Specifications:Unit 5000 <strong>6000</strong> 70002 Gatton Park Business CentreWells Place, RedhillSurrey RH1 3LGt: +44 (0) 1737 649300f: +44 (0) 1737 649301e: info@h-pi.co.ukTarget Type Bowl Bowl FlatTarget Distance 25 Cm 25 Cm 17CmMaximum stimulus Illumination 1000 cd/m2 1000 cd/m2 100 cd/m2Background Illumination 3.15 cd/m2 3.15 cd/m2 3.15 cd/m2(10asb) (10asb) (10asb)Tinsley, which was founded in 1904, is now part of the Hartest Precision Instruments group and has been supplyingspecialist instruments for over 50 years. It is a market leader in field of vision analysers and a long-standing supplierto the Moorfields Eye Hospital.Henson Field of Vision AnalysersStimulii LEDs with Broad LEDs LEDsspectrum Output White White540 -590nmAngular Subtense 0.5º (Goldmann III) 0.5º (Goldmann III) 0.5º (Goldmann III)Presentation time 200mS 200mS 200mSFixation targetsFixation Monitor......................................Red LED or Cross Pattern of LEDS..............................................................Heijl-Krakau technique in Full threshold programmes......................Video CCD camera for <strong>6000</strong>+ has on screenoptional on screen video video fixation monitoringChinrestHeight adjustableHeadrest Fixed Fixed Eyepiece onlyTest StratagiesCentral 30º ✓ ✓ ✓Full Field 60º✓Supra threshold- Multiple (points) 26, 64, 128 26, 64,128 26, 64- Single (points) 26, 64, 128 26, 64, 128 26, 64- Multi Sampling ✓ ✓Full & Fast Threshold 24/2, 30/2 & 60/2 24/2 & 30/2 24/2 & 30/2Estermann- Binocular ✓ ✓- Monocular ✓ ✓Control Device External PC Internal PC External PC/Laptop*Connections Dependant on 2 x USB Dependant onExternal PC/Laptop VGA Monitor External PC/LaptopRJ45 EthernetDimensions (mm) L600 x D400 x H620 L580 x D460 x H430 L300 x D260 x H340Weight 18Kg 14.5kg 5kgMainsFrequency..........................................84 to 264V AC Universal Input....................................................................................................45-65Hz...........................................................Power 250W 250W 80WFuses T1A 180-240v. T1.6A 90-132vClassificationMains operated. Class I. Type B*The Henson 7000 is also available with optional extra intuituve touch screen custom controller unitHensonPro 5000CE ApprovedHenson Compact<strong>6000</strong>/<strong>6000</strong>+CE and FDA ApprovedHenson 7000CE and FDA ApprovedFor more information about the Hartest group visit:www.h-pi.co.ukHensonPro 5000Henson Compact <strong>6000</strong>/<strong>6000</strong>+Henson Compact 7000


5000HensonPro 5000 Field AnalyserThe design and development of theHenson Pro 5000 was based on theexperiences and feedback fromhundreds of existing Henson users.The clinically proven bowl designpermits full field screening with a smallphysical size.The Pro 5000 operates from either alaptop or Personal Computer and thesoftware is the latest development ofwhat is already acknowledged as beingone of the world’s leading visual fieldpackages.Whatever your visual fieldsrequirements, from simple routinescreening to long term visual field lossmonitoring, the quality and performanceof the Henson Pro 5000 has beendesigned for all your testing needs.Complete your visual field screening in under 2 minutesper eye.Fully automated testing strategies provide speed withoutcompromising accuracy.Clinically proven and accepted design.Drivers tests which conform to UK DVLA standards included.Multi sampling test for improved glaucoma patient fieldmonitoring.Optional on screen fixation monitor improves resultsconfidence.Choice of either laptop or desktop PC.Estermann monocular and binocular testing.C.E Approved.<strong>6000</strong>/<strong>6000</strong>+Henson Compact <strong>6000</strong>/<strong>6000</strong>+ Field AnalyserEverything from a quick multistimulus glaucoma screen to a fullthreshold central field and UK DVLAdriver test to an eccentricity of 72degrees. Featuring both monocularand binocular Esterman test theHenson <strong>6000</strong> is a great package.Size, ease of use, performance andspeed of operation have all influencedits design.The Henson <strong>6000</strong> has been designedto enable networking on a standardwindows platform.Important clinical considerations havebeen incorporated such as a newthreshold algorithm which enhancesthe reliability and reproducibility ofthreshold levels together with automaticmeasurement of patient response time.These two factors are now believedto have important significance in thereliable detection and monitoring ofglaucoma conditions.Whatever your visual field requirements,from quick routine screening to longerterm monitoring, the Henson Compact<strong>6000</strong> has been designed to meet therequirements in a compact and easy touse screener.The Henson Compact <strong>6000</strong>+ unitincludes a built in camera for on screenfixation monitoring.Complete your visual field screening in under 2 minutesper eye.7000Henson 7000 Field AnalyserThe Henson 7000 analyser waslaunched in response to requestsfor a smaller footprint screener thatcould be integrated with existingcomputer networks.With space at a premium in manyPractices, there is rising demand forfast, accurate vision screening forGlaucoma in a small, portable package.It can be used at home or by a hospitalbedside and, despite its diminutive size,the 7000 can perform all central fieldtests.The Henson weighs just 5kg and alsoincorporates the new algorithm forimproving the detection and monitoringof Glaucoma featured in the <strong>6000</strong>.A visual field screening test takes aslittle as two minutes with this device andthe processes are fully automated.The Henson 7000 has an optional extraof its own custom-made touch screencontrol unit or can be used indirectlyfrom a standard laptop or PC.Complete your visual field screening in under 2 minutesper eye.Fully automated testing strategies provide speed withoutcompromising accuracy.Control using a standard laptop computer/PC.Improved supra threshold routine for more repeatable results.Portable unit for domiciliary use.Monitorised adjustable patient unit for patient comfort &convenience.Optional extra custom controller unit.C.E and FDA Approved.Fully automated testing strategies provide speed withoutcompromising accuracy.Clinically proven and accepted design.Drivers tests which conform to UK DVLA standards included.Multi sampling test for improved glaucoma patient fieldmonitoring.Custom controller unitOptional on screen fixation monitor improves results confidence.Ethernet connections.Estermann monocular and binocular testing.C.E and FDA Approved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!