1. All work performed shall comply with the contract documents, drawings and<br />

specifications, including these general notes. The contractor shall coordinate the intent<br />

of the general notes with all trades.<br />

2. Specifications bound separately are part of the contract documents.<br />

3. The organization of the drawings and specifications shall not control the contractor in<br />

dividing the work among subcontractors or in establishing the extent of work to be<br />

performed by any trade.<br />

4. All materials and workmanship shall conform to the drawings and specifications. If any<br />

conflict is found between the drawings, general notes and specifications, consult the<br />

architect for clarification before proceeding with the work.<br />

5. No deviation from the contract drawings and specifications shall be made without written<br />

approval of the architect.<br />

6. The structural, mechanical, electrical and plumbing drawings are supplementary to the<br />

architectural drawings. It shall be the responsibility of the contractor to check with the<br />

architectural drawings before the installation of structural, mechanical, electrical or<br />

plumbing work. Should there be a discrepancy between the architectural drawings and<br />

the consulting engineer’s drawings that would cause an awkward installation, it shall be<br />

brought to the architect’s attention for clarification prior to installation of said work. Any<br />

work installed in conflict with the architectural drawings shall be corrected by the<br />

contractor at no additional cost.<br />

7. Do not scale drawings. Dimensions shall take precedence over scales shown on<br />

drawings. General contractor shall verify all dimensions, grades and conditions at the site<br />

prior to commencing the work and report any discrepancies to the architect in writing.<br />

8. All symbols and abbreviations used on the drawings are considered to be construction<br />

standards. If the contractor has questions regarding same or their exact meaning, the<br />

architect shall be notified for clarification.<br />

9. Where a typical condition is detailed, it shall be understood that all like or similar<br />

conditions are the same unless specifically noted or detailed otherwise.<br />

10. All dimensions are to center line of column, face of concrete or face of scheduled partition<br />

unless otherwise noted.<br />

11. Finish floor elevations are too top of concrete unless otherwise noted.<br />

<strong>12</strong>. Finish ceiling elevations are to finished surfaces.<br />

13. Contractor shall provide construction barricades or fencing as required and as approved<br />

by the city for public safety prior to commencing the work.<br />

14. Fire protection equipment and service access must be provided during the construction<br />

period as required by the city fire marshall.<br />

15. Contractor shall provide temporary exit signs to assure a means of egress during<br />

construction.<br />

16. Contractor shall as necessary provide shoring designed and detailed by a California<br />

registered engineer.<br />

17. Contractor shall obtain a grading permit for this project.<br />

<strong>18</strong>. Contractor shall obtain necessary permits from State of California Division of Industrial<br />

Safety, OSHA Department, for trenches or excavations greater than 5’-0” deep into which<br />

a person is required to descend for construction purposes.<br />

19. Public improvements and services adjacent to the site shall be maintained during<br />

construction. Approval of the city engineering department is required before any work is<br />

commenced.<br />

20. Contractor shall coordinate site plumbing, drainage, electrical, telephone work and<br />

existing utilities to provide a complete operating system.<br />

21. Except where shown in dimensional detail, the locations of plumbing, mechanical<br />

equipment, ducts piping and fitting are only approximate. The exact locations shall be<br />

determined by the contractor subject to approval by the architect.<br />

22. Contractor shall verify sizes and locations of all mechanical equipment pads and bases as<br />

well as power and water or drain installations with equipment manufacturers before<br />

proceeding with the work.<br />

23. Contractor shall verify size and location of all mechanical openings through the roof with<br />

mechanical equipment manufactures.<br />

24. Contractor shall provide and install all stiffeners, bracing, blocking, back-up plates and<br />

supporting brackets required for the installation of all casework, toilet room accessories,<br />

fixtures and partitions and all wall mounted or suspended mechanical, electrical or<br />

miscellaneous equipment and furnishings.<br />

25. Egress stair shafts shall be airtight and sealed.<br />

26. Mechanical supply and return air shafts shall be airtight and sealed.<br />

27. Offset studs where required so that finish wall surfaces will be flush.<br />

28. Duct penetrations of fire rated walls, floors or roofs shall have fire dampers per LABC<br />

section 713. Dampers must be located at the point where the rated barrier is pierced.<br />

