22.08.2015 Views

3RW Soft Starters

3RW Soft Starters - Industrial Drives and Controls Ltd.

3RW Soft Starters - Industrial Drives and Controls Ltd.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>3RW</strong> <strong>Soft</strong> <strong>Starters</strong><strong>3RW</strong>44for High-Feature applications6Type <strong>3RW</strong>44 ..Factory presettingControl times and parametersControl timesClosing delay (with connected control voltage) ms < 50Closing delay (automatic mode) ms < 4000Recovery time (closing command in active ramp-down) ms < 100Mains failure bridging timeControl supply voltage ms 100Mains failure response timeLoad current circuit ms 100Reclosing lockout after overload tripMotor protection trip min. 1...30 1Device protection trip s 30Setting options for startingVoltage ramp for starting voltage % 20 ... 100 40Torque control for starting torque % 10 ... 100 50Torque control for limit torque % 20 ... 200 150Starting time s 0...360 20Maximum starting time s 1 ... 1000 DeactivatedCurrent limit value % 125 ... 550 450Breakaway voltage % 40 ... 100 80Breakaway time s 0...2 DeactivatedMotor heat output % 0...100 0Creep mode Left/Right runningSpeed factor as function of rated speed (n = n rated /factor) 3...21 7Creep torque (reference variable depends on the motor used but is % 20 ... 100 50always smaller than the rated torque of the motor)Setting options for ramp-downTorque control for stopping torque % 10 ... 100 40Ramp-down time s 0...360 10Combined braking % 20 ... 100 50DC braking % 20 ... 100 50Operating indicationsWarnings/error signalsTest voltageTest mains phasesReady to startStart activeMotor runningRamp-down activeMains voltage missingWrong start conditionPhase failure•L1•L2•L3Missing load phase•T1•T2•T3Failure• Contact element 1 (thyristor)• Contact element 2 (thyristor)• Contact element 3 (thyristor)Flash memory faultySupply voltage• Below 75 %• Below 85 %• Over 110 %Current unbalance exceededThermal motor model overloadPrewarning limit exceeded• Motor heating• Time-related trip reserveBypass elements defectiveMains overvoltageCurrent range exceededMotor blocking – shutdownCurrent limit exceededPower section overheatedPower section overtemperatureTemperature sensor- Overload- Open-circuit- Short-circuitGround fault detectedGround fault shutdownConnection abort in manual mode6/24 Siemens LV 1 T · 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!