26.09.2015 Views

Dialab Catalogue

Dialab Catalogue

Dialab Catalogue

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

product range<br />

2008<br />

diagnostics<br />

instruments<br />

w w w . d i a l a b . a t


COMPANY PROFILE<br />

ABOUT US<br />

DIALAB ® GmbH was founded in 1972. DIALAB ® with its headquarters and main plant, located south of<br />

Vienna in Wr. Neudorf / Austria, is a manufacturer and distributor of Diagnostics and Laboratory Equipment –<br />

it offers the widest range of Laboratory Diagnostics worldwide.<br />

We dedicate ourselves exclusively to supporting the clinical laboratory and to supplying a complete<br />

range of products, based on 3 product lines, namely Clinical Chemistry Reagents, Immunological<br />

Reagents and Coagulation Reagents. Presently, DIALAB ® supplies its wide product range to more than<br />

100 countries around the world.<br />

>>> FACTS<br />

Including 3 subsidiaries, located in Prague / Czech Republic, Budapest / Hungary and Belgrade / Serbia<br />

we are a total of over 60 employees, we are ISO 13485:2003 certified and a great number of our products is<br />

CE-marked.<br />

We are engaged in business relations worldwide, we have production and research facilities in Wr.<br />

Neudorf / Austria and Prague / Czech Republic.<br />

>>> OEM/BULK<br />

We offer different options for our OEM partners.<br />

Generally, DIALAB ® can provide reagents in bulk, customised kits, labelled vials or unlabelled vials.<br />

>>> PRODUCT TRAINING<br />

DIALAB ® offers training programs in its headquarter in Wr. Neudorf in order to support its customers.<br />

>>> APPLICATIONS<br />

Suggested application procedures for DIALAB ® reagents are available for most analysers.<br />

>>> ORDERS AND PRICING<br />

Contact your DIALAB ® Distributor or contact DIALAB ® directly at:<br />

Phone: +43 / 2236 / 660910 0 · Fax: +43 / 2236 / 660910 30/31<br />

e-mail: office@dialab.at · website: www.dialab.at<br />

>>> CUSTOMER SERVICE<br />

DIALAB ® will assist you by telephone, fax or e-mail with any information related to our products.<br />

>>> WARRANTY<br />

DIALAB ® products are warranted to perform according to the procedures described in the instruction insert<br />

accompanying the product. Changes or modifications of the product may adversely affect the stated performances.<br />

DIALAB ® shall not be liable for any damages arising out of incorrect use of the products.<br />

Graphic Design, Photographs and Production: www.neumannweb.at<br />

for more details >>> www.dialab.at


CONTENTS<br />

>>>Diagnostics<br />

NEW<br />

>>>Instruments<br />

Clinical Chemistry . . . . . . . . . . . . . . . . . . . . . . . . . 2<br />

Immunoturbidimetry / -nephelometry . . . . . . . . . . 4<br />

Therapeutic Drug Monitoring . . . . . . . . . . . . . . . . . 6<br />

DOA Liquid Immunoassays . . . . . . . . . . . . . . . . . . 7<br />

Diaquick Rapid Tests . . . . . . . . . . . . . . . . . . . . . . . 8<br />

ELISA Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

Coagulation and Fibrinolysis . . . . . . . . . . . . . . . . . 14<br />

Serology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16<br />

Blood Grouping and Rhesus Typing . . . . . . . . . . . . 17<br />

Urine Strips / Urine Strip Analyser . . . . . . . . . . . . 18<br />

Vacollect – Evacuated Blood Collection Tubes<br />

& Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 19<br />

Autolyzer 600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

Autolyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

Photometer DTN-410 / DTN-410K . . . . . . . . . . . . . . 24<br />

Diareader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

Diawasher. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />

Coagulometers – General Information . . . . . . . . . 28<br />

DIAcheck ® C1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29<br />

DIAcheck ® C2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30<br />

DIAcheck ® C4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

DIAchrom C4 combi . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

>>>Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />

for more details >>> www.dialab.at 1


CLINICAL CHEMISTRY<br />

Liquid Reagents ”ready to use“<br />

>>> Supplements and Additives<br />

Cobas Mira Blank Solution, for Homocysteine on Cobas Mira<br />

CK-MB Supplement, for CK-MB, opt. DGKC / IFCC<br />

Creatinine Supplement, for Creatinine, mod. Jaffé<br />

Creatinine Urine Diluent, for Creatinine, mod. Jaffé with Supplement<br />

G6PDH Lyse Reagent, for G6PDH, UV, kinetic<br />

Mineral Oil, for G6PDH Deficiency Screen<br />

Pyridoxal-5-Phosphate, for GOT and GPT, mod IFCC<br />

>>> Standards<br />

Albumin Standard<br />

Bile Acid Standard<br />

Calcium Standard<br />

Chloride Standard<br />

Cholesterol Standard<br />

CO 2 Standard<br />

Creatinine Standard<br />

Glucose Standard<br />

NEFA Standard<br />

>>> Calibrators<br />

Iron Standard<br />

Magnesium Standard<br />

Phosphorus Standard<br />

Protein Total Standard<br />

Protein Total in Urine/CSF Standard<br />

Triglycerides Standard<br />

Urea Standard<br />

Uric Acid Standard<br />

Copper Standard<br />

Zinc Standard<br />

Diacal Auto (assayed multicomponent calibration serum, human)<br />

Ethanol Calibrator/Control Set<br />

Haemoglobin Total Calibrator<br />

HbA1c Direct Calibrator, 4 level series<br />

HDL-Cholesterol Calibrator<br />

LDL-Cholesterol Calibrator<br />

>>> Controls<br />

Diacon N (assayed multicomponent control serum normal, human)<br />

Diacon P (assayed multicomponent control serum abnormal, human)<br />

Diacon Lipids (assayed lipid control serum normal, human)<br />

Diacon Urine Level 1 (urine chemistry control)<br />

Diacon Urine Level 2 (urine chemistry control)<br />

G6PDH Control Set, 3 levels<br />

Hemoglobin Total Control Set, 3 levels<br />

HbA1c Control Set, 3 levels<br />

HbA1c Direct Control Set, 2 levels<br />

Homocysteine Control Set, 4 levels<br />

2 for more details >>> www.dialab.at


CLINICAL CHEMISTRY<br />

Liquid Reagents ”ready to use“<br />

>>> Reagents<br />

Acid Phosphatase, Hillman *<br />

Albumin, BCG<br />

Alkaline Phosphatase, opt. DGKC<br />

Alkaline Phosphatase, mod. IFCC<br />

alpha-Amylase, mod. IFCC<br />

alpha-Amylase, CNP-G3<br />

alpha-Amylase Pancreatic, ET-G7PNP<br />

Bile Acids, enzymatic recycling<br />

Bilirubin Auto Direct, DCA, with ATCS<br />

Bilirubin Auto Total, DCA, with ATCS<br />

Bilirubin Direct, Jendrassik Grof<br />

Bilirubin Total, Jendrassik Grof<br />

Bilirubin Direct/Total, Jendrassik Grof<br />

Calcium, Arsenazo, with ATCS<br />

Calcium, CPC, with ATCS<br />

Carbon Dioxide (CO 2 ), PEP-C<br />

Chloride, Mercuric Thiocyanate<br />

Cholesterol, CHOD-PAP, with ATCS<br />

Cholesterol HDL, Precipitation<br />

Cholesterol HDL, Direct, Immunoinhibition<br />

Cholesterol LDL,<br />

Cholinesterase, opt. DGKC<br />

CK-MB, opt. DGKC / IFCC<br />

CK-NAC, opt. DGKC / IFCC<br />

Creatinine, mod. Jaffé<br />

Direct, enz. selective protection<br />

Creatinine, enzymatic, PAP, with ATCS<br />

Ethanol, enzymatic, UV<br />

G6PDH, UV, kinetic *<br />

New products:<br />

Copper, DiBr-PAESA<br />

Lactate, Enzymatic, UV<br />

G6PDH Deficiency Screen, qualitative, visual *<br />

Gamma GT, SZASZ, stand. to IFCC<br />

GLDH, DGKC<br />

Glucose, GOD-PAP<br />

Glucose, Hexokinase<br />

GOT (AST), mod. IFCC<br />

GPT (ALT), mod. IFCC<br />

HbA1c Direct, immunoturbidimetric<br />

HbA1c, ion exchange<br />

alpha-HBDH, opt. DGKC<br />

Haemoglobin Total, Cyanmethaemoglobin<br />

Homocysteine<br />

Iron, Ferene<br />

LDH-L, IFCC<br />

LDH-P, opt. DGKC<br />

Lipase, enzymatic, colorimetric<br />

(incl. standards), enzymatic recycling<br />

Magnesium, Xylidyl Blue, with ATCS<br />

Phosphorus Inorganic, Molybdate<br />

Protein Total, Biuret<br />

Protein Total in Urine/CSF, Pyrogallol red<br />

Triglycerides, GPO-PAP, with ATCS<br />

UIBC, Ferene<br />

Urea, Urease / colorimetric<br />

Urea UV Auto fast rate, Urease / GLDH<br />

Uric Acid AOX, enzymatic, colorimetric, with ATCS<br />

Uric Acid TBHBA, enzymatic, colorimetric, with ATCS<br />

NEFA, ACOD-PAP<br />

Zinc, Br-PAPS<br />

* Dry Powder<br />

ATCS: Advanced Turbidity Clearing System minimises interferences caused by lipemia<br />

