14.12.2012 Views

notifier product catalogue contents

notifier product catalogue contents

notifier product catalogue contents

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Översättningstabell från gamla<br />

till nya artikelnummer finns i<br />

slutet av produktkatalogen.<br />

Produktkatalog<br />

2008<br />

SWEDEN - Release 1


Nordic<br />

NOTIFIER PRODUCT CATALOGUE<br />

CONTENTS<br />

CONVENTIONAL PANELS<br />

I - 1 NFS Series Conventional Panel<br />

I - 2 Expansion boards & Accessories<br />

CONVENTIONAL DEVICES<br />

II - 1 ECO1000 Series Conventional Detectors<br />

II - 2 ECO1000 Detector Bases<br />

II - 3 800 Series Conventional Detectors<br />

II - 4 800 Series Detector Bases<br />

II - 5 800 Series Commissioning Tools<br />

II - 6 Conventional Heat Detector<br />

II - 6 Detector Accessories<br />

II - 7 MCP Series Call Points<br />

II - 8 DH400 Series, Duct Detector<br />

II - 9 6500 Series Beam Detector<br />

II - 10 6500 Series Beam Detector Accessories<br />

ANALOGUE PANELS<br />

III - 2 ID60 1-Loop Analogue Panel<br />

III - 3 ID300 2-Loop Analogue Panel<br />

III - 3 ID3000 2-8 Loop Analogue Panel<br />

III - 4 Easy to order 4-8 loop panel<br />

III - 4 Power Supply & Accessories<br />

III - 5 Expansion Boards<br />

III - 6 Extension Chassis<br />

III - 7 Backbox & Enclosure Options<br />

III - 9 Flush Mounting Accessories<br />

III - 9 Repeaters BFT/LLT<br />

III - 10 Peripherals Devices<br />

III - 11 ID²Net Nettwork<br />

ANALOGUE DEVICES<br />

IV - 1 700 Series Analogue Detectors<br />

IV - 3 700 Series Detector Bases<br />

IV - 4 700 Series Detector Accessories<br />

IV - 5 M700 Series Addressable Modules<br />

IV - 6 M700 Series Addressable Module Accessories<br />

IV - 6 M700 Series Addressable Advanced Modules<br />

IV - 7 MCP700 Series Call Points<br />

IV - 8 Sagittarius Series Detection Wireless<br />

IV - 10 DH500 Series Duct Detectors<br />

IV - 11 LPB700 Seres Beam Detectors<br />

IV - 12 LPB700 Seres Beam Detector Accessories<br />

IV - 12 NAS Series Aspiration Detectors<br />

AUDIO & VISUAL DEVICES<br />

V - 1 Conventional Sounders<br />

V - 4 AVAX Addssable Sounders<br />

V - 5 AVAX Addssable Sounder Bases<br />

Release 2<br />

2008


Nordic<br />

NOTIFIER PRODUCT CATALOGUE<br />

CONTENTS<br />

MISCELLANEOUS<br />

INTRINSICALLY SAFE & EXPLOSION PROOF<br />

VI - 1 Conventional<br />

VI - 1 Analogue<br />

TEST EQUIPMENT<br />

VI - 2 Test Gas<br />

VI - 2 Test Kits<br />

VI - 3 Test Equipment<br />

POWER<br />

VI - 4 Batteries<br />

VI - 4 Powersupply<br />

ELECTRO MANGNET DOOR HOLDERS<br />

VI - 5 1300 Series<br />

VI - 8 ACCESSORIES<br />

DEKALER & SKYLT<br />

VII - 1<br />

WATERFLOW DETECTORS<br />

VIII - 1<br />

CROSSLIST<br />

Crosslist between old and new article numbers.<br />

Release 2<br />

2008


NFS SERIES<br />

The new NFS2-8 zone conventional fire alarm panels have been developed for both<br />

installers and end users with efficiency in mind, offering technically advanced range<br />

of facilities and functions while remaining easy to install, program and operate.<br />

A full range of conventional detectors, advanced conventional detectors, beam<br />

detectors, manual call points, duct mounting applications, audible and visible devices<br />

complement the NFS2-8 series.<br />

NFS SERIES<br />

ARTICLE NO. Panels<br />

002-477-329 TWO ZONE CONVENTIONAL FIRE ALARM PANEL<br />

2 configurable zones, 2 configurable outputs and 2<br />

configurable inputs<br />

Text insert labels included<br />

(SW, NO, DK, FIN)<br />

Dimensions: 356 x 318 x 96 mm (w x h x d)<br />

Weight: 2kg (no batteries), space for 12V-7Ah batteries<br />

IP rating: IP30<br />

Fire/Faul relay card included<br />

Possible options: 020-747 8 way relay board<br />

002-477-349 FOUR ZONE CONVENTIONAL FIRE ALARM PANEL<br />

4 configurable zones, 2 configurable outputs and 2<br />

configurable inputs<br />

Text insert labels included<br />

(SW, NO, DK, FIN)<br />

Dimensions: 356 x 318 x 96 mm (w x h x d)<br />

Weight: 2kg (no batteries), space for 12V-7Ah batteries<br />

IP rating: IP30<br />

Fire/Faul relay card included<br />

Possible options: 020-747 8 way relay board<br />

002-477-389 EIGHT ZONE CONVENTIONAL FIRE ALARM PANEL<br />

8 configurable zones, 2 configurable outputs and 2<br />

configurable inputs<br />

Text insert labels included<br />

(SW, NO, DK, FIN)<br />

Dimensions: 356 x 318 x 96 mm (w x h x d)<br />

Weight: 2kg (no batteries), space for 12V-7Ah batteries<br />

IP rating: IP30<br />

Fire/Faul relay card included<br />

Possible options: 020-747 8 way relay board<br />

Conv. Panels I - 1<br />

Release 2<br />

2008


ARTICLE NO. Accessories<br />

020-713 FS02 A/F FIRE AND FAULT RELAY EXPANSION CARD<br />

Adds fire and fault relay outputs to the NFS series panels<br />

020-747 8-WAY RELAY BOARD<br />

8 relay outputs which are configurable as N/O or N/C<br />

by jumper links (1A @ 30Vdc)<br />

Link setting allows 4 function presets to be configured for all 8 relays<br />

Max 2 8 relay PCB per panel<br />

020-743 EOL End of line NFS2-8 loop ( 10 pcs)<br />

020-745-008 Sparepart Kit NFS2-8<br />

Contains 8 pcs EOL (0,47µF), batterycables, hexagonal key,<br />

panel key and EOL for sounderoutput (4k7).<br />

ORS-3S CABINET FOR DOCUMENTATION<br />

Painted in black, fitted for A3 cover/perm.<br />

Opens with standard panel key.<br />

Dim: HxBxD = 464x353x86 m m<br />

020-710-003 SPARE TEXT INSERT LABELS<br />

English, Swedish, Danish, Norwegian, Finish<br />

334-067-006 SPARE RED KEY<br />

124-345-002 TWO ZONE REPLACEMENT PCB<br />

124-345-004 FOUR ZONE REPLACEMENT PCB<br />

124-345-008 EIGHT ZONE REPLACEMENT PCB<br />

Expansion Boards<br />

Conv. Panels I - 2<br />

Release 2<br />

2008


124-346 REPLACEMENT POWER SUPPLY BASEBOARD FOR NFS<br />

Conv. Panels I - 3<br />

Release 2<br />

2008


ECO1000 SERIES<br />

The ECO1000 is a range of conventional detectors, which have been produced using the latest in<br />

manufacturing technology and supplied with an array of advanced features, making them ‘better by<br />

design’.<br />

A laser-based hand held Remote Test Unit can be used in conjunction with the range of ECO1000<br />

detectors for alarm test purposes. With a range of several metres, the hand held test unit provides an<br />

effortless way of remotely alarm testing the range of ECO1000 detectors.<br />

The ECO1000 detectors also have an integral LED, which illuminates to provide a local alarm signal.<br />

This latches on, and remains illuminated until the detector is reset by a momentary power interruption.<br />

An optional remote LED annunciator may be used to repeat any alarm signal.<br />

A variety of detector bases can be used with the ECO1000 detectors, providing application flexibility<br />

and compatibility with a wide range of Fire Alarm Control Panels. All bases are fitted with a shorting<br />

spring to permit circuit testing prior to fitting the detector and have a tamper resistant feature, which<br />

when activated prevents removal of the detector without the use of a tool.<br />

ECO1000 SERIES<br />

ARTICLE NO. Detectors<br />

ECO1003 OPTICAL CONVENTIONAL DETECTOR<br />

Automatic drift compensation<br />

8 to 30VDC operation range (fire- and security solutions)<br />

-30 to +80°C operation temperature range<br />

ECO1005 RATE OF RISE THERMAL CONVENTIONAL DETECTOR<br />

Automatic drift compensation<br />

8 to 30VDC operation range (fire- and security solutions)<br />

-30 to +80°C operation temperature range<br />

ECO1005T FIXED THERMAL CONVENTIONAL DETECTOR (58°C)<br />

Automatic drift compensation<br />

8 to 30VDC operation range (fire- and security solutions)<br />

-30 to +80°C operation temperature range<br />

ECO1004T FIXED THERMAL CONVENTIONAL DETECTOR (78°C)<br />

Automatic drift compensation<br />

8 to 30VDC operation range (fire- and security solutions)<br />

-30 to +80°C operation temperature range<br />

ECO1002 OPTICAL/THERMAL DETECTOR<br />

Automatic drift compensation<br />

8 to 30VDC operation range (fire- and security solutions)<br />

-30 to +80°C operation temperature range<br />

Conv. Detectors Devices II - 1<br />

Release 2<br />

2008


ARTICLE NO. ECO1000 Detector Bases<br />

ECO1000B STANDARD MOUNTING BASE ECO 1000 SERIES<br />

ECO1000BR BASE WITH 470R RESISTOR FOR ECO 1000 SERIES<br />

ECO1000DB DEEP BASE FOR ECO 1000 SERIES<br />

ECO1000DBR DEEP BASE WITH 470R RESISTOR FOR ECO 1000 SERIES<br />

ECO1000BREL12L 12V RELAY BASE LATCHING<br />

The ECO1000BREL12L has been designed to provide interfacing<br />

between a ECO1000 detector and a 12V fire system or<br />

security system that require an external contact to activate<br />

an ancillary piece of equipment. The relay is controlled directly<br />

from the detector. Therefore, in an alarm condition both the detector<br />

and relay base will latch into alarm, and can only be reset by<br />

removing the supply voltage from the detector. The base can be<br />

used with 4 wire security systems that have a reset facility.<br />

ECO1000BREL12NL 12V RELAY BASE NON LATCHING<br />

The ECO1000BREL12NL has been designed to provide interfacing<br />

between a ECO1000 detector and 12V security control<br />

panels that do not provide a reset facility, as the relay base<br />

is self-resetting. Therefore, the relay base will automatically reset<br />

the ECO1000 detector when a fire alarm condition no longer exists.<br />

While the detector is in alarm the LED will be on, although it will<br />

flash when an alarm check is performed. This base is also ideal for<br />

control of any electrical apparatus such as air conditioning systems<br />

or apparatus utilising a 12V power supply instead of a control panel.<br />

ECO1000BREL24L 24V RELAY BASE LATCHING<br />

The ECO1000BREL24L has been designed to provide interfacing<br />

between a ECO1000 detector and 24V fire control<br />

panels or power supplies that require an external contact<br />

to activate an ancillary piece of equipment. The relay is controlled<br />

directly from the detector. Therefore, in an alarm condition both the<br />

detector and relay base will latch into alarm, and can only be reset<br />

by removing the supply voltage from the detector. A break off tab<br />

allows the base to be connected to a range of fire control panels.<br />

This tab should be broken when there is little current flow or no<br />

current limiting resistor such as when used as a stand-alone system<br />

powered by a 24V supply.<br />

S300RTU REMOTE TEST UNIT (batteries incl.)<br />

Pint laser at read detector diode for 1-2 seconds for testeing & to<br />

allow alarm test<br />

Conv. Detectors Devices II - 2<br />

Release 2<br />

2008


800 SERIES<br />

This range of detectors has been produced using the latest in manufacturing and design techniques,<br />

pushing out the boundaries of existing conventional detector technology. With it’s multitude of innovative<br />

features, the Series 800 is a detector which ‘acts conventionally, thinks intelligently’.<br />

Series 800 is the paradigm shift in conventional fire detector technology. This new range is the first to<br />

benefit from our latest innovation-remote test and configuration capability from the ground using a<br />

handheld test. Series 800 is feature rich, including sensitivity selection, addressability, status indication<br />

using a bi-color LED.<br />

Service and maintenance is also simplified because the contamination level of the serving chamber can<br />

be read maintenance dates can be written and an alarm test can be instigated - all through use of the<br />

same hand-held tool.<br />

800 SERIES<br />

ARTICLE NO. Detectors<br />

SD851E OPTICAL SMOKE DETECTOR<br />

Automatic drift compensation<br />

8 to 30VDC operation range (fire- and security solutions)<br />

-20 to +60°C operation temperature range<br />

Multi-function alarm - normal bi-colour LED indicator<br />

SD851TE OPTICAL THERMAL SMOKE DETECTOR (58°C)<br />

Automatic drift compensation<br />

8 to 30VDC operation range (fire- and security solutions)<br />

-20 to +60°C operation temperature range<br />

Multi-function alarm - normal bi-colour LED indicator<br />

FD851RE RATE OF RISE HEAT DETECTOR (+/- 10°C & 58°C)<br />

Automatic drift compensation<br />

8 to 30VDC operation range (fire- and security solutions)<br />

-20 to +60°C operation temperature range<br />

Multi-function alarm - normal bi-colour LED indicator<br />

FD851TE FIXED TEMPERATURE HEAT DETECTOR (58°C)<br />

Automatic drift compensation<br />

8 to 30VDC operation range (fire- and security solutions)<br />

-20 to +60°C operation temperature range<br />

Multi-function alarm - normal bi-colour LED indicator<br />

FD851HTE FIXED TEMPERATURE HEAT DETECTOR (78°C)<br />

Automatic drift compensation<br />

8 to 30VDC operation range (fire- and security solutions)<br />

-20 to +60°C operation temperature range<br />

Multi-function alarm - normal bi-colour LED indicator<br />

Conv. Detectors Devices II - 3<br />

Release 2<br />

2008


ARTICLE NO.<br />

B401 STANDARD TWO WIRE BASE<br />

B401DG 26 MM DEEP MOUNTING BASE<br />

B401R STANDARD BASE WITH 470R RESISTOR<br />

800 Series Detector Bases<br />

B312NL 12V NON-LATCHING RELAY BASE<br />

The B312NL has been designed to provide interfacing<br />

between a Series 800 detector and 12V security control<br />

panels that do not provide a reset facility, as the relay base<br />

is self-resetting. Therefore, the relay base will automatically reset<br />

the Series 800 detector when a fire alarm condition no longer exists.<br />

This base is also ideal for control of any electrical apparatus such as<br />

air co systems or apparatus utilising a 12V PSU instead of a control panel.<br />

