<strong>Quick</strong>-<strong>build</strong> <strong>roof</strong> <strong>panel</strong>, <strong>type</strong> D<br />
high quality thermal insulation system<br />
for save and quick <strong>roof</strong>ing<br />
3-point-sealing<br />
large spans due to optimal profildesign<br />
quick and simple assembly<br />
width of module 1000 mm<br />
sealing strip<br />
sealing strip<br />
sealing strip<br />
fixing screw<br />
insulation thicknesses 30, 40, 60, 80, 100, 120,140 mm
Romakowski GmbH & Co. KG<br />
<strong>Quick</strong>-<strong>build</strong> <strong>roof</strong>, <strong>type</strong> D<br />
with steel cladding on both sides<br />
333,3 333,3 333,3<br />
48<br />
sealing strip<br />
outer side<br />
42<br />
Cladding layers coil galvanized and coated sheet steel with organic coating<br />
materials, further cladding layers are available on request<br />
Surface finish profiled outside; standard, lightweight lining on the inside.<br />
Insulating core Rigid polyurethane foam, approx. 95 % closed cells,<br />
impact resistant and attached to the steel cladding over<br />
its whole area. Density approx. 40 kg/m³.<br />
Fire tests D B1 according to DIN 4102, flame retardant<br />
CH Class V.3. according to VKF Bern<br />
F Class Mi + M2 according to CSTB Paris<br />
A B1 according to ÖNORM B 3000, part 1<br />
EU EURO-Class B-s2, d0<br />
Approval Generally approved for use as <strong>roof</strong>ing / wall by the construction<br />
supervisory authorities and construction legislation. Approval no.<br />
Z-10.4-151 and Z-10.487 according to EN 14509 from DIBt, Berlin.<br />
Available lengths up to 24 m, depending on <strong>panel</strong> thickness<br />
DE 86644 Buttenwiesen, Postfach 53 E-Mail:<br />
DE 86647 Buttenwiesen, Herdweg 31 info@roma-daemmsysteme.de<br />
phone +49 - 82 74 9 99-0 Internet:<br />
telefax +49 - 82 74 9 99-150 www.roma-daemmsysteme.de<br />
D 010-10<br />
Production tolerances according approval, RAL GZ 617 and DIN 18202, part 5, table 3, line 7<br />
Quality monitoring EPAQ Düsseldorf, IMA Dresden, FIW Munich, MFPA Leipzig<br />
Sound insulation approx. 25 dB for all <strong>panel</strong> thicknesses<br />
Statics see our span tables<br />
Panel <strong>type</strong> D072 D082 D102 D122 D142 D162 D182<br />
Panel thickness d (mm) 72 82 102 122 142 162 182<br />
Cladding layer thickness<br />
outside<br />
inside<br />
(mm)<br />
(mm)<br />
0,6<br />
0,5<br />
0,6<br />
0,5<br />
Panel wight (kg/m²) 11,5 11,9 12,7 13,5 14,3 15,1 15,9<br />
Average U-value<br />
incl. supplement U<br />
0,6<br />
0,5<br />
0,6<br />
0,5<br />
0,6<br />
0,5<br />
0,6<br />
0,5<br />
date:<br />
06/12<br />
0,6<br />
0,5<br />
(W/m 2•K) 0,584 0,462 0,325 0,251 0,204 0,172 0,149<br />
U-value acc. to EN 13165 U (W/m 2•K) 0,601 0,480 0,339 0,262 0,213 0,180 0,158<br />
U-value acc. to EN 14509<br />
incl. joint<br />
inner side<br />
1000<br />
(module)<br />
sealing strip<br />
U (W/m 2•K) 0,754 0,573 0,388 0,293 0,235 0,197 0,169<br />
d<br />
ID 0612 ES