Also available as systempacks for Hitachi, Kone, Prestige<br />

For more detailed information about our Chlinical Chemistry reagents<br />

please refer to our special “Clinical Chemistry” brochure.<br />

for more details >>> www.dialab.at 3


IMMUNOTURBIDIMETRY /<br />

-N EPHELOMETRY<br />

Liquid Reagents ”ready to use“<br />

>>> Calibrators (liquid, ready to use)<br />

NEW<br />

Alpha-1 Microglobulin Calibrator<br />

APO A1/A2/B Calibrator<br />

APO E Calibrator<br />

ASO Calibrator, low / high / super high<br />

ß-2 Microglobulin Calibrator, 4 level series<br />

CRP Calibrator, low / high / super high / 5 level series<br />

CRP Uhs Calibrator, universal range / high sensitive range<br />

Cystatin C Calibrator, 5 level series<br />

Ferritin Calibrator, 5 level series<br />

Fibrinogen Calibrator<br />

IgD Calibrator<br />

HbA1c Direct Calibrator, 4 level series<br />

Lp(a) Calibrator, low / high / 4 level series<br />

Microalbumin Calibrator, high / 5 Level series<br />

Pediatric Calibrator, low<br />

Protein Calibrator, low / high / 5 level series (AAT, AGP, ALB, AMG, AT3, C1I, C3, C4, CER, FIN, HAP, IgA, IgG, IgM, KAP,<br />

LAM, PAL,TRF)<br />

RF Calibrator, low / high / super high<br />

Transferrin Calibrator, 5 level series<br />

>>> Controls (liquid, ready to use)<br />

NEW<br />

Alpha-1 Microglobulin Control<br />

APO A1/A2/B Control<br />

APO E Control<br />

ASO Control<br />

ß-2 Microglobulin Control<br />

CRP Control, low / high<br />

CRP Uhs Control, universal range / high sensitive range<br />

Cystatin C Control, 2 levels<br />

Ferritin Control, low / high<br />

Fibrinogen Control<br />

HbA1c Direct Control, 2 levels<br />

Lp(a) Control, low / high<br />

Microalbumin Control<br />

Pediatric Control<br />

Protein Control (AAT, AGP, ALB, AMG, ASO, AT3, BMG, C1I, C3, C4, CER, CRP, FER, HAP, IgA, IgG, IgM, KAP, LAM, PAL, RF, TRF)<br />

Protein Control Low (AAT, AGP, ALB, AMG, ASO, AT3, BMG, C1I, C3, C4, CER, CRP, FER, HAP, IgA, IgG, IgM, KAP, LAM, PAL, RF, TRF)<br />

RF Control<br />

4 for more details >>> www.dialab.at


IMMUNOTURBIDIMETRY<br />

Liquid Reagents ”ready to use“<br />

>>> 2 Reagent Kits<br />

Alpha-1 Antitrypsin, antibody reagent<br />

Alpha-1 Acid Glycoprotein, antibody reagent<br />

Alpha-1 Microglobulin, latex reagent<br />

Albumin, antibody reagent<br />

Alpha-2 Macroglobulin, antibody reagent<br />

APO A1, antibody reagent<br />

APO A2, antibody reagent<br />

APO B, antibody reagent<br />

IgD, antibody reagent<br />

ASO, latex reagent<br />

Antithrombin III, antibody reagent<br />

ß-2 Microglobulin, latex reagent<br />

C1 Esterase Inhibitor, antibody reagent<br />

C3, antibody reagent<br />

C4, antibody reagent<br />

Ceruloplasmin, antibody reagent<br />

CRP, antibody reagent<br />

CRP Uhs, latex reagent<br />

Cystatin C, latex reagent NEW<br />

Ferritin, latex reagent<br />

Fibrinogen, antibody reagent<br />

Fibronectin, antibody reagent<br />

Haptoglobin, antibody reagent<br />

HbA1c Direct, latex reagent<br />

IgA, antibody reagent<br />

IgG, antibody reagent<br />

IgM, antibody reagent<br />

Kappa Light Chains, antibody reagent<br />

Lambda Light Chains, antibody reagent<br />

Lp(a), latex reagent<br />

Microalbumin hs, antibody reagent<br />

Plasminogen, antibody reagent<br />

Prealbumin, antibody reagent<br />

Rheumatoid Factor, antibody reagent<br />

Transferrin, antibody reagent<br />

>>> Single Reagents (antibody reagents)<br />

Alpha-1 Antitrypsin<br />

Alpha-1 Acid Glycoprotein<br />

Albumin<br />

Alpha-2 Macroglobulin<br />

APO A1<br />

APO B<br />

C3<br />

C4<br />

Ceruloplasmin<br />

CRP<br />

Haptoglobin<br />

IgA<br />

IgG<br />

IgM<br />

Transferrin<br />

>>> BNA Reagents (for the BNA Nephelometer)<br />

Alpha-1 Antitrypsin<br />

Alpha-1 Acid Glycoprotein<br />

Albumin<br />

Alpha-2 Macroglobulin<br />

APO A1<br />

APO B<br />

C3<br />

C4<br />

Ceruloplasmin<br />

Haptoglobin<br />

IgA<br />

IgG<br />

IgM<br />

Transferrin<br />

For more detailed information about our immunoturbidimetric reagents<br />

please refer to our special “Immunoturbidimetric Tests” brochure.<br />

for more details >>> www.dialab.at 5


THERAPEUTIC DRUG MONITORING<br />

Liquid Reagents ”ready to use“<br />

>>> Reagents (Latex Reagents)<br />

Carbamazepine<br />

Digoxin<br />

Digitoxin<br />

Gentamicin<br />

Phenytoin<br />

Phenobarbital<br />

Theophylline<br />

Valproic Acid<br />

>>> Calibrators<br />

Carbamazepine Calibrator, 5 level series<br />

Digoxin Calibrator, 6 level series<br />

Digitoxin Calibrator, 6 level series<br />

Gentamicin Calibrator, 5 level series<br />

Phenytoin Calibrator, 5 level series<br />

Phenobarbital Calibrator, 6 level series<br />

Theophylline Calibrator, 6 level series<br />

Valproic Acid Calibrator, 6 level series<br />

>>> Controls<br />

TDM Control (Acetoaminiphen, Amikacin, Carbamazepine*, Digoxin*, Gentamicin*, Lidocaine, NAPA, Phenobarbital*,<br />

Phenytoin*, Primidone, Procainamide, Quinidine, Salicylate, Theophylline*, Tobramycin, Valproic Acid*,<br />