B312RL 12V LATCHING RELAY BASE<br />

The B312RL has been designed to provide interfacing<br />

between a Series 800 detector and a 12V fire system or<br />

security system that require an external contact to activate<br />

an ancillary piece of equipment. The relay is controlled directly from the<br />

detector. Therefore, in an alarm condition both the detector and relay<br />

base will latch into alarm, and can only be reset by removing the supply<br />

voltage from the detector. The base can be used with 4 wire security<br />

systems that have a reset facility.<br />

B324RL 24V LATCHING RELAY BASE<br />

The B324RL has been designed to provide interfacing<br />

between a Series 800 detector and 24V fire control<br />

panels or power supplies that require an external contact<br />

to activate an ancillary piece of equipment. The relay is controlled directly<br />

from the detector. Therefore, in an alarm condition both the detector and<br />

relay base will latch into alarm, and can only be reset by removing the<br />

supply voltage from the detector. A break off tab allows the base to be<br />

connected to a range of fire control panels. This tab should be broken<br />

when there is little current flow or no current limiting resistor such as<br />

when used as a stand-alone system powered by a 24V supply.<br />

Conv. Detectors Devices II - 4<br />

Release 2<br />

2008


800 SERIES<br />

ARTICLE NO. Commissioning Tools<br />

S300ZDU ZONE DISPLAY UNIT<br />

The S300ZDU is the address display module used in<br />

conjunction with a zone of series 800 detectors.<br />

The unit is connected and powered directly from the<br />

conventional panel's zone wiring. When a series 800<br />

detector goes into alarm its address is automatically displayed<br />

on the S300ZDU.<br />

It is possible for the S300ZDU to display multiple alarms by scrolling<br />

addresses on the display. The first unit being uniquely identified.<br />

S300RPTU REMOTE PROGRAMMING TEST UNIT (batteries incl.)<br />

Programming of the following features (dist.: 2-3 cm):<br />

* read and write last maintenance date<br />

* read chamber contamin. level and th. element value<br />

* set detector status LED to blink or non blink<br />

* adjust sensitivity level and detector address & to allow an alarm test<br />

S300RTU REMOTE TEST UNIT (batteries incl.)<br />

Pint laser at read detector diode for 1-2 seconds for testeing & to<br />

allow alarm test<br />

S300SAT SATELLITE TEST UNIT<br />

Requires two 9V batteries (not included)<br />

Can only be used in combination with the S300RPTU<br />

unit, allowing to program the Series 800 detectors at<br />

distances up to 10m.<br />

S713AT ADAPTER TOOL 713<br />

Can be fitted at the end of the telescopic pole VP16, includes a<br />

magnet tester or can be used in combination with the System<br />

Sensor detector removal tools (XR2, XR5, S300DRT and S300SAT)<br />

Conv. Detectors Devices II - 5<br />

Release 2<br />

2008


ARTICLE NO. IP67<br />

SWM-1KL/57 Kapslet varmedetektor IP55<br />

Kapslet maksimaldetektor med fast alarmgrense >57°C<br />

SWM-1KL/80 Kapslet varmedetektor IP55<br />

Kapslet maksimaldetektor med fast alarmgrense >80°C<br />

SWM-1KL/100 Kapslet varmedetektor IP55<br />

Kapslet maksimaldetektor med fast alarmgrense >100°C<br />

SWM-1KL/150 Kapslet varmedetektor IP55<br />

Kapslet maksimaldetektor med fast alarmgrense >150°C<br />

ARTICLE NO.<br />

CONVENTIONAL HEAT DETECTOR<br />

WB1 WET BASE SHROUD<br />

Adapter base enclosure for humid environments.<br />

For use with standard bases B401/B501.<br />

Three mounting options are possible: surface mounting,<br />

cable mounting and pendant mounting.<br />

RMK400 RECESS MOUNTING KIT<br />

For suspended and drywall ceilings.<br />

For use with standard bases B401/B501.<br />

(Not compatible with ECO1000)<br />

SMK400 SURFACE MOUNTING KIT<br />

Provides for entry of surface wiring conduit.<br />

For use with standard bases B401/B501.<br />

(Not compatible with ECO1000)<br />

Conv. Detectors Devices II - 6<br />

DETECTOR ACCESSORIES<br />

Release 2<br />

2008


IRK-2E REMOTE INDICATOR LED<br />

Surface mounted with the supplied mounting box.<br />

09-DEKAL2 DEKAL "DOLD DETEKTOR"<br />

5 dekal / ark<br />

Conv. Detectors Devices II - 7<br />

Release 2<br />

2008


MCP SERIES - MANUAL CALL POINTS<br />

KAC Call Points - a range of indoor, outdoor and special environment <strong>product</strong>s suitable<br />

for all applications.<br />

All <strong>product</strong>s are available in a wide variety of colour and marking options.<br />

An extensive range of adaptor trays is available,allowing easy installation anywhere<br />

in the world.<br />

Further local territory approvals have been attained.<br />

MCP SERIES<br />

ARTICLE NO. Indoor (IP24)<br />

MCP1A-R470SG-01 MCP WITH BREAK GLASS ELEMENT<br />

with changeover contacts<br />

Including EN54 break glass and backbox<br />

Compatible with standard electric embedded box with screws<br />

WCP1A-R470SF-01 MCP SURFACE WITH FLEXIBLE ELEMENT IP67<br />

Normally open + monitoring resistor 470R<br />

Including surface mounting box and<br />

EN54 Flexible Operating Element<br />

KG1 X 10 SPARE EN54 BREAK GLASS FOR ALL KAC MCP<br />

PACK OF 10<br />

PS230 SPARE EN54 FLEXIBLE OP. ELEMENTS FOR MCP CALL POINTS<br />

PACK OF 10<br />

PS200 TRANSPARENT PROTECTIVE HINGED COVER<br />

SC070 PACK OF 10 SPARE TEST KEYS<br />

Conv. Detectors Devices II - 8<br />

Release 2<br />

2008


DH400 SERIES<br />

ARTICLE NO. Detectors<br />

DH400 DUCT DETECTOR HOUSING<br />

12/24VDC powered (operation range: 8,5 to 35VDC)<br />

This version contains no relays.<br />

Air velocity rating from 2,5 m/s to 20 m/s<br />

Connections for remote LED output, remote test station, remote annunciator<br />

The duct detector samples air passing through a duct and gives dependable<br />

performance for shutdown of fans, blowers or air co systems, so preventing<br />

the spread of toxic smoke and fire gases through the protected area.<br />

To be order separately: 02-SD851E Smoke Detector & 05-ST-xx Inlet Sampling Tube<br />

DH400ACDCE DUCT DETECTOR ASSEMBLY<br />

24VDC or 24VAC operation<br />

Air velocity rating from 2,5 m/s to 20 m/s<br />

Equipped with DPDT Auxiliary Relay Contacts<br />

Sounder output, remote LED output, remote test station, remote annunciator<br />

Can be used as a part of fire detection system or as a stand alone duct smoke<br />

detector which can be used to activate a sounder and shutdown fans, blowers<br />

or air co systems, so preventing the spread of toxic smoke and fire gases<br />

through the protected area.<br />

To be order separately: 2151E Smoke Detector & ST-xx Inlet Sampling Tube<br />

2151E OPTICAL CONVENTIONAL SMOKE DETECTOR<br />

For use with the duct detectors DH400E and DH400ACDCE.<br />

Note:<br />

The 2151 E detector is only available when it is ordered in combination with the<br />

DH 400 Series Duct Detectors<br />

ST1.5 INLET SAMPLING TUBE (LENGTH=457 MM)<br />

ST3.0 INLET SAMPLING TUBE (LENGTH=916 MM)<br />

Conv. Detectors Devices II - 9<br />

Release 2<br />

2008


6500 SERIES<br />

BEAM DETECTORS<br />

The 6500R is a conventional reflector- type linear optical beam smoke detector designed<br />

to operate as a component of a conventional fire alarm system. He operates primarily on<br />

the principle of light obscuration utilising an Infra-Red beam. Optical beam smoke<br />

detectors are particularly appropriate for protecting buildings with large open spaces such<br />

as warehouses, atriums etc.<br />

The 6500R detector is a combined transmitter/receiver unit that can be directly<br />

connected to a conventional detector circuit. The Infra-Red transmitter generates a beam<br />

of light towards a high efficiency reflector. The reflector returns the beam to the receiver<br />

where an analysis of the received signal is made.<br />

Alignment of the detector is simplified with the aid of the detector’s "gunsight" targeting<br />

device. Alignment of the detector with the reflector can then be “fine tuned” with the aid of<br />

a numerical signal strength indicator.<br />

The detector incorporates automatic drift compensation, whereby the detector will adjust<br />

its detection thresholds in line with any long term signal reduction of the beam caused by<br />

contamination of the optical surface.<br />

6500 SERIES<br />

ARTICLE NO. Detectors<br />

6500R 100M CONV. REFLECTIVE IR BEAM DETECTOR<br />

Infrared operation.<br />

Short range reflector (5M-75M) included.<br />

12VDC (security systems) or 24VDC powered<br />

Standby Current: 17mA, Alarm Current: 38,5mA<br />

IP Rating: IP54<br />

Detector Dimension: 254mm x 190mm x 84mm<br />

Included Reflector Dimension: 200mm x 230mm<br />

6500RS 100M CONV. REFLECTIVE IR BEAM DETECTOR<br />

WITH SELFTEST TOOL<br />

Same as 6500R with servo motored test tool<br />

Conv. Detectors Devices II - 10<br />

Release 2<br />

2008


6500 SERIES<br />

ARTICLE NO. Beam Detector Accessories<br />

BEAMLRK LONG-RANGE REFLECTOR (75M-100M)<br />

BEAMSMK SURFACE MOUNTING BOX<br />

Absolutly needed when using of the mounting Bracket kit<br />

BEAMMMK MOUNTING BRACKET - SWIVEL TYPE<br />

BEAM-HK HEATER KIT FOR 6500R<br />

To avoid condensation problems when used<br />

in non heated rooms.<br />

BEAM-HKR HEATER KIT FOR REFLECTOR<br />

To avoid condensation problems when used<br />

in non heated rooms.<br />

Conv. Detectors Devices II - 11<br />

Release 2<br />

2008


ID SERIES ANALOGUE FIRE PANELS<br />

ID SERES ANALOGUE FIRE PANEL<br />

ID 60 SERIES<br />

The ID60analogue addressable fire alarm control panel has been developed byNOTIFIER with efficiency<br />

for both installers and end users in mind.<br />

The ID60 panel will control op to 99 sensors on the single loop and a combination of 99 call points,<br />

monitor modules, control modules, conventional interface modules and loop powered sounders.<br />

With the ID60, we have thrown in a few little extra - such as hassle-free installation, easy programming<br />

with "Auto-learn", simple service and maintenance and Windows-based design and commissioning<br />

tools. Multilangual panel.<br />

Panel boxes are avilable in different sizes.<br />

Boxes coated to RAL7021 extra fine texture.<br />

ID 3000 SERIES<br />

ID3000 intelligent fire panel offer a technically sophisticated range of facilities and functions whilst<br />

remaining easy to install, program and operate.<br />

Modern styling and a variety of aesthetic options are sure to win over facility owners and architects. It<br />

has been 3rd party certified to the EN54 standard part 2 and 4.<br />

The ID3000 is designed in a modular fashion to allow for a wide range of applications.<br />

