systems</strong><br />

�(optional for 4 wire models)<br />

�Sensor base option: standard and Shottky Diode<br />

Pr.Id.:32541 Pr.Id.:32540<br />

Model S-O S-T<br />

2/4 Wire 4 4<br />

Thermal / Optical Optical Thermal / 57�C<br />

Voltage DC 10-15V 10,2-13,8V<br />

Standby Current (Max) 55�A 370�A<br />

Alarm Current (Max) 50mA 35mA<br />

Surge Current (Max) 150�A<br />

Start-Up Time (Max) 60sec 120sec<br />

Permis<strong>si</strong>ble Current (Max) 80mA<br />

80mA<br />

Frequency 4-6sec 3-5sec<br />

Base Model S-B S-B<br />

20


ACCESSORIES, GAS DETECTORS<br />

Air Sampling Unit Pr.Id.:32502<br />

B-IC Air sampling unit is de<strong>si</strong>gned for use with Firex series smoke<br />

detectors.The unit enables smoke detectors to be <strong>si</strong>ted within<br />

ventilation extract ducts in order to as<strong>si</strong>st in the prevention of the<br />

spread of smoke by the ventilation system.<br />

BL-151 Relay Adapter Pr.Id.:32501<br />

Relay adapter that allows connection of conventional <strong>fire</strong> detectors<br />

to the ergular alarm system.<br />

General features are:<br />

Free switching for alarm <strong>si</strong>gnalling.<br />

Pree switching for fault <strong>si</strong>gnalling<br />

Detector line reset button<br />

Connect from 7-10 detectors to one BL-151<br />

Electro - magnetic door holder<br />

Electromagnetic door holder type 1340 and 1360.<br />

Features:<br />

1340 Type: 100kg Pr.Id.:32506<br />

1360 Type: 100kg with hou<strong>si</strong>ng and release key<br />

G55 Series Gas Detectors<br />

The G55 series gas detectors include detectors for following gases:<br />

methane, butane, gasoline fumes, CO (carbon monoxinde),<br />

hydrogen, propane.<br />

Please check with your distributor which type of detector you need.<br />

B55 Series Sample Gases<br />

In order to set the G55 detectors optimally you will need to<br />

purchase and use the B55 Sample Gas. Each detector type<br />

requires affiliate gas.<br />

Conventional <strong>fire</strong> <strong>si</strong>rens and flashing lights<br />

We are offering you a wide variety of audible, visual and visualaudible<br />

annunciators.<br />

Some features:<br />

Type SP-30; audible addres<strong>si</strong>ble annunciator<br />

Type Solo/24; visual - audible outdoor annunciator with 4 ohms at<br />

117dB@1m<br />

1484; flashing light 12/24Vdc<br />

21<br />

Pr.Id.:32604<br />

Pr.Id.:32507