2) Loosen the copy lamp unit wire fixing screw.<br />

4) Loosen the set screw of the scanner drive pulley which is not in<br />

contact with No. 2/3 mirror base unit positioning plate.<br />

5) Without moving the scanner drive pulley shaft, manually turn the<br />

scanner drive pulley until the positioning plate is brought into contact<br />

with No. 2/3 mirror base unit, then fix the scanner drive pulley.<br />

Wire fixing screw<br />

3) Manually turn the mirror base drive pulley and bring No. 2/3 mirror<br />

base unit into contact with the positioning plate. At that time, if the<br />

front frame side and the re<strong>ar</strong> frame side of No. 2/3 mirror base unit<br />

<strong>ar</strong>e brought into contact with the positioning plate at the same time,<br />

the mirror base unit p<strong>ar</strong>allelism is proper. If one of them is in contact<br />

with the positioning plate, perform the adjustment of 4).<br />

6) Put No. 2/3 mirror base unit on the positioning plate again, push the<br />

projections on the front frame side and the re<strong>ar</strong> frame side of the<br />

copy lamp unit to the corner frame, and tighten the wire fixing screw.<br />

AR-<strong>5618</strong>S ADJUSTMENT 6-5