Water/water chiller and heat pump type MU ECHOS A
Water/water chiller and heat pump type MU ECHOS A
Water/water chiller and heat pump type MU ECHOS A
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Water</strong>/<strong>water</strong> <strong>chiller</strong> <strong>and</strong> <strong>heat</strong> <strong>pump</strong><br />
<strong>type</strong> <strong>MU</strong> <strong>ECHOS</strong> A<br />
Technical information manual<br />
Technical information manual<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl
CONTENTS<br />
Technical features 522<br />
Basic version general technical data 526<br />
Basic version electrical data 528<br />
Basic version cooling capacity 530<br />
Basic version <strong>heat</strong>ing capacity 532<br />
Mu Echos /LC Cooling capacity 534<br />
Mu Echos /LC/HP Heating capacity 536<br />
Mu Echos /LE Cooling capacity 538<br />
Mu Echos /LE/HP Heating capacity 540<br />
Operating limits 542<br />
Correction coefficient of fouling factors 545<br />
Noise levels 545<br />
Overall dimensions, weights, clearance areas<br />
<strong>and</strong> hydraulic connections 546<br />
Installation guidelines 575<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
2
TECHNICAL FEATURES<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
<strong>MU</strong> <strong>ECHOS</strong><br />
<strong>Water</strong>/<strong>water</strong> <strong>chiller</strong> <strong>and</strong> <strong>heat</strong> <strong>pump</strong> with scroll compressors <strong>and</strong> plate <strong>heat</strong> exchangers.<br />
STRUCTURE<br />
The units are designed to be installed from inside. The structure is in steel sheet coated with epoxy-polyester powder<br />
paint, with removable panels insulated with sound absorbing material. The sizes 6, 8 <strong>and</strong> 11 are painted with RAL<br />
7032 colour, suited for installation on the wall, the sizes from 16 to 48 are painted in RAL 5014 colour for installation<br />
on the floor.<br />
COMPRESSOR<br />
Rotary screw hermetically sealed scroll <strong>type</strong> compressors with internal thermal protection, <strong>heat</strong>er for the crankcase,<br />
supported by rubber antivibration mounts to reduce the vibrations transmission to the unit. Cooling circuit Comprende:<br />
feed inlets, dehydrating filter, thermostatic expansion valve, high <strong>and</strong> low pressure switches. Units of sizes from 16 to<br />
48 are also provided with safety valve <strong>and</strong> fluid sight glass.<br />
EVAPORATOR<br />
Brazed plate <strong>heat</strong> exchanger in stainless steel AISI 316 insulated against condensate, temperature probe on the<br />
vane-operated flow switch antifreeze protection (installed on sizes 6, 8 <strong>and</strong> 11 <strong>and</strong> supplied with the unit for the other<br />
sizes).<br />
CONDENSER<br />
Brazed plate condenser in stainless steel AISI 316 sized to operate with well <strong>water</strong> (in/out 15/30 °C). The <strong>chiller</strong> units<br />
can be fitted upon request with condenser sized to operate with tower <strong>water</strong> (in/out 30/35°C).<br />
ELECTRICAL PANEL<br />
The panel consists of: main disconnect switch, automatic disconnect switch for the main <strong>and</strong> auxilliary power circuit<br />
protection, compressor remote disconnect switch, on/off digital signal input contact, microprocessor for parameter<br />
setting control of the following functions:<br />
• Regulation of <strong>water</strong> temperature;<br />
• Control of set-point self-regulation;<br />
• Anti-freeze protection<br />
• Compressor timing<br />
• Alarm signalling<br />
• Alarm reset<br />
• Cumulative alarm contact for remote signaling;<br />
The control display shows the following information:<br />
• Ingoing <strong>and</strong> outgoing <strong>water</strong> temperature;<br />
• Currently set temperature <strong>and</strong> differential<br />
• Alarm description<br />
• Operation hour counter;<br />
The st<strong>and</strong>ard power supply for the sizes 6, 8 <strong>and</strong> 11 is 230V/1~/50Hz <strong>and</strong> 400V/3~/50Hz for the other sizes.<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
3
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
CONTROL AND SAFETY DEVICES<br />
The units are equipped with:<br />
• Manual reset high pressure switch<br />
• Controlled manual reset low pressure switch;<br />
• High pressure safety valve (except for the 6, 8 <strong>and</strong> 11 sizes, basic <strong>and</strong> /HP version);<br />
• <strong>Water</strong> temperature probe on the user side, installed on the <strong>heat</strong> exchanger inlet;<br />
• Antifreeze probe on the user side <strong>heat</strong> exchanger outlet;<br />
• Vane-operated mechanical flow switch fitted on sizes 6, 8 <strong>and</strong> 11 <strong>and</strong> supplied with the unit for the other sizes;<br />
• Compressor over temperature internal protection.<br />
TESTING<br />
All units are factory-tested <strong>and</strong> supplied complete with oil <strong>and</strong> refrigerant (except for the LE, LE/HP, LC <strong>and</strong> LC/HP<br />
units).<br />
VERSIONS<br />
Check the table with the available configurations for any interferences between one option <strong>and</strong> the other.<br />
The basic version constists of a cooled-<strong>water</strong> <strong>water</strong> <strong>chiller</strong>.<br />
<strong>MU</strong> <strong>ECHOS</strong> A /HP:<br />
reversible <strong>heat</strong> <strong>pump</strong><br />
Besides the components of the <strong>MU</strong> <strong>ECHOS</strong> A, the cooling circuit is equipped with 4-way inversion valve <strong>and</strong> a second<br />