Vancomycin)<br />

* evaluated for DIALAB reagents<br />

6 for more details >>> www.dialab.at


DOA (Drugs of abuse)<br />

liquid Immunoassays<br />

Liquid Reagents ”ready to use“<br />

>>> Reagents (liquid)<br />

Amphetamines (AMP), urine<br />

Barbiturates (BAR), urine<br />

Benzodiazepines (BZO), urine<br />

Cannabinoides (THC), urine<br />

Cocaine (COC), urine<br />

Cotinine (COT), urine<br />

Ecstasy (MDMA), urine<br />

Methadone (MTD), urine<br />

Morphine (MOR), urine<br />

Phencyclidine (PCP), urine<br />

Propoxyphene (PXP), urine<br />

>>> Calibrators / Controls (liquid)<br />

Amphetamines Cal./Ctrl. Set<br />

Barbiturates Cal./Ctrl. Set<br />

Benzodiazepines Cal./Ctrl. Set<br />

Cannabinoides Cal./Ctrl. Set<br />

Cocaine Cal./Ctrl. Set<br />

Cotinine Cal./Ctrl. Set<br />

Ecstasy Cal./Ctrl. Set<br />

Methadone Cal./Ctrl. Set<br />

Morphine Cal./Ctrl. Set<br />

Phencyclidine Cal./Ctrl. Set<br />

Propoxyphene Cal./Ctrl. Set<br />

for more details >>> www.dialab.at 7


DIAQUICK RAPID TESTS<br />

>>> Drugs of Abuse (DOA) in Urine (competitive assays)<br />

Single Parameter Tests:<br />

Amphetamine (AMP) Cassette<br />

Amphetamine (AMP) Dipstick<br />

Barbiturate (BAR) Cassette<br />

Barbiturate (BAR) Dipstick<br />

Benzodiazepine (BZO) Cassette<br />

Benzodiazepine (BZO) Dipstick<br />

Buprenorphine (BUP) Cassette<br />

Cocaine (COC) Cassette<br />

Cocaine (COC) Dipstick<br />

Marihuana (THC) Cassette<br />

Marihuana (THC) Dipstick<br />

MDMA Cassette<br />

MDMA Dipstick<br />

Methadone (MTD) Cassette<br />

Methadone (MTD) Dipstick<br />

Methamphetamine (MET) Cassette<br />

Methamphetamine (MET) Dipstick<br />

Morphine (MOP) Cassette<br />

Morphine (MOP) Dipstick<br />

Opiates (OPI) Cassette<br />

Oxycodone (OXY) Cassette<br />

Phencyclidine (PCP) Dipstick<br />

Propoxyphene (PPX) Cassette<br />

Tricyclic Antidepressants (TCA)<br />

Cassette<br />

Tricyclic Antidepressants (TCA)<br />

Dipstick<br />

Multi Parameter Panels:<br />

Multi-3 Drug Panel (MOP, COC, BZO)<br />

Multi-4 Drug Panel (MOP, COC, THC, AMP)<br />

Multi-5/3 Drug Panel (AMP, THC, COC, MET, MOP)<br />

Multi-5/6 Drug Panel (AMP, BZO, COC, THC, MOP)<br />

Multi-6 Drug Panel (MTD, MET, BZO, COC, MOP, THC)<br />

Multi-6/1 Drug Panel (AMP, MET, BZO, COC, MOP, THC)<br />

Multi-10 Drug Panel (AMP, MET, MDMA, COC, MOP, BAR, BZO,<br />

MTD, TCA, THC)<br />

Multi-10/1 Drug Panel (BUP, AMP, MET, MDMA, COC, MOP,<br />

BAR, BZO, MTD, THC)<br />

Multi-10/2 Drug Panel (COC, AMP, OPI, MDMA, MOP, BAR,<br />

BZO, MTD, TCA, THC)<br />

Multi-10/3 Drug Panel (AMP, BZO, THC, COC, MTD, OPI,<br />

MDMA, MOP, TCA, PCP)<br />

Multi-10/4 Drug Panel (AMP, BZO, THC, COC, MTD, OPI, BAR,<br />

MDMA, MET, BUP)<br />

Multi-10/5 Drug Panel (AMP, BZO, THC, COC, MTD, BAR, MET,<br />

MOP, TCA, BUP)<br />

Multi-10/6 Drug Panel (AMP, BZO, THC, COC, MTD, BAR, MET,<br />

MOP, TCA, PCP)<br />

Multi-10/7 Drug Panel (AMP, BZO, THC, COC, MTD, OPI, BAR,<br />

MET, TCA, PCP)<br />

DOA Multi-6 Cup (AMP, MET, BZO, COC, MOP, THC)<br />

Multi-6 drug testing panel combined with cup and urine<br />

temperature control<br />

CUT-OFF-VALUES<br />

AMP<br />

BAR<br />

BUP<br />

BZO<br />

COC<br />

1.000 ng/ml<br />

300 ng/ml<br />

10 ng/ml<br />

300 ng/ml<br />

300 ng/ml<br />

MDMA<br />

MET<br />

MOP<br />

MTD<br />

OPI<br />

500 ng/ml<br />

1,000 ng/ml<br />

300 ng/ml<br />

300 ng/ml<br />

2,000 ng/ml<br />

OXY<br />

PCP<br />

PPX<br />

TCA<br />

THC<br />

100 ng/ml<br />

25 ng/ml<br />

300 ng/ml<br />

1,000 ng/ml<br />

50 ng/ml<br />

>>> Urine Adulteration Tests<br />

Drug Adulteration Strip 6, colorimetric test<br />

>>> DOA Touch Tests (competitive assays)<br />

DOA Multi-6 High Sensitivity Touch Test<br />

(AMP, COC, THC, MET, MOP, PCP)<br />

DOA Amphetamine Touch Test<br />

DOA Cocaine Touch Test<br />

DOA Methamphetamine Touch Test<br />

DOA Morphine Touch Test<br />

8 for more details >>> www.dialab.at


DIAQUICK RAPID TESTS<br />

>>><br />

DOA Saliva Tests<br />

DOA Multi-6 Saliva (AMP, COC, THC, MET, OPI, PCP)<br />

Alcohol Saliva Strips<br />

DOA Multi-6/1 Saliva (AMP, COC, THC, MET, OPI, MTD)<br />

>>> Pregnancy/Fertility<br />

hCG Cassette (urine)<br />

hCG Dipstick (urine)<br />

hCG Combo Cassette (urine/serum)<br />

hCG Combo Dipstick (urine/serum)<br />

hCG Dipstick for Home Use (urine)<br />

LH Cassette (urine)<br />

LH Dipstick (urine)<br />

LH Dipstick for Home Use (urine)<br />

LH Cassette for Home Use (urine)<br />

>>> Tumor Markers<br />

AFP Cassette (serum/plasma/whole blood)<br />

CEA Cassette (serum/plasma/whole blood)<br />

FOB Cassette (human fecal occult blood)<br />

PSA Cassette (serum/plasma/whole blood)<br />

>>> Cardiac Markers >>> Diabetes<br />

CRP Dipstick (whole blood)<br />

Troponin I Cassette (serum/plasma/whole blood)<br />

Microalbumin Dipstick (urine)<br />

>>> Infectious Diseases<br />

Chlamydia trachomatis Cassette<br />

(endocervical/urethral/urine/ocular samples)<br />

Dengue Ab Cassette (serum/plasma/whole blood)<br />

H.pylori Cassette (serum/plasma/whole blood)<br />

H5 AIV Ag Cassette (in avian feces & throat swabs)<br />

HBsAb Cassette (serum/plasma)<br />

HBsAb Dipstick (serum/plasma)<br />

HBsAg Cassette (serum/plasma)<br />

HBsAg Dipstick (serum/plasma)<br />

HBsAg Cassette (serum/plasma/whole blood)<br />

HCV Ab Cassette (serum/plasma)<br />

HCV Ab Cassette (serum/plasma/whole blood)<br />

HIV Triline Cassette (serum/plasma/whole blood)<br />

HIV Ab Cassette (serum/plasma)<br />

HIV Ab Cassette (serum/plasma/whole blood)<br />

Malaria P. falciparium Cassette (whole blood)<br />

Mononucleosis Cassette (serum/plasma/whole<br />

blood)<br />

Strep.A Cassette (throat swab samples)<br />

Strep.A Dipstick (throat swab samples)<br />

Syphilis Ab Cassette (serum/plasma/whole blood)<br />

H.pylori Stool Cassette (stool)<br />

For more detailed information about our Rapid Tests<br />

please refer to our special “DIAQUICK Rapid Tests” brochure.<br />

for more details >>> www.dialab.at<br />

9


ELISA TESTS<br />

Microwell Method<br />

>>> Infectious Diseases: Aids, Hepatitis<br />

HBcAb, cut-off<br />

HBcIgM, cut-off<br />

HBeAb, cut-off<br />

HBeAg, cut-off<br />

HBsAb, cut-off<br />

HBsAb, quantitative<br />

HBsAg, cut-off<br />

HCV Ab, cut-off<br />

HIV 1&2 Ab, cut-off<br />

HIV 1&2 Ag/Ab, cut-off<br />

HAV IgG, cut-off<br />

HTLV 1&2 Ab, cut-off<br />

HAV IgM, cut-off<br />

>>> Infectious Diseases: Torch<br />

CMV IgG, quantitative<br />

CMV IgM, cut-off<br />

HSV 1 IgG, quantitative<br />

HSV 1 IgM, cut-off<br />

HSV 1&2 IgG, quantitative<br />

HSV 1&2 IgM, cut-off<br />

HSV 2 IgG, quantitative<br />

HSV 2 IgM, cut-off<br />

Rubella IgG, quantitative<br />

Rubella IgM, cut-off<br />

Toxoplasma IgA, cut-off<br />

Toxoplasma IgG, quantitative<br />

Toxoplasma IgM, cut-off<br />

10 for more details >>> www.dialab.at


ELISA TESTS<br />

Microwell Method<br />

>>> Other Infectious Diseases<br />

Adenovirus IgA, cut-off *<br />

Adenovirus IgG, cut-off *<br />

Adenovirus IgM, cut-off *<br />

Brucella IgA, cut-off *<br />

Brucella IgG, cut-off *<br />

Brucella IgM, cut-off *<br />

Chlamydia PLT IgA, cut-off *<br />

Chlamydia PLT IgG, cut-off *<br />

Chlamydia PLT IgM, cut-off *<br />