Remark:<br />

The last character of the reference for panel kit and basic equipement defines the language version of<br />

the system:<br />

group1: English, Spanish, Italian, Portuguese<br />

group 2: English, French, Dutch, German<br />

group 3: Swedish, Norwegian, Danish, Finnish<br />

group 4: Polish, Czech,Hungarian<br />

group 5: Russian, Cyrillic<br />

Analogue Panels III- 1<br />

Release 2<br />

2008


ARTICLE NO. PANELS<br />

002-456-003 ID60 SERIES PANEL (1 LOOP, 16 ZONES)<br />

Single loop intelligent fire panel with 16 zones.<br />

With Power supply 1,5A. Space for 12Ah batteries.<br />

Dimensions back box: 301(w) x 365(h) x 110(d) med mer<br />

020-599-009 INNBYGNINGSRAMME FOR ID50 / ID60<br />

020-553 ISOLATED RS485 MODULE KIT<br />

Includes PCB for isolated RS485 port for peripherals<br />

such as repeaters. Uses 1 panel COM port.<br />

400179 SKAP FOR ORIENTERINGSTEGNINGER<br />

Mål: 385 x 500 x 100 med mer<br />

020-638-003 RESERVEDELSKORT<br />

Bunnkort til ID60<br />

09-BFT2000 BFT, brannforsvarstablå<br />

Ved bestilling 09-BFT2000-ID60<br />

09-LLT2000 LLT, LARMLAGRINGSTABLÅ<br />

Ved bestilling 09-LLT2000-ID60<br />

Analogue Panels III- 2<br />

ID 60 SERIES<br />

S/No.<br />

124 -- 247<br />

Release 2<br />

2008


ARTICLE NO. PANELS<br />

002-303-003 FIXED 2 LOOP ANALOGUE FIRE PANEL KIT<br />

This kit includes:<br />

- Usermanual<br />

- Installationmanual<br />

- Nordic Firemannskey<br />

ARTICLE NO.<br />

Extensions possible: RS485 (020-479), RS232 (020-478),<br />

Peer to peer module (020-647)<br />

020-538-003 2-LOOP ANALOGUE FIRE PANEL<br />

Expandable to 8 loops by adding LIB ore ELIB loop cards.<br />

Includes the main chassis assembly, with hinged display,<br />

base PCB containing 2 loops and microprocessor PCB.<br />

240 x 64 pixels LCD display.<br />

Slide in labels included (language kit group 3).<br />

Includes:<br />

- 020-538-003 Basic Equipment kit<br />

- Usermanual<br />

- Installation manual<br />

- Nordic Firemannskey<br />

You must complete with following:<br />

- Backbox<br />

- Frontcover<br />

- Powersupply<br />

- Batteries<br />

Analogue Panels III- 3<br />

ID3000 SERIES<br />

Main Module<br />

Release 2<br />

2008


ARTICLE NO.<br />

ID3000 4-loop panel with standard backbox<br />

Folowing articles needs to bee ordered.<br />

1 x 020-538-003 Basic Equipment<br />

1 x 020-473-009 Backbox-U<br />

1 x 020-480-009 Frontcover<br />

1 x 020-481-009 Extended frontcover<br />

1 x 020-559-001 64 Zone Display<br />

1 x 020-648 Powersupply 3A<br />

1 x 020-588 Lopp card (LIB)<br />

ID3000 6-loop panel with standard backbox<br />

Folowing articles needs to bee ordered.<br />

1 x 020-538-003 Basic Equipment<br />

1 x 020-474-009 Backbox-UD<br />

1 x 020-480-009 Frontcover<br />

1 x 020-481-009 Extended frontcover<br />

1 x 020-559-001 64 Zone Display<br />

1 x 020-648 Powersupply 3A<br />

2 x 020-588 Lopp card (LIB)<br />

ID3000 8-loop panel with standard backbox<br />

Folowing articles needs to bee ordered.<br />

1 x 020-538-003 Basic Equipment<br />

1 x 020-476-009 Backbox-DUD<br />

1 x 020-480-009 Frontcover<br />

1 x 020-621-009 Extended frontcover<br />

1 x 020-612 256 Zone Display<br />

1 x 020-579 Powersupply 7A<br />

1 x 020-543 PSU DTP<br />

3 x 020-588 Lopp card (LIB)<br />

020-648 3A POWER SUPPLY UNIT KIT<br />

Switched mode power supply<br />

Guidance to order<br />

Power Supplies & Accessories<br />

020-579 7A UNIVERSAL POWER SUPPLY<br />

7A Power supply (020-579)<br />

7A Power supply can be mounted behind basic<br />

equipment if deep back box is used.<br />

(020-541-102 external PSU cabinet available)<br />

Needs PSU DTP/BOOSTER KIT (020-543)<br />

Analogue Panels III- 4<br />

Release 2<br />

2008


020-543 PSU DTP/BOOSTER KIT<br />

Includes complete PSU Interface unit assembly with<br />

interconnection cables and spare fuses. Mounts behind<br />

the basic equipment chassis. Essential for Universal<br />

Power Supply.<br />

020-548 PSU STATUS INDICATION KIT<br />

This optional unit includes complete assembly with interconnection<br />

cables. Mounts on the side of the 7A Power<br />

Supply Unit kit and gives status indication of the PSU.<br />

Use when ¨PSU-7A is mounted external the basic cabinet.<br />

020-541-009 78 Ah REMOTE BATTERY/CHARGER ENCLOSURE KIT<br />

Floor mounted only back box with extra depth for<br />

additional battery space. Powder coated in Honeywell light<br />

grey, extra fine texture. Includes power in connectors.<br />

Will hold batteries up to 78 Ah. Compatible with 7 A<br />

(020-579) PSU & compatible with status indication kit (020-548).<br />

PSU not included. Dimensions 680(w) x 510(h) x 240,5(d)<br />

ARTICLE NO.<br />

Expansion Boards<br />

020-588 ID3000 DUAL LOOP MODULE KIT<br />

Includes PCB for additional 2 loops, and plug in cable connector.<br />

020-549 ID3000 INTELLIGENT DUAL LOOP BOARD KIT (E-LIB CARD)<br />

Includes PCB for additional 2 loops, and plug in cable connector.<br />

Use this card when you have more than 512 detectors in total.<br />

020-568 RESERVEDELSKORT BUNNKORT TIL ID3000<br />

020-569 RESERVEDELSKORT PROSESSORKORT ID3000<br />

Analogue Panels III- 5<br />

TRICKLE TRICKLE CHARGE CHARGE<br />

LOW LOW BATTERY BATTERY<br />

MAIN MAIN PSU PSU FAILURE FAILURE<br />

BATTERY FAILURE<br />

CHARGER CHARGER FAILURE FAILURE<br />

MAINS MAINS ON ON<br />

124 -- 182<br />

S/No.<br />

OUT+ OUT- IN+ IN- OUT+ OUT- IN+ IN- LOOP B<br />

SK4<br />

LOOP A<br />

SK3<br />

SK2<br />

LOOP B<br />

SK2<br />

OUT+ OUT- IN+ IN- OUT+ OUT- IN+ IN- LOOP B SK1<br />

LOOP A SK3<br />

S/No.<br />

124 -- 292<br />

LOOP B SK1<br />

Release 2<br />

2008


ARTICLE NO.<br />

020-559-001 EXTENSION CHASSIS WITH 64 ZONE DISPLAY MODULE KIT<br />

Includes extension chassis with LED display board for<br />

zones 1 to 64. Will also accept integral printer (optional 020-471).<br />

Not nettwork campatible<br />

020-559-002 EXTENSION CHASSIS WITH 64 ZONE DISPLAY MODULE KIT<br />

Includes extension chassis with LED display board for<br />

zones 65 to 128. Will also accept integral printer (optional 020-471).<br />

Nettwork compatible<br />

020-612 ID3000 256 ZONE DISPLAY MODULE EXTENSION KIT<br />

(Requires double extension space & special cover 020-621-009)<br />

Nettwork compatible<br />

020-644-009 EXT. CHASSIS WITH PRINTER MODULE KIT<br />

Includes extension chassis with integral PRN2000 printer fitted.<br />

Uses 1 panel COM port.<br />

020-708-009 PRINTER MODULE KIT<br />

Includes thermal printer with power supply unit and roll<br />

of thermal paper. May be fitted to extension chassis kit<br />

020-559 or spare. Uses 1 panel COM port.<br />

09-SKRIVARE SCRIPTOS TERMOSKRIVER<br />

Extension Chassis<br />

09-PAPPER REPLACEMENT PAPER ROLL FOR PRINTER KIT<br />

Analogue Panels III- 6<br />

Release 2<br />

2008


ARTICLE NO.<br />

Backboxes & Enclosure Options<br />

020-480-009 MAIN COVER KIT<br />

Includes moulding, hinges for user interface door, push<br />

clip fasteners and hex fixing tool. Finished in Honeywell light<br />

grey. Moulding adds 21 mm to overall depth of<br />

back box.<br />

020-481-009 EXTENSION COVER KIT<br />

Includes moulding , hinges for user interface door, push<br />

clip fasteners and printer slot covering label. Finished in<br />

Honeywelllight grey. Moulding adds 21 mm to overall depth<br />

of back box.<br />

020-485-009 EXTENSION COVER BLANKING PLATE KIT<br />

Metal blanking plate to cover hole in 020-481-002 if<br />

no extension chassis is required. May be used for<br />

customisation such as mounting of plant switches.<br />

Finished in Honeywell light grey.<br />

020-621-009 FRONT FOR DOUBLE EXTENDED BACK BOX<br />

020-472-009 STANDARD BACK BOX CAB B1<br />

Basic back box kit coated in Honeywell light grey.<br />

Includes power in connectors. Will hold batteries up to<br />

12Ah . Suitable for use with single extension.<br />

Dimensions 500 (w) x 400 (h) x 122 (d)<br />

020-473-009 EXTENDED BACK BOX CAB C2<br />

Single "extended height" back box with extra depth<br />

for additional battery space, powder coated in Honeywell<br />

light grey. Includes power in connectors. Will hold<br />

batteries up to 27Ah. Suitable for use with single extension.<br />

Dimensions 500(w) x 620(h) x 122(d)<br />

Analogue Panels III- 7<br />

Release 2<br />

2008


020-474-009 EXTENDED DEEP BACK BOX CAB C2<br />

Single "extended height" back box with extra depth<br />

for additional battery space, powder coated in Honeywell<br />

light grey. Includes power in connectors. Will hold<br />

batteries up to 27Ah. Suitable for use with single extension.<br />

Dimensions 500(w) x 620(h) x 220(d)<br />

020-475-009 DOUBLE EXTENDED BACK BOX CAB D2<br />

Double "extended height" back box with extra depth for<br />

additional battery space, powder coated in Honeywell<br />

light grey. Includes power in connectors. Will<br />

hold batteries up to 27Ah with chassis fitted. Suitable<br />

for use with dual extension.<br />

Dimensions 500(w) x 840(h) x 122(d)<br />

020-476-009 DOUBLE EXTENDED DEEP BACK BOX CAB D2<br />

Double "extended height" back box with extra depth for<br />

additional battery space, powder coated in Honeywell<br />

light grey. Includes power in connectors. Will<br />

hold batteries up to 24Ah with chassis fitted. Suitable<br />

for use with dual extension.<br />

Dimensions 500(w) x 840(h) x 220(d)<br />

020-508-009 EXTENSION BACK BOX KIT<br />

Deep back box with extra depth for additional battery space.<br />

Powder coated to Honeywell white color. Includes<br />

power in connectors. Will hold batteries up to 38 Ah.<br />

Dimensions 500(w) x 220(h) x 122(d)<br />

(need cover 30-FRONT-U + blanking plate 30-020-485-009)<br />

020-509-009 EXTENSION DEEP BACK BOX KIT<br />

Deep back box with extra depth for additional battery space.<br />

Powder coated to Honeywell white color. Includes<br />

power in connectors. Will hold batteries up to 38 Ah.<br />

Dimensions 500(w) x 220(h) x 220(d)<br />

(need cover30-FRONT-U + blanking plate 30-020-485-009)<br />

Analogue Panels III- 8<br />

Release 2<br />

2008


ARTICLE NO.<br />

020-585 BEZEL STANDARD<br />

Semi-flush mount bezel for standard height back box.<br />

Finished in Honeywell light grey<br />

020-039-009 BEZEL EXTENDED<br />

Semi-flush mount bezel for standard height back box.<br />

Finished in Honeywell light grey<br />

020-040-009 BEZEL DOUBLE EXTENDED<br />

Semi-flush mount bezel for standard height back box.<br />

Finished in Honeywell light grey<br />

ARTICLE NO.<br />

400133 SKAP FOR ORIENTERINGSTEGNINGER<br />

09-BFT2000 BFT, BRANNFORSVARSTABLÅ<br />

09-LLT2000 LLT, LARMLAGRINGSTABLÅ<br />

020-478 ISOLATED RS232 MODULE KIT<br />

Includes PCB for isolated RS232 port for OEM interface,<br />

80 column printer etc. Uses 1 panel COM port.<br />

MA1049 INTERFACE TIL BFT/LLT<br />

CC-kort<br />

Analogue Panels III- 9<br />

Flush Mounting Accessories<br />

ID3000 Repeaters<br />

S/No.<br />

RTS<br />

Rx<br />

CTS<br />

Tx<br />

OV<br />

SIG<br />

124 - 248<br />

SK1 SK2<br />

Release 2<br />

2008


ARTICLE NO.<br />

Peripherals Devices<br />

020-479 ISOLATED RS485 MODULE KIT<br />

Includes PCB for isolated RS485 port for peripherals<br />

such as repeaters. Uses 1 panel COM port.<br />

020-573 MIMIC CONTROL PCA KIT<br />

Mimic control PCA Kit. Support up to 8 Mimic Drivers.<br />

Requires external 24Vdc Power source<br />

Requires minimum one 020-574<br />

Analogue Panels III- 10<br />

S/No.<br />

124 -- 247<br />

Release 2<br />

2008


ARTICLE NO.<br />

The IDNet peer to peer network is designed to be installed in the ID Fire Alarm Panel.<br />

The IDNet works without adding to the task of attached fire panels. In fact, since the<br />

panels are relieved of all networking responsibilities, they perform faster and become<br />

