01.11.2018 Views

Oracle 1Z0-489 Braindumps - The Easy Way to Pass SPARC M6-32 and SPARC M5-32 Server Certified Implementation Specialist 1Z0-489 Exam

-- Visit here for more: https://dumpsarchive.com/dumps/1Z0-489/ -- -- Reasons to Use Oracle 1Z0-489 dumps -- This is usually only possible with the aid of 1Z0-489 pdf questions and listed below are the reasons why we believe you should opt to purchase the 1Z0-489 exam questions. -- Incomparable 1Z0-489 dumps product Quality -- The 1Z0-489 exam questions will save you time that you might otherwise have spent wasting trying to look up the 1Z0-489 dumps and studying on your own, all to no avail. Instead you can make life easier for yourself by opting the 1Z0-489 pdf which has all the questions as they are coming in the Oracle 1Z0-489 Specialist exam along with the answers.

-- Visit here for more: https://dumpsarchive.com/dumps/1Z0-489/ --

-- Reasons to Use Oracle 1Z0-489 dumps --

This is usually only possible with the aid of 1Z0-489 pdf questions and listed below are the reasons why we believe you should opt to purchase the 1Z0-489 exam questions.

-- Incomparable 1Z0-489 dumps product Quality --

The 1Z0-489 exam questions will save you time that you might otherwise have spent wasting trying to look up the 1Z0-489 dumps and studying on your own, all to no avail.

Instead you can make life easier for yourself by opting the 1Z0-489 pdf which has all the questions as they are coming in the Oracle 1Z0-489 Specialist exam along with the answers.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Oracle</strong><br />

<strong>1Z0</strong>-<strong>489</strong> <strong>Exam</strong><br />

<strong>SPARC</strong> <strong>M6</strong>-<strong>32</strong> <strong>and</strong> <strong>SPARC</strong> <strong>M5</strong>-<strong>32</strong> <strong>Server</strong>s Installation Essentials<br />

Thank you for Downloading <strong>1Z0</strong>-<strong>489</strong> exam PDF Demo<br />

Buy Full Product Here:<br />

https://dumpsarchive.com/dumps/<strong>1Z0</strong>-<strong>489</strong>/<br />

Questions & Answers<br />

(Demo Version --- Limited Edition)


Question 1<br />

You enter the following comm<strong>and</strong> from the service processor; start<br />

accomplish?<br />

/HOSTO/console. What does this<br />

A. Log in <strong>to</strong> the domain as user root via the console.<br />

B. Log In <strong>to</strong> the host as user root from another system.<br />

C. Confrm that the boot disk confguraaon is as expected.<br />

D. Connect <strong>to</strong> the console from the ACTIVE SP.<br />

Aoswern D<br />

Explanaaonn<br />

Referencen<br />

htpsn//docs.oracle.com/cd/EE1972-2E/872-EE88-E7/core_ilom_appa.html<br />

Question 2<br />

A cus<strong>to</strong>mer has a newly installed <strong>SPARC</strong> <strong>M5</strong>-37 pla<strong>to</strong>rm. Afer using the HS processes, the SPs are now<br />

confgured on their network, <strong>and</strong> the cus<strong>to</strong>mer wants <strong>to</strong> confgure the PDomains. Which two opaons<br />

represent choices that the cus<strong>to</strong>mer has <strong>to</strong> set up the pla<strong>to</strong>rm out of the box?<br />

A. accessing a Solaris domain on another host <strong>and</strong> using ipmi <strong>to</strong>ol <strong>to</strong> assign components <strong>to</strong> PDomains<br />

B. using the <strong>Oracle</strong> ILOM BUI <strong>to</strong> assign components <strong>to</strong> PDomains<br />

C. using <strong>Oracle</strong> Ops Center <strong>to</strong> assign components <strong>to</strong> PDomains<br />

D. using the service processor ILOM comm<strong>and</strong>-line interface <strong>to</strong> assign components <strong>to</strong> PDomains<br />

Explanaaonn<br />

Referencen<br />

htpsn//docs.oracle.com/cd/E72355_2E/html/E2E7E2//222220E277785.html<br />

Question 3<br />

Aoswern B, D<br />

You are connecaon serial <strong>and</strong> network cables <strong>to</strong> two SPs located at the front of the server. Your cus<strong>to</strong>mer<br />

has requested that you set this up <strong>to</strong> enable E-GbE network speeds. Which acaon would you take?<br />

A. Connect 37 CAT6A cables from the SPO <strong>and</strong> SPE SER MGT RJ-25 ports <strong>to</strong> separate terminal devices.<br />

B. Connect Category 5 cables from the SPO <strong>and</strong> SPE SER MGT RJ-25 ports <strong>to</strong> separate terminal devices.<br />

C. Connect Category 7 cables from the SPO <strong>and</strong> SPE SER MGT RJ-25 ports <strong>to</strong> separate terminal devices.<br />

D. Connect Category 6 (or beterr cables <strong>and</strong> network devices that support E222BASE-T networks <strong>to</strong><br />

separate terminal devices<br />

Aoswern D


Explanaaonn<br />

Referencen<br />

htpsn//docs.oracle.com/cd/E72355_2E/html/E2E7E2//2222b9dE31<strong>32</strong>96.html<br />

Question 4<br />

When booang up a pre-installed domain, you are asked for some confguraaon informaaon. Where<br />

should you look for that informaaon?<br />

A. System Administraaon Guide<br />

B. Installaaon <strong>and</strong> Confguraaon Plan<br />

C. Installaaon Guide<br />

D. <strong>Server</strong> Product Notes<br />

Explanaaonn<br />

Referencen<br />

htpsn//www.debian.org/releases/stable/armel/install.txt.en<br />

Question 5<br />

Aoswern C<br />

During a site visit <strong>to</strong> a cus<strong>to</strong>mer who has three <strong>SPARC</strong> <strong>M5</strong>-37 pla<strong>to</strong>rms, which two acaons would you<br />

take <strong>to</strong> confrm each pla<strong>to</strong>rm serial number?<br />

