AIRCOMATIC® III<br />

WITH OZONE FUNCTION<br />

ESPECIALLY<br />

FOR VEHICLES<br />

OZONE NOTIFICATION:<br />

Ozone is a powerful oxidising agent which is harmful and even lethal to humans in high doses. Ozone<br />

can react explosively with oil and grease, and even low concentrations of ozone can have a significant<br />

effect upon textiles, fabrics, colour fastness of material, organic dyes, electrical wiring, metals, rubber,<br />

plastics, polymers and paints and cause the characteristic<br />

.<br />

cracking of stressed rubber, commonly called<br />

‘weathering’. Ozone oxidises organic matter and inhibits the growth of bacteria (although it does not<br />

kill it).<br />

The Wynn’s <strong>Aircomatic</strong>® III has been specifically designed for the automotive industry to<br />

deliver safe but effective levels of ozone for odour removal from vehicle interiors and<br />

without risk to the technician or materials in the vehicle cabin.<br />

Wynn’s <strong>Aircomatic</strong>® delivers 20mg per hour of ozone which<br />

equates to 2-4 parts per million (ppm). As an additional safety<br />

measure, Wynn’s <strong>Aircomatic</strong>® III will not operate in ozone<br />

mode until a bottle of Air Purifier treatment is added to the<br />

machine.<br />

The Air Purifier liquid will be nebulised into the vehicle after<br />

the ozone treatment is completed to enhance the odour<br />

removal, but most importantly to neutralise any remaining<br />

ozone ensuring complete safety for technicians and drivers.<br />

Wynn’s ozone & Air Purifier treatment:<br />

• Max. concentration of ozone during treatment : 2ppm<br />

• Max. concentration of ozone after treatment & 15 minutes of ventilation : 0.82ppm<br />

• Max. concentration after ozone treatment & Air Purifier treatment : 0.007ppm<br />

After a Wynn’s <strong>Aircomatic</strong>® III ozone & Air Purifier treatment the vehicle can immediately be<br />

entered and driven away.<br />

Wynn’s <strong>Aircomatic</strong>® III vs. high-powered Commercial Ozone Generators<br />

Machines producing up to 20g of ozone per hour are now being recommended for automotive use. We<br />

strongly advise against the use of these machines in vehicle interiors as they deliver potentially lethal<br />

levels of ozone and may cause serious damage to the materials in a vehicle cabin.<br />

Subject Wynn’s <strong>Aircomatic</strong>® III Commercial Ozone Generators<br />

Produces safe levels of ozone ü ×<br />

Safe for all vehicle materials ü ×<br />

Vehicle immediately ready for use<br />

after treatment<br />

ü ×<br />

Delivering effective and safe products


Clean and disinfect<br />

your air conditioning system<br />

Protect from the<br />

spread of viruses<br />

and bacteria<br />

in your car<br />

EN14476 test results<br />

virus<br />

elimination<br />

MINUTES<br />

15 IN<br />

INCluding SARS‐CoV‐2 (Covid-19)<br />

Use Wynn’s <strong>Aircomatic</strong>® solutions<br />

A LEADER IN AIRCO TREATMENTS


How can viruses enter the<br />

air conditioning system?<br />

The air conditioning filter, evaporator and air vents<br />

are places where microorganisms have ideal<br />

conditions to grow (low temperature and darkness)<br />

How can we prevent<br />

them from entering<br />

the passenger cabin?<br />

➜ BY CLEANING & DISINFECTING THE ENTIRE AIR CONDITIONING SYSTEM<br />

Also cleans the filter<br />

Why Clean?<br />

• Clean systems inhibit bacterial growth<br />

• Cleaning physically removes dirt, grime and accompanying<br />

germs leaving poor conditions for bacterial growth<br />

Why Disinfect?<br />

• To eliminate most germs like bacteria, fungi, algae and to<br />

prevent growth of microrganisms and viruses<br />

• Disinfected systems are protected up to 6 months from<br />

bacteria re-growth (NEN 6265 test)<br />

How?<br />

• Nebulisation process guarantees contact with all the<br />

components of the air conditioning system (including the<br />

filter and the evaporator)<br />

• <strong>Aircomatic</strong> treatments have a cleaning effect on systems<br />

and physically remove microorganisms on systems<br />

Bacteria<br />

In-vehicle testing<br />

A/C<br />

Untreated<br />

A/C<br />

Treated<br />

A/C<br />

Untreated<br />

A/C<br />

Treated<br />

What other benefits can we<br />

gain from disinfecting?<br />

In addition, by using <strong>Aircomatic</strong> with the Ozonizer and Air Purifier,<br />

you will further clean the surfaces of the interior of the car<br />

<strong>Aircomatic</strong>® III<br />

PN. 68480<br />

Airco-Clean® - 100 ml<br />

PN. 30205<br />

• Reduction of bad smells is immediately noticeable due to<br />

inactivity of germs (bacteria and fungi)<br />

• Helps to prevent infections and allergic reactions by cleaning<br />

• Excellent sanitising treatment to avoid future infections<br />

Air Purifier® - 60 ml<br />

PN. 31705<br />

Use biocides safely. Always read the label and product information before use. For further information visit www.wynns.com