100% fully dedicated to advanced alarm detection and alarm processing.<br />

Each Network gateway module has a powerful on-board microprocessor responsible for<br />

network integrity.<br />

In event of an open or short circuit between nodes, The failed part is isolated and the rest<br />

of the network continues to function as normal.<br />

Designed to exceed EN54-13<br />

ID²NET - Peer to Peer ID3000 Network<br />

002-643 ID3000 PEER TO PEER NETWORK GATEWAY MODULE (P2P)<br />

For use with XLS NET. One module per XLS80e Module<br />

002-643 PCA DUAL PORT. Fibre optic interface card (ID2 NET)<br />

For use with 020-647.<br />

002-467-100 NETWORK GATEWAY UNIT (NGU)<br />

NF3000 Peer to Peer Network Gateway with enclosure, network<br />

card, DC/DC converter and space for 12Ah batteries.<br />

Analogue Panels III- 11<br />

Release 2<br />

2008


Analogue Detectors<br />

ARTICLE NO. 700 Series<br />

SDX751EM ANALOGUE OPTICAL SENSOR<br />

Twin LED's, insect resistant screen, removable cover for<br />

field cleaning, direct decade address 01-99 entry,<br />

LED output and device blink option. Order base separately.<br />

SDX751TEM OPTIPLEX - ANALOGUE OPT/THERM SENSOR<br />

Twin LED's, insect resistant screen, removable cover for<br />

field cleaning, direct decade address 01-99 entry,<br />

LED output and device blink option. Order base separately.<br />

FDX551EM ANALOGUE THERM SENSOR MICRO<br />

Alarms when temperature exceeds 58°C.<br />

Twin LED's, direct decade address 01-99 entry,<br />

LED output and device blink option. Order base separately.<br />

FDX551HTEM ANALOGUE THERM SENSOR - HIGH TEMP.<br />

Alarms when temperature exceeds 78°C.<br />

Twin LED's, direct decade address 01-99 entry,<br />

LED output and device blink option. Order base separately.<br />

FDX551REM ANALOGUE THERM SENSOR - RATE OF RISE<br />

Alarms when temperature exceeds 58°C or when the rate<br />

of increase of temperature exceeds 10°C/min.<br />

Twin LED's, direct decade address 01-99 entry,<br />

LED output and device blink option. Order base separately.<br />

FSL751E ANALOGUE VIEW SENSOR<br />

Twin LED's, insect resistant screen, removable cover for<br />

field cleaning, direct decade address 01-99 entry,<br />

LED output and device blink option. Order base separately.<br />

HPX751 HARSH - ANALOGUE OPTICAL SENSOR<br />

Twin LED's, twin filters, removable filter for field cleaning,<br />

direct decade address 01-99 entry, LED output and device<br />

blink option, requires 24VDC.<br />

1450737-008 base to be ordered separately.<br />

Intelligent Detectors Devices IV - 1<br />

Release 2<br />

2008


ARTICLE NO.<br />

4 TECHNOLOGIES ANALOGUE DETECTOR<br />

This detector is a 4 Technologies Analogue detector that has<br />

the intelligence of a human and the ability to interpret fire and false alarm<br />

phenomenon.<br />

This detecor is a true multi criteria detector that can smell, feel, and see<br />

its environment using 4 sensing elements.<br />

Main Features:<br />

•Flexible software settings for optimum performace in all applications<br />

•High sensitivity to fires in all environments<br />

•Best immunity to false alarm threats<br />

•High CO alarm for additional life safety<br />

•Thermal, IR and CO values used to enhance detection of both flaming<br />

& smoldering fire types<br />

•All sensors supervised and fire sensitivity automatically adjusted<br />

•Lifetime counter and memory for long term adjustment of CO sensor<br />

BOSEC approved EN54-7 & 5<br />

IRX751CTEM 4 TECHNOLOGIES ANALOGUE SENSOR<br />

Twin LED's, insect resistant screen, removable cover for field<br />

cleaning, direct decade address 01-99 entry, LED output and<br />

device blink option. Order base separately.<br />

Minimum software requierment<br />

ID300/ID3000 panel software: v 4.34<br />

Config Tool PC software: v 2.11<br />

Contact Notifier Technical Support for more information.<br />

Intelligent Detectors Devices IV - 2<br />

Release 2<br />

2008


Bases for Analogue Detectors<br />

ARTICLE NO. 700 Series<br />

B501 STANDARD MOUNTING BASE (DIAM: 103 MM)<br />

With shield terminal, SEMS screw connections<br />

and address identification label.<br />

PACKED PER 10<br />

B501DG DEEP MOUNTING BASE (26MM)<br />

SEMS screw connections and address identification label.<br />

PACKED PER 10<br />

B524IE MOUNTING BASE WITH ISOLATOR<br />

with remote annunciator output - must be placed after 20 devices<br />

B524HTR HEATED BASE<br />

Deep analogue sensor base with heater resistor.<br />

SEMS screw connections and address identification label.<br />

B524RTE MOUNTING BASE WITH RELAY<br />

Deep analogue sensor base with built in relay.<br />

SEMS screw connections and address identification label.<br />

B524FTXE EURO HARSH BASE<br />

Intelligent Detectors Devices IV - 3<br />

Release 2<br />

2008


Detector Accessories<br />

ARTICLE NO. 700 Series<br />

WB1 WET BASE SHROUD<br />

Adapter base enclosure for humid environments.<br />

For use with standard bases B401/B501.<br />

Three mounting options are possible: surface mounting,<br />

cable mounting and pendant mounting.<br />

RMK400 RECESS MOUNTING KIT<br />

For suspended and drywall ceilings.<br />

For use with standard bases B401/B501.<br />

(Not compatible with ECO1000)<br />

SMK400 SURFACE MOUNTING KIT<br />

Provides for entry of surface wiring conduit.<br />

For use with standard bases B401/B501.<br />

(Not compatible with ECO1000)<br />

IRK-2E REMOTE INDICATOR LED<br />

Surface mounted with the supplied mounting box.<br />

Led's will not blink in normal mode on addressable systems !<br />

09-DEKAL2 DEKAL "DOLD DETEKTOR"<br />

5 dekal / ark<br />

Intelligent Detectors Devices IV - 4<br />

Release 2<br />

2008


M700 SERIES<br />

ARTICLE NO. Addressable Modules<br />

The new family of input/output modules are available in single and multi-way models<br />

within the same mechanical package, reducing both the cost of installation and the<br />

mounting space required.<br />

Their unique mechanical design allows each module to be mounted in either a wall box,<br />

on a DIN rail or within any type of enclosure. Irrespective of the mounting method chosen,<br />

the address switch is both visible and accessible for selection.<br />

Each module has built-in short circuit protection for the communications loop; however, to<br />

increase application flexibility, the isolators can be selected/deselected on an individual<br />

module basis.<br />

To help engineers in the maintenance and fault-finding process, both the LEDs and the<br />

switches can be viewed without having to remove the cover of the surface mounting box.<br />

The LEDs, being multi-colour, provide diagnostic information regarding the status of each<br />

individual input/output.<br />

For ease of installation, testing and maintenance, the field wiring terminals are of plug-in<br />

design.<br />

M710 SINGLE SUPERVISED INPUT<br />

M720 DOUBLE SUPERVISED INPUT<br />

M701 SINGLE SUPERVISED OUTPUT<br />

M721 DOUBLE SUPERVISED INPUT + SINGLE RELAY OUTPUT<br />

M710-CZ CONVENTIONAL ZONE INPUT<br />

M701-240-KO 240VAC/5A RELAY OUTPUT<br />

Intelligent Detectors Devices IV - 5<br />

Release 2<br />

2008


M701-240-DIN 240VAC/5A RELAY OUTPUT (DIN RAIL MOUNTING)<br />

M700X SINGLE ISOLATOR MODULE<br />

ARTICLE NO.<br />

M200-SMB SURFACE MOUNT BOX<br />

M200-SMB KO SURFACE MOUNT BOX WITH KNOCKOUTS<br />

PMB200 STANDARD MOUNTING CLIP<br />

With 2 holes for fixing<br />

M200-DIN DIN-RAIL MOUNTING CLIP<br />

4-pack<br />

ARTICLE NO.<br />

Addressable Module Accessories<br />

Addressable Advanced Modules<br />

MMX-10M 10-ADRRESSABLE INPUT MONITOR MODULE CARD<br />

Needs to be fitted in a separate box or in the back box<br />

of the control panel.<br />

MCX-55 5 WAY ADDRESSABLE INPUT MONITOR &<br />

5 WAY ADDRESSABLE RELAY CONTROL CARD<br />

Complete with end of line resistors and relais (30VDC - 1A)<br />

individual input & output disable switches, plug in screw connections and<br />

on board LED's with the facility for external LED's. (unboxed)<br />

Intelligent Detectors Devices IV - 6<br />

Release 2<br />

2008


MMX102E ADDRESSABLE MICRO MONITOR MODULE<br />

Supervised monitoring of contact with LED output.<br />

002-439 MULTI-MOUNT ENCLOSURE (MME).<br />

Metal box in Notifier grey colour (RAL7021).<br />

Can hold two standard size modules or two 10 way I/O<br />

module MMX-10M, CMX-10RM, MULTI-MX or two mains<br />

relay modules.<br />

002-629 IDP-LPB1 LOOP BOOSTER BOXED<br />

Complete with PSU3A and space for up to 12Ah batteries<br />

The loop booster is used to add power on the loop when devices<br />

are in alarm.<br />

THIS DEVICE DOESN'T EXTEND LENGTH OF LOOP.<br />

Intelligent Detectors Devices IV - 7<br />

Release 2<br />

2008


MCP700 SERIES<br />

ARTICLE NO. Indoor (IP24) Call Points<br />

M700KAC MCP FLUSH WITH BREAK GLASS ELEMENT<br />

Including EN54 break glass and backbox<br />

Compatible with standard electric embeded box with screws<br />

M700KACI MCP FLUSH WITH BREAK GLASS ELEMENT<br />

Including EN54 Flexible Operating Element<br />

Compatible with standard electric embeded box with screws<br />

With isolator<br />

M700WCP-R-SF MCP SURFACE WITH FLEXIBLE ELEMENT<br />

Including surface mounting box &<br />

EN54 Flexible Operating Element<br />

IP67<br />

M700WCP-R-i-SF MCP SURFACE WITH FLEXIBLE ELEMENT & ISOLATOR<br />

Including surface mounting box &<br />

EN54 Flexible Operating Element<br />

& short circuit Isolator<br />

IP67<br />

PS230 PACK OF 10 SPARE EN54 FLEXIBLE OP. ELEMENTS<br />

FOR M700 CALL POINTS<br />

PS200 TRANSPARENT PROTECTIVE HINGED COVER<br />

SC070 PACK OF 10 SPARE TEST KEYS<br />

Intelligent Detectors Devices IV - 8<br />

Release 2<br />

2008


WIRELESS DETECTION<br />

ARTICLE NO. SAGITTARIUS Series<br />

SG100 ANALOGUE OPTICAL WIRELESS DETECTOR<br />

Mounting base included.<br />

Powered with 1 x 3V Lithium batterie CR123 A<br />

SG350 ANALOGUE THERMAL WIRELESS DETECTOR<br />

Mounting base included.<br />

Powered with 1 x 3V Lithium batteries CR123A<br />

SG200 ANALOGUE MULTICRITERIA WIRELESS DETECTOR<br />

Mounting base included.<br />

Powered with 1 x 3V Lithium batteries CR123A<br />

SGCP100 ANALOGUE MANUAL CALL POINT WIRELESS<br />

Back box and break glass included.<br />

Powered with 1 x 3V Lithium batteries CR123A<br />

SGRS100 ADDRESSABLE INNDOOR SOUNDER WIRELESS<br />

Powered with 2 x 3V Lithium batteries CR123A<br />

SG-IDP-RM1 RADIO INTERFACE MODULE<br />

Able to control till 32 devices<br />

Up to 200m coverage (free space)<br />

Loop powered<br />

Frequency: 868 Mhz (7 channels in 868 Mhz)<br />

SGMI100 ANALOGUE SINGLE INPUT MODULE WIRELESS<br />

Can be used for connecting and monitoring external devices<br />

or convetinal fire detection.<br />

Powered with 1 x 3V Lithium batteries CR123A<br />

Intelligent Detectors Devices IV - 9<br />

Release 2<br />

2008


SGMC100 ANALOGUE SINGLE OUTPUT MODULE WIRELESS<br />

Enables tyhe controll of external devices from the control panel<br />

via its integral relay.<br />

Powered with 1 x 3V Lithium batteries CR123A<br />

SGW2W SURVAY AND TEST KIT<br />

CR-123 SPARE PRIMARY BATTERY<br />

Compatible with all HyFire wireless devices<br />

CR 123 A (1.2Ah)<br />

CR-2032 SPARE SECONDARY BATTERY<br />

Compatible with all HyFire wireless devices<br />

CR 2032 A (0.24Ah)<br />

SGWE HyFire Wireless Expander Module<br />

Requiers external 24VDC power supply<br />

Intelligent Detectors Devices IV - 10<br />

Release 2<br />

2008


DH500 SERIES<br />

ARTICLE NO. ANALOGUE DUCT DETECTORS<br />

DH500 DUCT DETECTOR HOUSING<br />

Operation range: 15 to 32VDC<br />

This version contains no relays.<br />

Air velocity rating from 2,5 m/s to 20 m/s<br />

Connections for remote LED output, remote test station, remote annunciator<br />

The duct detector samples air passing through a duct and gives dependable<br />

performance for shutdown of fans, blowers or air co systems, so preventing<br />

the spread of toxic smoke and fire gases through the protected area.<br />

Optional: analogue detector, RTS-451, ST-xx<br />

ST1.5 INLET SAMPLING TUBE (LENGTH=457 MM)<br />

ST3.0 INLET SAMPLING TUBE (LENGTH=916 MM)<br />

Intelligent Detectors Devices IV - 11<br />

Release 2<br />

2008


LPB 700 SERIES<br />

ANALOGUE BEAM DETECTORS<br />

The TC847A1004 is an addressable analogue reflector- type linear optical beam smoke<br />

detector designed to operate as a component of an analogue Notifier fire system.<br />

He operates primarily on the principle of light obscuration utilising an Infra-Red beam.<br />

Optical beam smoke detectors are particularly appropriate for protecting buildings with<br />

large open spaces such as warehouses, atriums etc.<br />

The TC847A1004 detector is a loop powered combined transmitter/receiver unit that<br />

can be directly connected to an analogue loop circuit.<br />

The Infra-Red transmitter generates a beam of light towards a high efficiency reflector.<br />

The reflector returns the beam to the receiver where an analysis of the received signal is<br />