29. Penetrations in walls, floors or roof requiring protected openings shall be fire-stopped in<br />

accordance with LABC section 713.<br />

30. Interior wall and ceiling finishes shall comply with LABC section 803.<br />

31. Roofing system shall bear UL listing as a class “A” system. All manufactured materials<br />

used shall bear the appropriate UL label.<br />

32. Contractor shall verify all concrete and masonry openings in the field prior to fabrication of<br />

doors and frames.<br />

33. Minimum headroom clearance at stairs shall be 7’-0” measured vertically from the plan<br />

tangent to the tread nosing to the surface above.<br />

34. The installation of emergency fuel storage tanks must be checked and approved by the<br />

fire department prior to installation.<br />

35. Contractor shall review the location and mounting heights of the toilet room accessories<br />

with the building inspector prior to installation to assure correct positioning in accordance<br />

with accessibility code.<br />

36. Toilet rooms shall be equipped with a mechanical system of ventilation providing a<br />

minimum of four air changes per hour or as required by code.<br />

37. Provide collision barriers adequate to protect control meters, regulators, and piping for<br />

hazardous material that are exposed to vehicular damage.<br />

38. Parking spaces shall not obstruct required exits.<br />

39. A separate interior improvement permit is required for this project.<br />

40. Provide portable fire extinguishers as required as follows:<br />

a. Parking: Rating of not less than 2A-10BC, 1 per 3,000 sq. ft. within 75 foot travel<br />

distance to all portions of the structure on each floor.<br />

b. Office: Rating of not less than 2A-10BC, 1 per 6,000 sq. ft. within 75 foot travel<br />

distance to all portions of the structure on each floor.<br />

c. Theater: rating of not less than 2A-10BC, 1 per 6,000 sq. ft. within 75 foot travel<br />

distance to all portions of the structure on each floor.<br />

d. Retail: Rating of not less than 2A-10BC, 1 per 3,000 sq. ft. within 75 foot travel<br />

distance to all portions of the structure on each floor.<br />

e. Residential: Rating of not less than 2A-10BC, 1 per 6,000 sq. ft. within 75 foot travel<br />

distance to all portions of the structure on each floor.<br />

f. Restaurant: Rating of not less than 2A-10BC, 1 per 3,000 sq. ft. within 75 foot travel<br />

distance to all portions of the structure on each floor.<br />

99. Each pane of safety glazing installed in hazardwous locations shall be identified by a<br />

manufacturer's designation specifying who applied the designation, the manufacturer or<br />

installer and the<br />

safety glazing standard. Glazing in:<br />

a. Swing doors<br />

b. Fixed and sliding panels of sliding door assemblies and panels in sliding and bi-fold closet<br />

door assemblies.<br />

c. Storm doors.<br />

d. Unframed swinging doors.<br />

e. Doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and<br />

showers.<br />

f. Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing<br />

is with a 24" arc of either a vertical edge of the door in a closed position and<br />

where the bottom exposed<br />

edge of the glazing is less than 60" above the walking<br />

surface.<br />

g. Fixed or operable panel, other than described in items e. & f., which meets all of the following<br />

conditions:<br />

1. Exposed area of an individual pane greater than 9 sf.<br />

2. Exposed bottom edge less than <strong>18</strong>" above the floor.<br />

3. Exposed top edge greater than 36" above the floor.<br />

4. One or more walking surfaces within 36" horizontally of the plane of the glazing.<br />

h. Guards & railings regardless of area of height above a walking surface. Included are<br />

structural baluster panels and non- structural in-fill panels.<br />

i. Walls and fences enclosing indoor and outdoor swimming pools and spas where all of the<br />

following conditions are present:<br />

1. The bottom edge of the glazing is less than 60" above the walking surface on the<br />

pool or spa side of the glazing.<br />

2. The glazing is within 60" of a swimming pool or spa water's edge.<br />

j. Adjacent to stairways, landing and ramps within 36" horizontally of a walking surface; when<br />

