44 01 Toner density control Enable/<br />

Disable (ON/OFF) setting<br />

Details of operation<br />

Setting is made whether the toner density control is performed or not.<br />

When this simulation is executed, the current code number is displayed on the 7-seg display. (1=ON<br />

[Enable], 0=OFF [Disable])<br />

Enter a code number and press [START] key, and the setting is settled and saved into the EEPROM<br />

and the machine goes into the sub code input standby mode.<br />

Switching can be made with [AUTO/TEXT/PHOTO] key, and the set value of the selected mode is<br />

displayed on the copy quantity display section.<br />

The entered value at that time is written into the EEPROM.<br />

LED Setting mode Default<br />

AUTO indicator<br />

TEXT indicator<br />

AUTO indicator & PHOTO indicator<br />

TEXT indicator & PHOTO indicator<br />

AUTO indicator & TEXT indicator &<br />

PHOTO indicator<br />

Print ration correction<br />

Life correction<br />

Drip infusion<br />

Purge process<br />

Unconditional toner supply<br />

1<br />

18/20cpm machine: 0<br />

23cpm machine:1<br />

0<br />

0<br />

1<br />

<br />

Print ratio correction<br />

In this correction, the toner supply interval is determined according to the print ratio, and an<br />

overtoner is prevented.<br />

Life correction<br />

When the life of any consumable p<strong>ar</strong>t approached the end, this correction prevents against<br />

undertoner.<br />

Note for items m<strong>ar</strong>ked with<br />

Drip infusion and Purge process <strong>ar</strong>e simulations for analysis, and do not set them to "Enable=1" in<br />

the m<strong>ar</strong>ket.<br />

If these items <strong>ar</strong>e set to "Enable=1", the toner density rises or falls extremely, resulting in developer<br />

fall and toner dispersion.<br />

If they <strong>ar</strong>e set to "Enable=1", developer must be replaced and the machine inside and the process<br />

unit must be cleaned.<br />

16 Toner density control data check<br />

and toner density control<br />

correction amount display<br />

Unconditional toner supply<br />

When the DV unit and the drum unit run idle, a small quantity of toner is consumed. To supply this<br />

consumption, toner is supplied according to the rotation time of the DV unit.<br />

The output value of the ATC sensor is checked and the toner density control correction value is<br />

displayed on the 7-seg display.<br />

The display mode can be switched by pressing [AUTO/TEXT/PHOTO] key.<br />

When [Interrupt] key is pressed, the machine goes into the sub code input standby mode. When [CA]<br />

key is pressed, the machine goes out of the simulation mode.<br />

LED<br />

AUTO indicator<br />

TEXT indicator<br />

Display content<br />

The current output value of the ATC sensor is displayed.<br />

The correction value according to the progress of life is added to the<br />

current output value of the ATC sensor and the sum is displayed.<br />

34 Transfer current setting Used to set the transfer current for the front surface and that for the back surface. When this<br />

simulation is executed, the current set value is displayed on the 7-seg display. Select the set value<br />

with the zoom [Zoom] keys and press the [START] key, and the set content is written into the<br />

EEPROM and the machine goes into the sub code input standby mode. Press the [AUTO/TEXT/<br />

PHOTO] key to select each setting mode. At that time, the setup content is written into the EEPROM.<br />

The set range is 90uA ~ 360uA in the increment of 10uA.<br />

LED<br />

AUTO indicator<br />

TEXT indicator<br />

AUTO indicator & PHOTO indicator<br />

TEXT indicator & PHOTO indicator<br />

AUTO & TEXT & PHOTO indicator<br />

* Small size paper must be Letter R (A4R) or smaller.<br />

* For the special size of tray, use the normal size width.<br />

Setting mode<br />

Normal size width: Front<br />

Normal size width: Back(Duplex model only)<br />

Small size width: Front<br />

Small size width: Back(Duplex model only)<br />

Bypass tray<br />

AR-<strong>5618</strong>S SIMULATIONS 7-14

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!