Alignment of the detector is simplified with the aid of the detector’s "gunsight" targeting<br />

device.<br />

Alignment of the detector with the reflector can then be “fine tuned” with the aid of a<br />

numerical signal strength indicator.<br />

The detector incorporates automatic drift compensation, whereby the detector will adjust<br />

its detection thresholds in line with any long term signal reduction of the beam caused by<br />

contamination of the optical surface.<br />

LPC, VdS & BOSEC Approved EN54-12:2002<br />

LPB 700 SERIES<br />

ARTICLE NO. Beam Detectors<br />

LPB-700 ADDR. REFLECTIVE IR BEAM DETECTOR<br />

LPCB & BOSEC approved<br />

Loop powered, direct decade address entry.<br />

Infrared operation.<br />

Included:<br />

Test facility<br />

Short range reflector (10M-75M) .<br />

LPB-700T ADDR. REFLECTIVE IR BEAM DETECTOR<br />

LPCB & BOSEC approved<br />

Loop powered, direct decade address entry.<br />

Infrared operation.<br />

Selftest funktion<br />

Included:<br />

Test facility<br />

Short range reflector (10M-75M) .<br />

Intelligent Detectors Devices IV - 12<br />

Release 2<br />

2008


ARTICLE NO.<br />

BEAMLRK LONG-RANGE REFLECTOR (75M-100M)<br />

BEAMSMK SURFACE MOUNTING BOX<br />

Absolutly needed when using of the mounting Bracket kit<br />

BEAMMMK MOUNTING BRACKET - SWIVEL TYPE<br />

BEAM-HK HEATER KIT FOR 6500R<br />

To avoid condensation problems when used<br />

in non heated rooms.<br />

BEAM-HKR HEATER KIT FOR REFLECTOR<br />

To avoid condensation problems when used<br />

in non heated rooms.<br />

Beam Detector Accessories<br />

NAS SERIES - NOTIFIER ASPIRATING SYSTEM<br />

The NAS Series has been designed to provide all the benefits of aspirating smoke<br />

detection, including very early warning when VIEW sensor is installed inside<br />

the NAS unit. This has been achieved through the combination of the highest<br />

