05.04.2018 Views

Rivercove Residences EC Floorplans

Rivercove Residences, the latest and only EC launch in 2018, located at Sengkang Anchorvale Lane, District 19. Nestled in front of Punggol Reservoir, this much anticipated development offers exclusive riverfront living.

Rivercove Residences, the latest and only EC launch in 2018, located at Sengkang Anchorvale Lane, District 19. Nestled in front of Punggol Reservoir, this much anticipated development offers exclusive riverfront living.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Type C3-G (3-Br + Utility + Yard)<br />

Area:<br />

1076 ft 2 / 100 m 2<br />

Type C3-G<br />

KITCHEN<br />

PES<br />

LIVING<br />

BEDROOM<br />

3<br />

BEDROOM<br />

2<br />

MASTER<br />

BEDROOM<br />

Units:<br />

(inclusive of 12m 2 PES & 6m 2 AC Ledge)<br />

Blk 32, #01-22<br />

Blk 34, #01-26<br />

Blk 36, #01-31*<br />

Blk 38, #01-35*<br />

Blk 40, #01-38<br />

Type C3 (3-Br + Utility + Yard)<br />

Area:<br />

1076 ft 2 / 100 m 2<br />

(inclusive of 12m 2 Balcony & 6m 2 AC Ledge)<br />

BALCONY<br />

LIVING<br />

BEDROOM<br />

3<br />

BEDROOM<br />

2<br />

Units:<br />

Blk 30, #05-19* to #16-19*<br />

Blk 32, #02-22 to #16-22<br />

Blk 34, #02-26 to #16-26<br />

Blk 36, #02-31* to #16-31*<br />

Blk 38, #02-35* to #16-35*<br />

Blk 40, #02-38 to #16-38<br />

Type C3<br />

KITCHEN<br />

MASTER<br />

BEDROOM<br />

HALLWAY<br />

DB<br />

F<br />

WC<br />

Legend<br />

- Water Closet<br />

ENTRANCE<br />

FOYER<br />

DINING<br />

UTILITY<br />

WC<br />

YARD<br />

W<br />

BATH<br />

2<br />

AC LEDGE<br />

MASTER<br />

BATH<br />

AC LEDGE<br />

BLOCK<br />

38<br />

34<br />

33<br />

BLOCK<br />

35<br />

40 40<br />

36<br />

39<br />

37<br />

38<br />

BLOCK<br />

36 30<br />

29<br />

BLOCK<br />

31<br />

34 28<br />

32<br />

27<br />

25<br />

26<br />

BLOCK<br />

30 18<br />

17<br />

BLOCK<br />

19<br />

32 24<br />

20<br />

23<br />

21<br />

22<br />

W<br />

- Washer<br />

BLOCK<br />

26<br />

11 12<br />

BLOCK<br />

28<br />

13 14<br />

F<br />

DB<br />

*<br />

- Fridge<br />

- Distribution Board<br />

- Mirrored Unit<br />

0<br />

1<br />

3 5M<br />

ALL PLANS ARE SUBJ<strong>EC</strong>T TO CHANGES BY THE RELEVANT AUTHORITIES. MEASUREMENTS ARE<br />

APPROXIMATE ONLY AND SUBJ<strong>EC</strong>T TO FINAL SURVEY. INFORMATION ACCURATE AT THE POINT OF PRINTING.<br />

BP No. : A0712-03161-2016-BP01 DATED 25 JAN 2018<br />

N<br />

10<br />

BLOCK<br />

22<br />

07<br />

08<br />

06 05<br />

09 16<br />

BLOCK<br />

20<br />

01 02<br />

04 03<br />

15<br />

UPDATED AS OF 23 FEB 2018 (FINAL)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!