<strong>SAG582140000</strong> System Application Guide<br />
Issue AL, April 12, 2010 Spec. No. 582140000 (Model 802NLDB, 802NLEB, 802NL-B)<br />
Restrictions<br />
For use with List 30 or List 31 manufactured after 12/01/04 only.<br />
See Surge Protection in the SPECIFICATION section for additional ratings.<br />
Ordering Notes<br />
1) Order if additional surge suppression is required.<br />
2) A wire harness is factory connected to Form-C relay contacts located on each surge suppression<br />
assembly for remote monitoring. Connect the wire harness to the first two binary inputs on an MCA I/O<br />
circuit card (separately ordered – See List 71). The MCA then provides alarm display messages and an<br />
audible alarm when a surge suppression assembly activates. Order a List 71 MCA I/O Circuit Card as<br />
required to provide MCA binary inputs for the surge suppression alarms.<br />
3) Note that two (2) MCA customer alarm relay circuit cards are provided with the primary bay. If remote<br />
surge suppression alarm relay contacts are required and you expect to use the alarm relays on the<br />
factory provided cards for other uses, order a List 70 MCA relay circuit card as required.<br />
List 36: Surge Suppression for 208VAC Input PDSC<br />
Features<br />
♦ Provides two (2) surge suppression assemblies for the PDSC. One wired to Rectifier AC input circuit<br />
breakers CB1, CB3, CB5, CB7, and CB9. The other to CB2, CB4, CB6, CB8, and CB10.<br />
♦ 100kA interrupting capacity.<br />
♦ Overcurrent fusing and thermal protection.<br />
Restrictions<br />
For use with List 32 only.<br />
See Surge Protection in the SPECIFICATION section for additional ratings.<br />
Ordering Notes<br />
1) Order if additional surge suppression is required.<br />
2) A wire harness is factory connected to Form-C relay contacts located on each surge suppression<br />
assembly for remote monitoring. Connect the wire harness to the first two binary inputs on an MCA I/O<br />
circuit card (separately ordered – See List 71). The MCA then provides alarm display messages and an<br />
audible alarm when a surge suppression assembly activates. Order a List 71 MCA I/O Circuit Card as<br />
required to provide MCA binary inputs for the surge suppression alarms.<br />
3) Note that two (2) MCA customer alarm relay circuit cards are provided with the primary bay. If remote<br />
surge suppression alarm relay contacts are required and you expect to use the alarm relays on the<br />
factory provided cards for other uses, order a List 70 MCA relay circuit card as required.<br />
List 50: Optional LMS Main CPU Circuit Card (Primary <strong>Power</strong>/Distribution Bay)<br />
Features<br />
♦ Provides the LMS Monitoring System.<br />
♦ Refer to SAG586505000 for further information.<br />
Restrictions<br />
The LMS Monitoring System Main CPU circuit card is mounted in the Primary <strong>Power</strong>/Distribution Bay only.<br />