20.06.2016 Views

Timken - Spherical Roller Bearing Solid-Block Housed Units

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SPHERICAL ROLLER BEARING SOLID-BLOCK HOUSED UNITS<br />

Engineering • SHAFTING • MISALIGNMENT • LUBRICATION<br />

<strong>Bearing</strong><br />

Number<br />

22208<br />

22209<br />

22210<br />

22211<br />

22212<br />

22213<br />

22214<br />

TABLE C-21. Amount of Float Per One Rotation<br />

of External Housing NuT<br />

Float<br />

mm<br />

in.<br />

1.270<br />

0.050<br />

1.270<br />

0.050<br />

1.270<br />

0.050<br />

1.270<br />

0.050<br />

1.270<br />

0.050<br />

2.108<br />

0.083<br />

2.108<br />

0.083<br />

<strong>Bearing</strong><br />

Number<br />

22215<br />

22216<br />

22217<br />

22218<br />

22219<br />

22220<br />

22222<br />

Float<br />

mm<br />

in.<br />

2.108<br />

0.083<br />

2.108<br />

0.083<br />

2.108<br />

0.083<br />

2.108<br />

0.083<br />

2.108<br />

0.083<br />

2.108<br />

0.083<br />

2.108<br />

0.083<br />

<strong>Bearing</strong><br />

Number<br />

22224<br />

22226<br />

22228<br />

23230<br />

23234<br />

Float<br />

mm<br />

in.<br />

2.108<br />

0.083<br />

2.108<br />

0.083<br />

2.108<br />

0.083<br />

2.108<br />

0.083<br />

2.108<br />

0.083<br />

– –<br />

– –<br />

Conversion from Fixed<br />

to Floating<br />

<strong>Housed</strong> unit bearings are easily converted from fixed to floating<br />

in the field (see the appropriate installation guide in this catalog<br />

for instructions). The following table will help you determine<br />

the amount of float for each bearing based on the number of<br />

revolutions the external housing nut is backed out.<br />

Misalignment<br />

Table C-22. Misalignment scale at ±1.5 degrees<br />

All spherical roller bearing housed units utilize self-aligning<br />

double-row spherical roller bearings. Because of this, the<br />

housed unit can accept up to ±1.5 degrees of misalignment. The<br />

performance life of our housed unit is not reduced while under<br />

misalignment conditions within these guidelines. It will accept<br />

both radial and thrust loads under static, oscillatory or dynamic<br />

load conditions.<br />

A<br />

m<br />

in.<br />

0.305<br />

1<br />

1.524<br />

5<br />

B<br />

mm<br />

in.<br />

15.951<br />

0.628<br />

79.756<br />

3.140<br />

A<br />

B<br />

Lubrication<br />

<strong>Timken</strong> is dedicated to using the highest quality components in<br />

everything we do. This is why we use premium industrial grease<br />

in spherical roller bearing solid-block housed units. The lithiumcomplex<br />

extreme-pressure grease combines the benefits of wide<br />

operating temperatures and broad compatibility. This grease offers<br />

excellent thermal stability through temperatures ranging from -34°<br />

C to 177° C (-30° F to 350° F). When dealing with temperatures<br />

above 149° C (300° F), consult your <strong>Timken</strong> engineer for optional<br />

grease recommendations. Application-specific lubrication<br />

options are also available ranging from <strong>Timken</strong> Food Safe Grease<br />

(aluminum-complex) to <strong>Timken</strong> Mill grease (calcium-sulfonate)<br />

along with many others.<br />

Fig. C-18. Misalignment.<br />

European REACH Compliance<br />

<strong>Timken</strong> lubricants, greases and similar products sold in standalone<br />

containers or delivery systems are subject to the European<br />

REACH (Registration, Evaluation, Authorization and Restriction<br />

of CHemicals) directive. For import into the European Union,<br />

<strong>Timken</strong> can sell and provide only those lubricants and greases<br />

that are registered with ECHA (European CHemical Agency). For<br />

further information, please contact your <strong>Timken</strong> engineer.<br />

<strong>Timken</strong> ® HOUSED UNIT CATALOG C-33