4.29.3” Tadle Warnings on Doors to Hszardous<br />
Area% Dwrs that lead to areas that might prove<br />
dangerous to a blind persm (for esample, dmrs to<br />
loading platforms, baler rwms stages, and the like)<br />
shall be made identifiable to the touch by a tsstured<br />
surface on the door frandlq knob, pull or other opsrat<br />
ing hardware Thk tsstured surface may be made by<br />
Imurling or roughing or by a nraterisl apphed to the<br />
contact surface Such textured surfaces sfrsll not be<br />
p+-ovidedfor emergency exit doors or any dwrs other<br />
than those to hszsrdous areas<br />
4.29.4 Tadk Wanrirrgs at Stairs (ReswvecO.<br />
4.29.5* Ta&fe Warnfrrgs at Hszdous Vehtcular<br />
Amsa. (Reservd.<br />
4.29.6* Tsctile Warnings at Refkctfng Pool%<br />
(Rss-ed.<br />
4.29.7” Standardisation. Tcxhn’ed surfaces for UIC<br />
tile tkmr warnings shall bs standard witM a building,<br />
facifii, skc, or comples of buildings<br />
4.30 Signage<br />
4.30.1 ● Gerremf.Signagersquimdto be accessible<br />
by 4. I Shall COfr’@y with 430.<br />
4.30.2” Chsractar Proportion. Lsttsrs and numbers<br />
on signs shall have a wictthtc-height rstio between 35<br />
and 1:1 and a stroks width.t&heigfrt ratio betwssn 1:5<br />
and 1:10.<br />
4.30.3” Color ConhsL Characters and symbols<br />
shall contrast with their background — either light<br />
characters on a dark background or dark characters<br />
on a Iiiht background<br />
4.30.4” Raff or Indented Ch&cters or ‘5P<br />
bok. Lettersand numberson signs shall be raissd or<br />
incised 1132 in (0.8 mm) minimum and shall be sarrs<br />
serif characters Raised characters or symbols shall be<br />
at least 5/8 in (16 mm) high but no higher tin 2 in<br />
(50 mm). Indented characters or symbols shall have a<br />
s&oke width of at Iesst 1/4 in (6 mm). Symbols or pie<br />
tographs on signs shall be raised or indentsd 1/32 in<br />
(0.8 mm) minimum.<br />
4.30.5 symbols of Accaasiblity. Accessible<br />
faciliies rsquirsd to bs identified bg 4.1, shall use ths<br />
international symbol of accsssibilii. The symbol shall<br />
be displaysd as shown in Fig. 43.<br />
4.30.6 Mounting Locstfon and Hefghi Interior<br />
sgnsge shafl bs locsted slorrgsi& the door on ~e<br />
latch side and shall be mounted st a height of<br />
&tween54in and66in(1370m&16n@<br />
stow the ftihsd IlOor.<br />
4.31 Telephones.<br />
4.31.1 General. Fubfictekphorres required to bs<br />
aCCI?S.5ibfeby 4.1 Shd[[ COl@y Wfth 431.<br />
4.31.2 Clear Floor or Ground Space A cksr floor<br />
or ground space at least 30 in by 48 in (760 mm by<br />
1220 mm) that allows either a forward or parsllel<br />
(b)<br />
Displsy Conditions<br />
Fig. 43<br />
Intenrstlonaf Symbol of Acceaslblfw<br />
4.31 Telephonea<br />
apprcach by a person using a wireelctmk shall be pm<br />
tied at telephones (see Fig 44). The clam floor or<br />
ground space shafl comply wftfr 42.4. Bases<br />
enclosure%and fissd seats shell not impeds<br />
appmati to telephones by peopfe who use<br />
wlleelcfreirs<br />
4.31.3” Mounting Height. Ths highsstoperable<br />
partof the tslephone shall be tithh the reach ranges<br />
specifkd in 4.2.5 or 42.6.<br />
4.31.4 Protnsdfng Objects Telephones shsll<br />
Curnpfg Urltfr 4.4.<br />
4.31.5” Equipment for Heuirtg Impafmd Peopl+<br />
Telephones shsllbeequippe dwitharemivsrthsf<br />
genemtes anragn@c field inthesrea of therecaiwr<br />
cap. Volume conbuls shall be provided in amvdarma<br />
urtth 4.12.<br />
4.31.6 Conbula Telephones shrill hew pushbutton<br />
conbufs where sen.ice for such equiprrrarrt is awffsbk<br />
4.31.7 Tekephone Bock Tele@One book if w<br />
tied shall be Iocatad &r a po.sfdon thsf cornplfes<br />
W(I)I the reach rangss spacOled (n 425 arrd 42.6.<br />
.-<br />
41