Troubleshooting ChartTROUBLE CAUSE REMEDYDryer does not stop at endof time period (6).Dryer runs no steam tocoils.Water in steam line.Basket does not reverse.Defective timer.Valve closed.Steam trap blocked.Solenoid valve.Thermostat.Check valve installedincorrectly.Strainer clogged.Steam pipinginstalled incorrectly.Trap not functioning.Reversing timer.Replace timer.Check all valves in steam supply and return. Makesure they are open.Remove and clean. Replace if defective.On dryers using solenoid temperature control, thermostatcontrols operation of solenoid valve by advancingthermostat.On dryers using solenoid temperature control, thermostatcontrols operation of solenoid valve. If defective,replace thermostat.Check for inlet and outlet marking on check valve andinvert if necessary.Remove plug and blow down strainer or remove andclean thoroughly if heavily clogged.Check piping per steam installation instructions.Check trap for size and capacity. If dirty and sluggish,clean thoroughly or replace. Check return linefor high back pressure, or another trap chargingagainst the trap functioning improperly.Check timer to see if operating.Page 41