the exposed surface of the glass is less than 60" above the plane of the<br />

adjacent walking<br />

surface.<br />

k. Adjacent to stairways within 60" horizontally of the bottom tread of a stairway in any<br />

direction when the exposed surface of the glass is less than 60" above the nose of<br />

the tread.<br />

100. Detail guards when located along open-sided walking surfaces, mezzanines, industrial equipment<br />

platforms, stairways, ramps and landings that are located more than 30"<br />

above the floor or grade<br />

below.<br />

a. 42" minimum height<br />

b. Intermediate rails or ornamental patterns such that a 4" diameter sphere cannot pass through.<br />

c. Shall be designed for a 50 plf applied in any direction at the top and to transfer the load<br />

thru the supports of the structure.<br />

d. Shall be designed for a 200 lb concentrated load applid in any direction at any point along<br />

the top.<br />

e. Glass panel guardrail shall design fro a factor of safety equal to 4.0 minimum.<br />

Designer to specify approved report number and manufacturer of glass panel<br />

guardrail on<br />

plans and/or detail.<br />

101. Occupied spaces shall be provided with natural ventilation by means of readil controllable exterior<br />

openings with an area note less than 4% of the total floor area. Such exterior<br />

openings shall open<br />

directly to the outdoors or to a yard or court that complies with<br />

Section <strong>12</strong>06. Where natural<br />

ventilation is not provided, submit to the Mechanical<br />

Section for compliance with the County of Los<br />

Angeles Mechanical Code.<br />

102. Occupancies and operations involving flammable or combustible hazards or other<br />

contaminant sources shall submit to the Mechanical Section for compliance with the<br />

County of Los<br />

Angeles Mechanical Code.<br />

103. Interior finish materials applied to wall and ceilings shall be tested as specified in Section 803. See<br />

details showing application in accordance with Section 803.1 and Table 803.9.<br />

1<strong>04</strong>. The flame spread index of interior wall and ceiling finish within a corridor, lobby and exit enclosure<br />

must comply with Table 803.9.<br />

105. Except for light switches, where redundant controls are provided for a single element, one control<br />

in each space shall not be required to comply with Section 11B-309 Operable<br />

Parts.<br />

106. Maximum effort to operate doors or gates shall not exceed 8-1/2 pounds for exterior doors or<br />

gates and 5 pounds for interior doors or gates, such pull or push effort being<br />

applied at right angles to<br />

hinged doors or gates and at the center plane of sliding or<br />

folding doors. Compensating devices or<br />

automatic door or gate operators may be<br />

utilized to meet the above standards. When fire doors are<br />

required, the maximum effort<br />

to operate the door may be increased to minimum allowable by the appropiate<br />

adminstrative authority, not to exceed 15 pounds. 1<strong>12</strong>6A.4<br />

107. If the door or gate has a closer, the sweep period of the closer shall be adjusted so that from an open<br />

position of 90 degrees, the door or gate will take 5 seconds minimum to<br />

move to a position of <strong>12</strong> degress<br />

from the latch. 1<strong>12</strong>6A.4.1<br />

108. Hand activated door latching, locking, and opening hardware shall be centered between 30" and 44"<br />

above the floor. Latching and locking doors that are hand-activated and on<br />

an accessible route shall be<br />

operable with a single effort by lever-type hardware, panic<br />

bars, push-pull activating bars or other<br />

hardware designed to provide passage without<br />

requiring the ability to grasp the opening hardware.<br />

Locked exit doors shall operate consistent with Section 1132A.6, in the direction of egress. 1132A.8<br />

GENERAL NOTES (CONTINUED)<br />

Elevators<br />

1. Provisions of Chapter 30 that elevators must satisfy:<br />

3002 - Hoistway Enclosures<br />

30<strong>04</strong> - Hoistway Venting<br />

3006 - Machine Rooms<br />

2. Elevators provided for passengers shall comply with 11B-407 Elevators. Where multiple elevators are<br />

provided, each elevator shall comply with 11b-407 Elevators (See exceptions)<br />

