Improving life through heat transfer solutions
TANKS & VESSELS
WATER TREATMENT
BOILER SEQUENCING
A steam boiler is just one part of an
often complex and well engineered
steam system that requires the correct
ancillary equipment to ensure process
uptime and system longevity.
TANKS & VESSELS
www.fulton.co.uk
WATER TREATMENT
sales@fulton.co.uk
THE OPTIMUM DELIVERY OF FEEDWATER, COLLECTION OF CONDENSATE
AND BLOWDOWN OF A BOILER IS ESSENTIAL TO THE CORRECT
OPERATION OF A STEAM SYSTEM.
IT IS ESSENTIAL THAT PROPER WATER TREATMENT BE IMPLEMENTED AS
PART OF THE DESIGN TO MINIMISE CORROSION AND DEPOSITION,
IMPROVE EFFICIENCY AND PROLONG THE LIFE OF THE BOILER.
INJECTION SYSTEMS WATER LEVEL CONTROLS OPTIONAL EQUIPMENT
For systems with little or no condensate
return, a self-acting steam heating
system is supplied.
This reduces dissolved oxygen and the
possibility of thermal shock.
A comprehensive level control system is
supplied with all feedwater tanks,
to maintain a predetermined water
level and minimum flow rate for water
softeners.
All feed water tanks are configured to
site-specific condition in relation to
process demand and condensate return.
Water level controls, steam injection
systems, atmospheric deaerator heads
and tank insulation jackets are optional
and can be supplied to complement
your system.
According to HSE INDG-436
and BG04, a steam boiler’s
feedwater must meet the
manufacturer’s guidelines.
BLOWDOWN VESSELS WATER SOFTENING FEEDWATER SAMPLING CHEMICAL DOSAGE
Designed to reduce the pressure of
the blowdown discharge from the
boiler to atmospheric pressure,
blowdown vessels also reduce the
blowdown discharge to drain to
acceptable temperatures for
compliance to water by-laws (a water
cooling system may need to be fitted).
Fulton’s blowdown vessels are
designed and built to BS EN 13445 and
comply with BG03; and available
in three sizes from 15 to 210 litres.
The most common form of water
pre-treatment is water softening.
The treated water contains only
non-hardness forming salts.
The Fulton Duplex range of water
softeners are fully rechargeable and
using the two vessel system can supply
constant, uninterrupted, treated
feedwater to the boiler.
In order to ensure the safe, efficient and
economical running of a boiler plant, it
is imperative that the boiler feedwater is
sampled for analysis at regular intervals.
The Fulton water sample cooler has
been designed to facilitate the
monitoring of the boiler water to be
taken from the boiler in a safe manner.
The Sample Cooler cools the boiler water
to an appropriate temperature for safe
handling and accurate analysis.
Impurities within boiler feedwater
can cause problems with the
efficiency of steam boilers and steam
systems. It is usually necessary to
chemically treat feedwater to remove
or modify impurities.
Fulton’s chemical dosing sets dose
chemicals into either the condensate
return/feedwater tank or boiler
feedwater line.
BOILER SEQUENCING
www.fulton.co.uk
FOR STEAM SYSTEMS USING MULTIPLE BOILERS, BOILER SEQUENCING
SAVES ENERGY AND COSTS BY REGULATING HOW EACH OPERATES TO
MATCH STEAM LOAD REQUIREMENTS.
PRECISE CONTROL
SCOPE is Fulton’s own intelligent boiler
sequencing system that provides redundancy
and reliability to offer significant savings by
automating start-up and shut-down
procedures, controlling and optimising main
steam header pressure or temperature,
ensuring steam supply is controlled
precisely for the required process.
AFTERCARE
Your company depends on its heat transfer equipment to get the job
done, every day. So when you need start-up, repair/maintenance or
aftermarket parts, it’s essential that you call on the professionals that
understand the capabilities of your equipment and complex nature of
your business.
Fulton’s aftercare portfolio includes:
• commissioning • spares supply • emergency response
• boiler upgrades • maintenance and annual service contracts
• accredited boiler operator and water treatment training
• water treatment services • technical boiler house risk assessments
Want to know more? Email aftercare@fulton.co.uk.
5 Fernhurst Road,
Fishponds,
Bristol,
BS5 7FG, UK.
T: +44 (0)117 972 3322
F: +44 (0)117 972 3358
W: www.fulton.co.uk
E: sales@fulton.co.uk
ANCILLARIES-BROCHURE-4