DIRIS A40/A41<br />

Multifunction meters - PMD<br />

multi-measurement meter - dimensions 96 x 96 mm<br />

Accessories<br />

Current transformers<br />

(see page 106)<br />

IP65 protection<br />

Panel mounting kit for a 144 x 96 mm cut-out<br />

trafo_024_a_2_cat<br />

trafo_077_b_2_cat<br />

diris_720_a_2_cat<br />

diris_718_b_1_cat<br />

Terminals<br />

DIRIS A40<br />

diris_569_a_1_x_cat<br />

V1 V2<br />

DIRIS A40<br />

V3<br />

VN<br />

A U X<br />

S1 S2 S1 S2 S1 S2<br />

I1 I2 I3<br />

S1 - S2: current inputs<br />

AUX: auxiliary power supplies U s<br />

V1- V2 - V3 - VN: voltage inputs<br />

DIRIS A41<br />

diris_570_a_1_x_cat<br />

V1 V2<br />

DIRIS A41<br />

V3<br />

VN<br />

A U X<br />

S1 S2 S1 S2 S1 S2 S1 S2<br />

I1 I2 I3 IN<br />

S1 - S2: current inputs<br />

AUX: auxiliary power supplies U s<br />

V1- V2 - V3 - VN: voltage inputs<br />

Communication module<br />

Pulse output module<br />

Analogue output module<br />

diris_571_a_1_x_cat<br />

diris_574_b_1_x_cat<br />

0V - +<br />

RS485<br />

1<br />

0n<br />

R = 120<br />

DIRIS A40 / A41<br />

RS485 link.<br />

R = 120 Ω: selectable internal resistance<br />

for RS485 end of line termination.<br />

2 inputs / 2 outputs module<br />

9 10 11 12<br />

OUT 1<br />

A-Cd<br />

OUT 2<br />

A-Cd<br />

13 14 15 16<br />

- + - +<br />

IN 1 IN 2<br />

DIRIS A40 / A41<br />

9 - 10 : relay output n°1.<br />

11 - 12 : relay output n°2.<br />

13 - 14 : opto input n°1.<br />

15 - 16 : opto input n°2.<br />

Ethernet Module<br />

diris_572_a_1_x_cat<br />

diris_683_a_1_x_cat<br />

1 2 3 4<br />

OUT 1 OUT 2<br />

DIRIS A40 / A41<br />

1 - 2 : pulse output n°1.<br />

3 - 4 : pulse output n°2.<br />

Memory module<br />

17 18<br />

+ -<br />

IN<br />

synchro<br />

DIRIS A40 / A41<br />

17 - 18 : synchronisation input.<br />

Ethernet module + RS485 MODBUS gateway<br />

diris_573_a_1_x_cat<br />

diris_753_a_1_gb_cat<br />

5 6 7 8<br />

+ - + -<br />

0/4-20 mA 0/4-20 mA<br />

OUT 1 OUT 2<br />

DIRIS A40 / A41<br />

5 - 6 : analogue output n°1.<br />

7 - 8 : analogue output n°2.<br />

Temperature module<br />

19 20 21 22 23 24 25 26<br />

sensor 1 sensor 2<br />

27 28 29 30<br />

sensor 3<br />

DIRIS A40/A41<br />

Sensor 1 Sensor 2<br />

19 : red 23 : red<br />

20 : red 24 : red<br />

21 : white 25 : white<br />

22 : white 26 : white<br />

Sensor 3<br />

27 : red<br />

28 : red<br />

29 : white<br />

30 : white<br />

diris_752_a_1_x_cat<br />

10 BASE T<br />

100 BASE T<br />

RJ45<br />

DIRIS A40/A41<br />

diris_751_c_1_gb_cat<br />

10 BASE T<br />

100 BASE T<br />

RJ45<br />

DIRIS A40/A41<br />

0 V - +<br />

RS485<br />

gateway<br />

1<br />

0n<br />

R = 120Ω<br />

88 Catalogue 2017