3. Elevators shall comply with 11B-407 Elevators and with ASME A17.1. They shall be passenger elevators as<br />

classified by ASME A17.1. Elevator operation shall be automatic. When the only elevators provided for use by<br />

the public and employees are combination passenger and freight elevators, they shall comply with 11B-407<br />

Elevators and with ASME A17.1<br />

4. Where elevator call buttons or keypads are provided, they shall comply with 11B-407.2.1 Call Controls and<br />

11B-309.4 Operation.<br />

5. Call buttons and keypads shall be located within one of the reach ranges specified in 11B-308 Reach Ranges,<br />

measured to the centerline of the highest operable part.<br />

6. Call buttons shall have square shoulders, be 3/4" minimum in the smallest direction and shall be raised 1/8"<br />

plus or minus 1/32" above the surrounding surface. The buttons shall be activated by a mechanical motion that is<br />

detectable.<br />

7. A clear floor or ground space complying with 11B-305 Clear Floor or Ground Surface shall be provided at call<br />

controls.<br />

8. Except at destination oriented elevators, visible signal fixtures shall be centered at 72" minimum above the<br />

finish floor or ground. The visible signal elements shall be a minimum 2 1/2" high by 2 1/2" wide. Signals shall be<br />

visible from the floor area adjacent to the hall call button.<br />

9. Floor designations complying with 11B-703.2 Raised Characters and 11B-703.4.1 Height Above Finish Floor or<br />

Ground shall be provided on both jambs of elevator hoistway entrances. Floor designations shall be provided in<br />

both raised characters and Braille. Raised characters shall be 2" high. A raised star, placed to the left of the floor<br />

designation shall be provided on both jambs at the main entry level. The outside diameter of the star shall be 2"<br />

and all points shall be of equal length. Raised characters, including the star, shall be white on black background.<br />

Braille complying with Section 11B-703.3 Braille shall be placed below the corresponding raised characters and<br />

the star. The Braille translation for the star shall be "MAIN". Applied plates are acceptable if they are permanently<br />

fixed to the jamb.<br />

10. Destination oriented elevators shall provide tactile car identification complying with 11B-703.2 Raised<br />

Characters and 11B-703.4.1 Height Above Finish Floor or Ground on both jambs of the hoistway immediately<br />

below the floor designation. Car designations shall be provided in both raised characters and Braille. Raised<br />

characters shall be 2" high. Raised characters shall be with on black background. Braille complying with Section<br />

11B-703.3 Braille shall be placed below the corresponding raised characters. Applied plates are acceptable if<br />

they are permanently fixed to the jamb.<br />

11. Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited.<br />

<strong>12</strong>. Elevator hoistway and car doors shall open and close automatically.<br />

13. The width of elevator doors shall comply with Table 11B-407.4.1.<br />

14. Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 11B-407.4.1<br />

15. Floor surfaces in elevator cars shall comply with 11B-302 Floor or Ground Surfaces and 11B-303 Changes in<br />

Level.<br />

16. The clearance between the car platform sill and the edge of any hoistway landing shall be 1 1/4" maximum.<br />

17. Elevator car controls shall be located within one of the reach ranges specified in 11B-308 Reach Ranges.<br />

<strong>18</strong>. Car control buttons with floor designations shall comply with the following:<br />

A. Buttons shall have square shoulders, be 3/4" minimum in their smallest dimension and be raised 1/8" plus or<br />

minus 1/32" above the surrounding surface.<br />

B. Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are<br />

provided, they shall be read from left to right.<br />

C. Car control buttons shall be illuminated.<br />

D. Car control buttons shall be activated by a mechanical motion that is detectable.<br />

19. Emergency control buttons shall have their centerlines 35" minimum above the finish floor.<br />

20. Emergency control buttons, including the emergency alarm, shall be grouped at the bottom of the panel.<br />

21. Car control buttons shall comply with the following:<br />

A. Control buttons shall be identified by raised characters or symbols, white on a black background, complying<br />

with 11B-703.2 Raised Characters and Braille complying with 11B-703.3 Braille.<br />