Chlamydia pneumoniae IgA, cut-off *<br />

Chlamydia pneumoniae IgG, cut-off *<br />

Chlamydia pneumoniae IgM, cut-off *<br />

Chlamydia trachomatis IgA, cut-off *<br />

Chlamydia trachomatis IgG, cut-off *<br />

Chlamydia trachomatis IgM, cut-off *<br />

EBV EBNA IgA, cut-off *<br />

EBV EBNA IgG, cut-off *<br />

EBV EBNA IgM, cut-off *<br />

EBV IgA, cut-off *<br />

EBV IgG, cut-off *<br />

EBV IgM, cut-off *<br />

EBV VCA IgA, cut-off *<br />

EBV VCA IgG, cut-off *<br />

EBV VCA IgM, cut-off *<br />

H5-HA(Ab), cut-off<br />

H5-HA(Ag), cut-off<br />

H. pylori IgA, cut-off *<br />

H. pylori IgG, cut-off *<br />

H. pylori IgM, cut-off *<br />

Legionella pn. IgA, cut-off *<br />

Legionella pn. IgG, cut-off *<br />

Legionella pn. IgM, cut-off *<br />

Measles IgA, cut-off *<br />

Measles IgG, cut-off *<br />

Measles IgM, cut-off *<br />

Mumps IgA, cut-off *<br />

Mumps IgG, cut-off *<br />

Mumps IgM, cut-off *<br />

Mycoplasma pn. IgA, cut-off *<br />

Mycoplasma pn. IgG, cut-off *<br />

Mycoplasma pn. IgM, cut-off *<br />

RSV IgA, cut-off *<br />

RSV IgG, cut-off *<br />

RSV IgM, cut-off *<br />

Syphilis IgG/IgM, cut-off<br />

VZV IgA, cut-off *<br />

VZV IgG, cut-off *<br />

VZV IgM, cut-off *<br />

*quantitative detection upon request<br />

for more details >>> www.dialab.at 11


ELISA TESTS<br />

Microwell Method<br />

>>> Autoimmune Diseases<br />

AMA M2, quantitative<br />

ANA 9 Line Immunoblot 08 / 16, semi quantitative<br />

ANA Combi 8, cut-off<br />

ANA Detect, cut-off<br />

ANA Screen 8, semiquantitative<br />

ANCA combi, cut-off<br />

ANCA Screen, cut-off<br />

Anti--Fodrin, quantitative<br />

Anti-Annexin V, quantitative<br />

Anti--2 Glycoprotein IgG/IgM, quantitative<br />

Anti--2-Glycoprotein IgA, quantitative<br />

Anti--2-Glycoprotein Screen, semi quantitative<br />

Anti-BPI, quantitative<br />

Anti-Cardiolipin IgA, quantitative<br />

Anti-Cardiolipin IgG & IgM, quantitative<br />

Anti-Cardiolipin Screen, quantitative<br />

Anti-Cathepsin G, quantitative<br />

Anti-Centromer B, quantitative<br />

Anti-CRA, quantitative<br />

Anti-dsDNA IgA, quantitative<br />

Anti-dsDNA IgG, quantitative<br />

Anti-dsDNA IgM, quantitative<br />

Anti-dsDNA Screen, quantitative<br />

Anti-Elastase, quantitative<br />

Anti-GBM, quantitative<br />

Anti-Histone, quantitative<br />

Anti-Intrinsic Factor, quantitative<br />

Anti-Lactoferrin, quantitative<br />

Anti-Lysozyme, quantitative<br />

Anti-MPO, quantitative<br />

Anti-Nukleosomen, quantitative<br />

Anti-Parietal Cell, quantitative<br />

Anti-Phosphatidic Acid IgG/IgM, quantitative<br />

Anti-Phosphatidyl Inositol IgG/IgM, quantitative<br />

Anti-Phosphatidyl Serine IgG/IgM, quantitative<br />

Anti-Phospholipid Screen, quantitative<br />

Anti-PR3, quantitative<br />

Anti-Prothrombin, IgA, quantitative<br />

Anti-Prothrombin, IgG/IgM, quantitative<br />

Anti-Prothrombin, Screen, quantitative<br />

Anti-RIB-P, quantitative<br />

Anti-RNP 70, quantitative<br />

Anti-RNP/Sm, quantitative<br />

Anti-Scl-70, quantitative<br />

Anti-Sm, quantitative<br />

Anti-SS-A (Ro) 52 kD, quantitative<br />

Anti-SS-A (Ro) 52/60 kD, quantitative<br />

Anti-SS-A (Ro) 60 kD, quantitative<br />

Anti-SS-B (La), quantitative<br />

Anti-ssDNA, quantitative<br />

Anti-Transglutaminase IgA, quantitative<br />

Anti-Transglutaminase IgG, quantitative<br />

ASCA, quantitative<br />

Dnase Activity, quantitative<br />

ENA 4 Profile, semiquantitative<br />

ENA 6 Combi, quantitative<br />

ENA 6 Screen, cut-off<br />

ENA-6 Profile, semiquantitative<br />

Gastro 5 Line 08/16, semiquantitative<br />

Gliadin Ab (IgA), quantitative<br />

Gliadin Ab (IgG), quantitative<br />

Jo-1-Ab, quantitative<br />

Nucleo-9-Line 08/16, semiquantitative<br />

Rheumatoid Factor IgA, quantitative<br />

Rheumatoid Factor IgG, quantitative<br />

Rheumatoid Factor IgM, quantitative<br />

Rheumatoid Factor Screen, quantitative<br />

ThromboCombo, quantitative<br />

12 for more details >>> www.dialab.at


ELISA TESTS<br />

Microwell Method<br />

>>> Thyroid<br />

Anti-TG, quantitative<br />

Anti-TPO, quantitative<br />

FT3, quantitative<br />

FT4, quantitative<br />

T3, quantitative<br />

T4, quantitative<br />

TG, quantitative<br />

TSH, quantitative<br />

>>> Steroids<br />

17--OH-Progesterone, quantitative<br />

17--Estradiol, quantitative<br />

Androstenedione, quantitative<br />

Cortisol, quantitative<br />

DHEA-S, quantitative<br />

Free Testosterone, quantitative<br />

Progesterone, quantitative<br />

SHBG, quantitative<br />

Testosterone, quantitative<br />

Total Estradiol, quantitative<br />

Unconjugated Estriol, quantitative<br />

>>> Fertility<br />

-hCG, quantitative<br />

LH, quantitative<br />

FSH, quantitative<br />

Prolactin, quantitative<br />

>>> Tumor Markers<br />

AFP, quantitative<br />

Ferritin, quantitative<br />

Free PSA, quantitative<br />

PSA, quantitative<br />

>>> Others<br />

-2-Microglobulin, quantitative<br />

Anti-Insulin, quantitative<br />

Microalbumin, quantitative<br />

for more details >>> www.dialab.at 13


COAGULATION<br />

AND FIBRINOLYSIS<br />

>>> Thrombin Time (TT)<br />

Bovine Thrombin (10NIH) lyo., clotting assay<br />

>>> Factor Assays<br />

Factor II Deficient Plasma, lyo., clotting assay<br />

Factor V Deficient Plasma, lyo., clotting assay<br />

Factor VII Deficient Plasma, lyo., clotting assay<br />

Factor VIII Deficient Plasma, lyo., clotting assay<br />

Factor IX Deficient Plasma, lyo., clotting assay<br />

Factor X Deficient Plasma, lyo., clotting assay<br />

Factor XI Deficient Plasma, lyo., clotting assay<br />

Factor XII Deficient Plasma, lyo., clotting assay<br />

>>> Control Plasmas<br />

Normal Coagulation Control Plasma, lyo., for PT, APTT and FIB assays<br />

Abnormal Coagulation Control Plasma, lyo., for PT, APTT and FIB assays<br />

>>> Reference Plasmas<br />

Normal Coagulation Reference Plasma, lyo.,<br />

assayed for PT, APTT, FIB, Factors, Plasminogen, Ristocetin, Protein C, Protein S, Antithrombin III, Alpha-2-Antiplasmin<br />

Abnormal Coagulation Reference Plasma, lyo.,<br />

assayed for PT, APTT, FIB, Factors, Plasminogen, Ristocetin, Protein C, Protein S, Antithrombin III, Alpha-2-Antiplasmin<br />

14 for more details >>> www.dialab.at


COAGULATION<br />

AND FIBRINOLYSIS<br />

>>> Prothrombin Time (PT)<br />

Thromboplastin lyo (ISI 1.6 – 2.0), clotting assay<br />

Thromboplastin-S lyo (ISI 1.0 – 1.4), clotting assay<br />

Thromboplastin-S liquid (ISI ~ 1.8), clotting assay<br />

>>> Activated Partial Thromboplastin Time (APTT)<br />

APTT -S,<br />

particle activated, clotting assay<br />

Calcium Chloride 0.020M, for APTT<br />

Calcium Chloride 0.025M, for APTT<br />

>>> Fibrinogen (FIB)<br />

Fibrinogen Kit, bovine thrombin, normal coag. ctrl. plasma, coag. ref. plasma abnormal, IBS; clotting assay<br />

Fibrinogen liquid, bovine thrombin (80 NIH), clotting assay<br />

Fibrinogen lyo., bovine thrombin (100 NIH), clotting assay<br />

IBS, diluent for fibrinogen and coagulation factor assays<br />

Kaolin Suspension, for determination of FIB on competitors’ coagulometers<br />

>>> D-Dimer Manual Test<br />

D-Dimer Latex Agglutination Kit, DD latex, DD ctrl. pos., DD ctrl. neg, DD buffer, test cards<br />

