Catalog Schneider Airsystems 2017
Descoperiti gama completa solutii pentru aerul comprimat. Compresoare profesionale mobile cu piston | Compresoare profesionale stationare cu piston | Compresoare industriale cu surub | Solutii pentru tratarea aerului comprimat | Sisteme de conectare pentru aerul comprimat | Scule de mana pneumatice
Descoperiti gama completa solutii pentru aerul comprimat. Compresoare profesionale mobile cu piston | Compresoare profesionale stationare cu piston | Compresoare industriale cu surub | Solutii pentru tratarea aerului comprimat | Sisteme de conectare pentru aerul comprimat | Scule de mana pneumatice
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Stationary screw compressors<br />
¾ System ready for operation, with integral cold dryer and vessel<br />
mounting<br />
¾ Dry compressed air for perfect working results<br />
¾ Easy-to-understand electronic control system enables easy<br />
handling and maximum operating comfort<br />
¾ Less space required thanks to compact dimensions<br />
¾ Time and cost savings during maintenance work with easily<br />
accessibly maintenance components<br />
¾ Low noise level with soundproof housing<br />
¾ Simple assembly of outlet channel through exhaust air guide<br />
directed upwards<br />
¾ Integrated control of rotation direction prevents expensive<br />
damage during commissioning and operation<br />
Durable, V-belt driven compressor blocks<br />
Electronic control system with control of rotation direction,<br />
operating hours indicator, service messages, etc.<br />
With integral cold dryer<br />
15-year rust guarantee on the vessel with inner coating<br />
With rubber dampers for extra stability<br />
Easily accessible condensate drain cock<br />
P<br />
P<br />
P<br />
P<br />
P<br />
P<br />
AirMaster on vessel with cold dryer<br />
1 | Compressed air generation<br />
Model<br />
Art. no.<br />
Pressure<br />
(bar)<br />
Flow rate<br />
(l/min) 2)<br />
Voltage<br />
(V)<br />
Drive<br />
power<br />
(kW)<br />
Tank vol.<br />
(l)<br />
1)<br />
LpA1 sound pressure level in accordance with DIN EN ISO 2151 using EN ISO 3744 2) Max. flow volume at working pressure in accordance with ISO 1217 (working pressure = indicated pressure - 1 bar)<br />
Weight<br />
(kg)<br />
Noise<br />
(dB(A)) 1)<br />
Dimensions<br />
(WxDxH)<br />
AM K 4-10-180 XBDK H404107 10 530 400 4 2x90 262 62 1.270x800x1.570<br />
AM K 4-10-270 XBDK H404105 10 530 400 4 270 228 62 1.500x600x1.400<br />
AM K 5-10-180 XBDK H405107 10 700 400 5,5 2x90 275 66 1.270x800x1.570<br />
AM K 5-10-270 XBDK H405105 10 700 400 5,5 270 229 66 1.500x600x1.400<br />
AM K 7-8-180 XBDK H407087 8 1.140 400 7,5 2x90 300 67 1.270x800x1.730<br />
AM K 7-10-180 XBDK H407107 10 1.010 400 7,5 2x90 300 67 1.270x800x1.730<br />
AM K 7-8-270 XBDK H407085 8 1.140 400 7,5 270 267 67 1.500x600x1.560<br />
AM K 7-10-270 XBDK H407105 10 1.010 400 7,5 270 267 67 1.500x600x1.560<br />
AM K 7-13-270 XBDK H407135 13 810 400 7,5 270 267 67 1.500x600x1.560<br />
AM K 11-8-500 XBDK H411083 8 1.700 400 11 500 440 64 1.960x740x1.725<br />
AM K 11-10-500 XBDK H411103 10 1.500 400 11 500 440 64 1.960x740x1.725<br />
AM K 11-13-500 XBDK H411133 13 1.150 400 11 500 426 64 1.960x740x1.725<br />
AM K 15-8-500 XBDK H415083 8 2.210 400 15 500 507 65 1.960x740x1.725<br />
AM K 15-10-500 XBDK H415103 10 2.000 400 15 500 499 65 1.960x740x1.725<br />
AM K 15-13-500 XBDK H415133 13 1.600 400 15 500 499 65 1.960x740x1.725<br />
AM K 18-8-500 XBDK H418083 8 3.000 400 18,5 500 539 67 1.960x740x1.725<br />
AM K 18-10-500 XBDK H418103 10 2.590 400 18,5 500 539 67 1.960x740x1.725<br />
AM K 18-13-500 XBDK H418133 13 2.110 400 18,5 500 539 67 1.960x740x1.725<br />
AM K 22-8-500 XBDK H422083 8 3.350 400 22 500 539 75 1.960x740x1.725<br />
AM K 22-10-500 XBDK H422103 10 3.050 400 22 500 539 75 1.960x740x1.725<br />
AM K 22-13-500 XBDK H422133 13 2.550 400 22 500 539 75 1.960x740x1.725<br />
Tip<br />
Screw compressors are often used incorrectly, e.g. for intermittent<br />
operation. Always ask a <strong>Schneider</strong> airsystems expert for<br />
on-site advice.<br />
67