Preparing the Installation

1.3 Installation Considerations

Inverters are composed of various precision, electronic devices, and therefore the

installation environment can significantly impact the lifespan and reliability of the product.

The table below details the ideal operation and installation conditions for the inverter.

Items

Ambient Temperature*

Ambient Humidity

Description

-10 ℃–50 ℃ (40 ℃ and above, 2.5% / ℃ Current Derating

search. 50 ℃ 75% of the rated current of the drive if possible)

95% relative humidity (no condensation)

Storage Temperature - 4–149 F (-20–65 ℃)

Environmental Factors

Altitude

An environment free from corrosive or flammable gases, oil residue

or dust

Maximum 3,280 ft (1,000m) above sea level for standard operation.

After that the driver rated voltage and the rated output current

derating by 1% for every extra 328 ft (100m) up to 13,123 ft

(4,000m).

Vibration less than 1.0 G (9.8m/sec 2 )

Air Pressure

70 –106 kPa

* The ambient temperature is the temperature measured at a point 2” (5 cm) from the

surface of the inverter.

Do not allow the ambient temperature to exceed the allowable range while operating the

inverter.