thermostatic expansion valve. The hydraulic circuit consists of a pressure switch valve, a bypass solenoid valve <strong>and</strong> a<br />
second vane-operated <strong>water</strong> flow switch. These components are already installed on the 6, 8 <strong>and</strong> 11 sizes <strong>and</strong> for the<br />
other sizes they are supplied with in the kit). The electrical panel has a digital input contact for summer/winter<br />
switching.<br />
<strong>MU</strong> <strong>ECHOS</strong> A /LE:<br />
motocondensing unit<br />
Motocondensing unit: The unit is designed to operate with an air-cooled evaporator therefore it does not have a <strong>heat</strong><br />
exchanger on the user side or a thermostatic valve (can be supplied in the kit upon request). The unit is loaded with<br />
nitrogen instead of refrigerant.<br />
<strong>MU</strong> <strong>ECHOS</strong> A /LE /HP<br />
reversible motocondensing unit<br />
The unit is designed to operate with a remote air-cooled evaporator/condenser therefore it does not have a <strong>heat</strong><br />
exchanger on the user side or a thermostatic valve suited for <strong>chiller</strong> operation mode(can be supplied in the kit upon<br />
request). The unit has a fluid receiver sized for the split unit supplied by Blue Box <strong>and</strong> the thermostatic valve for the<br />
<strong>heat</strong> <strong>pump</strong> operation mode. The unit is loaded with nitrogen instead of refrigerant.<br />
<strong>MU</strong> <strong>ECHOS</strong> A /LC<br />
motoevaporating unit<br />
The unit has no <strong>heat</strong> exchanger on the source side in order to allow connection to a remote air-cooled condenser. The<br />
unit is loaded with nitrogen instead of refrigerant.<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
4
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
<strong>MU</strong> <strong>ECHOS</strong> A /LC /HP<br />
reversible motoevaporating unit<br />
The unit has no thermostatic valve for <strong>heat</strong> <strong>pump</strong> operation mode <strong>and</strong> no <strong>heat</strong> exchanger on the source side in order<br />
to allow connection to a remote air-cooled condenser/ evaporator. The unit has a fluid receiver sized for the remote<br />
condenser supplied by Blue Box. The unit is loaded with nitrogen instead of refrigerant.<br />
<strong>MU</strong> <strong>ECHOS</strong> A /LN<br />
low-noise unit<br />
The sizes 6, 8 <strong>and</strong> 11 with this outfit require the replacement of the st<strong>and</strong>ard sound absorbing material with a multilayer<br />
acoustic insulation of high impedance. The sizes from 16 to 48 require the installation of a sound-proof<br />
cover on the compressor. This outfit can be combined with all aforementioned versions of the unit<br />
HYDRAULIC SYSTEM OPTIONS<br />
The unit basic version has no circulation device or <strong>pump</strong> installed (except for the 6, 8 <strong>and</strong> 11 sizes). All the outfits<br />
(except for LE <strong>and</strong> LE/HP) can be equipped upon request with one of the following hydraulic modules:<br />
/ST 1P<br />
Besides the st<strong>and</strong>ard components installed, the unit has a circulation <strong>pump</strong>. This version is not suitable for the 6, 8<br />
<strong>and</strong><br />
11 sizes.<br />
/ST 1PS<br />
Besides the st<strong>and</strong>ard components installed, the unit has an inertial insulated storage tank <strong>and</strong> a circulation <strong>pump</strong>. The<br />
sizes 6, 8, 11 <strong>and</strong> from 16 to 48 of the HP version have the safety valve <strong>and</strong> the expansion vessel fitted as st<strong>and</strong>ard.<br />
This version is st<strong>and</strong>ard for the sizes 6, 8 <strong>and</strong> 11 while for the other sizes it must be requested when ordering.<br />
ACCESSORIES<br />
The unit in basic version <strong>and</strong> of various outfits can also be fitted with extra accessories. For a complete list of<br />
accessories refer to the price list.<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
5
Basic version general technical data<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
6
Basic version general technical data<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
(1) User side ingoing-outgoing <strong>water</strong> temperature 30/35ºC; source side ingoing-outgoing <strong>water</strong> temperature 15/10°C<br />
(2) User side ingoing-outgoing <strong>water</strong> temperature 40/45 ºC; source side ingoing-outgoing <strong>water</strong> temperature 15/10°C<br />
(3) User side ingoing-outgoing <strong>water</strong> temperature 30/35 ºC source side ingoing-outgoing glycol solution temperature 0/-3<br />
(4) User side ingoing-outgoing <strong>water</strong> temperature 40/45 ºC source side ingoing-outgoing glycol solution temperature 0/-3<br />
(5) User side ingoing-outgoing <strong>water</strong> temperature 12/7 ºC; source side ingoing <strong>water</strong> temperature 15/30°C<br />
(6) User side ingoing-outgoing <strong>water</strong> temperature 23/18 ºC; source side ingoing <strong>water</strong> temperature 30/35°C<br />
(7) User side ingoing-outgoing <strong>water</strong> temperature 12/7 ºC; source side ingoing <strong>water</strong> temperature 30/35°C<br />
(8) User side ingoing-outgoing <strong>water</strong> temperature 23/18 ºC; source side ingoing-outgoing glycol solution temperature 30/35<br />
(9) User side ingoing-outgoing <strong>water</strong> temperature 12/7 ºC; source side ingoing-outgoing glycol solution temperature 30/35<br />
(10) For ST 1PS version<br />
(11) Noise power levels calculated according to ISO 3744<br />