>>> D-Dimer for Automated Systems<br />

(Hitachi 911 and DIAchrom C4combi)<br />

D-Dimer Calibration Kit, DD latex, reaction buffer, saline solution, cal.DD-0, cal DD-3200<br />

D-Dimer Control high<br />

D-Dimer Control low<br />

for more details >>> www.dialab.at 15


SEROLOGY<br />

Latex and Agglutination Tests<br />

>>> Latex- and Haemagglutination<br />

ASO (Anti-Streptolysin O), Latex Agglutination<br />

CRP (C-reactive Protein), Latex Agglutination<br />

hCG, Latex Agglutination<br />

IM (Infectious Mononucleosis), Latex Agglutination<br />

RF (Rheumathoid Factor), Latex Agglutination<br />

Toxoplasma gondii, Latex Agglutination (*)<br />

Waaler Rose, Haemagglutination<br />

(*) no CE<br />

>>> Bacterial Agglutination<br />

Brucella (B. abortus, B.melitensis, B.suis), Bacterial Agglutination<br />

Febrile Bacterial Kit (Brucella,Para AH, Para BH, Typhoid O, Typhoid H)<br />

Proteus OX19, (pos. & neg. control included), Bacterial Agglutination<br />

Proteus OX19 (P. vulgaris), Bacterial Agglutination<br />

Proteus OX2 (P. vulgaris), Bacterial Agglutination<br />

Proteus OXK (P. mirabilis), Bacterial Agglutination<br />

Rose Bengale, Bacterial Agglutination<br />

Salmonella paratyphi AH, Bacterial Agglutination<br />

Salmonella paratyphi AO, Bacterial Agglutination<br />

Salmonella paratyphi BH, Bacterial Agglutination<br />

Salmonella paratyphi BO, Bacterial Agglutination<br />

Salmonella paratyphi CH, Bacterial Agglutination<br />

Salmonella paratyphi CO, Bacterial Agglutination<br />

Salmonella typhi H, Bacterial Agglutination<br />

Salmonella typhi O, Bacterial Agglutination<br />

Polyvalent Neg. Control<br />

Polyvalent Pos. Control<br />

>>> Syphilis Tests<br />

Syphilis RPR, Carbon Agglutination<br />

Syphilis TPHA, Haemagglutination<br />

Syphilis VDRL, Liquid Complex Agglutination<br />

16 for more details >>> www.dialab.at


BLOODGROUPING<br />

AND RHESUS TYPING<br />

Liquid Reagents ”ready to use“<br />

>>> ABO Typing<br />

Anti-A, monoclonal, clone 9113D10<br />

Anti-A 1 Lectin, Dolichos Biflorus<br />

Anti-B, monoclonal, clone 9621A8<br />

Anti-A,B, monoclonal, clones 152D12 + 9113D10<br />

>>> Rhesus Typing<br />

Anti-D (IgM/IgG), monoclonal, clones RUM-1 + MS-26<br />

Anti-C,D,E, monoclonal, clones 388F3 + RUM-1 + MS-258<br />

Anti-C, monoclonal, clone MS-24<br />

Anti-E, monoclonal, clone MS-258<br />

Anti-c, monoclonal, clone MS-33<br />

Anti-e, monoclonal, clones MS-16 + MS-63<br />

>>> Others<br />

Anti-HG (Anti-Human Globulin / Coombs Reagent), polyspecific (anti-IgG), monoclonal (anti-C3d)<br />

BSA (Bovine Serum Albumin) 22%, for potentiating serological reactions<br />

BSA (Bovine Serum Albumin) 30%, for potentiating serological reactions<br />

LISS (Low Ionic Strength Solution), for potentiating serological reactions<br />

PAPAIN, for specific serological studies<br />

Other blood grouping and rhesus typing reagents are available on request.<br />

for more details >>> www.dialab.at 17


URINE STRIPS<br />

URINE STRIP ANALYSER<br />

>>> Urine Strips<br />

Urine Strip 1<br />

Glucose<br />

Urine Strip 2<br />

Glucose, Ketones<br />

Urine Strip 3A<br />

Glucose, pH, Protein<br />

Urine Strip 3B<br />

Glucose, Ketones, Ascorbic Acid<br />

Urine Strip 4<br />

Glucose, Ketones, pH, Protein<br />

Urine Strip 4SG<br />

Glucose, Specific Gravity, pH, Protein<br />

Urine Strip 9<br />

Urobilinogen, Glucose, Bilirubin, Ketones, Spec.<br />

Grav., Blood, pH, Protein, Nitrite<br />

Urine Strip 10A*<br />

Urobilinogen, Glucose, Bilirubin, Ketones, Spec.<br />

Grav., Blood, pH, Protein, Nitrite, Ascorbic Acid<br />

Urine Strip 10C<br />

Urobilinogen, Glucose, Bilirubin, Ketones, Spec.<br />

Grav., Blood, pH, Protein, Nitrite, Leucocytes<br />

Urine Strip 11<br />

Urobilinogen, Glucose, Bilirubin, Ketones, Spec.<br />

Grav., Blood, pH, Protein, Nitrite, Leucocytes,<br />

Ascorbic Acid<br />

* Urine Strip 10 A: available on request for a minimum order quantity of 3000 vials or more.<br />

