TECHNICAL INFORMATION<br />

FRICTION LOSS CHARTS<br />

TABLE OF APPROXIMATE PRESSURE LOSSES FOR PIPE FITTINGS<br />

Steel Fitting Type ½" ¾" 1" 1¼" 1½" 2" 2½" 3" 4" 6" 8"<br />

Coupling 0.6 0.8 1 1.2 1.5 2 2.5 3 4 6 8<br />

Run of St. Tee 1 1 1.5 2 2 2.5 3 4 5 7 10<br />

Tee, Side Outlet 3 4.5 5 7 9 11 13 16 20 31 42<br />

Tee, Run Reduced ½" 1.5 2.5 3 4 5 6 7 8 12 16 20<br />

Elbow, 90° 1.5 2.5 3 4 5 6 7 8 12 16 20<br />

Elbow, 45° 0.75 1 1.3 1.7 2 2.5 3 3.5 5 7. 5 10<br />

Corporation Stop 9 9 9 9 9 9<br />

Curb Stop 6 6 7 7 8 8<br />

15<br />

32'<br />

14<br />

Plastic IPS or<br />

28'<br />

½" ¾" 1" 1¼" 1½" 2" 2½" 3" 4" 6"<br />

Copper Fitting Type<br />

13<br />

24'<br />

8"<br />

Coupling<br />

Run of St. Tee<br />

Tee, Side Outlet<br />

Tee, Run Reduced ½"<br />

Elbow, 90°<br />

Elbow, 34°<br />

1.5<br />

2.5<br />

7. 0<br />

3.5<br />

3.5<br />

1.5<br />

2.5<br />

3.0<br />

9.0<br />

4.5<br />

4.5<br />

2.0<br />

3.0<br />

4.0<br />

12.0<br />

6.0<br />

6.0<br />

3.0<br />

3.0<br />

5.0<br />

15.0<br />

8.0<br />

8.0<br />

3.5<br />

4.0 12<br />

6.0 11<br />

18.0 10<br />

9.09<br />

9.08<br />

4.07<br />

6.0<br />

8.0<br />

24.0<br />

11.0<br />

11.0<br />

5.0<br />

7. 0<br />

9.0<br />

30.0<br />

14.0<br />

14.0<br />

7. 0<br />

8.0<br />

11.0<br />

36.0<br />

17.0<br />

17.0<br />

8.0<br />

11.0<br />

15.0<br />

45.0<br />

24.0<br />

24.0<br />

10.0<br />

20' 18.0<br />

21.0<br />

16'<br />

70.0<br />

12' 34.0<br />

8' 34.0<br />

16.0<br />

24.0<br />

28.0<br />

90.0<br />

45.0<br />

45.0<br />

20.0<br />

4'<br />

6<br />

To use this chart, multiply the approximate “equivalent feet of pipe” value by the proper pipe pressure loss per 100 ft. rating, then<br />

divide by 100. The result is the fitting loss in PSI.<br />

Notes: <br />

5<br />

4<br />

It is recommended that the above chart be used only when the manufacturers 3 recommended pressure loss values are not available.<br />

3 4 5 6 7 8 9 10 11 12 13 14 15<br />

Gallons Per Minute<br />

Loss in PSI<br />

Factory Setting<br />

Check Height Setting in Feet<br />

ACCESSORY PRESSURE LOSS CHARTS<br />

TECHNICAL<br />

HCV PRESSURE LOSS CHART<br />

Loss in PSI<br />

15<br />

32'<br />

14<br />

28'<br />

13<br />

24'<br />

12<br />

20'<br />

11<br />

16'<br />

10<br />

9<br />

12'<br />

8<br />

8'<br />

7<br />

4'<br />

6<br />

5<br />

4<br />

3<br />

3 4 5 6 7 8 9 10 11 12 13 14 15<br />

Gallons Per Minute<br />

Factory Setting<br />

Check Height Setting in Feet<br />

SWING JOINT FRICTION LOSS<br />

Loss in PSI<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

0 1 2 3 4 5 6 7 8 9 10<br />

Flow in GPM<br />

166<br />

16<br />

14<br />

12