(12) Noise pressure levels measured at 1 meter from the unit in free field, with a directivity factor Q=4<br />
(1) The weight is only indicative <strong>and</strong> may vary depending on the unit outfit<br />
(2) The clearance areas are indicated considering that the unit is controlled from the front side.<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
7
Operating limits<br />
Version CH <strong>and</strong> HP<br />
Version LC <strong>and</strong> LC/ HP<br />
Version LE <strong>and</strong> LE/ HP<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
The <strong>heat</strong> exchanger temperature rise must be within 4ºC e 7ºC<br />
(1): within this range the unit can operate only with glycol solution on evaporator side<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
8
Basic version electrical data<br />
The indicated data is valid for unit with st<strong>and</strong>ard power supply<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
(1) Electrical power that must be supplied by the mains to power the unit.<br />
(2) Internal breakers tripping current. This value is never exceeded <strong>and</strong> must be used to size the line <strong>and</strong> its protections (refer to the electric<br />
diagram supplied with the unit).<br />
(3) The maximum peak of the current is calculated considering the compressor start <strong>and</strong> the maximum power absorbed by all the other devices.<br />
The value between parentheses refers to the units equipped with soft-starter (optional).<br />
(4) To be asked for when ordering<br />
The values <strong>and</strong> images inside the document are indicative <strong>and</strong> can be modified by the manufacturer without prior notification.<br />
For further information refer to the specific documentation. The reproduction of this material, even partial, is prohibited.<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
9
Basic version cooling capacity<br />
Pf: cooling capacity [kW]<br />
Pe: electrical power absorbed by the compressors [kW]<br />
T0: evaporator outgoing <strong>water</strong> temperature [°C]<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
10
Basic version cooling capacity<br />
Pf: cooling capacity [kW]<br />
Pe: electrical power absorbed by the compressors [kW]<br />
T0: evaporator outgoing <strong>water</strong> temperature [°C]<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
11
Basic version <strong>heat</strong>ing capacity<br />
Pt: condenser <strong>heat</strong>ing capacity [kW]<br />
Pe: electrical power absorbed by the compressors [kW]<br />
T0: evaporator outgoing <strong>water</strong> temperature [°C]<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
12
Basic version <strong>heat</strong>ing capacity<br />
Pt: condenser <strong>heat</strong>ing capacity [kW]<br />
Pe: electrical power absorbed by the compressors [kW]<br />
T0: evaporator outgoing <strong>water</strong> temperature [°C]<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
13
Mu Echos A /LC - cooling capacity<br />
l<br />
Pf: cooling capacity [kW]<br />
Pe: electrical power absorbed by the compressors [kW]<br />
T0: evaporator outgoing <strong>water</strong> temperature [°C]<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
14
Mu Echos A /LC - cooling capacity<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Pf: cooling capacity [kW]<br />
Pe: electrical power absorbed by the compressors [kW]<br />
T0: evaporator outgoing <strong>water</strong> temperature [°C]<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
15
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Mu Echos A /LC/HP - <strong>heat</strong>ing capacity<br />
Pt: condenser <strong>heat</strong>ing capacity [kW]<br />
Pe: electrical power absorbed by the compressors [kW]<br />
T0: evaporation temperature [°C]<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
16
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Mu Echos A /LC/HP - <strong>heat</strong>ing capacity<br />
Pt: condenser <strong>heat</strong>ing capacity [kW]<br />
Pe: electrical power absorbed by the compressors [kW]<br />
T0: evaporation temperature [°C]<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
17
Mu Echos A /LE - cooling capacity<br />
Pf: cooling capacity [kW]<br />
Pe: electrical power absorbed by the compressors [kW]<br />
Tev: evaporation temperature [°C]<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
18
Mu Echos A /LE - cooling capacity<br />
Pf: cooling capacity [kW]<br />
Pe: electrical power absorbed by the compressors [kW]<br />
Tev: evaporation temperature [°C]<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
19
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Mu Echos A /LE/HP - <strong>heat</strong>ing capacity<br />
Pt: <strong>heat</strong>ing capacity [kW]<br />
Pe: electrical power absorbed by the compressors [kW]<br />
T0: evaporator outgoing <strong>water</strong> temperature [°C]<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
20
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Mu Echos A /LE/HP - <strong>heat</strong>ing capacity<br />
Pt: <strong>heat</strong>ing capacity [kW]<br />
Pe: electrical power absorbed by the compressors [kW]<br />
T0: evaporator outgoing <strong>water</strong> temperature [°C]<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
21
Noise levels<br />
St<strong>and</strong>ard unit<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Lw: sound power levels measured in free field according to st<strong>and</strong>ard ISO 3744; under nominal operating conditions.<br />
Lp: sound pressure levels measured at 1 metres from the unit in free field under nominal operating conditions, according to ISO 3744.<br />
