Catalogue HY11-3500/UK<br />

Shift Limits / Pin assignment<br />

The diagram below specifies the shift limits. The specifications<br />

apply to balanced flow conditions. The shift limits<br />

can be considerably lower at unbalanced flow conditions.<br />

Directional Control Valve<br />

Series D1VW 8 Watt<br />

To avoid flow rates beyond the shift limits, a plug-in orifice<br />

can be inserted in the P-port.<br />

Shift limit<br />

Supply pressure [bar]<br />

Supply pressure [bar]<br />

350<br />

300<br />

250<br />

200<br />

150<br />

100<br />

101<br />

082,<br />

102<br />

009,<br />

081<br />

001,<br />

010,<br />

020<br />

50<br />

008,<br />

026<br />

0<br />

0 10 20 30 40 50<br />

60<br />

Flow [l/min]<br />

350<br />

002, 004,<br />

003, 011,<br />

300 007, 005,<br />

015, 030<br />

014 016<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

0 10 20 30 40 50<br />

60<br />

Flow [l/min]<br />

006<br />

2<br />

Measured with HLP46 at 50°C, 90% U nom<br />

and warm solenoids<br />

M12 pin assignment DESINA design (code „JDLJ5“),<br />

Pins 1 and 2 connected<br />

M12 pin assignment code “JDL“,<br />

Pins 1 and 2 not connected<br />

D1VW-8W UK.INDD RH 15.08.2011<br />

2-19<br />

Parker Hannifin Corporation<br />

<strong>Hydraulic</strong>s Group