B. Raised characters of symbols an Braille designations shall be placed immediately to the left of the control<br />

button to which the designations apply.<br />

C. The control button for the emergency stop, alarm, door open, door close, main entry floor and phone shall be<br />

identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3.<br />

D. Buttons with floor designations shall be provided with visible indicators to show that a call has been registered,<br />

the visible indication shall extinquish when the car arives at the designated floor.<br />

E. A minimum clear space of 3/8" or other suitable means of separation shall be provided between rows of control<br />

buttons.<br />

22. Keypads shall be identified by characters complying with 11B-703.5 Visual Characters and shall be centered<br />

on the corresponding keypad button. The number five key shall have a single raised dot. The dot shall be 0.1<strong>18</strong>"<br />

to 0.<strong>12</strong>0" base diameter and in other aspects to comply with Table 11B-703.3.1.<br />

23. Audible and visible car position indicators shall be provided in elevator cars. Characters shall be 1/2" high<br />

minimum. Indicators shall be located above the car control panel or above the door.<br />

24. Emergency two-way communication systems shall comply with 11B-308 Reach Ranges. Raised symbols or<br />

characters, white on black background, and Braille shall be provided adjacent to the device and shall comply with<br />

11B-703.2 Raised Characters and 11B-703.3 Braille. Emergency two-way communications systems between the<br />

elevator and a point outside the hoistway shall comply with ASME A17.1.<br />

25. Support rails shall be provided on at least one wall of the car and shall comply with the following:<br />

A. Clearance between support rails and adjacent surfaces shall be 1 1/2" minimum. Top of support rails shall be<br />

31" minimum to 33" maximum above the floor of the car. The ends of the support rail shall be 6" maximum from<br />

adjacent walls.<br />

B. Support rails shall be smooth and any surface adjacent to them shall be free of sharp or abrasive elements.<br />

C. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds<br />

is applied at any point on the support rail, fastener, mounting device or supporting structure.<br />

41. Contractor shall review the locations of all fire life safety devices with the fire inspector<br />

and the architect for on-site approval prior to installation.<br />

42. Any time a building or a portion of a building is occupied, the means of egress serving<br />

the occupied portion shall be illuminated at an intensity of not less than 1-foot candle<br />

(11 lux) at the walking surface.<br />

43. All exit signs to have 6” high letters on a contrasting background.<br />

44. Exit signs shall be internally or externally illuminated. Internally illuminated exit signs<br />

shall be listed and labeled in accordance with UL 924 and shall be installed in<br />

accordance with the manufacturer's instructions and Chapter 27. Externally illuminated<br />

exit signs shall comply with the graphics and power source requirements in Sections<br />

1011.5.1 and 1011.5.3 respectively. When the face of an exit sign is illuminated from an<br />

external source, it shall have an intensity of not less than 5-foot candles.<br />

45. An approved exit sign shall be located at each floor level landing in all enclosed<br />

stairways. The sign shall indicate floor level, terminus of the top and bottom of the<br />

stairway and identification of the stairway. Floor designations shall be 5” high black<br />

numbers. Sign shall be located on or adjacent to doors at 5’-0” above finish floor level.<br />

46. Room capacity signs shall be posted in the structure prior to occupancy.<br />

47. Approved numbers or addresses shall be provided in such a position as to be plainly<br />

visible and legible from the street or road fronting the property.<br />

48. Glazed openings within 40” of the door lock when the door is in the closed position by<br />

metal bars, screens or grills having a maximum opening of 2”. The provisions of this<br />

section shall not apply to view ports or windows which do not exceed 2” in their greatest<br />

dimension.<br />

49. All work shall comply with the building code for the city of Los Angeles, amended<br />

ordinances, and all other applicable codes and regulations. All necessary licenses, test<br />

certificates etc. shall be paid for by the contractor.<br />

49. All materials furnished under this contract shall be new unless otherwise noted. All work<br />

shall be completed in a workmanlike manner and guaranteed against defective materials<br />

