13.12.2012 Views

Quick-build roof panel, type D

Quick-build roof panel, type D

Quick-build roof panel, type D

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Quick</strong>-<strong>build</strong> <strong>roof</strong> <strong>panel</strong>, <strong>type</strong> D<br />

high quality thermal insulation system<br />

for save and quick <strong>roof</strong>ing<br />

3-point-sealing<br />

large spans due to optimal profildesign<br />

quick and simple assembly<br />

width of module 1000 mm<br />

sealing strip<br />

sealing strip<br />

sealing strip<br />

fixing screw<br />

insulation thicknesses 30, 40, 60, 80, 100, 120,140 mm


Romakowski GmbH & Co. KG<br />

<strong>Quick</strong>-<strong>build</strong> <strong>roof</strong>, <strong>type</strong> D<br />

with steel cladding on both sides<br />

333,3 333,3 333,3<br />

48<br />

sealing strip<br />

outer side<br />

42<br />

Cladding layers coil galvanized and coated sheet steel with organic coating<br />

materials, further cladding layers are available on request<br />

Surface finish profiled outside; standard, lightweight lining on the inside.<br />

Insulating core Rigid polyurethane foam, approx. 95 % closed cells,<br />

impact resistant and attached to the steel cladding over<br />

its whole area. Density approx. 40 kg/m³.<br />

Fire tests D B1 according to DIN 4102, flame retardant<br />

CH Class V.3. according to VKF Bern<br />

F Class Mi + M2 according to CSTB Paris<br />

A B1 according to ÖNORM B 3000, part 1<br />

EU EURO-Class B-s2, d0<br />

Approval Generally approved for use as <strong>roof</strong>ing / wall by the construction<br />

supervisory authorities and construction legislation. Approval no.<br />

Z-10.4-151 and Z-10.487 according to EN 14509 from DIBt, Berlin.<br />

Available lengths up to 24 m, depending on <strong>panel</strong> thickness<br />

DE 86644 Buttenwiesen, Postfach 53 E-Mail:<br />

DE 86647 Buttenwiesen, Herdweg 31 info@roma-daemmsysteme.de<br />

phone +49 - 82 74 9 99-0 Internet:<br />

telefax +49 - 82 74 9 99-150 www.roma-daemmsysteme.de<br />

D 010-10<br />

Production tolerances according approval, RAL GZ 617 and DIN 18202, part 5, table 3, line 7<br />

Quality monitoring EPAQ Düsseldorf, IMA Dresden, FIW Munich, MFPA Leipzig<br />

Sound insulation approx. 25 dB for all <strong>panel</strong> thicknesses<br />

Statics see our span tables<br />

Panel <strong>type</strong> D072 D082 D102 D122 D142 D162 D182<br />

Panel thickness d (mm) 72 82 102 122 142 162 182<br />

Cladding layer thickness<br />

outside<br />

inside<br />

(mm)<br />

(mm)<br />

0,6<br />

0,5<br />

0,6<br />

0,5<br />

Panel wight (kg/m²) 11,5 11,9 12,7 13,5 14,3 15,1 15,9<br />

Average U-value<br />

incl. supplement U<br />

0,6<br />

0,5<br />

0,6<br />

0,5<br />

0,6<br />

0,5<br />

0,6<br />

0,5<br />

date:<br />

06/12<br />

0,6<br />

0,5<br />

(W/m 2•K) 0,584 0,462 0,325 0,251 0,204 0,172 0,149<br />

U-value acc. to EN 13165 U (W/m 2•K) 0,601 0,480 0,339 0,262 0,213 0,180 0,158<br />

U-value acc. to EN 14509<br />

incl. joint<br />

inner side<br />

1000<br />

(module)<br />

sealing strip<br />

U (W/m 2•K) 0,754 0,573 0,388 0,293 0,235 0,197 0,169<br />

d<br />

ID 0612 ES