Low Noise unit<br />
Lw: sound power levels measured in free field according to st<strong>and</strong>ard ISO 3744; under nominal operating conditions.<br />
Lp: sound pressure levels measured at 1 metres from the unit in free field under nominal operating conditions, according to ISO 3744.<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
22
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 6 – 11<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE/HP 6 - 11<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
23
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 6 - 11<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE/HP 6 - 11<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
24
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 6 – 11 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 6 - 11<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 6 – 11 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 6 - 11<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
25
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 6 – 11 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 6 - 11<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 6 – 11 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 6 - 11<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
26
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /HP 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /LE/HP 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1P 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1P 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1P 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> LC/HP-ST 1P 16 - 22<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
27
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /HP 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /LE/HP 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1P 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1P 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1P 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> LC/HP-ST 1P 16 - 22<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
28
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /HP 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /LE/HP 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1P 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1P 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1P 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> LC/HP-ST 1P 16 - 22<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
29
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /HP 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /LE/HP 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1P 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1P 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1P 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> LC/HP-ST 1P 16 - 22<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
30
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 16 - 22<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
31
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 16 - 22<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
32
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 16 - 22<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
33
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 16 - 22<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 16 – 22 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 16 - 22<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
34
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /HP 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /LE/HP 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1P 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1P 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1P 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> LC/HP-ST 1P 24 - 28<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
35
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /HP 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /LE/HP 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1P 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1P 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1P 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> LC/HP-ST 1P 24 - 28<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
36
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /HP 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /LE/HP 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1P 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1P 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1P 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> LC/HP-ST 1P 24 - 28<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
37
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /HP 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /LE/HP 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1P 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1P 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1P 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> LC/HP-ST 1P 24 - 28<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
38
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 24 - 28<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
39
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 24 - 28<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
40
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 24 - 28<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
41