and workmanship for a period of one (1) year after completion and acceptance. The<br />

contractor shall repair or replace at his own expense all work that may develop defects<br />

in material or workmanship within said period of time.<br />

50. The contractor and subcontractor shall be responsible for checking existing job site<br />

conditions inspector for verification.(4.5<strong>04</strong>.4)<br />

51. The contractor shall verify and coordinate sizes, locations and dimensions of work and<br />

equipment to be furnished by others with the manufactures or supplier before any<br />

construction.<br />

52. Contractor shall be responsible for adequately bracing and protecting all work during<br />

construction against damage, breakage, collapse and misalignment according to<br />

applicable codes, standards and good construction practices.<br />

53. The contractor is responsible for cleanup of all trades and removal of all debris. Tenant<br />

space shall be left clean and ready for occupancy.<br />

54. Exit doors shall be operable from the inside without the use of a key or any special<br />

knowledge or effort.<br />

55. Rubbish and linen chutes: provide automatic sprinkler system at the top of chute and in<br />

the terminal room.<br />

56. Electrical outlet boxes in opposite faces of separation walls shall be separated<br />

horizontally by 24” and the back and sides of boxes shall be sealed with 1/8” resilient<br />

sealant and back by a minimum fiber insulation.<br />

57. All pin-type door hinges accessible from outside shall have non-removable hinge pins.<br />

Hinges shall have min. ¼” dia. steel jamb stud with ¼” protection. The strike plate for<br />

latches and holding device for projecting dead bolts in wood construction shall be<br />

secured to the jamb and the wall framing with screws no less than 1 ½ long.<br />

58. Straight bolts shall have a min. throw of 1” and an embedment of not less than 5/8” and<br />

a hook-shaped or expanding lung deadbolt shall have a minimum throw of ¾”.<br />

59. All entry doors to dwelling units or guest rooms shall be arranged so that the occupant<br />

has a view of the area immediately outside the door without opening the door. Such view<br />

may be provided by a door viewer, through windows located in the vicinity of the door or<br />

through view ports in the door or adjoining wall.<br />

60. Exit signs shall be internally or externally illuminated. When the face of an exit sign is<br />

illuminated from an external source, it shall have an intensity of not less than 5 foot<br />

candles from either of two electric lamps. Internally illuminated signs shall provide<br />

equivalent luminance and be listed for the purpose.<br />

61. Exit signs shall be connected to an emergency electrical system provided from storage<br />

batteries, unit equipment or an on-site generator set and the system shall be installed in<br />

accordance with the electrical code.<br />

62. An approved seismic gas shutoff valve shall be installed on the fuel gas line on the<br />

downstream side of the utility meter and be rigidly connected to the exterior of the<br />

building or structure containing the fuel gas piping.<br />

63. All commercial buildings shall be core and shell work only. Tenant improvements shall<br />

be permitted separately.<br />

64. Comply with lighting power requirements in the California Energy Code, California Code<br />

of Regulations (CCR), Title 24, Part 6, and design interior and exterior lighting such that<br />

zero direct-beam illumination leaves the building site. Meet or exceed exterior light levels<br />

and uniformity ratios for lighting zones 1-4 as defined in Chapter 10 of the California<br />

administrative Code, CCR, Title 24, Part 1, using the following strategies:<br />

1. Shield all exterior luminaires or provide cutoff luminaires per Section 132 (b)<br />

of the California Energy Code;<br />

2. Contain interior lighting within each source;<br />

3. Allow no more than .01 horizontal lumen foot candles to escape 15 feet<br />

beyond the site boundary;<br />

4. Automatically control exterior lighting dusk to dawn to turn off or lower light<br />

levels during inactive periods.<br />

Exceptions:<br />

1. Los Angeles Building Code, Chapter <strong>12</strong>, Section <strong>12</strong>05.6 for campus<br />

lighting requirements for parking facilities and walkways.<br />

2. Emergency lighting and lighting required for nighttime security.<br />

65. Buildings shall meet or exceed the provisions of California Building Code, CCR, Title 24,<br />

Part 2, Sections 1<strong>203</strong> (Ventilation) and Chapter 14 (Exterior Walls). (5.505.1)<br />

