Motor power<br />

Chimney diameter<br />

Number of fan blades<br />

Depending on the amount of fluid flow<br />

Pipe diameters (pressure dependent on diameter)<br />

Number and type of nozzles to be used<br />

Filler air velocity<br />

Filler unit water load<br />

are reached.<br />

There are many issues to be considered in design.<br />

For example: water distribution system should be selected correctly according to <strong>tower</strong> inlet and<br />

outlet temperatures.<br />

If the Pvc-u or PPrc (copolymer-added PP) materials are not selected at the correct temperature,<br />

breaks will occur due to softening the pipe or too much hardness.<br />

Another issue in water distribution systems is the choice of pipe with appropriate pressure durability.<br />

<strong>GRP</strong> (glass fiber reinforced polyester) stands out in the selection of polyester which is the building<br />

stone of the material. The use of orthophthalic polyester is more important in the selection of<br />

isophthalic polyester at higher temperatures.<br />

If there is acidic basic density in the system, vinil polyester should be preferred.<br />

The choices made by considering the design values are as important as the least complex design<br />

calculations.<br />

If, for example, the "fill air speed" is too high, unnecessary water exits will be observed in the form of<br />

rain from the end of the water transport. This is definitely an unwanted condition and will cause<br />

leakage by increasing water consumption.<br />

Or, if it is below normal, insufficient heat transfer will not be used in efficiency where the resulting<br />

<strong>tower</strong> can be used.<br />

Another example can be given for the "rain water density" (rain density). Sometimes the <strong>tower</strong> flow<br />

is quite high and the design of the <strong>tower</strong> is very small when the temperature difference (delta t) is<br />

low.<br />

In the case of overheating, the heat transfer between air and water is not efficient. In theory, it can<br />

not be realized due to the fact that the heat transfer unit which is envisaged to be easily made has a