>>> Urine Strip Analyser<br />

General Features<br />

> Numeric keypad<br />

> Worklist downloading capability<br />

> Four-row LCD display<br />

> Deck shape designed<br />

> Protection against contamination<br />

> Closed waste-tray<br />

> Easy to clean<br />

> Easy to operate<br />

Technical Features<br />

> Methodology: reflectance photometer<br />

> Wavelengths: 460, 550, 650 nm<br />

> Detection: CCD image processing<br />

> Max. throughput: 500 strip/hour (theoretical)<br />

> Memory: last 1000 results<br />

> Display: 4 x 24 character LCD<br />

> Printer: 57 mm thermal printer (2 lines/sec)<br />

> Size: 480 x 290 x 165 mm<br />

> Weight: 10 kg<br />

> External adapter: 7,5 V DC / 3 A<br />

> Power consumption: max 20 W<br />

18 for more details >>> www.dialab.at


VACOLLECT<br />

>>> Vacuum Tubes<br />

Vacollect 3 ml<br />

Vacollect 5 ml<br />

Vacollect 7 ml<br />

Vacollect 3 ml<br />

Vacollect 5 ml<br />

Vacollect 7 ml<br />

Vacollect 3 ml<br />

Vacollect 5 ml<br />

Vacollect 7 ml<br />

Vacollect 3 ml<br />

Vacollect 5 ml<br />

Vacollect 7 ml<br />

Plain<br />

Plain<br />

Plain<br />

EDTA k2<br />

EDTA k2<br />

EDTA k2<br />

EDTA k3<br />

EDTA k3<br />

EDTA k3<br />

Heparin sodium<br />

Heparin sodium<br />

Heparin sodium<br />

Vacollect 1.8 ml Sodium citrate 1:9<br />

Vacollect 2.7 ml Sodium citrate 1:9<br />

Vacollect 4.5 ml Sodium citrate 1:9<br />

Vacollect 3 ml<br />

Vacollect 5 ml<br />

Vacollect 7 ml<br />

Vacollect 3 ml<br />

Vacollect 5 ml<br />

Vacollect 1.6ml<br />

Vacollect 2.4ml<br />

Vacollect 1.6ml / glass<br />

Microtubes 0.5ml<br />

Fluoride oxalate<br />

Fluoride oxalate<br />

Fluoride oxalate<br />

GEL<br />

GEL<br />

Sodium citrate 1:4(ESR)<br />

Sodium citrate 1:4(ESR)<br />

Sodium citrate 1:4(ESR)<br />

Plain, EDTA k3 or Hep.Lithium<br />

>>> Needles and Holder<br />

Blood Collection Needle 20G<br />

Blood Collection Needle 21G<br />

Holder for Blood Collection Needle<br />

for more details >>> www.dialab.at 19


CLINICAL ANALYZER<br />

>>> AUTOLYZER 600<br />

Stand-alone Clinical Analyzer<br />

For Clinical Chemistry, Immunoturbidimetry and Electrolytes<br />

Throughput<br />

up to 600 tests / hour<br />

up to 720 tests / hour (with ISE unit)<br />

NOW AVAILABLE >>> SYSTEM PACKS<br />

> The closed System works with bar-coded reagent packs<br />

> Main advantages: > No application procedure needed<br />

> Less adjustment<br />

> Reagent prefilled in system bottles<br />

> Barcode<br />

20 for more details >>> www.dialab.at


Reagents<br />

> Up to 72 cooled positions<br />

> Maximum number of simultaneous methods: 48<br />

> Reagent volume programmable:<br />

First reagent: 0 – 700 µl<br />

Second reagent: 0 – 450 µl<br />

Typical volume: 180 µl<br />

Total volume (Sample + Reagents) up to 700 µl<br />

> Reagents can be accommodated in either full size vials<br />

or split vials for two reagent methods.<br />

> Vial volumes are: 25, 40 and 70 ml.<br />

Samples<br />

> 95 positions in five segments<br />

> Additional segment for STATS, standards and controls<br />

> Sample volume: 2 – 100 µl in steps of 0.2 µl.<br />

Sampling System<br />

> 2 probes<br />

> Pre-heater in both probes<br />

> Capacitive level sensor<br />

Reaction Trays<br />

> 2 Trays: total 160 cuvettes of 0.6 cm light path<br />

> 2 cuvette washing units<br />

Analysis Modes<br />

> Methods with 1, 2 or 3 reagents<br />

> End point with sample blank or reagent blank<br />

> Kinetics (0 and 1 st order)<br />

> Fixed point<br />

> Turbidimetry<br />

> Calibration curves with up to 10 standards<br />

> Programmed pre-dilution<br />

> Automatic dilution of high limit values<br />

> Automatic repetition of abnormal low values<br />

> Prozone check<br />

> Profiles, batches, STAT procedures<br />

> Priority per sample (profile) or reagent (batch)<br />

Water consumption<br />

> Approximately 4 ml/analysis<br />

Data Management<br />

> Windows based Software<br />

> Interface LIMS: bi-directional RC 232 C, According to<br />

ASTM 1394 requirements<br />

Optical System<br />

> Double beam, double mode for reading in two reaction<br />

trays simultaneously<br />

> Wavelengths: 340, 380, 405, 450, 490, 505, 550, 600,<br />

620, 650, 700 and 750 nm<br />

> Lamp: Halogen, 12 volts, 20 watts<br />

ISE Unit (optional)<br />

Power Supply<br />

> 85 to 240 VAC +/–10%; 43/65 Hz; 400 VA<br />

Dimensions / Weight<br />

> Stand alone system<br />

> Width: 100 cm; Height: 115 cm; Depth: 70 cm<br />

> 140 kg<br />

for more details >>> www.dialab.at 21


Sampling and<br />

Reagent Center<br />

> 48 positions sample tray<br />

> Sample volume range 2 –100 µl<br />

> 48 positions reagent tray.<br />

> Ambient or cooled<br />

> Single or dual reagent capabilities<br />

> From 180 µl reagent volume/test<br />

> Sample predilution<br />

Reaction tray<br />

> 80 positions reaction tray<br />

> 4 steps washing station<br />

> Water consumption: 2.5 ml/test<br />

Pipetting System<br />

> Reagent probe heater<br />

> Capacitive liquid level sensor<br />

> Washing system outside and inside<br />

the probe<br />

> Warning on mission or insuf ficient<br />

reagent or sample, collision<br />

Data Management<br />

> Multitasking Windows based Software<br />

> Bi-directional computer interface<br />

(acc. To ASTM 1394 requirements)<br />

> Unrestricted methods (open system) and<br />

unlimited patient data and method storage<br />

Analysis modes<br />

> End point with sample blank or reagent blank<br />

> Fast and two-point kinetics (zero and first order)<br />

> Priority selection by sample (profile) or by reagent (blank)<br />

> Use of calibration curve with up to 10 standards<br />

> Coagulation times b y turbidimetry<br />

> Immunoturbidimetry<br />

> Routine, batch, STAT procedures, profiles<br />

Throughput<br />

> Up to 240 tests / hour depending on configuration<br />

> Up to 360 tests / hour (with ISE)<br />

Power requirements<br />

> 85 – 230 VAC; 50/60 Hz; 400 W<br />

Optical System<br />

> Double beam photometer for bichromatic measurements<br />

> wavelengths: 340, 405, 450, 505, 550, 590, 650, 700 and 750 nm.<br />

> Light source: 6V – 20 W Halogen Lamp<br />

Optional<br />

> ISE Unit<br />

> Barcode reader<br />

Dimensions / Weight<br />

> 85 x 58 x 47 cm, 40 kg<br />

Languages<br />

> English, German, Spanish, Chinese, Portuguese,<br />

and other languages upon request<br />

Standards:<br />

> CE, ISO9001, EMC, IEC-61010-1<br />

for more details >>> www.dialab.at 23


PHOTOMETER DTN-410 / 410K<br />

>>> PHOTOMETER DTN-410<br />

Specifications<br />

> DTN-410 / 410K Photometer for Clinical Chemistry,<br />

Immunoturbidimetry, TDM and Coagulation<br />

> Analysis modes: Absorption / Concentration,<br />

Endpoint with and without reagent blank, Enzyme<br />

Kinetics with and without sample blank, Two-Point<br />

Kinetics, Immunoturbidimetry, Coagulation<br />

> 132 different tests programmable<br />

> Built-in aspiration system with thermostated flow<br />

microcell (30 µl) and sample recovery<br />

> Cuvette holder for standard (1000 µl)<br />

and semi-micro (500 µl) cuvette<br />

Optical System<br />

> Monochromator with interferential filters<br />

> Wavelength selection: automatic 9 positions filter<br />

wheel, 7 installed filters, 2 empty positions<br />

> Filter wheel (automatic): 340, 405 ,450, 505, 550,<br />

580 and 700 nm<br />

> Light source: Halogen lamp (12 V/20 W)<br />

> Absorption range: – 0.5 to 4.000 Abs<br />

> Wavelength range: from 340 nm to 1000 nm<br />

> Bandwidth:10 nm (+/–2)<br />

> Precision:+/–0.002 Abs<br />

> Linearity: better than +/–1.5 %from 0 to 1.500 Abs<br />

> Reading: monochromatic and bichromatic<br />

> Detector: Silicone photodiode<br />

Cuvette System<br />

> Metallic microflow<br />

cell (temperature<br />

control by<br />

Peltier system.<br />

Temperature<br />

variable, preadjusted<br />

25°C,<br />

Peristaltic pump<br />

30°C and 37°C) or<br />

Standard 10 mm x 10 mm cuvette holder for macro<br />

or semi-micro cuvettes.<br />

Aspiration System<br />

> Built-in peristaltic<br />

pump programmable,<br />

reversible for<br />

sample recovery.<br />

> Reaction volume:<br />

100 to 500 µl<br />

> Carryover: < 1.5%<br />

for sipping volume<br />

of 400 µl<br />

Printer<br />

> Thermal graphic 24 characters per line<br />

24 for more details >>> www.dialab.at


Analysis Mode Clinical Chemistry,<br />

Turbidimetry, TDM<br />

> Endpoint, Enzymatic, Two Point Kinetic<br />

> Sample readings in absorbance and concentration<br />

> Two types of chromatism: mono-and bichromatism<br />

> Filter wheel: 340, 405, 450, 505, 550, 580 and<br />

700 nm<br />

> Temperature: 20 – 40°C<br />

> Endpoint:<br />

– Sample and reagent blank possible with and<br />

without blank<br />

– Curve: up to 10 standards<br />

– Curve readjustment by one or two standards<br />

> Enzymatic (first order kinetic):<br />

– Standard or factor. Factor storage in all<br />

methods<br />

– Alarm on high substrate consumption:<br />

> Two-point kinetics:<br />

– Incubation up to 10 minutes. Measure time<br />

from 15 to 600 seconds<br />

Analysis Mode Photometrics<br />

> Continuous reading of absorbance and concentration<br />

for one wavelength with volume and temperature<br />

selection.<br />

Analysis Mode Coagulation<br />

> Chronometric and colorimetric coagulation<br />

> Direct coagulation reading in cuvette at 405 nm<br />

wavelength<br />

> Absorbance plot for accurate threshold determination<br />

> Direct observation of the coagulation rate<br />

> Measurements in disposable 10 x 10 x 45-mm<br />

cuvettes<br />

> Typical procedure for PT: 200 µl of reagent and<br />

100 µl of sample<br />

> Typical procedure for APTT:100 µl of reagent,100 µl<br />

of sample and 100 µl of Calcium Chloride<br />

Operator’s interface<br />

> Membrane keyboard with 25 keys for functions and<br />

numeric entries<br />

Data presentation<br />

> Graphic LCD display, 20 x 40 characters with backlight<br />

> Display of sample number, absorbance, concentration,<br />

standard, factor, limits<br />

> Automatic result printouts<br />

Electrical Data<br />

> Interface: RS232C<br />

> Power requirements:110/230 VAC, 50/60 Hz, 50 W<br />

>>> PHOTOMETER DTN-410K<br />

Including a keyboard and an advanced software<br />

> Ability of creating a worklist<br />

> Indication of the patient ‘s name, sex, age and all methods to be measured<br />

> Patient ‘s report is printed<br />

> Real time reaction curve display<br />

> Big memory. Up to 2000 results<br />

for more details >>> www.dialab.at 25


DIAREADER<br />

>>> DIAREADER ELx800<br />

ELISA microplate reader<br />

Models<br />

> DIAREADER ELx800G<br />

measuring range from 400 nm to 750 nm for reading 24, 48 or 96-well plates<br />

> DIAREADER ELx800 UV<br />

extended measuring range from 340 nm to 750 nm for reading 24, 48 or 96-well plates<br />

