22<br />

<strong>Characteristic</strong> <strong>values</strong> <strong>and</strong> <strong>technical</strong> <strong>data</strong> <strong>of</strong> probes to measure the<br />

Note regarding probe designations:<br />

L: cable length for magnetic induction probes 5 m<br />

<strong>and</strong> for eddy current probes 3 m instead <strong>of</strong> 1.5 m.<br />

F: Measuring element protected against moist,<br />

aggressive media.<br />

T: Intermittent measurements on specimens with<br />

temperatures up to 100 ºC (212 ºF) possible.<br />

* Note: Probe capability (accuracy <strong>and</strong> precision)<br />

tested under controlled conditions.<br />

Description<br />

Order Number<br />

Measurement<br />

range<br />

ES1A (1)<br />

602-222<br />

0.5 - 108 % IACS<br />

0.3 - 63 MS/m<br />

ESW1A (1)<br />

602-389<br />

0.5 - 108 % IACS<br />

0.3 - 63 MS/m<br />

ES2<br />

602-223<br />

0.5 - 108 % IACS<br />

0.3 - 63 MS/m<br />

S1A (2)<br />

601-568<br />

0.5 - 108% IACS<br />

0.3 - 63 MS/m<br />

SW1A (2)<br />

601-615<br />

0.5 - 108% IACS<br />

0.3 - 63 MS/m<br />

S2 (3)<br />

601-569<br />

0.5 - 108% IACS<br />

0.3 - 63 MS/m<br />

ES4B (4)<br />

602-539<br />

ES40 (5)<br />

603-235<br />

0,5-108 % IACS<br />

0,3-63 MS/m<br />

Measurement<br />

accuracy*<br />

u s<br />

Measurement<br />

precision*<br />

s<br />

0.3 %<br />

<strong>of</strong> measured value<br />

0.01 % IACS or<br />

0.03 % <strong>of</strong> measured value<br />

0.3 %<br />

<strong>of</strong> measured value<br />

0.01 % IACS or<br />

0.03 % <strong>of</strong> measured value<br />

0.5 %<br />

<strong>of</strong> measured value<br />

0.0 1% IACS or<br />

0.05 % <strong>of</strong> measured value<br />

0.3 %<br />

<strong>of</strong> measured value<br />

0.01 % IACS or<br />

0.03 % <strong>of</strong> measured value<br />

0.3 %<br />

<strong>of</strong> measured value<br />

0.01 % IACS or<br />

0.03 % <strong>of</strong> measured value<br />

0.5 %<br />

<strong>of</strong> measured value<br />

0.01 % IACS or<br />

0.05 % <strong>of</strong> measured value<br />

0,3 %<br />

<strong>of</strong> measured value<br />

0,01 % IACS or<br />

0,03 % <strong>of</strong> measured value<br />

(1) : Probe can only be connected to FISCHERSCOPE ® MMS ® module SIGMASCOPE ® <strong>and</strong> module DUPLEX<br />

(2) : Probe can only be connected to SIGMASCOPE ® SMP1B<br />

(3) : Probe can only be connected to SIGMASCOPE ® SMP2<br />

(4) : Probe can only be connected to FISCHERSCOPE ® MMS ® EURO HF<br />

Probe<br />

Coating<br />

ø<br />

h<br />

Measurement point<br />

0 - 700 µm (28 mils)<br />

50 mm (200 mils)<br />

2 mm (80 mils)<br />

0 - 700 µm (28 mils)<br />

50 mm (200 mils)<br />

2 mm (80 mils)<br />

Lift-<strong>of</strong>f h<br />

Ø for 10% error<br />

min. Ø<br />

0 - 500 µm (20 mils)<br />

36 mm (1400 mils)<br />

2 mm (80 mils)<br />

0 - 700 µm (28 mils)<br />

50 mm (200 mils)<br />

2 mm (80 mils)<br />

0 - 700 µm (28 mils)<br />

50 mm (200 mils)<br />

2 mm (80 mils)<br />

0 - 500 µm (20 mils)<br />

36 mm (1400 mils)<br />

2 mm (80 mils)<br />

0 - 500 µm (20 mils)<br />

30 mm (1.2“)<br />

1 mm (40 mils)