Characteristic values and technical data of ... - vernier sales, inc.
Characteristic values and technical data of ... - vernier sales, inc.
Characteristic values and technical data of ... - vernier sales, inc.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
22<br />
<strong>Characteristic</strong> <strong>values</strong> <strong>and</strong> <strong>technical</strong> <strong>data</strong> <strong>of</strong> probes to measure the<br />
Note regarding probe designations:<br />
L: cable length for magnetic induction probes 5 m<br />
<strong>and</strong> for eddy current probes 3 m instead <strong>of</strong> 1.5 m.<br />
F: Measuring element protected against moist,<br />
aggressive media.<br />
T: Intermittent measurements on specimens with<br />
temperatures up to 100 ºC (212 ºF) possible.<br />
* Note: Probe capability (accuracy <strong>and</strong> precision)<br />
tested under controlled conditions.<br />
Description<br />
Order Number<br />
Measurement<br />
range<br />
ES1A (1)<br />
602-222<br />
0.5 - 108 % IACS<br />
0.3 - 63 MS/m<br />
ESW1A (1)<br />
602-389<br />
0.5 - 108 % IACS<br />
0.3 - 63 MS/m<br />
ES2<br />
602-223<br />
0.5 - 108 % IACS<br />
0.3 - 63 MS/m<br />
S1A (2)<br />
601-568<br />
0.5 - 108% IACS<br />
0.3 - 63 MS/m<br />
SW1A (2)<br />
601-615<br />
0.5 - 108% IACS<br />
0.3 - 63 MS/m<br />
S2 (3)<br />
601-569<br />
0.5 - 108% IACS<br />
0.3 - 63 MS/m<br />
ES4B (4)<br />
602-539<br />
ES40 (5)<br />
603-235<br />
0,5-108 % IACS<br />
0,3-63 MS/m<br />
Measurement<br />
accuracy*<br />
u s<br />
Measurement<br />
precision*<br />
s<br />
0.3 %<br />
<strong>of</strong> measured value<br />
0.01 % IACS or<br />
0.03 % <strong>of</strong> measured value<br />
0.3 %<br />
<strong>of</strong> measured value<br />
0.01 % IACS or<br />
0.03 % <strong>of</strong> measured value<br />
0.5 %<br />
<strong>of</strong> measured value<br />
0.0 1% IACS or<br />
0.05 % <strong>of</strong> measured value<br />
0.3 %<br />
<strong>of</strong> measured value<br />
0.01 % IACS or<br />
0.03 % <strong>of</strong> measured value<br />
0.3 %<br />
<strong>of</strong> measured value<br />
0.01 % IACS or<br />
0.03 % <strong>of</strong> measured value<br />
0.5 %<br />
<strong>of</strong> measured value<br />
0.01 % IACS or<br />
0.05 % <strong>of</strong> measured value<br />
0,3 %<br />
<strong>of</strong> measured value<br />
0,01 % IACS or<br />
0,03 % <strong>of</strong> measured value<br />
(1) : Probe can only be connected to FISCHERSCOPE ® MMS ® module SIGMASCOPE ® <strong>and</strong> module DUPLEX<br />
(2) : Probe can only be connected to SIGMASCOPE ® SMP1B<br />
(3) : Probe can only be connected to SIGMASCOPE ® SMP2<br />
(4) : Probe can only be connected to FISCHERSCOPE ® MMS ® EURO HF<br />
Probe<br />
Coating<br />
ø<br />
h<br />
Measurement point<br />
0 - 700 µm (28 mils)<br />
50 mm (200 mils)<br />
2 mm (80 mils)<br />
0 - 700 µm (28 mils)<br />
50 mm (200 mils)<br />
2 mm (80 mils)<br />
Lift-<strong>of</strong>f h<br />
Ø for 10% error<br />
min. Ø<br />
0 - 500 µm (20 mils)<br />
36 mm (1400 mils)<br />
2 mm (80 mils)<br />
0 - 700 µm (28 mils)<br />
50 mm (200 mils)<br />
2 mm (80 mils)<br />
0 - 700 µm (28 mils)<br />
50 mm (200 mils)<br />
2 mm (80 mils)<br />
0 - 500 µm (20 mils)<br />
36 mm (1400 mils)<br />
2 mm (80 mils)<br />
0 - 500 µm (20 mils)<br />
30 mm (1.2“)<br />
1 mm (40 mils)