20.09.2015 Views

PROOFMASTER S

PROOFMASTER S - Lindholt

PROOFMASTER S - Lindholt

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2.3 PRESET PROGRAMS<br />

Lindholts Fourniturehandel ApS. | Sportsvej 6 | 8930 Randers NØ<br />

P1 - Safe Test<br />

Test 1 - 0.2 bar<br />

Test 2 + 2.0 bar<br />

P2 - Men Standard<br />

Test 1 - 0.4 bar<br />

Test 2 + 3.0 bar<br />

P3 - Ladies<br />

Test 1 - 0.4 bar<br />

Test 2 + 2.0 bar<br />

P4 - Hard Case<br />

Test 1 - 0.7 bar<br />

Test 2 + 3.0 bar<br />

P5 – Jewelery<br />

Test 1 - 0.2 bar<br />

Test 2 + 1.0 bar<br />

P6 – Diver 100m<br />

Test 1 - 0.7 bar<br />

Test 2 + 10.0 bar<br />

This program can be used with all types of water-resistant watches<br />

without risk of damages.<br />

This programme gives unreliable results with hard watches.<br />

Standard program for gent’s watches, plastic or metal.<br />

Program for small watches (lady’s watches).<br />

For hard, stable watches with ceramic case and mineral glass.<br />

For jewellery watches and other watches with less stable cases.<br />

Threefold test for diver watches that are specified for at least 100 m<br />

water depth.<br />

P7 – Pressure only<br />

Test 1 + 2.0 bar Pressure only, for quick tests.<br />

P8 - Two pressures<br />

Test 1 + 0.5 bar<br />

Test 2 + 3.0 bar<br />

C01 – C10<br />

1 low pressure and a higher pressure (double pressure test).<br />

For watches that should not be vacuum tested.<br />

Test programs adaptable to your requirements.<br />

See Chapter 60H4 CUSTOMER - SPECIFIC PROGRAMS<br />

2.4 POSITIONING THE WATCH<br />

The watch must be at ambient temperature for the test to be reliable. Results<br />

can be invalidated by variations in the watch temperature during the test.<br />

Test results can be invalidated by adhesive protection on the bottom or on the<br />

glass of the watch.<br />

Lift the sensor with knob A. When lifting the knob, the sensor is unlocked and can be freely moved<br />

up and down.<br />

Tlf. 86 42 52 99 | Fax 89 41 37 45 | lindholts@email.dk | www.lindholts.dk