approved VIEW detection technology and a powerful aspirator.<br />

NAS SERIES<br />

ARTICLE NO. Detectors<br />

NAS-2 NOTIFIER ASPIRATING SYSTEM (MAX 100M)<br />

Supply voltage 17-32VDC - Metal housing<br />

LCD display with 16 characters and 4 status LED's.<br />

Two B501 bases included. VIEW sensors optional<br />

Two Alarm & one Fault relays included<br />

Max. sampling pipe length 100m<br />

2 Sampling Air Inlets Ø 25 mm<br />

Dimension: 355 (h) x 245 (w) x 112 (d)<br />

Intelligent Detectors Devices IV - 13<br />

Release 2<br />

2008


ARTICLE NO. Sounders<br />

BLK FIREALARM BELL<br />

For indoor use.<br />

Power supply 24VDC<br />

Max 95 dB<br />

CONVENTIONAL AUDIO & VISUAL DEVICES<br />

KBLK FIRE ALARM BELL IP65<br />

For indoor/outdoor use.<br />

Power supply 24VDC, power consumption 25mA<br />

Max 100 dB<br />

EMA1224B4R STANDARD SOUNDER RED<br />

4 tones, including slow whoop - Max. 106dB<br />

12, 24VDC - 12mA<br />

Complete with base NBRL/NBSW<br />

EMA1224FR SIRENE RØD<br />

4 tones, including slow whoop - Max. 106dB<br />

12, 24VDC - 12mA<br />

Complete with base NBRL/NBSW<br />

EMA24FRSSR COMBINED FULL FEATURE SOUNDER STROBE - 24VDC<br />

Red sounder - red clip-on lens. Strobe = 0.6W. Max. 106dB.<br />

EMA24RS2A XENON STROBE RED - 2W - 24VDC<br />

Amber<br />

EMA24RS2R XENON STROBE RED - 5W - 24VDC<br />

Red<br />

EMA24RS5R XENON STROBE WHITE - 2W - 12VDC<br />

Red<br />

Audio Visual V - 1<br />

Release 2<br />

2008


SLENSA BERENTSFARGET LINSE TIL BLITSLYS<br />

SLENSR RØD LINSE TIL BLITSLYS<br />

SLENSB BLÅ LINSE TIL BLITSLYS<br />

ELPBR LOW PROFILE BASE RED - IP44<br />

Low profile unit standing 22m proud of the mounting surface.<br />

Rear and side cable access<br />

ESBRS SURFACE BASE WITH SEALING KIT RED - IP66<br />

Depth 35mm for easy installation<br />

20 mm knockout inputs<br />

Audio Visual V - 2<br />

Release 2<br />

2008


CONVENTIONAL AUDIO & VISUAL DEVICES<br />

ARTICLE NO. Base Sounders<br />

DBS1224BW STANDARD BASE SOUNDER WHITE (4 TONES).<br />

9 - 33VDC, Max. 96dB, 35mm deep<br />

DBS1224FW FULL FEATURE BASE SOUNDER WHITE (14 TONES).<br />

9 - 33VDC, Max. 96dB, 35mm deep<br />

NBSLID/W DBS WHITE FRONT LID-Pack of 10<br />

NBSLID/R DBS RED FRONT LID-Pack of 10<br />

BLS 270 SOUNDER<br />

Power supply 24VDC, power consumption 20mA<br />

Must be completed with VTR-216P<br />

07-INDI EXTERNAL INDICATOR<br />

For hidden detectors<br />

Must be completed with VTR-216P<br />

VTR-216P FRAME FOR BLS 270 and 07-INDI<br />

Wall frame 25mm deep.<br />

IRK-2E REMOTE INDICATOR LED<br />

Surface mounted with the supplied mounting box.<br />

09-DEKAL2 DEKAL "DOLD DETEKTOR"<br />

5 dekal / ark<br />

Audio Visual V - 3<br />

Release 2<br />

2008


ADDRESSABLE AUDIO & VISUAL DEVICES<br />

ARTICLE NO. Sounders<br />

AWS32/R-I ADDRESSABLE WALL MOUNT SOUNDER<br />

32 tones SLOW WHOOP & Isolator including<br />

3 volume setting selectable<br />

3,7 mA - 102 db<br />

Ø 115 X H 68 or 111 mm depending base<br />

IP 33 with LPBW & IP65 with WDBx<br />

AWSB32/R/R-I ADDRESSABLE WALL MOUNT SOUNDER & STROBE<br />

32 Tones, Red box & Lens, including Isolator<br />

3 volume setting selectable<br />

9,7 mA - 102 db<br />

Ø 115 X H 68 or 111 mm depending base<br />

IP 33 with LPBW & IP65 with WDBx<br />

AWB/R-I ADDRESSABLE WALL MOUNT STROBE RED<br />

Red Lens, including Isolator<br />

6 mA<br />

Ø 115 X H 39 or 82 mm depending base<br />

IP 33 with LPBW & IP65 with WDBx<br />

ABS32/W-I ADDR. DETECTOR BASE SOUNDER<br />

32 tones SLOW WHOOP & Isolator including<br />

3 volume setting selectable<br />

2,8 mA - 92 db<br />

Ø 112 X H 69,2 or 111 mm depending base<br />

IP 21<br />

ABSB32/W/C-I ADDR. DETECTOR BASE SOUNDER WITH STROBE<br />

32 tones SLOW WHOOP & Isolator including<br />

3 volume setting selectable<br />

2,8 mA - 92 db<br />

Ø 112 X H 69,2 or 111 mm depending base<br />

IP 21<br />

Audio Visual V - 4<br />

Release 2<br />

2008


ARTICLE NO. Bases<br />

LPBW LOW PROFIL BASE<br />

ADDRESSABLE AUDIO & VISUAL DEVICES<br />

DBSPD PACK OF 5 SHALLOW BASE<br />

Detector white<br />

SDBR DEEP PROFIL BASE RED<br />

LPBW included<br />

SDBD DEEP PROFIL BASE DETECTOR WHITE<br />

LPBW included<br />

SDBW DEEP PROFIL BASE BRIGHT WHITE<br />

LPBW included<br />

WDBR DEEP WATERPROOF BASE RED<br />

LPBW included<br />

Audio Visual V - 5<br />

Release 2<br />

2008


ARTICLE NO. Detectors<br />

CONVENTIONAL<br />

5451EIS INTRINSICALLY SAFE CONVENTIONAL HEAT DETECTOR<br />

EEx ia IIB T5 - IIB<br />

ATEX APPROVED<br />

Maximum 3 detectors per zone<br />

MTL5061 ZENER BARRIER FOR INTRINSICALLY SAFE DETECTORS<br />

To be used with IST200 and 5451EIS<br />

ANALOGUE<br />

INTRINSICALLY SAFE & EXPLOSION PROOF DEVICES<br />

IDX751 INTRINSICALLY SAFE OPTICAL LOW PROFILE DETECTOR<br />

To be used in conjunction with the IST200 interface module<br />

Rated for use in zone 0,1 and 2 areas, BASEEFA approved<br />

Eex IIB T5 for potential explosive atmospheres.<br />

!! NO REMOTE INDICATOR OPTION AVAILABLE!!<br />

LOOP<br />

ZONE<br />

IST200<br />

EXB9002<br />

5451EIS<br />

+ B401<br />

Y72221 ZENER BARRIER FOR INTRINSICALLY SAFE DETECTORS<br />

To be used with IST200 and IDX751<br />

IST200 INTERFACE MODULE FOR 5451EIS<br />

The IST200 module allows up to 17 IDX751 detectors<br />

on one module.<br />

MLT5061 GALVANIC ISOLATOR FOR INTRINSICALLY<br />

SAFE DETECTORS<br />

Miscellaneous and Accessories VI - 1<br />

05-IDX751<br />

5451EIS<br />

+ B401<br />

1 17<br />

Max. 17 Detectors<br />

5451EIS<br />

+ B401<br />

05-IDX751<br />

Release 2<br />

2008


CONVENTIONAL<br />

MPC3A-R000FF-01IS INTRINSICALLY SAFE MANUAL CALL POINT<br />

Flexible element included<br />

Changeover contact, EN54 Markings<br />

Use suitable Zener barriers. Certification : Ex II 1 G - EEx ia II T4<br />

WCP3A-R000SF-01IS WATERPROOF INTRINSICALLY SAFE MANUAL CALL POINT<br />

Flexible element included<br />

Changeover contact, EN54 Markings<br />

Use suitable Zener barriers. Certification : Ex II 1 G - EEx ia II T4<br />

MTL5061 GALVANIC ISOLATOR FOR INTRINSICALLY<br />

SAFE DETECTORS<br />

Manual Break Glass Fire Alarm Call Points for use with zener barrier<br />

in hazardous areas.<br />

ZONE<br />

MTL5061<br />

Miscellaneous and Accessories VI - 2<br />

MCP<br />

I.S.<br />

MCP<br />

I.S.<br />

MCP<br />

I.S.<br />

Maximum 10 mcp per zone<br />

Release 2<br />

2008


TEST EQUIPMENT<br />

ARTICLE NO. Test Gas Cans<br />

SOLOA3-001 SMOKE DETECTOR TESTER CAN 250ml NON FLAMMABLE<br />

PRICE PER CAN<br />

25D SMOKE DETECTOR TESTER CAN 150ml PRICE PER CASE<br />

(1 CASE CONTAINS 12 CANS)<br />

Min. Order quantity = 1 case<br />

AITA Rules for Air Freight: UN 1950 Class 2.1 No subsidiary Risk<br />

ARTICLE NO.<br />

Test Kits<br />

VTKIT-1 VERSATOOL ENCLOSED DELIVERY TEST KIT<br />

Contains: 1 x VP16 16ft Telescopic Pole<br />

1 x VT1 Versa Test Dispenser<br />

1 x VTB1 Equipment Tool Bag<br />

1 x VP4X Extension Pole<br />

VT1 VERSATEST TEST GAS DISPENSER<br />

Economic and easy for testing smoke detectors.<br />

Can hold 25E smoke detector tester cans<br />

For use with VP16 and VP4X Versa Pool TM<br />

VP16 VERSAPOOL TELESCOPIC TEST POLE SYSTEM<br />

Extendable reach till 6,1m (=4,9m + VP4X)<br />

For use with VT1 VersaTest TM<br />

Lightweight, non conductive reinforced fiberglass<br />

VP4X VERSAPOOL 4' EXTENSION POLE<br />

For use with VP16 Versa Pool TM<br />

Lightweight, non conductive reinforced fiberglass 1,2m<br />

Miscellaneous and Accessories VI - 3<br />

Release 2<br />

2008


ARTICLE NO.<br />

SOLO200-001 DETECTOR REMOVALTOOL TYPE S<br />

Detector removal tool which is compatible with all types<br />

of fire detectorsand can be fixed on the VP16 or VP4X poles.<br />

SOLO330-001 SMOKEDETECTOR TEST<br />

For 100/200/600/700 series detectors.<br />

To use in combination with S713AT and VP16 (or XP-4)<br />

SOLO 461-001 HEATDETECTORTEST TYPE S<br />

Heatdetectortester with rechargeable batties.<br />

Must be completed with pole SOLO100-001<br />

SOLO100-001 TELESCOPE POLE TYPE S<br />

Telescopepole 4,5 m<br />

MPS 67-110 MAGNET TEST POLE ALUMINIUM 67 - 110 CM<br />

MPS 135-240 MAGNET TEST POLE ALUMINIUM 135 - 240 CM<br />

MPS 157-400 MAGNET TEST POLE ALUMINIUM 157 - 400 CM<br />

40091 TEST SMOKESTICK<br />

Gray 10 pcs/pk<br />

SYSTEM SENSOR TEST EQUIPMENT<br />

40031 TEST SMOKE PURE-AX:3<br />

Gray, For analysis of airstreem in clean rooms. Duration 40s<br />

Not corrosive.<br />

40032 TEST SMOKE PURE-AX:3<br />

Gray, For analysis of airstreem in clean rooms. Duration 65s<br />

Not corrosive.<br />

Miscellaneous and Accessories VI - 4<br />

Release 2<br />

2008


ARTICLE NO.<br />

RB070AHB 7.2 Ah 12V SEALED LEAD ACID BATTERY<br />

Dimensions 151 x 65 x 94mm - VDS Approved (G103125)<br />

RB120AHB 12 Ah 12V SEALED LEAD ACID BATTERY<br />

Dimensions 151 x 98 x 94mm - VDS Approved (G103125)<br />

RB180AHB 17 Ah 12V SEALED LEAD ACID BATTERY<br />

Dimensions 181 x 76 x 167mm - VDS Approved (G103126)<br />

RB260AHB 27 Ah 12V SEALED LEAD ACID BATTERY<br />

Dimensions 166 x 175 x 125mm - VDS Approved (G104026)<br />

RB400AHB 38 Ah 12V SEALED LEAD ACID BATTERY<br />

Dimensions 197 x 165 x 170mm<br />

RB650AHB 65 Ah 12V SEALED LEAD ACID BATTERY<br />

Dimensions 350 x 166 x 174mm<br />

PS24-2,5A POWERSUPPLY WITH CHARGER 24VDC - 2,5A<br />

Can hold batteries up to 17Ah (2 batt. Of 12V - 17Ah).<br />

Dimension: 383(w) x 408(h) x 97(d) med mer<br />

Input Voltage 230V ac +/- 10%, 50/60Hz<br />

PS24-5 POWERSUPPLY WITH CHARGER 24VDC - 5A<br />

Can hold batteries up to 17Ah (2 batt. Of 12V - 17Ah).<br />

Dimension: 383(w) x 408(h) x 97(d) med mer<br />

Input Voltage 230V ac +/- 10%, 50/60Hz<br />

BB-24 BATTERY BOX<br />

Plass for 2 stk batterier 12V 7,2Ah<br />

Miscellaneous and Accessories VI - 5<br />

BATTERIES<br />

Release 2<br />

2008


1300 SERIES<br />

ARTICLE NO. Electro Magnetic Door Holders<br />

1335NEML ELECTRO MAGNETIC LOCK<br />

Equipped with cushioned counter plates<br />

With release button,Nickel plated steel body & base in ABS<br />

Connection to terminals - Unlock button<br />

24VDC/65mA - retaining strength 50Kg<br />

1345NEML ELECTRO MAGNETIC LOCK<br />

Equipped with cushioned counter plates<br />

With release button and protection diode against current<br />

spikes. Nickel plated steel body; base in ABS<br />

Connection to terminals - Unlock button<br />

24VDC/100mA - retaining strength 100Kg<br />

1350NEML ELECTRO MAGNETIC LOCK<br />

Equipped with cushioned counter plates<br />

Aluminium container - Nickel plated steel body<br />

Connection to terminals. Internal electronic circuit allows<br />

halving the retaining strength. Unlock button<br />

Protection diode against current spikes<br />

Release button on the container side,<br />

Dimensions 95x95x40mm<br />

24VDC/34-65mA - retaining strength 25-50 Kg<br />

1360NEML ELECTRO MAGNETIC LOCK<br />

Equipped with cushioned counter plates<br />

Aluminium container - Nickel plated steel body<br />

Connection to terminals. Internal electronic circuit allows halving<br />

the retaining strength - Protection diode against current spikes<br />

Release button on the container side,<br />

Dimensions 95x95x40mm<br />

24VDC/40-100mA - Retaining strength 50-100 Kg<br />

Miscellaneous and Accessories VI - 6<br />

Release 2<br />

2008


1380/15 D MAGNETIC DOOR RELEASE UNIT 100KG<br />

The fixing bracket allows installation on floor, ceiling and wall.<br />

Nickel plated steel coil; steel bracket; allodium support<br />

Equipped with cushioned counter-plates<br />

Wire terminals - release button - 15 cm bracket<br />

With protection diode against current spikes.<br />

24VDC/100mA-Retaining strength 100 Kg<br />

1380/30 D MAGNETIC DOOR RELEASE UNIT 100KG<br />

Same as item 1380/15 D but with a 30cm bracket.<br />

DSN 210P FIRE DOOR RELEASER, FLUSH MOUBTED<br />

Must be completed with VTR-216P<br />

K1008 FIRE DOOR RELEASER, WALL MOUNTED<br />

Miscellaneous and Accessories VI - 7<br />

Release 2<br />

2008


ARTICLE NO.<br />

STI6535 WEATHER STOPPER SURFACE MOUNTED<br />

WITHOUT SOUNDER<br />

STI 9602 LOW PROFILE, SURFACE MOUNTING<br />

108mm x 210mm diameter<br />

STI 9605 LOW PROFILE, SURFACE MOUNTING<br />

115mm x 175mm diameter<br />

STI 9610 HIGH PROFILE, SURFACE MOUNTING<br />

145mm x 210mm diameter<br />

STI 9707 SURFACE MOUNTED BEAM DETECTOR GUARD<br />

FOR 6500/ LPB700. H 280mm x W 244mm x D 140mm<br />

400129 COMBICABINET<br />

For mounting OR / BFT / Printer<br />

400157 FLUSHFRAME FOR COMBICABINET<br />

80.474.679 COVER/PERM A3<br />

For documentation and drwaings<br />

Miscellaneous and Accessories VI - 8<br />

ACCESSORIES<br />

Release 2<br />

2008


FKE 9009 TIMER<br />

Disabling of detectors<br />

09-MRE2402 RELÉKORT<br />

2 releer<br />

BSK5230 ILLUMINATED SIGN FOR DISABLING<br />

Sektion/Zone is Disabled<br />

RHM075 ELEVATOR KIT<br />

For Smokedetector<br />

Miscellaneous and Accessories VI - 9<br />

Release 2<br />

2008


ARTICLE NO.<br />

09-SKYLT1 SKYLT "BRANDLARM"<br />

Mått: 80 x 30mm<br />

09-SKYLT2 SKYLT "DOLD DETEKTOR"<br />

Mått: 80 x 30mm<br />

09-SKYLT3 SKYLT "UTRYMN. LARM/BRANDLARM"<br />

Dubbelsidig, Mått: 115 x 30mm<br />

09-SKYLT4 SKYLT FÖR UTRYMNINGSLARM<br />

Monteras vid LTK<br />

"Aktiverar utrymningslarm, OBS Rädningstjänsten måsta larmas"<br />

"Aktiverar Utrymningslarm, Larmar rädningtjänst"<br />

09-BS04131 SKYLT "UTRYMINGSLARM"<br />

Under text:<br />

Lämna omedelbart bygnaden när larmsygnal ljuder<br />

Mått: 160 x 50mm<br />

09-BS04132 SKYLT "UTRYMINGSLARM"<br />

Under text:<br />

Lämna omedelbart bygnaden när larmsygnal ljuder<br />

Mått: 240 x 75mm<br />

09-BD04531 DEKAL - BRANDLARM<br />

För siren (midten)<br />

09-DEKAL1 DEKAL "BRANDLARM"<br />

5 dekal / ark<br />

09-DEKAL2 DEKAL "DOLD DETEKTOR"<br />

5 dekal / ark<br />

Dekal VII - 10<br />

SKYLT / DEKAL<br />

Release 2<br />

2008


WATERFLOW DETECTORS<br />

NOTIFIER/SYSTEM SENSOR Retard and Non-Retard T-Tap Water flow Detectors,<br />

designed for primary signalling in residential and branch line signalling in larger systems,<br />

fit any tee that has a 1" NPT branch, including: 1", 1-1/4" and 1-1/2" NPT threaded<br />

ferrous and brass tees; 1", 1-1/4", 1-1/2" and 2" copper sweat tees; 1" CPVC tees; and 1-<br />