> DIAREADER ELx800NB<br />

measuring range from 400 nm to 750 nm for reading 24, 48 and 96-well plates as well as 60, 72, 384-well<br />

plates and Terasaki plates<br />

> DIAREADER ELx800PC<br />

Includes the powerful software package Gen 5 ELISA for controlling the reader from the PC<br />

Specifications<br />

> Detection mode: absorbance<br />

> Endpoint, kinetic and well area scanning (via computer<br />

control)<br />

> 6, 12, 24, 48, 96-well plates (model ELx800NB also<br />

60, 72, 384-well plates and Terasaki plates)<br />

30 seconds for 96 wells single wavelength<br />

> Wavelength range: 400 – 750nm (model ELx800UV<br />

340 nm – 750 nm)<br />

> 5 positions filter wheel<br />

> Light source: Tungsten Halogen<br />

> Absorbance range: 0.000 – 3.000 Abs<br />

> Resolution: 0.001 Abs<br />

> Accuracy: +/–1% +/– 0.0010 Abs from 0 to 2 Abs<br />

> Linearity: +/–1% from 0 to 2 Abs, +/–3% from 2 to<br />

3 Abs<br />

> Standards: CE marked, meets EU in vitro<br />

Diagnostic Directive (IVD-D)<br />

Optional: Gen 5 ELISA<br />

> Basic data analysis and curve fitting<br />

> 32bit Windows application controls all DIALAB ®<br />

Absorbance Readers<br />

Electrical Data<br />

> Power: External, 24 volt power supply running from<br />

100 – 240 VAC, +/– 10%, 50 – 60 Hz<br />

> External outputs: RS 232 bidirectional serial interface,<br />

Parallel Centronics printer interface<br />

> Display: 2x24 LCD display<br />

Physical Data<br />

> Dimensions: 41,9 x 38,1 x 17,8 cm (D x W x H)<br />

> Weight: 8,4 kg<br />

26 for more details >>> www.dialab.at


DIAWASHER<br />

>>> DIAWASHER II ELx50<br />

Fully automatic microplate washer<br />

Specifications<br />

> Microplate types: flat, round or V-shaped wells<br />

> 384- (optional) or 96 well plates or strips<br />

> Wash, prime, rinse and aspirate programs<br />

> Up to 75 washer programs storable<br />

> Processing speed: < 130 secs<br />

(3 cycles, 300µl / well, 96 wells)<br />

> Wash cycles: 1 – 10<br />

> Volume range: 25 – 3000 µl / well<br />

> Dispense precision: < 2% CV typical<br />

> Residual volume: < 1 µl / well typical<br />

> Manifold: 8-channel (standard)<br />

optional: 12-channel, 16-channel patented Dual-Action manifold<br />

> Standards: CE marked, meets EU in vitro Diagnostic Directive (IVD-D)<br />

> Multi-speed shaking<br />

> Crosswise aspiration<br />

> Bottom washing<br />

> Over-flow protection<br />

> Standard package includes wash bottle, rinse bottle and waste bottle<br />

Electrical Data<br />

> 100 – 250 VAC, 50/60 Hz<br />

> RS232 Port for PC Interface<br />

Physical Data<br />

> Dimension instruments: 35 x 40 x 16,25 cm<br />

> Parcel gross weight incl. access: 8,9 kg<br />

for more details >>> www.dialab.at 27


COAGULOMETERS<br />

>>> Coagulometers – General Information<br />

Measuring Principle<br />

The DIAcheck ® series are highly sensitive photometers.<br />

A very intensive laser LED-Optic at 470 nm ensures accurate and precise results even<br />

when icteric or lipemic samples are used.<br />

During the actual test the system is searching for the best signal amplification, therefore<br />

it will support a wide range of different reagents (i.e.very turbid thromboplastins or very<br />

cleat reagents).<br />

Plasma and reagent absorb the transmitted laser light. The rate of absorbance is<br />

obtained by the detector and sent to the micro controller. The signal is analysed and the<br />

result is sent to the display and printer (optional)<br />

Features:<br />

> Open system instruments<br />

> Only quarter of the regular volumes necessary (e.g. PT: 25 µl sample plus 50 µl reagent)<br />

> Accurate and precise results<br />

> Autostart possible – measurement manually triggered by just adding reagent into the<br />

cuvette<br />

> Easy handling<br />

> Storage capacity for ISI-, normal- and calibration values<br />

> Results directly converted from seconds into INR (PT), “U” (units) g/L (Fibrinogen), % for<br />

