Installation data:<br />

Making the connection<br />

Pipe cut between corrugations<br />

with fine tooth saw<br />

URM11 seal in<br />

first corrugation<br />

SNC6 snap cap and<br />

seal UR6IT<br />

Pipe socket or coupling<br />

150mm<br />

Quantum pipe<br />

UME15Q<br />

coupling<br />

160mm solid<br />

wall pipe<br />

Quantum seal fitted in first corrugation of pipe and handed as shown<br />

Cutting and jointing Quantum pipes<br />

Quantum pipes may be easily cut The procedure for jointing is as follows:<br />

to length on site if required using a 1. Ensure that the end of the pipe and<br />

fine tooth saw. Saw cuts should be<br />

inside the socket are free from swarf,<br />

made square to the pipe midway<br />

grit, etc.<br />

between the corrugations. It is not<br />

2. Fit seal into the first corrugation<br />

necessary to chamfer the end of the<br />

of the pipe making sure that the<br />

pipe after cutting.<br />

seal is correctly handed, as shown<br />

Unlike joints on standard solid wall<br />

above, and that it is not twisted.<br />

pipe, where the ring seal is located 3. Apply lubricant around the pipe<br />

in a housing within the socket, with<br />

seal and inside the socket.<br />

Quantum pipe the ring seal is fitted 4. Push pipe fully into the socket either<br />

around the pipe.<br />

by hand or by using a timber block<br />

and lever on the other end of the pipe.<br />

Connection to 160mm<br />

solid wall pipe<br />

All 150mm Quantum sockets<br />

have been designed for use with<br />

Quantum pipes and 160mm solid<br />

wall pipes to BS EN 1401: 2000.<br />

To adapt a Quantum fitting to<br />

accept 160mm solid wall drainage<br />

<br />

UR61T must be fitted to the end<br />

of the socket to enable a connection<br />

to be made, as shown above.<br />

Quantum couplings, bends, branches<br />

and reducers have an all socket<br />

configuration and jointing these to<br />

Quantum pipe is achieved in the same<br />

way as described above.<br />

A full technical design and installation guide is available to download from marley.co.uk Technical hotline: 01622 852695<br />