Bulletin Number: CAN044<br />

Date: July 20, 2009<br />

<strong>Description</strong>: <strong>Envirosense</strong> <strong>®</strong> <strong>PDV</strong> <strong>Electrical</strong> <strong>Connections</strong><br />

Reference GSW Model Numbers: 6G50100NVC02 and 6G50100PVC02<br />

<strong>This</strong> <strong>product</strong> notification serves to clarify the electrical connection requirements<br />

for the <strong>Envirosense</strong> <strong>®</strong> 6G50100NVC02 and 6G50100PVC02.<br />

The manual (P/N 316312-000) does not specifically outline a procedure for the<br />

electrical connection of these units. Included in this notification is a procedure<br />

that is recommended.<br />

NOTE: Where there is a procedure or practice applicable to the electrical<br />

connections for the <strong>Envirosense</strong> <strong>®</strong> <strong>PDV</strong> units documented subsequent to the<br />

publication of this notification, this notification is superseded.<br />

For further information, please contact our technical support team at 1 888 479<br />

8324.<br />

GSW Water Heating<br />

A Division of A. O.Smith Enterprises Ltd.<br />

599 Hill Street West<br />

Fergus, Ontario N1M 2X1<br />

1-888-479-8324<br />

www.gsw-wh.com Page 1 of 5


<strong>Envirosense</strong> <strong>®</strong> <strong>PDV</strong><br />

ELECTRICAL CONNECTIONS<br />

In addition to the installation instructions found in this notification, the water<br />

heater must be installed in accordance with all local and provincial codes or, in<br />

absence of local and provincial codes, with the latest edition of the “Canadian<br />

<strong>Electrical</strong> Code”.<br />

The requirements of these documents must be carefully followed in all cases.<br />

Authorities having jurisdiction shall be consulted before installations are made.<br />

Important: Installation and service must be performed by a qualified service<br />

technician.<br />

FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS NOTIFICATION MAY<br />

RESULT IN DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY<br />

DAMAGE. THOROUGHLY READ ALL INSTRUCTIONS BEFORE YOU<br />

ATTEMPT TO INSTALL, OPERATE OR MAINTAIN THE HEATER.<br />

GSW Water Heating<br />

A Division of A. O.Smith Enterprises Ltd.<br />

599 Hill Street West<br />

Fergus, Ontario N1M 2X1<br />

1-888-479-8324<br />

www.gsw-wh.com<br />

WARNING<br />

<strong>Electrical</strong> Shock Hazard<br />

Disconnect power before servicing.<br />

Replace all parts and panels before<br />

operating.<br />

Failure to do so can result in death or<br />

electrical shock.<br />

When making the electrical connections, always make sure:<br />

• The voltage and frequency correspond to that specified on the water<br />

heater data plate on the front of the water heater.<br />

• The electrical supply has the proper overload fuse or breaker protection.<br />

• Wire sizes and connections comply with all applicable codes.<br />

• Wiring is enclosed in approved conduit (if required by local codes).<br />

• The water heater and electrical supply are properly grounded.<br />

Product Notification CAN044<br />

Page 2 of 5 July 2009


<strong>This</strong> water heater may be hard wired or have a proper, three-prong polarized<br />

plug (with a maximum 12’ (365 cm) cord) installed and plugged directly into an<br />

electrical socket – do not use an extension cord.<br />

Note: Always reference the wiring diagram in the most current revision of the<br />

<strong>product</strong> manual for the correct electrical connections.<br />

If hard wiring the water heater:<br />

1. Shut off the power at the electrical service box.<br />

2. Loosen the screws securing the cover to the junction box.<br />

3. Pull wire ends into the junction box.<br />

4. Connect the electrical supply to the water heater in accordance with<br />

local utility requirements and codes. Use only a dedicated electrical<br />

circuit containing a properly sized fuse or circuit breaker. Maximum<br />

overload protection should not exceed 15 amperes.<br />

5. Place the wiring connections in the junction box and replace the cover.<br />

6. Connect this circuit (directly from the electrical service box) to an<br />

electrical disconnect switch.<br />

7. Ground the water heater by connecting the electrical service ground<br />

wire to the green ground wire (provided).<br />

GSW Water Heating<br />

A Division of A. O.Smith Enterprises Ltd.<br />

599 Hill Street West<br />

Fergus, Ontario N1M 2X1<br />

1-888-479-8324<br />

www.gsw-wh.com<br />

Note: The power supply to this water heater must be properly<br />

polarized (120 Volts from the hot lead (black) to ground and 0 Volts<br />

from the neutral lead (white) to ground), otherwise the unit will not<br />

operate.<br />

8. After making all electrical connections, completely fill the tank with<br />

water and check all connections for leaks. Open the nearest hot water<br />

faucet and let it run for 3 minutes to purge the water lines of air and<br />

sediment and ensure complete filling of the tank. The electrical power<br />

may then be turned on.<br />

If installing a three-prong plug for the water heater:<br />

1. Loosen the screws securing the cover to the junction box.<br />

2. Pull wire ends into the junction box.<br />

3. Insert the wiring for the three-prong plug into the junction box.<br />

Product Notification CAN044<br />

Page 3 of 5 July 2009


4. Wire the three-prong plug to the water heater wiring, ensuring the<br />

proper polarity and grounding.<br />

GSW Water Heating<br />

A Division of A. O.Smith Enterprises Ltd.<br />

599 Hill Street West<br />

Fergus, Ontario N1M 2X1<br />

1-888-479-8324<br />

www.gsw-wh.com<br />

Note: The power supply to this water heater must be properly<br />

polarized (120 Volts from the hot lead (black) to ground and 0 Volts<br />

from the neutral lead (white) to ground), otherwise the unit will not<br />

operate.<br />

5. Place the wiring connections in the junction box and replace the cover.<br />

After installing the three-prong plug, completely fill the tank with water<br />

and check all connections for leaks. Open the nearest hot water faucet<br />

and let it run for 3 minutes to purge the water lines of air and sediment<br />

and ensure complete filling of the tank. The electrical power may then<br />

be turned on.<br />

Product Notification CAN044<br />

Page 4 of 5 July 2009


Wiring Diagram for <strong>Envirosense</strong> <strong>®</strong> <strong>PDV</strong><br />

GSW Water Heating<br />

A Division of A. O.Smith Enterprises Ltd.<br />

599 Hill Street West<br />

Fergus, Ontario N1M 2X1<br />

1-888-479-8324<br />

www.gsw-wh.com<br />

Product Notification CAN044<br />

Page 5 of 5 July 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!