22.08.2015 Views

Technical data SIH 40TE

Technical data SIH 40TE - siltumsukni.lv

Technical data SIH 40TE - siltumsukni.lv

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Technical</strong> <strong>data</strong> <strong>SIH</strong> <strong>40TE</strong>High temperature brine-to-water heat pumpsDevice information<strong>SIH</strong> <strong>40TE</strong>Design- Heat source Brine- Model Universal design- Regulation WPM 2007, integrated- Installation location Indoors- Performance levels 2Operating limits- Max. flow temperature 7) 70 °C +- 2- Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation) -5 / 25 °C- Antifreeze Monoethylenglycol- Brine concentration 25 %Flow / sound- Max. heating water flow rate / Pressure drop 5,5 m³/h / 2900 Pa- Minimum heating water flow rate / Pressure drop 3,2 m³/h / 1100 Pa- Heat source flow (min.) / Pressure drop evaporator EN 14511 11 m³/h / 7800 Pa- Sound power level device 65 dB (A)- Sound pressure level in 1 m (indoors) 2) 50 dB (A)Dimensions/weight and filling quantities- Dimensions (W x H x D) 3) 1350 x 1890 x 775 mm- Weight 502 kg- Thread type, heating connection / Connection heating G / 1 ½ inch- Thread type, heat source connection / Heat source connection G / 2 ½ inch- Refrigerant / Amount of refrigerant R134a / 8 kg- Oil type / Oil quantity Polyolester (POE) / 6,5 lElectrical connection- Connection voltage / Fuse protection 3/N/PE ~400 V, 50 Hz / C 50 A- Control voltage / Control voltage fuse protection 1/N/PE ~230 V, 50 Hz / C 16 A- Degree of protection IP 21- Initial current limiter Yes- Starting current with soft starter 84 A- Nominal power consumption according to EN 14511 at B0/W35 1) 8,35 kW- Nominal current at B0/W35 / Nominal current cos phi 15,06 A / 0,8- Power consumption of the compressor protection 65 WComplies with the European safety regulationsAdditional model features- Water in device protected against freezing 4) YesWarmwasserspeicherHeat output / coefficient of performance (COP) according to EN14511: 1)Heating compressor 1 W35 W45 W55B-5 13,56 kW / 3,28 10,76 kW / 1,97 kW /B0 17,9 kW / 4,3 12,9 kW / 2,5 kW /B5 21,43 kW / 5,08 17,24 kW / 3,14 kW /B10 24,5 kW / 5,7 20,35 kW / 3,69 kW /B25 34,29 kW / 7,71 30,64 kW / 5,44 kW /Heating compressor 2 W35 W45 W55B-5 28,16 kW / 3,48 27,93 kW / 2,86 kW /B0 34,2 kW / 4,1 31,7 kW / 3,2 kW /B5 39,32 kW / 4,62 36,71 kW / 3,62 kW /B10 45,17 kW / 5,1 42,6 kW / 4,19 kW /B25 62,35 kW / 6,76 61,07 kW / 5,66 kW /Note:1) These <strong>data</strong> indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and regulation should betaken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, commissioning and operation can be found in the respectivesections of the installation and operating instructions. The specified values have the following meaning, e.g. A7 / W35: Heat source temperature 7 °C and heating water flow temperature 35 °C.2) The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C. The specified sound pressure level represents thefree sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.3) Please note that additional space is required for pipe connections, operation and maintenance.4) The heat circulating pump and the heat pump controller must always be ready for operation.7) Depending on the type of heat pump and refrigerant, the maximum flow temperatures in heating mode may decline with lower external temperatures. Further information can be found in the heatpump's operating limits diagram.Glen Dimplex Deutschland GmbHDimplex divisionAm Goldenen Feld 1895326 KulmbachPage 1/3Errors and omissions excepted!E-Mail: info@dimplex.deInternet: www.dimplex.dePrint date: 08.06.2012Telephone: +49 (0)9221 709-562Fax: +49 (0)9221 709-565


Heating characteristic <strong>SIH</strong> <strong>40TE</strong>High temperature brine-to-water heat pumpsHeat output in [kW]Water outlet temperature in [°C]Operation with 2 compressorsOperation with 1 compressorConditions:Minimum heating water flow rate 3,2 m³/hHeat source flow (min.) 11, m³/hHeat source inlet temperature [°C]Power consumption (incl. proportion of pump output)Pressure drop in [Pa]EvaporatorHeat source inlet temperature [°C]Brine flow rate in [m³/h]Coefficient of performance (incl. proportion of pump output)Pressure drop in [Pa]LiquefierHeat source inlet temperature [°C]Heating water flow rate in [m³/h]Glen Dimplex Deutschland GmbHDimplex divisionAm Goldenen Feld 1895326 KulmbachPage 2/3Errors and omissions excepted!E-Mail: info@dimplex.deInternet: www.dimplex.dePrint date: 08.06.2012Telephone: +49 (0)9221 709-562Fax: +49 (0)9221 709-565


Operating limits diagram <strong>SIH</strong> <strong>40TE</strong>High temperature brine-to-water heat pumpsHeating water temperature [°C]75706560555045403530252015-30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45Heat source inlet temperature [°C]Note:The maximum possible flow temperature and the operating limits vary by +- 2K due to component tolerances.The minimum volume flow specified in the device information must be ensured at the lower operating limit.In mono energy operating mode with the heating element activated, the maximum flow temperature increases by approximately 3K.Glen Dimplex Deutschland GmbHDimplex divisionAm Goldenen Feld 1895326 KulmbachPage 3/3Errors and omissions excepted!E-Mail: info@dimplex.deInternet: www.dimplex.dePrint date: 08.06.2012Telephone: +49 (0)9221 709-562Fax: +49 (0)9221 709-565

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!