66. Fire retardant wood shall have a flame spread of 25 or less.<br />

67. Internally illuminated sings shall be listed and labeled and shall be installed in<br />

accordance with the manufacturer's instructions and Section 2702.<br />

68. Exit signs shall be illuminated at all times.<br />

69. Door handles, lock and other operating devices shall be installed at a min. 34" and a<br />

max. 48" above the finished floor.<br />

70. Where key-operated locking devices are used, post a sign on or adjacent to the required<br />

main exit door with 1-in. Lettering stating: “this door to remain unlocked when building is<br />

occupied.”<br />

71. All egress door operation shall comply with Section 1008.1.9 - 1008.1.9.7.<br />

72. The power supply for means of egress illumination shall normally be provided by the<br />

premises electrical supply. in the event of power supply failure, an emergency electrical<br />

system shall automatically illuminate the following areas:<br />

a. Aisles and unenclosed egress stairways in rooms and spaces that require two or<br />

more means of egress<br />

b. Corridors, exit enclosures and exit passageways in buildings required to have two or<br />

more exits.<br />

c. Exterior egress components at other than the level of exit discharge until exit<br />

discharge is accomplished for building require to have two or more exits.<br />

d. Interior exit discharge elements, as permitted in Section 1024.1, in buildings required<br />

to have two or more exits.<br />

e. Exterior landings, as required in Section 1008.1.5, for exit discharge doorways in<br />

buildings required to have two or more exits.<br />

73. The exit signs shall also be connected to an emergency electrical system which is to<br />

provide continued illumination for a duration of not less than 1 1/2 hour incase of primary<br />

power loss. Continued illumination is to be provided from storage batteries, unit<br />

equipment, or an onsite generator and the installation of the emergency power system<br />

shall be installed in accordance with Chapter 27.<br />

74. Emergency lighting facilities shall be arranged to provide initial illumination that is at<br />

least an average of 1-foot candle (11 lux) and a minimum at any point of 0.1-foot candle<br />

(1 lux) measured along the path of egress at floor level. A maximum to minimum<br />

illumination uniformity ratio of 40 to 1 shall not be exceeded.<br />

75. The path of egress travel to exits and within exits in this building shall be identified by<br />

exit signs conforming to the requirements of Section 1011 and as noted below:<br />

a. Exit signs shall be readily visible from any direction of egress travel.<br />

b. Exit signs shall be located as necessar to clearly indicate the direction of egress<br />

travel.<br />

c. No point in a corridor shall be more than 100 feet or the listed viewing distance for<br />

the sign, whichever is less, from the nearest visible exit sign.<br />

76. Temporary pedestrian protections shall be provided as required by Section 3306. Obtain<br />

Public Works approval (3201.3, 3202.3.4, 3306).<br />

77. An approved anti-graffiti coating shall be applied to the exterior walls for a min. of 9'-0"<br />

from finished grade.<br />

78. The construction shall not restrict a five-foot clear and unobstructed access to any water<br />

or power distribution facilities (power poles, pull-boxes, transformers, vaults, pumps,<br />

valves, meters, appurtenances, etc) or to the location of the hook-up. The construction<br />

shall not be within ten feet of any power lines - whether or not the lines are located on<br />

the property. Failure to comply may cause construction delays and or additional<br />

expenses.<br />

79. Shower compartments and walls above bathtubs with installed shower heads shall be<br />

finished with a smooth nonabsorbent surface to height not less than 70 inches above the<br />

drain inlet. Section <strong>12</strong>10.3. Use of water-resistant gypsum backing board shall be as<br />

state in Section 2509.3.<br />

80. Water heaters shall be strapped to a wall (Section 507.3 UPC).<br />

81. Provide automatic sprinkler system at top of rubbish and linen chutes and in their<br />

terminal room. (903.2.11.2)<br />

82. Class A roof covering is required for all buildings located in a Very High Fire Hazard<br />

Severity Zone. (1505.1, 7207.4)<br />

83. Deck Coating to comply with LARR #25299.<br />

84. Roofing Materials to comply with LARR #25271.<br />

85. Interior materials applied to walls and ceilings shall be specified in Section 802.<br />

Application should be in accordance with Section 803, 8<strong>04</strong> and Table 803.9<br />