1/2" polybutylene tees.<br />

The design of these units makes them easy to install and simple to<br />

maintain. Both can be mounted in the vertical or horizontal position.<br />

Two conduit openings permit easy hook-up with local alarm system.<br />

Delay mechanism assembly (Model WFDT only) and switch assemblies are field<br />

replaceable.<br />

WATERFLOW DETECTORS<br />

ARTICLE NO. Waterflow Switches (UL Listed/FM Approved)<br />

WFD25 WATERFLOW DETECTOR SCHEDULE 10/40, 2 1/2"<br />

WFD30-2 WATERFLOW DETECTOR SCHEDULE 10/40, 3"<br />

WFD40 WATERFLOW DETECTOR SCHEDULE 10/40, 4"<br />

Waterflow Detector VIII - 1<br />

Release 2<br />

2008


Crosslist<br />

Crosslist<br />

This is the crosslist between old and new Notifier article numbers.<br />

From 02.07.2008 only the new articles are available.<br />

Old article no New article no Benämning Svensk<br />

002-439 002-439 Multikapsling (MME)<br />

002-450-003 002-450-003 IDR2-A BRANNMANNSPANEL FÖR ID60<br />

002-451-003 002-451-003 IDR2-P INFORMASJONSPANEL FÖR ID60<br />

002-452-003 002-452-003 IDR6-A BRANNMANNSPANEL FÖR ID3000<br />

002-629 002-629 IDP-LPB1 Loop booster<br />

020-417 020-417 EOL FOR ÖVERVAKNING<br />

020-548 020-548 PSU Status indikator kit<br />

020-573 020-573 MIMIC kontroll kitt<br />

020-600-009 020-600-009 INNB. RAM FÖR IDR INNFÄLLD<br />

020-696-003 020-696-003 ID60 FRONT TEXT KIT REGION 3<br />

020-710-003 020-710-003 FRONT TEXT KIT REGION 3<br />

020-747 020-747 KORT 8 INNGÅNGAR/UTGÅNGAR<br />

02-1151E 1151E RÖKDETEKTOR JON 1151E<br />

02-2151E 2151E RÖKDETEKTOR OPT<br />

02-2351E 2351E RÖKDETEKTOR OPTISK KONVENTIONELL<br />

02-2351TEM 2351TEM MULTIDETEKTOR OPTISK RÖK/VÄRME<br />

02-4351E 4351E VÄRMEDETEKTOR MAX 78°<br />

02-4351FE 4351FE VÄRMEDETETKTOR MAX 58°<br />

02-4451E 4451E VÄRMEDETEKTOR MAX (78°)<br />

02-5351E 5351E VÄRMEDETEKTOR MAX/DIFF (58°)<br />

02-5451E 5451E VÄRMEDETEKTOR DIFF (MAX 60°)<br />

02-B312NL B312NL RELÄSOCKEL 12V NL ÅTERSTÄLLANDE<br />

02-B312RL B312RL RELÄSOCKEL 12V NL LÅSANDE<br />

02-B324RL B324RL RELÄSOCKEL 12V RL LÅSANDE FUNKTION<br />

02-B401 B401 DETEKTORSOCKEL 800-SERIEN<br />

02-B401DG B401DG DETEKTORSOCKEL DJUP<br />

02-B401R B401R DETEKTORSOCKEL 470 OHMS MOTSTÅND<br />

02-B412NL B412NL RELÄSOCKEL 12V NL<br />

02-B412RL B412RL SOCKEL 12V LÅSANDE<br />

02-B424RL B424RL RELÄSOCKEL 12V/24V LÅSANDE<br />

02-ECO1000B ECO1000B DETEKTORSOCKEL 2-TRÅD ECO<br />

02-ECO1000BR ECO1000BR Sockel ECO1000 470R motstånd<br />

02-ECO1000BREL12L ECO1000BREL12L DETEKTORSOCKEL RELÄ 12V<br />

02-ECO1000BREL12NL ECO1000BREL12NL Detektor sockel relä 12V<br />

02-ECO1000BREL24L ECO1000BREL24L DETEKTORSOCKEL RELÄ 24V<br />

02-ECO1000DB ECO1000DB Sockel, djup, for ECO1000 detektorer<br />

02-ECO1000RTU ECO1000RTU LASERBASERAT TESTINSTRUMENT<br />

02-ECO1002A ECO1002 ECO RÖKDETEKTOR OPTISK/VÄRME<br />

02-ECO1003A ECO1003 ECO RÖKDETEKTOR OPTISK<br />

02-ECO1004TA ECO1004T ECO VÄRMEDETEKTOR MAX TEMP<br />

02-ECO1005A ECO1005 ECO VÄRMEDETEKTOR MAX TEMP<br />

02-ECO1005TA ECO1005T ECO VÄRMEDETEKTOR MAX TEMP<br />

02-FD851HTE FD851HTE VÄRMEDETEKTOR MAX (78°)<br />

02-FD851RE FD851RE VÄRMEDETEKTOR MAX/DIFF (58°)<br />

02-MCP1A MCP1A-R470SG-01 Larmknapp, konventionell, EN54<br />

02-S300RPTU S300RPTU TEST & PROGRAMMERINGS ENHET<br />

02-S300RTU S300RTU LASERBASERAT TEST 300/800 SERIEN<br />

02-S300SAT S300SAT SATELITTEST<br />

02-S300ZDU S300ZDU Detektor indikeringsmodul<br />

02-SC035 SC070 TESTNYCKEL FÖR KR1/SR 10-PACK<br />

02-SD851E SD851E RÖKDETEKTOR OPTISK<br />

02-SD851TE SD851TE MULTIDETECTOR OPTISK RÖK/VÄRME<br />

02-SWM-1KL/100 SWM-1KL/100 VÄRMEDETEKTOR KAPSLAD IP-55 100<br />

02-SWM-1KL/140 SWM-1KL/140 VÄRMEDETEKTOR KAPSLAD IP-55 140<br />

02-SWM-1KL/57 SWM-1KL/57 VÄRMEDETEKTOR KAPSLAD IP-55 57<br />

02-SWM-1KL/80 SWM-1KL/80 VÄRMEDETEKTOR KAPSLAD IP-55 80<br />

03-B501 B501 SOCKEL ANALOG<br />

Release 2<br />

2008


Crosslist<br />

Old article no New article no Benämning Svensk<br />

03-B501DG B501DG SOCKEL ANALOG DJUP<br />

03-B5241E B5241E ISOLATORSOCKEL<br />

03-B524FTXE B524FTXE SOCKEL TILL HARSH<br />

03-B524RTE B524RTE DETEKTORSOCKEL MED RELÄ ANALOG<br />

03-DIN200 M200-DIN MONT.CLIPS MODULER DINSKENA, 4-PACK<br />

03-FDX551EM FDX551EM VÄRMEDETEKTOR ANALOG MAX 58<br />

03-FDX551HTEM FDX551HTEM VÄRMEDETEKTOR ANALOG MAX 78<br />

03-FDX551REM FDX551REM VÄRMEDETEKTOR ANALOG MAX/DIFF<br />

03-FSL751E FSL751E VIEW DETEKTOR<br />

03-HPX751 HPX751 HARSH OPTISK DETEKTOR<br />

03-ID50 002-455-003 BRANDLARMCENTRAL ID50 ANALOG<br />

03-KG1x5 KG1 X 10 Glas till larmknapp, 10pk<br />

03-M700KAC M700KAC Larmtryckknapp EN54<br />

03-M700KACI M700KACI Larmknapp, analog, EN54, m/isol<br />

03-M700X M700X ISOLATORMODUL<br />

03-M701 M701 UTGÅNGSMODUL, I UTGÅNG (CMX)<br />

03-M701-240 M701-240 240V RELÄUTG-VÄGG INKL BOX (CMX)<br />

03-M701-240-DIN M701-240-DIN MODUL 240V RELÄUTG-DINMONT (CMX)<br />

03-M701-240-KO M701-240-KO 240V RELÄ UTGÅNGSMODUL, FÖR VÄGG<br />

03-M710 M710 INGÅNGMODUL, 1 INGÅNG (MMX)<br />

03-M720 M720 INGÅNGSMODUL, 2 INGÅNGAR (MMX)<br />

03-M721 M721 MODUL 2 INGÅNGAR, 1 UTGÅNG<br />

03-MCX-55 MCX-55 KOMBIMODUL 5 ING/5 RELÄUTG<br />

03-MMB MMB MONTERINGSBOX MULTI<br />

03-MMX101E MMX101E ADRESSMODUL MINI<br />

03-MMX102E MMX102E ADRESSMODUL MICRO<br />

03-MMX-10M MMX-10M ADRESSMODUL 10 ADRESSER<br />

03-MMX1E MMX1E ADRESSMODUL STANDARD<br />

03-MRM-1 MRM-1 KONTROLLMODUL MED RELÄUTG 230V 5A<br />

03-MRM-1/DIN MRM-1/DIN KONTROLLMODUL M RELÄUTG 230V 5A<br />

03-MULTI-MX MULTI-MX MULTIMODUL 16 IN/UT (MMX-CMX-ZMX)<br />

03-PMB200 M200-PMB MONTERINGSCLIPS FÖR CENTRAL, 4-PACK<br />

03-PS2 KORT 124-108 KRETSKORT PS2-CMX<br />

03-PS200 PS200 Plast skydd till larmknapp<br />

03-SDX751EM SDX751EM RÖKDETEKTOR ANALOG OPT<br />

03-SDX751EM-BK SDX751EM-BK RÖKDETEKTOR ANALOG OPT SVART<br />

03-SDX751EM-WH SDX751EM-WH ANALOG RÖKDETEKTOR OPT VIT<br />

03-SDX751TEM SDX751TEM OPTIPLEX MULTIDETEKTOR ANALOG<br />

03-SMB200 M200-SMB MONTERINGSBOX TILL M700 MODULER<br />

03-SMB200-KO M200-SMB KO MONTERINGSBOX M700 SERIEN<br />

03-ZMX-1E M710-CZ KONVENTIONELLT SEKTIONS INTERFACE<br />

05-2251EIS 2251EIS EX DETEKTOR OPT ANALOG<br />

05-5451EIS 5451EIS VÄRMEDETEKTOR DIFF EX-KLASS<br />

05-6500R 6500R Linjerökdetektor<br />

05-6500RS 6500RS Linjerökdetektor m. självtest<br />

05-BEAMMMK BEAMMMK Fästplåt för linjerökdetektor<br />

05-BEAMSMK BEAMSMK Monteringsbox<br />

05-DH400 DH400 KANALDETEKTOR OPTISK KONV<br />

05-DH500 DH500 KANALDETEKTOR ANALOG<br />

05-EXB9002 MTL5061 Galvanicisolator for intrinsically detectors<br />

05-F36-05-00 F36-05-00 UTBYTESFILTER TILL DH400<br />

05-IDX751 IDX751 EX-KLASSAD DETEKTOR OPT ANALOG<br />

05-IST200 IST200 INTERFACE MODUL IDX751/2251EIS<br />

05-LPB700 LPB-700 Linjerökdetektor<br />

05-LPB700T LPB-700T Linjerökdetektor m. självtest<br />

05-ST1.5 ST1.5 SAMPLINGSRÖR KANALDET 30-60CM<br />

05-ST3.0 ST3.0 SAMPLINGSRÖR KANALDET 60-240CM<br />

05-WFD25 WFD25 FLÖDESVAKT10/40, 2,5"<br />

05-WFD30-2 WFD30-2 FLÖDESVAKT 3" RÖR, 2"<br />

05-WFD40 WFD40 FLÖDESVAKT 10/40 4"<br />

05-Y72221 Y72221 ISOLATORMODUL IDX751/2251EIS<br />

06-ACK 12-12 RB120AHB 12 Ah 12V SEALED LEAD ACID BATTERY<br />

Release 2<br />

2008


Crosslist<br />

Old article no New article no Benämning Svensk<br />

06-ACK 12-18 RB180AHB 17 Ah 12V SEALED LEAD ACID BATTERY<br />

06-ACK 12-27 RB260AHB 24 Ah 12V SEALED LEAD ACID BATTERY<br />

06-ACK 12-38 RB400AHB 38 Ah 12V SEALED LEAD ACID BATTERY<br />

06-ACK 12-42 RB650AHB 65 Ah 12V SEALED LEAD ACID BATTERY<br />

06-ACK 12-7 RB070AHB 7.2 Ah 12V SEALED LEAD ACID BATTERY<br />

06-BB24 BB-24 BATTERIBOX<br />

06-PS24-2,5A PS24-2.5A STRÖMFÖRSÖRJNING<br />

06-PS24-5A PS24-5A STRÖMFÖRSÖRJNING<br />

07-BLK BLK BRANDLARMKLOCKA<br />

07-IRK-2E IRK-2E LED indikator för detektor<br />

07-KBLK KBLK BRANDLARMKLOCKA KAPSLAD<br />

07-LOKK1 NBSLID/W VITT LOCK TILL DET.SIRÉN NBS/ABS<br />

07-LOKK2 NBSLID/R RÖTT LOCK DET.SIRÉN NBS/ABS 10-pack<br />

07-NBLR ELPBR SOCKEL STANDARD RÖD<br />

07-NBLW ELPBW STANDARDSOCKEL VIT<br />

07-NBS14 DBS1224FW SOCKELSIRÉN KONV,14 TONER<br />

07-NBS4 DBS1224BW SOCKELSIRÉN KONV, 4 TONER<br />

07-NBSR ESBRS SOCKEL IP66 RÖD<br />

07-NS14R EMA1224FR SIRÉN 24V RÖD<br />

07-NS14W EMA1224FW SIRÉN 24V VIT<br />

07-NS4R EMA1224B4R STANDARDSIRÉN 24V RÖD<br />

07-NS4W EMA1224BW STANDARDSIRÉN 24V VIT<br />

07-NX2RA EMA24RS2A BLIXTLJUS 24V BÄRNSTEN<br />

07-NX2RR EMA24RS2R BLIXTLJUS 24V RÖD<br />

07-NX5RR EMA24RS5R BLIXTLJUS 24V 5J RÖD<br />

07-NXS14R EMA24FRSSR KOMBINATION SIRÉN /BLIXT 24V RÖD<br />

07-NXS14W EMA12FWSSA KOMBINATION SIRÉN/BLIXT VIT<br />

07-RAM VTR-216P MONTERINGSRAM<br />

07-SLENSA SLENSA LINS TILL BLIXTLJUS, BÄRNSTEN<br />

07-SLENSB SLENSB BLÅ LINS TILL BLIXLJUS<br />

07-SLENSC SLENSC Lins till blixtljus, ofärgad<br />

07-SLENSG SLENSG GRÖN LINS TILL BLIXTLJUS<br />

07-SLENSR SLENSR RÖD LINS TILL BLIXTLJUS<br />

07-SSLENSR SSLENSR RÖD LINS TILL KOMBISIRÉN NXS14R<br />

07-SUM01 BLS 270 SUMMER<br />

08-DSN210 DSN 210P DÖRRSTÄNGNINGSKNAPP<br />

08-K1008 K1008 STRÖMBRYTARE UTANPÅLIGGANDE<br />

08-K1008I K1008I STRÖMBRYTARE INFÄLLD<br />

08-MG711 1335NEML Dörrhållarmagnet 50 kg<br />

08-MG712 1345NEML Dörrhållarmagnet 100 kg<br />

08-WMAG-24-20 1350NEML Dörrhållarmagnet 25-50 kg<br />

08-WMAG-24-40 1360NEML Dörrhållarmagnet 50-100 kg<br />

08-WMAG-FWB-150 1380/15 D Dörrhållarmagnet 100 kg 15cm bracket<br />

08-WMAG-WB-TELE 1380/30 D Dörrhållarmagnet 100 kg 30cm bracket<br />

09-212 13 DTB-212P/13-24 diodtablå 13-24 2x12<br />

09-2121-12 DTB-212P/1-12 diodtablå 1-12 d2x12<br />

09-216 P VTR-216P VÄGGRAM<br />

09-25D 25D TESTGAS BE 150 ML<br />

09-A100 SOLOA3-001 TESTGAS TYP S 250ML<br />

09-ADAPTER Adapter ADAPTER TILL SKRIVARE FÖR 220V<br />

09-BD04531 BD04531 DEKAL "BRANDLARM" FÖR SIRÉN<br />

09-BFT2000 09-BFT2000 BRANDFÖRSVARSTABLÅ<br />

09-BS04011+021 BS04011+021 SKYLT DUBBELSIDIG<br />

09-BS04131 BS04131 SKYLT UTR.LARM 160x50mm<br />

09-BS04132 BS04132 SKYLT UTRYMNINGSLARM 240x75mm<br />

09-BSK5230 BSK5230 LJUSSKYLT SEKTION FRÅNKOPPLAD<br />

09-CN-5 CN-5 KLAMMER TILL VÄRMEKABEL<br />

09-DEKAL1 09-DEKAL1 DEKAL BRANDLARM 5/ARK<br />

09-DEKAL2 09-DEKAL2 DEKAL "DOLD DETEKTOR" 5/ARK<br />

09-DEKAL3 09-DEKAL3 DEKAL SILVER TILL KLOCKA<br />

09-E1 09-E1 ETIKETT "ANLÄGGNINGSSKÖTARE"<br />

09-E2 09-E2 ETIKETT "CE" MÄRKE<br />

Release 2<br />

2008


Crosslist<br />

Old article no New article no Benämning Svensk<br />

09-E3 09-E3 ETIKETT "MANÖVERINSTRUKTION"<br />

09-E4 09-E4 ETIKETT "VARNING"-FÖR JON DETEK"<br />

09-E5 09-E5 ETIKETT "ORIENTERINGSRITNINGAR"<br />