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 24 - 28<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 24 – 28 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 24 - 28<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
42
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> HP 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> LC/HP 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> LE/HP 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1P 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> HP 1P 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1P 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> LC/HP-ST 1P 32 - 48<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
43
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> HP 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> LC/HP 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> LE/HP 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1P 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> HP 1P 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1P 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> LC/HP-ST 1P 32 - 48<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
44
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 32 - 48 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 32 – 48<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
45
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 32 - 48 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 32 – 48<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
46
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 32 - 48 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 32 – 48<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
47
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1PS 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1PS 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1PS 32 - 48 <strong>MU</strong> <strong>ECHOS</strong> /LC/HP-ST 1PS 32 – 48<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
48
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> HP 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> LC/HP 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 32 - 48 <strong>MU</strong> <strong>ECHOS</strong> LE/HP 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /ST 1P 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> /HP-ST 1P 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC-ST 1P 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> LC/HP-ST 1P 32 - 48<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
49
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Overall dimensions, weights, clearance areas <strong>and</strong> hydraulic connections<br />
<strong>MU</strong> <strong>ECHOS</strong> 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> /ST 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LC 32 – 48 <strong>MU</strong> <strong>ECHOS</strong> /LC-ST 32 - 48<br />
<strong>MU</strong> <strong>ECHOS</strong> /LE 32 - 48<br />
___________________________________________________________________________________________<br />
Western Airconditioning B.V. Hoevelaken Tel. (033) 247 78 00 E-mail: sales@western.nl www.western.nl<br />
50
INSTALLATION GUIDELINES<br />
Technical information manual <strong>MU</strong> <strong>ECHOS</strong> A<br />
REF.<strong>MU</strong>_<strong>ECHOS</strong>_A-10232000102_07.10/<strong>MU</strong>_<strong>ECHOS</strong>_A_2011.DOC<br />
Positioning<br />
- Strictly comply with the clearance areas indicated in the catalogue.<br />
- Make sure that there are no obstructions near the finned coil suction or the fan air discharge.<br />
- Place the unit in a manner that assures the lowest environmental impact (noise, integration with nearby structures,<br />
etc.).<br />
Wiring<br />
- Always consult the enclosed wiring diagram, which provides all the instructions required for making the electrical<br />
connections.<br />
- Power up the unit (closing the disconnect switch), at least 12 hours before start-up, in order to turn the crankcase<br />
<strong>heat</strong>ers on. Do not switch the power off during short stoppages.<br />
- Before turning on the disconnect switch, stop the unit by turning off all the operating switches or using the remote<br />
control.<br />
- Before accessing the inner components, cut the power off by turning on the disconnect switch.<br />
- The power supply must be fitted with all protections according to the st<strong>and</strong>ards in force.<br />
- Electrical connections: three-pole power cable + earth, or three pole cable + neutral + earth; external interlock;<br />
remote alarm signalling.<br />
Hydraulic conections<br />
- Carefully vent the hydraulic system with the <strong>pump</strong> switched off, by turning the air valve. This procedure is particularly<br />
important, as even small air bubbles may cause the evaporator to freeze.<br />
- Drain the system during winter stops or use special anti-freeze solutions. During short stops, it is advisable to install<br />
an electric <strong>heat</strong>er (defroster) on the evaporator <strong>and</strong> the hydraulic circuit.<br />
- Install the hydraulic circuit with all the components shown in the diagrams (expansion vessel, flow switch, storage<br />
tank, air valve, shut-off valves, flexible connections, etc. Please refer to the user, installation <strong>and</strong> maintenance<br />
manual).<br />
- Connect the flow switch when supplied in the kit, following carefully the instructions provided with the units.<br />
Start -up <strong>and</strong> maintenance<br />
- Strictly follow the instructions given in the use <strong>and</strong> maintenance manual.<br />