86. The flame-spread rating of paneling materials on the walls of the corridor, lobby and exit<br />

enclosure must be identified on plans. (T803.9)<br />

87. Any decorations shall be non-combustible or flame-retardant treated in an approved<br />

manner (curtains, drapes, shades, hangings, etc.) (LAMC 57.22)<br />

88. Roof construction such as television antenna, guy wires, solar panels and razor ribbon<br />

shall not prevent Fire Department access or egress in the event of a fire. (LAMC 57.<strong>12</strong>)<br />

89. Roof covering shall conform to the Building Code.<br />

90. Conspicuously mark gas shut-off valve. (CCR Title 19)<br />

91. Recycled materials, including drywall, steel, aluminum, ceramic tile, cellulose insulation<br />

and composite engineered wood products, shall be incorporated into building design and<br />

construction where economically feasible and where compatible with design objectives.<br />

92. Pedestrians shall be protected during construction, remodeling and demolition activities<br />

as required by county of los angeles building code chapter 33.<br />

93. Any time a building or a portion of a building is occupied, the means of egress serving<br />

the occupied portion shall be illuminated at an intensity of not less than 1 foot candle<br />

(11 lux) at the walking surface level.<br />

94. Abrupt changes in level exceeding 4” in a vertical dimension between walks, sidewalks<br />

or other pedestrian ways and adjacent surfaces or features shall be identified by warning<br />

curbs at least 6” in height above the walk or sidewalk surface or by guards or handrails<br />

with a guiderail centered 2” minimum and 4” maximum above the surface of the walk or<br />

sidewalk. These requirements do not apply between a walk or sidewalk and an adjacent<br />

street or driveway. 11B.303.5<br />

95. Exit doors or gates shall be openable from the egress side without the use of a key,<br />

special knowledge or effort. Door handles, pulls, latches, locks and other operating<br />

devised shall be installed 34" to 48" above the finished floor. Manually operated flush<br />

bolts or surface bolts are not permitted. the unlatching of any door or leaf shall not<br />

require more than one operation.<br />

96. Provide tactile exit signs that comply with Section 1117B.5.1, Item 1. Tactile signs shall<br />

be required at the following locations:<br />

a. Each grade level exterior exit door shall be identified by "EXIT."<br />

b. Each exit door that leads directly to a grade level exterior exit by means of a stairway<br />

or ramp with the following words as appropiate:<br />

1. "EXIT STAIR DOWN"<br />

2. "EXIT RAMP DOWN"<br />

3. "EXIT STAIR UP"<br />

4. "EXIT RAMP UP"<br />

c. Each exit door that leads to an exit enclosure or an exit passagewaqy identified by<br />

"EXIT ROUTE."<br />

d. Each exit access door from an interior room or area thatis required to have a visual<br />

exit sign shall be identified by "EXIT ROUTE."<br />

e. Each exit door through a horizontal exit shall be identified by "TO EXIT."<br />

97. Interior exit enclosures connecting more than three stories above grade plane shall have<br />

an approved stairway sign indicating the floor level. Indicate whether or not there is roof<br />

access, the terminus of the top and bottom of the stair and the identification of the stair.<br />

The sign shall be located approximately 5' above the floor landing and shall be readily<br />

visible when the stair doors are in an open or closed position.<br />

98. Provide tactile stair level identification sign that complies with 11b-216.4 at each floor<br />

level landing.<br />

I<br />

RE<br />

DES<br />

ARCHITE<br />

PLOT ST<br />

PROJEC<br />

MA<br />

A<br />

G<br />

AP<br />

L<br />

PLA<br />

GENERAL NOTES<br />

REV<br />

REV<br />

REV<br />

REV

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!