<strong>Pool</strong> <strong>dehumidification</strong> <strong>unit</strong> <strong>with</strong> <strong>heat</strong> <strong>pump</strong> <strong>HKG</strong>-SP-<strong>WP</strong><br />
Exhaust Outside Supply<br />
Return<br />
Technical data of <strong>HKG</strong>-SP- <strong>HKG</strong>-SP- <strong>HKG</strong>-SP-<br />
<strong>HKG</strong>-SP-<strong>WP</strong> <strong>WP</strong>-015 <strong>WP</strong>-023 <strong>WP</strong>-034<br />
nominal air volume flow rate m 3 /h 1500 2300 3400<br />
supply air volume flow rate m 3 /h 1500 2300 3400<br />
return air volume flow rate m 3 /h 1500 2300 3400<br />
range of use (1) referred to the water surface (2)<br />
private bath m 2 45 70 105<br />
public bath m 2 33 50 74<br />
<strong>dehumidification</strong> capacity in return air mode, 66 % volume flow <strong>with</strong> <strong>heat</strong> <strong>pump</strong> kg/h 8.4 11 16<br />
<strong>dehumidification</strong> capacity according to VDI 2089 at nominal air flow rate kg/h 10.5 16 24<br />
winter operation (outside air: -12 °C / 90 %; return air: 30 °C / 54 %)<br />
total energy recovery kW 17 26 39<br />
efficiency % 80 80 80<br />
winter outside air temperature after plate <strong>heat</strong> exchanger °C 21.3 21.5 21.3<br />
external pressure drop outside air duct Pa 100 150 200<br />
external pressure drop return air duct Pa 100 150 200<br />
external pressure drop supply air duct Pa 100 150 200<br />
external pressure drop exhaust air duct Pa 100 150 200<br />
sound power level at supply air canvas dB(A) 73 75 81<br />
sound power level at return air canvas dB(A) 73 75 80<br />
sound power level at outside air canvas dB(A) 66 68 74<br />
sound power level at exhaust air canvas dB(A) 69 71 77<br />
power demand of supply air fan including electronic commutation kW 0.45 0.85 1.8<br />
power demand of return air fan including electronic commutation kW 0.42 0.85 1.4<br />
nominal power of supply air fan including electronic commutation kW 0.5 1 2.15<br />
nominal power of return air fan including electronic commutation kW 0.5 1 2.15<br />
power demand of compressor kW 2.3 3.1 4.5<br />
total electric power demand kW 3.3 5.1 8.8<br />
nominal current supply air fan A 3.1 1.8 3.4<br />
nominal current return air fan A 3.1 1.8 3.4<br />
current demand of compressor A 10.3 5.4 8.4<br />
maximum total current A 16.5 9 15.2<br />
mains power 3-phases / N / PE 50 Hz V 230 400 400<br />
capacity of <strong>heat</strong>ing coil (at water temperatures 60/40 °C and <strong>heat</strong>ing from 18 °C to 34 °C) kW 8 12 18<br />
condensate drain of plate <strong>heat</strong> exchanger DN 40 40 40<br />
filter clas of return air filter EN 779 F7 F7 F7<br />
filter clas of outside air filter EN 779 F7 F7 F7<br />
panel thickness mm 30 30 30<br />
material class DIN 4102 A1 A1 A1<br />
<strong>heat</strong> transfer coefficient EN1886 T3 T3 T3<br />
thermal bridging factor EN1886 TB2 TB2 TB2<br />
(1) The given values are according to VDI 2089. We recommend to use these values as maximum values in order to enable efficient <strong>dehumidification</strong>.<br />
(2) Calculation based on pool water temperature of 28 °C and room air conditions of 30 °C / 54 % relative humidity.<br />
11/2010 - Alteration of construction reserved 9