Water cooling tower GRP cooling tower ctp engineer
Water cooling tower GRP cooling tower ctp engineer https://www.susogutmakulesi.com.tr https://www.susogutmakuleleri.com https://ctpmuhendislik.com http://www.grpcoolingtower.com https://www.odaksan.com
Water cooling tower GRP cooling tower ctp engineer
https://www.susogutmakulesi.com.tr
https://www.susogutmakuleleri.com
https://ctpmuhendislik.com
http://www.grpcoolingtower.com
https://www.odaksan.com
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Motor power<br />
Chimney diameter<br />
Number of fan blades<br />
Depending on the amount of fluid flow<br />
Pipe diameters (pressure dependent on diameter)<br />
Number and type of nozzles to be used<br />
Filler air velocity<br />
Filler unit water load<br />
are reached.<br />
There are many issues to be considered in design.<br />
For example: water distribution system should be selected correctly according to <strong>tower</strong> inlet and<br />
outlet temperatures.<br />
If the Pvc-u or PPrc (copolymer-added PP) materials are not selected at the correct temperature,<br />
breaks will occur due to softening the pipe or too much hardness.<br />
Another issue in water distribution systems is the choice of pipe with appropriate pressure durability.<br />
<strong>GRP</strong> (glass fiber reinforced polyester) stands out in the selection of polyester which is the building<br />
stone of the material. The use of orthophthalic polyester is more important in the selection of<br />
isophthalic polyester at higher temperatures.<br />
If there is acidic basic density in the system, vinil polyester should be preferred.<br />
The choices made by considering the design values are as important as the least complex design<br />
calculations.<br />
If, for example, the "fill air speed" is too high, unnecessary water exits will be observed in the form of<br />
rain from the end of the water transport. This is definitely an unwanted condition and will cause<br />
leakage by increasing water consumption.<br />
Or, if it is below normal, insufficient heat transfer will not be used in efficiency where the resulting<br />
<strong>tower</strong> can be used.<br />
Another example can be given for the "rain water density" (rain density). Sometimes the <strong>tower</strong> flow<br />
is quite high and the design of the <strong>tower</strong> is very small when the temperature difference (delta t) is<br />
low.<br />
In the case of overheating, the heat transfer between air and water is not efficient. In theory, it can<br />
not be realized due to the fact that the heat transfer unit which is envisaged to be easily made has a