3RW Soft Starters
3RW Soft Starters - Industrial Drives and Controls Ltd.
3RW Soft Starters - Industrial Drives and Controls Ltd.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>3RW</strong> <strong>Soft</strong> <strong>Starters</strong><strong>3RW</strong>44for High-Feature applications■ Technical specificationsType <strong>3RW</strong>44 ..-.BC3. <strong>3RW</strong>44 ..-.BC4.TerminalControl electronicsRated valuesRated control supply voltage A1/A2/PE V 115 AC 230 AC• Tolerance % -15/+10 -15/+10Rated control supply current STANDBY mA 30 20Rated control supply current ON• <strong>3RW</strong>442. mA 300 170• <strong>3RW</strong>443. mA 500 250• <strong>3RW</strong>444. mA 750 400Maximum current (pickup bypass)• <strong>3RW</strong>442. mA 1000 500• <strong>3RW</strong>443. mA 2500 1250• <strong>3RW</strong>444. mA 6000 3000Rated frequency Hz 50 ... 60 50 ... 60• Tolerance % –10 –10Type <strong>3RW</strong>44 ..TerminalFactory presettingControl electronicsControl inputsInput 1 IN1 Start motor right parameter set 1Input 2 IN2 No actionInput 3 IN3 No actionInput 4 IN4 Trip resetSupplyL+/L-• Rated operational current mA Approx. 10 per input to DIN 19240• Rated operational voltage L+ Internal voltage: 24 V DC frominternal supply through terminal L+ toIN1 ... IN4. Maximum load at L+Approx. 55 mAL- External voltage: DC external voltage(according to DIN 19240) throughterminals L- and IN1 ... IN4(min. 12 V DC, max. 30 V DC)Thermistor motor protection inputInput T1/T2 PTC type A or Thermoclick DeactivatedRelay outputs (floating auxiliary contacts)Output 1 13/14 ON periodOutput 2 23/24 No actionOutput 3 33/34 No actionOutput 4 95/96/98 Group faultSwitching capacity of the relay outputs230 V/AC-15 A 3 at 240 V24 V/DC-13 A 1 at 24 VProtection against overvoltagesProtection by means of varistor through relay contactShort-circuit protection4 A gL/gG operational class;6 A quick (fuse is not included in scope of supply)Protective functionsMotor protection functionsTrips in the event ofThermal overloading of the motorTrip class to IEC 60947-4-1 Class 5/10/15/20/30 10Phase loss sensitivity % > 40Overload warningYesReset and recovery Manual/Automatic ManualReset option after tripping Manual/Automatic ManualRecovery time min. 2...30 2Device protection functionsTrips in the event ofThermal overloading of the thyristorsReset option after tripping Manual/Automatic ManualRecovery time min. 0.56Siemens LV 1 T · 20066/23