<strong>Aircomatic</strong>®III Operating Instructions<br />

Treatment with ozone and Air Purifier<br />

Max. 40 minutes — no dismantling<br />

1 2 2a 2b<br />

Fill 1 bottle of 60 ml Wynn’s Air<br />

Purifier in the machine.<br />

Put the machine horizontally<br />

upright on a convenient place<br />

in the middle of the car interior.<br />

Alternatively you can put the<br />

machine: on the floor at the<br />

passenger side,<br />

on the floor between front and<br />

rear seat,<br />

2c 3 4 5<br />

in the trunk. Connect the power plug to a 12<br />

V DC connection in the car<br />

(cigarette lighter or other)<br />

Set treatment level of ozone<br />

generation, by pushing O 3<br />

button. Each push on this<br />

button will select the next<br />

treatment level.<br />

No LED lighted = 0 position. No<br />

ozone treatment. This position<br />

is chosen for average smell<br />

problems.<br />

5a 5b 5c 6<br />

LED lighted on ‘Low’ position.<br />

Ozone treatment 15 min. This<br />

position is chosen for strong<br />

smell problems.<br />

LED lighted on ‘High’ position.<br />

Ozone treatment 30 min. This<br />

position is chosen for severe<br />

smell problems.<br />

If the LED light is in ‘High’<br />

position and the O 3<br />

button is<br />

pushed, it moves to 0 position.<br />

Connect the outlet tube and<br />

position it, so that it is not too<br />

close to a surface or directed<br />

towards a window.<br />

7 8 9 10<br />

Push the start button<br />

Before ozone treatment starts<br />

the LED lights will flash<br />

alternating between ‘Low’ and<br />

‘High’.<br />

Get out of the vehicle and close<br />

the doors. The ozone treatment<br />

starts after a short period. This<br />

gives you enough time to leave<br />

the car.<br />

Once the ozone treatment<br />

starts the LED lights will cycle<br />

through, reducing with the<br />

timer. (No vapour is visible.)<br />

11 12 13 14<br />

After the ozone generation has<br />

finished, the Air Purifier<br />

vaporization will automatically<br />

start.<br />

The machine automatically<br />

switches off • At the end of the<br />

treatment time • At minimum<br />

fluid level.<br />

Open 2 opposite doors and<br />

leave open for about 5<br />

minutes.<br />

Disconnect power source and<br />

dispose of residue.<br />

15 16 17<br />

®<br />

®<br />

Rinse the machine with a little<br />

water (max. 100ml).<br />

Empty machine.<br />

Put cap back on filling opening.


<strong>Aircomatic</strong>®III Operating Instructions<br />

Treatment with Airco-Clean ® Ultrasonic for Cars<br />

20 minutes — no dismantling<br />

1 2 3<br />

Fill 1 bottle of 100 ml Wynn’s Airco-Clean®<br />

ultrasonic for cars in the machine.<br />

Put the machine horizontally upright on<br />

the floor at the passenger side.<br />

Connect the power plug to a 12 V DC<br />

connection in the car (cigarette lighter or<br />

other).<br />

4 5 6<br />

Start engine.<br />

Set internal temperature to 22°C.<br />

Set fan at lowest speed.<br />

7 8 9<br />

Set air flow to the centre dashboard vents<br />

only.<br />

Set ventilation to "recirculate".<br />

Connect the outlet tube and position it in<br />

the air inlet opening.<br />

10 11 12<br />

Push the ‘START’ button.<br />

Get out of the vehicle and close doors.<br />

The machine automatically switches off •<br />

At the end of the treatment time • At<br />

minimum fluid level.<br />

13 14 15<br />

Open 2 opposite doors and leave open for<br />

about 5 minutes.<br />

Disconnect power source and dispose of<br />

residue.<br />

Rinse the machine with a little water (max.<br />

100ml).<br />

16 17<br />

Empty machine.<br />

Put cap back on filling opening.<br />

A LEADER IN AIRCO TREATMENTS<br />

®<br />

®