09-E6 09-E6 ETIKETT "SERVICERITNINGAR" BR.LARM<br />

09-EC180 STI 9602 Steel web stoppers 108x210mm for Detector<br />

09-EC180DJ STI 9610 Steel web stoppers 145x210mm for Detector<br />

09-FI400 56-FI400 FILTER TILL RÖKDETEKTOR<br />

09-FKE9009 FKE 9009 TIMER FRÅNKOPPLING DETEKTORER<br />

09-fso a3 FSO-3 etikett OR ritn A3<br />

09-FSO-4 FSO-4 framsida or-ritning<br />

09-FSS-4 FSS-4 framsida sr-ritningar<br />

09-HDC-105 HDC-105 VÄRMEKABEL 105°, PRIS PER METER<br />

09-INSUGSFILTER FILTRO FILTER NAS<br />

09-INTERFACE MA1049 INTERFACE FÖR BFT/LLT/PRINTER/EXT<br />

09-KK-1 KK-1 KLAMMER TILL VÄRMEKABEL<br />

09-KOMBI 400129 KOMBISKÅP OR-BFT-PRINTER<br />

09-KOMBIRAM 400157 INBYGGNADSFLÄNS KOMBISKÅP<br />

09-LLT2000 09-LLT2000 LARMLAGRINGSTABLÅ<br />

09-MPS 135 MPS 135-240 MAGNETPROVSTÅNG ALU 135-240CM<br />

09-MPS 157 MPS 157-400 MAGNETPROVSTÅNG ALU 157-400CM<br />

09-MPS 67 MPS 67-110 MAGNETPROVSTÅNG ALU 67-110CM<br />

09-MRE2402 09-MRE2402 RELÄKORT 2 RELÄER<br />

09-NAS NAS SAMPLINGSCENTRAL EXL. DETEKT<br />

09-ORPA3 80.474.679 PÄRM A3 FÖR O-RITNINGAR<br />

09-PAX3 40031 REN RÖK PURE-AX:3, 10ST/ASK<br />

09-PAX9 40032 REN RÖK PURE AX:9, 10ST/ASK<br />

09-PLUGG1 610-169 8 POL PLUGG CFP800<br />

09-PLUGG2 610-170 6 POL PLUGG CFP800<br />

09-POL-1 LIB-402F+C/POLLING SLINGTESTARE<br />

09-PROV 100 BRST 01-100-220 PROVSTÅNG 120-220<br />

09-PROV 160 BRST 02-160-450 PROVSTÅNG 160-450CM<br />

09-RHM075 RHM075 HISSSATS FÖR RÖKDETEKTORER<br />

09-S100 SOLO100-001 TELESKOPSTÅNG 4,5M<br />

09-S101 SOLO101-001 FÖRLÄNGNINGSSTÅNG 1,13M<br />

09-S200 SOLO200-001 NEDTAGNINGSDON TYP S<br />

09-S300 SOLO330-001 RÖKDETEKTOR TEST EXL FLASKA<br />

09-S461 SOLO 461-001 VÄRMEDETEKTORPROVARE TYP S<br />

09-SIM 124-296 LOOP SIMULATOR NF1000<br />

09-SKYLT1 09-SKYLT1 SKYLT BRANDLARM<br />

09-SKYLT2 09-SKYLT2 SKYLT DOLD DETEKTOR<br />

09-SKYLT3 09-SKYLT3 SKYLT DUBBEL"UTR.LARM/BRANDLARM"<br />

09-SKYLT4 09-SKYLT4 UTRYMNINGSLARM GRÖN DUBBEL<br />

09-SOCKELSKYDD BC SKYDD TILL DETEKTORSOCKLAR<br />

09-SPLINTAX 40091 RÖKTÄNDSTICKA, GRÅ 20ST/ASK<br />

09-STI 1130/BS STI 1130/BS HUV TILL LTK MED SUMMER<br />

09-STI6535 STI6535 KAPSLING LARMKNAPP UTOMHUS<br />

09-VP16 VP16 VERSAPOLE TELESKOP<br />

09-VP4X VP4X VERSAPOOL F-STÅNG 1,2M<br />

09-VT1 VT1 VERSATEST HÅLLARE FÖR TESTGAS<br />

09-VTKIT VTKIT-1 VERSATOOL STARTKIT<br />

09-WB1 WB1 TILLÄGGSSOCKEL F VÅTUTRYMME<br />

124-345-002 124-345-002 2-sektioner reservkort för NFS<br />

124-345-004 124-345-004 4-sektioner reservkort för NFS<br />

124-345-008 124-345-008 8-sektioner reservkort för NFS<br />

124-346 124-346 Reserv Strömförsörjningskort NFS<br />

28-020-713 020-713 BRAND/FELRELÄ NFS 2-8<br />

28-HO2 002-479-322 BRANDCENTRAL 2 SEKT.KONV<br />

28-HO4 002-479-342 BRANDCENTRAL 4 SEKT.KONV<br />

28-HO8 002-479-382 BRANDCENTRAL 8 SEKT.KONV<br />

28-KOND-10 020-743 STABILISERINGSKOND.8x10uF<br />

28-NFS2-S 002-477-329 BRANDCENTRAL NFS 2 SEKT.KONV<br />

28-NFS4-S 002-477-349 BRANDCENTRAL 4 SEKT.KONV<br />

Release 2<br />

2008


Crosslist<br />

Old article no New article no Benämning Svensk<br />

28-NFS8-S 002-477-389 BRANDCENTRAL 8 SEKT.KONV<br />

28-RKIT 020-745-008 RESERVDELSKIT NFS 2-8<br />

30-020-485-009 020-485-009 TÄCKNING UTÖKAD FRONT U SEK-INTF<br />

30-020-661 020-661 Diagnosverktyg för ID2-NET<br />

302-194 302-194 Värmedetektor, 95C, vertikal mont.<br />

30-BACKBOX-DU 020-475-009 BACKBOX DUBBELT UTÖKAD<br />

30-BACKBOX-DUD 020-476-009 BACKBOX DUBBELT UTÖKAD DJUP<br />

30-BACKBOX-S 020-472-009 BACKBOX ID3000 STANDARD<br />

30-BACKBOX-SSU 020-508-009 STD SEPARAT UTÖKNINGSBOX<br />

30-BACKBOX-SSUD 020-509-009 STD SEPARAT UTÖK.BOX DJUP<br />

30-BACKBOX-U 020-473-009 BACKBOX UTÖKAD<br />

30-BACKBOX-UD 020-474-009 BACKBOX UTÖKAD DJUP<br />

30-BAS3000 020-538-003 GRUNDENHET ID3000, INKL 2 SLINGOR<br />

30-BASKORT 020-568 BOTTENKORT ID3000<br />

30-BB/PSU 020-541-009 EXTERN KAPSLING PSU 7A/ACK<br />

30-CENTRAL3002-DK 002-303-003 BRANDCENTRAL ID3000 FIX 2 LOOP<br />

30-CPU3000 020-569 PROCESSORSKORT ID3000<br />

30-DUAL TPBK 020-543 BOOSTER INTERFACE PSU 7A<br />

30-ELIB 020-549 UTÖKAT SLINGKORT 2 SLINGOR<br />

30-FRONT-DU 020-621-009 FRONT DUBBELT UTÖKAD<br />

30-FRONT-S 020-480-009 FRONT STANDARD<br />

30-FRONT-S/RF 020-576 FRONT SDT ROSTFRITT STÅL<br />

30-FRONT-U 020-481-009 FRONT UTÖKAD<br />

30-HUVUDMODUL 3000 020-538-003 GRUNDENHET ID3000<br />

30-ID2NET 002-647 NÄTVERKSKORT FÖR ID2 NET<br />

30-ID2NET-FIBER 002-643 ID2 NET FIBER<br />

30-KABEL2M 082-171-006 FÖRLÄNGD KABEL (2M) SEKT.INTERF<br />

30-LIB 020-588 SLINGKORT ID3000, 2 SLINGOR<br />

30-OR3000 400133 OR-SKÅP ID3000<br />

30-PSU 020-484 STRÖMFÖRSÖRJNING ID3000 2,5A<br />

30-PSU 3A 020-648 STRÖMFÖRSÖRJNING ID3000 3A<br />

30-PSU 7A 020-579 STRÖMFÖRSÖRJNING ID3000 7A<br />

30-RAM-DU 020-040-009 INB.RAM DUBBELT UTÖKAD BACKBOX<br />

30-RAM-S 020-038-009 INB.RAM STANDARD BACKBOX<br />

30-RAM-S/RF 020-585 INB.RAM STD ROSTFRITT STÅL<br />

30-RAM-U 020-039-009 INB.RAM UTÖKAD BACKBOX<br />

30-RS232 020-478 KOMM.KORT FÖR TREDJE PART<br />

30-RS485 020-479 KOMM.KORT FÖR NÄTVERK<br />

30-SEK 1-256 020-612 SEKT.INTERFACE ID3000 256 SEKT<br />

30-SEK 1-64 020-559-001 SEKT.INTERFACE ID3000 1-64 SEKT<br />

30-SEK 65-128 020-559-002 SEKT.INTERFACE ID3000 65-128 SEKT<br />

30-SKRIVARE 020-644-009 SKRIVARE MONTAGE I SEKT.INTERFACE<br />

30-SKRIVARE2 020-708-009 SKRIVARE I FRONT INKL TÄCKPLÅT<br />

334-067-006 334-067-006 Reservnyckel röd för NFS<br />

5601P 5601P Värmedetektor 5601P<br />

60-CENTRAL60 002-456-003 BRANDCENTRAL ID50 ANALOG<br />

60-KKID60 020-638-003 BOTTENKORT ID60<br />

60-OR60 400179 OR-SKÅP ID 60<br />

60-RAM 020-599-009 INFÄLLNADSRAM ID50/60<br />

60-RS485 020-553 KOMM.KORT FÖR TREDJE PART<br />

ABS32/B ABS32/B Sockelsiren, svart, analog<br />

ABS32/B-I ABS32/B-I Sockelsiren, svart, isol, analog<br />

ABS32/PW ABS32/PW Sockelsiren, vit, analog<br />

ABS32/PW-I ABS32/PW-I Sockelsiren, vit, isol, analog<br />

ABS32/R ABS32/R Sockelsiren, röd, analog<br />

ABS32/R-I ABS32/R-I Sockelsiren, isolator, analog<br />

ABS32/W ABS32/W Sockelsiren, analog<br />

ABS32/W-I ABS32/W-I Sockelsiren, vit, isol, analog<br />

ABSB32/B/C ABSB32/B/C Sockelsiren, blixtljus, analog, svart<br />

ABSB32/B/C-I ABSB32/B/C-I Sockelsiren, isol, blixtlj, analog, svart<br />

ABSB32/PW/C ABSB32/PW/C Sockelsiren, blixtljus, analog, vit<br />

ABSB32/PW/C-I ABSB32/PW/C-I Sockelsir, isol, blixtlj, analog, vit<br />

Release 2<br />

2008


Crosslist<br />

Old article no New article no Benämning Svensk<br />

ABSB32/R/C ABSB32/R/C Sockelsiren, blixtljus analog, röd<br />

ABSB32/R/C-I ABSB32/R/C-I Sockelsiren, isol, blixtlj, analog, röd<br />

ABSB32/W/C ABSB32/W/C Sockelsiren medblixtljus, analog<br />

ABSB32/W/C-I ABSB32/W/C-I Sockelsiren, isol, blixtlj, analog<br />

AWB/R AWB/R Blixtljus, analog<br />

AWB/R-I AWB/R-I Blixtljus med isolator analog<br />

AWS32/R AWS32/R Siren, röd, analog<br />

AWS32/R-I AWS32/R-I Siren med isolator, röd, analog<br />

AWS32/W AWS32/W Siren, vit, analog<br />

AWS32/W-I AWS32/W-I Siren med isolator, vit analog<br />

AWSB32/R/R AWSB32/R/R Siren med blixtljus, röd analog<br />

AWSB32/R/R-I AWSB32/R/R-I Siren blixtljus, röd, isol, analog<br />

AWSB32/W/R AWSB32/W/R Siren med blixtljus, vit analog<br />

AWSB32/W/R-I AWSB32/W/R-I Siren blixtljus, vit, isol, analog<br />

B524HTR B524HTR Sokkel med värme, analog<br />

BEAM-HK BEAM-HK Värmeelement för SS Linjedetektor<br />

BEAM-HKR BEAM-HKR Värmeelement för reflektor<br />

DBSPD DBSPD Avstandsring för AVAX sokkel<br />

DH400ACDC-E DH400ACDC-E Kanaldetektor ACDC<br />

FD851TE FD851TE Värmdetektor max 58°C<br />

HFW-CP-01 SGCP100 Trådlös larmknapp, analog<br />

HFW-EM-01 SGWE Trådlös sändare/mottagare för trådlös detektor<br />

HFW-IM-01 SGMI100 Trådlös ingångsmodul 1 ingång, analog<br />

HFW-MA-01 SG200 Trådlös multikriterie detektor, analog<br />

HFW-OM-01 SGMC100 Trådlös utgångsmodul 1 utgång, analog<br />

HFW-PA-01 SG100 Trådlös optisk rökdetektor, analog<br />

HFW-PB-01 CR-123 Primärt batteri för trådlösa HFW<br />

HFW-SB-01 CR-2032 Sekundärt batteri för trådlösa HFW<br />

HFW-STK-01 SGW2W Kontroll och testkit för trådlös HFW<br />

HFW-TA-01 SG350 Trådlös termisk detektor, analog<br />

IDP-RM1 SG-IDP-RM1 Radio interface modul<br />

IRX-751CTEM IRX751CTEM SMART4 Multidetektor<br />

IRX-751CTEM IRX751CTEM SMART4 Analog multi detektor<br />

LPBW LPBW Sockel lågprofil<br />

NAS-2 NAS-2 NAS-2 Aspirasjons central<br />

New STI 9605 Steel web stoppers 115x175mm for Detector<br />

New STI 9707 Steel web stopper 280x244x140mm for Beam<br />

New 20/20SI TRIPLE IR DETECTOR<br />

New 20/20L UV/IR DUAL DETECTOR<br />

New 20/20U UV DETECTOR<br />

New FD-D1001 UV FLAME DETECTOR<br />

New BEAM-LRK LONG-RANGE REFLECTOR (75M-100M)<br />

New MPC3A-R000FF-01IS IS Manual Call Point Conv.<br />

New WCP3A-R000SF-01IS IS Manual Call Point Conv. IP67<br />

ORFS02 21980.200 OR-skåp FS02<br />

ORS-3S ORS-3S Ritningsskåp A3 svart<br />

PS230 PS230 Flexibelt "glas" för larmknapp<br />

S713AT S713AT Adapter 713<br />

SC070 SC070 10 st testnycklar för larmknapp<br />

SDBD SDBD Sockel för AV, djup<br />

SDBK SDBK Sockel för AV, djup, svart<br />

SDBR SDBR Sockel för AV, djup, röd<br />

SDBW SDBW Sockel för AV, djup, vit<br />

SGRS100 SGRS100 Trådlös siren, väggmonterad<br />

TG-IP-1 TG-IP-1 Notimaster TCP/IP interface<br />

WDBD WDBD Sockel för AV, djup, kapslad<br />

WDBK WDBK Sockel för AV, djp, svart, kapslad<br />

WDBR WDBR Sockel för AV, djup, röd, kapslad<br />

WDBW WDBW Sockel för AV, djup, vit, kapslad<br />

Release 2<br />

2008


HONEYWELL LIFE SAFETY<br />

GENERAL CONTACT DATA<br />

Customer support centre<br />

Ordercenter<br />

nordic.orders@honeywell.com<br />

Return<br />

nordic.return@honeywell.com<br />

Finance<br />

nordic.finance@honeywell.com<br />

Customer support centre<br />

Order / Return / Finance<br />

merja.lassila@honeywell.com<br />

SWEDEN: NORWAY:<br />

Honeywell Life safety AB Honeywell Life Safety AS<br />

Arenavägen 27 Lierstranda Industriområde<br />

Box 10122 Postboks 3514<br />

121 28 STOCKHOLM-GLOBEN N-3007 Drammen<br />

Tel +46 8 775 56 60 Tel +47 32 24 48 00<br />

www.<strong>notifier</strong>.se www.<strong>notifier</strong>.no<br />

DENMARK: FINLAND:<br />

Resprecented through Sweden. Honeywell Life Safety OY<br />

(See Swedeish cantact details) Lakalaivankatu 7<br />

www.<strong>notifier</strong>.dk 33840 TAMPERE<br />

Puh +358 207 522 550<br />

www.<strong>notifier</strong>.fi

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!