Factors<br />

> Test-specific parameters are stored “on-board”<br />

> Approvals: TÜV-GS, CE-Mark, CSA, UL<br />

28 for more details >>> www.dialab.at


DIAcheck ® C1<br />

>>> DIAcheck ® C1<br />

Semiautomatic 1-channel coagulation analyzer<br />

for clotting methods<br />

Specifications<br />

> Tests: PT, PTT, TT, FIB, Fa-I (Factor Intrinsic),<br />

Fa-E (Factor Extrinsic)<br />

> Sample: Plasma<br />

> Volumes: quarter of regular volume Volume<br />

(e.g. PT: 25 µl sample +50 µl reagent)<br />

> Convertion of seconds in: INR, mg/dl, %<br />

> Language: Standard English, others on request<br />

> Optic cell: Photometer with pulsed 470nm LED’s,<br />

variable pulse modulation, variable detector<br />

amplification<br />

> Incubation block: 1 measuring, 6 samples, 2 reagent<br />

positions<br />

> Incubation temperature: 37,0°C +/– 0,2°C<br />

> Dimensions instrument (L x W x H):<br />

245 x 130 x 60 mm<br />

> Weight instrument w/o power supply: 0,51 kg<br />

> Parcel gross weight incl. accessories: 1,6 kg<br />

> Ambient temperature: 18 – 23°C<br />

> Power supply M1: input: 90 – 240 Vac, 50 – 60 Hz,<br />

output: 12V, 1,2A<br />

> Thermal printer: optional, external, serial printer with<br />

print-out of system parameters and results in all<br />

selected dimensions<br />

> RS232 interface<br />

> Autostart possible<br />

Standard Package<br />

1 Pc Diacheck C1<br />

1 Pc Power supply<br />

25 Pcs Single cuvettes<br />

5 Pcs Reagent tubes<br />

2 Pcs Reagent adaptors<br />

1 Pc Operation manual (English)<br />

1 Pc Warranty card<br />

for more details >>> www.dialab.at 29


DIAcheck ® C2<br />

>>> DIAcheck ® C2<br />

Semiautomatic 2-channel coagulation analyzer<br />

for clotting methods<br />

Specifications<br />

> Tests: PT, PTT, TT, FIB (Clauss and PT derived),<br />

Factor II, V, VII, VIII, IX, X, XI, XII, Fletcher, VT<br />

(Venom time), APCR, AT-III (clot), Protein C (clot),<br />

Protein S (clot), Heparin, STAT (PT/PTT)<br />

> Sample: Plasma<br />

> Volumes: quarter of regular volume (e.g. PT: 25 µl<br />

sample + 50 µl reagent)<br />

> Selectable dimensions (test dependent):<br />

E (Extinction), s, R, INR, %, U (mg/dL, g/L, U/ml,<br />

mg/L)<br />

> Language: English, German, French, Spanish,<br />

Italian, Portuguese<br />

> Optic cell: Photometer with pulsed 470nm LED’s,<br />

variable pulse modulation, variable dedector<br />

amplification<br />

> Incubation block: 6 x 2 double cuvette pre warming,<br />

2 measuring, 3 reagents pos.<br />

> Incubation temperature: 37°C +/– 0,5°C<br />

> Dimensions instrument (L x W x H):<br />

370 x 280 x 280 mm<br />

> Weight instrument w/o power supply: 2,0 kg<br />

> Parcel gross weight incl. accessories: 3,5 kg<br />

> Ambient temperature: 18 – 23°C<br />

> Power supply: input: 94 to 230 Vac, 50 to 60 Hz,<br />

output (max.): 40VA<br />

> Thermal printer: optional, external, serial printer with<br />

print-out of system parameters and results in all<br />

selected dimensions<br />

> Barcode scanner: optional<br />

> RS232 interface<br />

> Autostart possible<br />

Standard Package<br />

1 Pc DIAcheck C2<br />

1 Pc Power supply<br />

1 Pc Main cable<br />

25 Pcs Double cuvettes<br />

5 Pcs Reagent container<br />

1 Pc Magnetic stirrer<br />

1 Pcs Reagent adaptor<br />

1 Pc Pipette fastener<br />

1 Pc Operation manual<br />

1 Pc Warranty card<br />

1 Pc Installation report<br />

1 Pc Service report<br />

30 for more details >>> www.dialab.at


DIAcheck ® C4<br />

®<br />

>>> DIAcheck ® C4<br />

Semiautomatic 4-channel coagulation analyzer<br />

for clotting methods<br />

Specifications<br />

> Tests: PT, PTT, TT, FIB (Clauss and PT derived),<br />

Factor II, V, VII, VIII, IX, X, XI, XII, Fletcher, VT<br />

(Venom time), APCR, AT-III (clot), Protein C (clot),<br />

Protein S (clot), Heparin, STAT (PT/PTT)<br />

> Volumes: quarter of regular volume (e.g. PT: 25 µl<br />

sample + 50 µl reagent)<br />

> Selectable dimensions: E (Extinction), S, R, INR, %,<br />

U (mg/L, mg/dL, g/L)<br />

> Language: English, German, French, Spanish,<br />

Italian, Portuguese<br />

> Optic cell: Photometer with pulsed 470nm LED’s,<br />

variable pulse modulation, variable detector<br />

amplification<br />

> Incubation block: 12 x 2 double cuvettes prewarming,<br />

4 measuring, 3 reagents positions<br />

> Incubation temperature: 37°C +/– 0,5°C<br />

> Dimensions instrument (L x W x H):<br />

370 x 280 x 280mm<br />

> Weight instrument w/o power supply: 2,0 kg<br />

> Parcel gross weight incl. Access.: 3,5 kg<br />

> Ambient temperature: 18 – 23°C<br />

> Power supply: Input: 94 to 230 Vac, 50 to 60 Hz,<br />

Output (max.): 40VA<br />

> Thermal printer: optional, external, serial printer with<br />

print-out of system parameters and results in all<br />

selected dimensions<br />

> Barcode scanner: optional, up to 20 characters can<br />

be read, must support serial interface, set to 9600<br />

baud, 8 data, 1 stop, no parity powered with 5V<br />

over pin 9 of the RS232 interface of the analyzer<br />

> RS232 interface<br />

> Autostart possible<br />

Standard Package<br />

1 Pc Diacheck C4<br />

1 Pc Power supply<br />

1 Pc Main cable<br />

25 Pcs Double cuvettes<br />

5 Pcs Reagent containers<br />

1 Pc. Magnetic stirrer<br />

1 Pcs Reagent adaptors (22.5 mm)<br />

1 Pc Pipette fastener<br />

1 Pc Operation manual (English)<br />

1 Pc Warranty card<br />

1 Pc Installation report<br />

1 Pc Service report<br />

for more details >>> www.dialab.at 31


DIAchrom C4 combi<br />

>>> DIAchrom C4 combi<br />

Semiautomatic 4-channel coagulation analyzer<br />

for clotting and chromogenic substrate methods<br />

Specifications<br />

> Tests: PT, PTT, TT, FIB (Clauss and PT derived),<br />

Factor II, V, VII, VIII, IX, X, XI, XII, Fletcher,<br />

Plasminogen, VT (Venom time), APCR, AT-III,<br />

Protein C , Protein S, Heparin, STAT (2 x PT/2 x<br />

PTT), C1-Elastase, Alpha 2-Antiplasmin, PAI, tPA,<br />

µPA, Heptest, Lupus Anticoagulant, Factor XIII at<br />

340nm, APCR, D-Dimer and PT-B (whole blood<br />

PT) at 710 nm, research tests- free selectable parameters<br />

> Sample: plasma, whole blood (for the measurement<br />

of whole blood samples, a special filter of 710 nm<br />

has to be used)<br />

> Selectable dimensions: seconds, %, INR,<br />

dE (Slope/min), E (Extinction), Units (IU/mL, mg/dL,<br />

g/L)<br />

> Language: English, German, French, Spanish,<br />

Italian, Portuguese<br />

> Optic Cell: 4-channel optics with halogen lamp and<br />

light intensity control, 16 diff. filters possible, 3 OD<br />

max Range 0 – 2,5<br />

> Incubation block: 6 x 4 cuvettes prewarming,<br />

4 measuring, 5 reagents positions<br />

> Incubation temperature: 37°C +/– 0,2°C<br />

> Weight instrument w/o Power Supply: 3 kg<br />

> Parcel gross weight incl. access.: 5 kg<br />

> Ambient temperature: 18 – 23°C<br />

> Power supply: input: 47– 440 HZ, 85-264VAC, output:<br />

(max.) 60VA<br />

> Thermal printer: optional, external, serial printer with<br />

print-out of system parameters and results in all<br />

selected dimensions<br />

> Barcode scanner: optional<br />

> RS232 interface<br />

Standard Package<br />

1 Pc Diachrom C4 combi<br />

1 Pc Power supply<br />

1 Pc Main cable<br />

1 Pc Filter 405<br />

10 Pcs 4 position cuvettes<br />

10 Pcs Reagent containers<br />

4 Pc Magnetic stirrers<br />

1 Pcs Reagent adaptor (22.5 mm)<br />

1 Pc Printer cable<br />

1 Pc Operation manual (English)<br />

1 Pc Warranty card<br />

1 Pc Installation report<br />

1 Pc Service report<br />

> Dimensions Instrument (L x W x H):<br />

420 x 340 x 250 mm<br />

32 for more details >>> www.dialab.at


CONTACTS<br />

Managing Directors<br />

Murat Estelik<br />

Phone: +43-2236-660910-19<br />

e-mail: estelik@dialab.at<br />

Dipl. Ing. Marlene Ramsey<br />

Phone: +43-2236-660910-15<br />

e-mail: ramsey@dialab.at<br />

Murat Estelik<br />

Phone: +43-2236-660910-19<br />

e-mail: estelik@dialab.at<br />

Europe:<br />

Belarus, Moldavia, Russia, Ukraine<br />

Asia:<br />

whole continent except<br />

Bangladesh, India, Nepal, Sri Lanka<br />

Africa:<br />

north of Equator<br />

Area Managers<br />

Dipl. Ing. Edward Fidler<br />

Phone: +43-2236-660910-25<br />

e-mail: fidler@dialab.at<br />

Europe:<br />

Italy, Spain,Portugal<br />

Asia:<br />

Bangladesh, India, Nepal, Sri Lanka<br />

America:<br />

USA, Canada, South America,<br />

Central America<br />

Josef Pucher<br />

Phone: +43-2236-660910-18<br />

e-mail: pucher@dialab.at<br />

Europe:<br />

whole continent<br />

except Italy, Spain, Portugal<br />

Africa:<br />

south of Equator<br />

Product Managers<br />

Dipl. Ing. Marlene Ramsey<br />

Phone: +43-2236-660910-15<br />

e-mail: ramsey@dialab.at<br />

Head of Product Management<br />

Mag. Martin Herr<br />

Phone: +43-2236-660910-17<br />

e-mail: herr@dialab.at<br />

Blood Grouping<br />

Coagulation<br />

DOA liquid Immunoassays<br />

Urine Strips<br />

Mag. Simone Sturm<br />

Phone: +43-2236-660910-10<br />

e-mail: sturm@dialab.at<br />

ELISA<br />

Rapid Tests<br />

Serology<br />

Ing. Michal Prazak<br />

Phone: +43-2236-660910-36<br />

e-mail: prazak@dialab.at<br />

Applications<br />

Instruments<br />

Technical Support<br />

Dipl. Ing. Martina Wagner<br />

Phone: +43-2236-660910-16<br />

e-mail: wagner@dialab.at<br />

Clinical Chemistry<br />

Immunoturbidimetric Tests<br />

TDM<br />

for more details >>> www.dialab.at 33


Head Office: Austria<br />

IZ NÖ Süd<br />

Hondastrasse, Obj. M55<br />

2351 Wiener Neudorf<br />

Phone: +43 - 2236 - 66 09 10-0<br />

Fax: +43 - 2236 - 66 09 10-30<br />

e-mail: office@dialab.at<br />

www.dialab.at<br />

www.dialab.at<br />

Czech Republic<br />

DIALAB ® SPOL.SR.O.<br />

Namesti Osvoboditelu 1, CZ-153 00 Prague 5 Radotín<br />

Phone/Fax: ++420-2-579 10 255<br />

e-mail: office@dialab.cz<br />

www.dialab.cz<br />

Hungary<br />

DIALAB ® KFT<br />

Pasaréti út 31, H-1026 Budapest<br />

Phone: ++36-1-212 25 05<br />

Fax: ++36-1-355 73 70<br />

e-mail: dialab@mail.datanet.hu<br />

www.dialab.hu<br />

Serbia<br />

DIALAB ® Export – Import D.o.o.<br />

Carigradska 1<br />

11 008 Belgrade 12<br />

Serbia<br />

Phone: ++381-11-32 38 745<br />

Phone/Fax: ++381-11-32 42 777<br />

e-mail: dialab@sbb.co.yu<br />

DIALAB ® Produktion und Vertrieb<br />

von chemisch-technischen Produkten<br />

und Laborinstrumenten Gesellschaft m.b.H.<br />

DIALAB ® reserves the right to change specifications without prior notice as part of our continuous product improvement

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!