A. Visually check for the chassis serial number label at the front lower lef – h<strong>and</strong> side.<br />

B. Using the SP on each pla<strong>to</strong>rm <strong>to</strong> access the ILOM, run show /system serial_ number.<br />

C. Visually check for the chassis serial number label at the front upper right-h<strong>and</strong> side.<br />

D. Using the SP on each pla<strong>to</strong>rm <strong>to</strong> access the ILOM, run show /systemsystem_ idenafcaaon.<br />

E. Visually check for the chassis serial number label at the rear, <strong>to</strong>wards the <strong>to</strong>p, in the middle.<br />

Explanaaonn<br />

Referencen<br />

htpsn//docs.oracle.com/cd/EE1723-2E/872-EE88-E7/core_ilom_overview.html<br />

Question 6<br />

Which three statements are correct about data paths in the <strong>SPARC</strong> <strong>M5</strong>-37 server?<br />

Aoswern B,D<br />

A. Within a DCU, a CPU talks <strong>to</strong> another CPU directly by using the coherency switch. <strong>The</strong> SSB is not<br />

needed.<br />

B. From one DCU <strong>to</strong> a diferent DCU, an even talks with only another even (same for oddr <strong>and</strong> hops <strong>to</strong><br />

the odd-numbered board, if needed, on the desanaaon DCU.<br />

C. From one DCU <strong>to</strong> a diferent DCU, all CPUs can access all PCIe slots In the desanaaon DCU directly in


one hop.<br />

D. A DCU can communicate data only with other DCUs via the BX ASICs on the SSB.<br />

E. From one DCU <strong>to</strong> a diferent DCU, even CPUs can access ail the odd PCIe slots in the desanaaon DCU<br />

directly in one hop.<br />

Explanaaonn<br />

Referencen<br />

htpn//docs.oracle.com/cd/BE252E_2E/server.172/a16533/statspac.htm<br />

Question 7<br />

Which statement is correct?<br />

Aoswern A,C,D<br />

A. <strong>The</strong> <strong>SPARC</strong> <strong>M5</strong>-37 processor has E6 cores, 28MB L3$; T5 processor ha E6 cores, 8MB L3$<br />

B. <strong>The</strong> <strong>SPARC</strong> <strong>M5</strong>-37 processor has 6 cores, 28MB L3$; T5 processor ha E6 cores, 8MB L3$<br />

C. <strong>The</strong> <strong>SPARC</strong> <strong>M5</strong>-37 processor has E6 cores, 72MB L3$; T5 processor ha E6 cores, 8MB L3$<br />

D. <strong>The</strong> <strong>SPARC</strong> <strong>M5</strong>-37 processor has 6 cores, 72MB L3$; T5 processor ha E6 cores, 28MB L3$<br />

Explanaaonn<br />

Referencen<br />

htpn//docs.oracle.com/cd/E72355_2E/html/E2E7E2//2222E33E31711E.html<br />

Question 8<br />

Aoswern B<br />

You power –on PDomain2 <strong>and</strong> noace that it does not go through POST, <strong>Exam</strong>ine the following outputn


In order for this <strong>to</strong> go through post, which property needs <strong>to</strong> be changed?<br />

A. level<br />

B. mode<br />

C. power_on_level<br />

D. error_reset_level<br />

Aoswern C<br />

Question 9<br />

Which three statements are true about the newest clock board redesign/ operaaon in a <strong>SPARC</strong> <strong>M5</strong>-<br />

37/<strong>M6</strong>-37 server?<br />

A. <strong>The</strong>re are two clock boards in a redundant confguraaon, so the failure of the primary clock board<br />

does not cause a reboot of the server.<br />

B. <strong>The</strong>re are two clock boards. Each has two clock sources, so if a clock source fails, the alternate clock<br />

source on the same board takes over.<br />

C. While the system is running on an acave clock board, a faulty clock board can be replaceddynamically.<br />

D. <strong>The</strong>re are two clock boards in a redundant confguraaon, <strong>and</strong> there is a dynamic failover of theprimary<br />

clock board <strong>to</strong> the st<strong>and</strong>by clock board.<br />

Question 10<br />

Which three statements are correct about installing DIMMS?<br />

Aoswern A,B,D


A. Be sure that you are properly grounded before inserang the DIMM(sr in the socket(sr.<br />

B. If a DIMM slot LED is lit, press the Fault Remind bu<strong>to</strong>n <strong>to</strong> turn of the LED.<br />

C. When replacing a faulty CMU, you do not need <strong>to</strong> keep DIMMs in the same locaaons on<br />

thereplacement CMU, because the server has an intelligent load-balance feature.<br />

D. When you press the DIMM Fault Remind bu<strong>to</strong>n, the slot for a faulty DIMM is lit.<br />

E. If a DIMM slot LED is lit, the fault is cleared only by the reset comm<strong>and</strong> In JLOM.<br />

Aoswern B,C,D


Thank You For Trying Free <strong>1Z0</strong>-<strong>489</strong> PDF<br />

Demo<br />

Get Updated <strong>1Z0</strong>-<strong>489</strong> <strong>Exam</strong><br />

Questions Answers PDF<br />

Visit Link Below<br />

https://dumpsarchive.com/dumps/<strong>1Z0</strong>-<strong>489</strong>/<br />

Start Your <strong>1Z0</strong>-<strong>489</strong> Preparation

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!