WNIP Mar Apr 19.2 Digital
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
12<br />
New inline analyser system for edible oil and fat processing<br />
<strong>19.2</strong><br />
Introducing the OPTIQUAD-EOF<br />
4050 W for the continuous inline<br />
measurement of free fatty acids<br />
(FFA), total polar material (TPM),<br />
peroxide value (POV), moisture<br />
or dirt. The optical spectroscopic<br />
analyser system is aimed at frying<br />
and other edible oil as well as fat<br />
applications.<br />
OPTIQUAD-EOF 4050 W<br />
measures directly in the pipe:<br />
analysis is achieved via an optical<br />
window mounted in a standard<br />
VARINLINE measuring section.<br />
The readings of FFA, TPM, POV<br />
moisture or dirt are provided<br />
instantly for process control or<br />
dynamic control loops via four<br />
4...20 mA outputs. Depending on<br />
the application, measurement of<br />
anisidine value (AV) and iodine<br />
value (IV) are possible. Compared<br />
to conventional laboratory<br />
methods used to obtain these<br />
values, OPTIQUAD-EOF 4050 W<br />
reduces the need for sampling,<br />
sample transport and handling,<br />
and the associated sources of error<br />
and costs.<br />
The optical spectroscopy<br />
analyzing method allows for a<br />
wide range of use in edible oil<br />
applications, such as oil extraction,<br />
oil refinement and frying processes<br />
up to oil recycling, as well as fat<br />
processing. For example, the<br />
continuous inline measurement<br />
of FFA content in frying oil helps to<br />
minimize the addition of fresh oil:<br />
the FFA value can be kept below<br />
a defined limit whilst allowing to<br />
maintain a high level of quality. It<br />
also provides a wide measuring<br />
range, e.g. 0…98% for FFA, and<br />
an accuracy of RMSEp: ±0,03%<br />
up to ± 1% FFA, depending on the<br />
measurement range.<br />
OPTIQUAD-EOF 4050 W<br />
spectroscopic analysis system<br />
consists of the analyser unit<br />
(protection rating IP65/NEMA4X)<br />
and the operating unit, an<br />
industrial PC with touch screen<br />
display for parameterisation and<br />
automatic calibration in a stainless<br />
steel housing (IP65/NEMA4X),<br />
optionally built into a switch<br />
cabinet. It uses up to four measuring<br />
methods (transmission, scattering,<br />
fluorescence and refraction)<br />
with up to 12 wavelengths<br />
from ultraviolet to infrared.<br />
The underlying calibration is<br />
calculated automatically from<br />
reference data specific to the<br />
application. OPTIQUAD-EOF 4050<br />
W is the successor of OPTIQUAD-<br />
FFA 4050 W.<br />
j.alexander@krohne.com<br />
New relative humidity probe that hands control to the user<br />
Michell Instruments has<br />
introduced the new<br />
HygroSmart HS3 advanced<br />
interchangeable relative<br />
humidity and temperature probe.<br />
It’s 100% configurable, giving<br />
users maximum flexibility. It<br />
also allows for alterations to RH<br />
measurements, to keep step with<br />
changes or developments in the<br />
process.<br />
Users can set the zero/span<br />
range, output signals and choose<br />
from five output parameters<br />
(including dew point). All these<br />
changes and settings are made on<br />
a PC via the application software.<br />
The unit can also be ordered<br />
directly from Michell with the<br />
probes fully configured to unique,<br />
individual specifications.<br />
The new probe ensures zero<br />
process downtime by keeping<br />
maintenance to a minimum<br />
with an interchangeable sensor.<br />
When recalibration is due, the<br />
old HygroSmart HS3 sensor is<br />
simply exchanged for a new,<br />
freshly calibrated one. This simple<br />
procedure allows for the probe to<br />
remain installed, and takes only a<br />
few seconds to carry out. Using the<br />
replaceable sensor ensures that<br />
the HygroSmart HS3 probe has a<br />
low life-time cost, when compared<br />
to fully disposable probes.<br />
Alternatively, minor calibration<br />
adjustments can be easily made<br />
on any installed HS3 probe, with a<br />
5-point digital trim adjustment via<br />
the application software to ensure<br />
maximum accuracy without<br />
needing to replace the sensor.<br />
Designed for demanding<br />
industrial conditions, the<br />
HygroSmart HS3 probe features<br />
a solid corrosion-resistant body,<br />
10 bar pressure sealing and IP67<br />
pressure rating. In addition it also<br />
has an accuracy of 0.8%RH, making<br />
it among the most accurate and<br />
reliable RH probes on the market.<br />
sales@instrotech.co.za<br />
Safe AS-I input module especially for light guard applications<br />
The new safe AS-i input<br />
module is designed for the<br />
connection of electro-sensitive<br />
protective equipment (ESPE) with<br />
electronic outputs to EN 61496-<br />
1. It is particularly suited for the<br />
connection of safe inductive<br />
sensors such as GM705S. Pulse<br />
pick-ups for the display of muting<br />
functions can be connected via<br />
M12 sockets.<br />
The integrated outputs<br />
ensure the connection of two<br />
signal lamps. The tried-andtested<br />
quick mounting avoids<br />
wiring faults. The AS-i flat cable<br />
can be connected from three<br />
different directions. There is one<br />
M12 connecting socket each for<br />
the transmitter, the receiver and<br />
the two signal outputs.<br />
Fail-safe sensors with a<br />
current consumption below 200<br />
mA can be operated on AC507S<br />
without auxiliary voltage. The<br />
LEDs indicate the status of the<br />
inputs and outputs and the<br />
communication.<br />
The new safe AS-i input<br />
module meets the requirements<br />
up to SIL3 according to EN 62061<br />
and PL e to EN 13849-1. In the<br />
event of a fault, the integrated<br />
communication monitoring<br />
switches the signal outputs off.<br />
info.za@ifm.com