1<br />
40<br />
TOPJOB ® @<br />
Disconnect and Fuse Terminal Blocks 6 (10) mm 2<br />
2006 Series<br />
0.5 - 6 (10) mm 2 1 AWG 20 - 8<br />
800 V/6 kV/3<br />
I N<br />
30 A<br />
Terminal block width 7.5 mm / 0.295 in<br />
L 13 - 15 mm / 0.55 in<br />
1 Conductor sizes: 0.25 – 4 mm 2 “s + f-st”;<br />
Push-in conductor sizes: 0.75 – 4 mm 2 “s” and<br />
0.75 – 2.5 mm 2 “insulated ferrule, 12 mm”<br />
0.2 - 6 (10) mm 2 1 AWG 20 - 8<br />
800 V/8 kV/3 2<br />
I N<br />
25/30 A 2<br />
Terminal block width 7.5 mm / 0.295 in<br />
L 13 - 15 mm / 0.55 in<br />
0.5 - 6 (10) mm 2 1 AWG 20 - 8<br />
500 V/6 kV/3<br />
I N<br />
30 A<br />
Terminal block width 15 mm / 0.59 in<br />
L 13 - 15 mm / 0.55 in<br />
3 Approvals 3 Approvals 3 Approvals<br />
12<br />
< 37 mm/1.46 in _><br />
<br />
(__ 32,9 mm/1.29 in _)<br />
<br />
<br />
<br />
<br />
<br />
< 38,2 mm/1.50 in _><br />
<br />
<br />
<br />
Color Item No. Pack. Unit<br />
2-conductor disconnect terminal block,<br />
with test point, orange disconnect link<br />
gray 2006-1671 25<br />
blue 2006-1674 25<br />
2-conductor through terminal block, same profile<br />
gray 2006-1601 25<br />
blue 2006-1604 25<br />
Item-Specific Accessories<br />
End and intermediate plate, 1 mm thick<br />
orange 2006-1692 100 (4x25)<br />
gray 2006-1691 100 (4x25)<br />
Item No. Pack. Unit Item No. Pack. Unit<br />
2-cond. fuse term. block for mini-automotive fuses,<br />
12 V, with blown fuse indication by LED,<br />
with test option, gray<br />
Circuit I 2006-1681/1000-429 25<br />
Circuit II 2006-1681/1000-449 25<br />
without blown-fuse indication, with test option<br />
gray 2006-1681 25<br />
End and intermediate plate, 1 mm thick<br />
orange 2006-1692 100 (4x25)<br />
gray 2006-1691 100 (4x25)<br />
Ground conductor disconnect terminal block, gray<br />
24 V AC/DC 2006-1671/1000-848 12<br />
48 V AC/DC 2006-1671/1000-849 12<br />
120 V AC/DC 2006-1671/1000-850 12<br />
230 V AC/DC 2006-1671/1000-851 12<br />
For application notes, see page 83.<br />
End and intermediate plate, 1 mm thick<br />
orange 2006-1692 100 (4x25)<br />
gray 2006-1691 100 (4x25)<br />
2006 Series Accessories Appropriate marking systems: WMB/Marking Strips/WMB Inline<br />
Push-in type jumper bar, insulated, I N<br />
41 A, light gray<br />
2-way 2006-402 50 (2x25)<br />
3-way 2006-403 50 (2x25)<br />
4-way 2006-404 50 (2x25)<br />
5-way 2006-405 50 (2x25)<br />
Push-in type jumper bar, insulated, I N<br />
41 A, light gray<br />
2-way 2006-402 50 (2x25)<br />
3-way 2006-403 50 (2x25)<br />
4-way 2006-404 50 (2x25)<br />
5-way 2006-405 50 (2x25)<br />
Push-in type jumper bar, insulated, I N<br />
41 A, light gray<br />
2-way 2006-402 50 (2x25)<br />
Push-in type jumper bar, insulated, I N<br />
41 A, light gray<br />
1 - 3 2006-433 50 (2x25)<br />
1 - 4 2006-434 50 (2x25)<br />
1 - 5 2006-435 50 (2x25)<br />
Protective warning marker, with high-voltage symbol,<br />
for 5 terminal blocks<br />
yellow 2006-115 100 (4x25)<br />
Test plug adapter, for test plug 4 mm Ø<br />
2009-174 100 (4x25)<br />
Testing tap, for max. 2.5 mm 2 /AWG 14<br />
2009-182 100 (4x25)<br />
Banana plugs, only for safety extra-low voltage (42 V)<br />
black 215-311 50<br />
red 215-212 50<br />
blue 215-711 50<br />
*Recommended overcurrent circuit breaker from ETA,<br />
Elektrotechnische Apparate GmbH, Postfach 1061,<br />
D-90514 Altdorf/Nürnberg<br />
Types 1170-02, 1621-21 or 1610-22, individual or<br />
block arrangement up to 25 A for conductor size 4 mm 2 /<br />
AWG 12 <br />
Push-in type jumper bar, insulated, I N<br />
41 A, light gray<br />
1 - 3 2006-433 50 (2x25)<br />
1 - 4 2006-434 50 (2x25)<br />
1 - 5 2006-435 50 (2x25)<br />
Disconnect plug for fuse terminal blocks, suitable<br />
when using the fuse terminal block<br />
as a disconnect terminal block<br />
orange 2006-401 100 (4x25)<br />
Blade-style fuses,<br />
acc. to DIN 72581-3c/ISO 8820<br />
(not offered by <strong>WAGO</strong>)<br />
Overcurrent circuit breaker*,<br />
thermal<br />
not offered by <strong>WAGO</strong><br />
Circuit I Circuit II<br />
Protective warning marker, with high-voltage symbol,<br />
for 5 terminal blocks<br />
yellow 2006-115 100 (4x25)<br />
WMB Multi marking system,<br />
10 strips with 10 markers per card,<br />
stretchable 5 – 5.2 mm<br />
plain 793-5501 50 (10x5)<br />
Insulated ferrules, extra long,<br />
for TOPJOB ® S terminal blocks,<br />
see page 195<br />
Operating tool with partially insulated shaft,<br />
type 3, (5.5 x 0.8) mm blade<br />
210-721 1<br />
2 Nominal voltage and current are given by the fuse or blown fuse indicator!<br />
3 Approvals are available online at: www.wago.com.