Improving life through heat transfer solutions

TANKS & VESSELS

WATER TREATMENT

BOILER SEQUENCING

A steam boiler is just one part of an

often complex and well engineered

steam system that requires the correct

ancillary equipment to ensure process

uptime and system longevity.


TANKS & VESSELS

www.fulton.co.uk

WATER TREATMENT

sales@fulton.co.uk

THE OPTIMUM DELIVERY OF FEEDWATER, COLLECTION OF CONDENSATE

AND BLOWDOWN OF A BOILER IS ESSENTIAL TO THE CORRECT

OPERATION OF A STEAM SYSTEM.

IT IS ESSENTIAL THAT PROPER WATER TREATMENT BE IMPLEMENTED AS

PART OF THE DESIGN TO MINIMISE CORROSION AND DEPOSITION,

IMPROVE EFFICIENCY AND PROLONG THE LIFE OF THE BOILER.

INJECTION SYSTEMS WATER LEVEL CONTROLS OPTIONAL EQUIPMENT

For systems with little or no condensate

return, a self-acting steam heating

system is supplied.

This reduces dissolved oxygen and the

possibility of thermal shock.

A comprehensive level control system is

supplied with all feedwater tanks,

to maintain a predetermined water

level and minimum flow rate for water

softeners.

All feed water tanks are configured to

site-specific condition in relation to

process demand and condensate return.

Water level controls, steam injection

systems, atmospheric deaerator heads

and tank insulation jackets are optional

and can be supplied to complement

your system.

According to HSE INDG-436

and BG04, a steam boiler’s

feedwater must meet the

manufacturer’s guidelines.

BLOWDOWN VESSELS WATER SOFTENING FEEDWATER SAMPLING CHEMICAL DOSAGE

Designed to reduce the pressure of

the blowdown discharge from the

boiler to atmospheric pressure,

blowdown vessels also reduce the

blowdown discharge to drain to

acceptable temperatures for

compliance to water by-laws (a water

cooling system may need to be fitted).

Fulton’s blowdown vessels are

designed and built to BS EN 13445 and

comply with BG03; and available

in three sizes from 15 to 210 litres.

The most common form of water

pre-treatment is water softening.

The treated water contains only

non-hardness forming salts.

The Fulton Duplex range of water

softeners are fully rechargeable and

using the two vessel system can supply

constant, uninterrupted, treated

feedwater to the boiler.

In order to ensure the safe, efficient and

economical running of a boiler plant, it

is imperative that the boiler feedwater is

sampled for analysis at regular intervals.

The Fulton water sample cooler has

been designed to facilitate the

monitoring of the boiler water to be

taken from the boiler in a safe manner.

The Sample Cooler cools the boiler water

to an appropriate temperature for safe

handling and accurate analysis.

Impurities within boiler feedwater

can cause problems with the

efficiency of steam boilers and steam

systems. It is usually necessary to

chemically treat feedwater to remove

or modify impurities.

Fulton’s chemical dosing sets dose

chemicals into either the condensate

return/feedwater tank or boiler

feedwater line.



BOILER SEQUENCING

www.fulton.co.uk

FOR STEAM SYSTEMS USING MULTIPLE BOILERS, BOILER SEQUENCING

SAVES ENERGY AND COSTS BY REGULATING HOW EACH OPERATES TO

MATCH STEAM LOAD REQUIREMENTS.

PRECISE CONTROL

SCOPE is Fulton’s own intelligent boiler

sequencing system that provides redundancy

and reliability to offer significant savings by

automating start-up and shut-down

procedures, controlling and optimising main

steam header pressure or temperature,

ensuring steam supply is controlled

precisely for the required process.

AFTERCARE

Your company depends on its heat transfer equipment to get the job

done, every day. So when you need start-up, repair/maintenance or

aftermarket parts, it’s essential that you call on the professionals that

understand the capabilities of your equipment and complex nature of

your business.

Fulton’s aftercare portfolio includes:

• commissioning • spares supply • emergency response

• boiler upgrades • maintenance and annual service contracts

• accredited boiler operator and water treatment training

• water treatment services • technical boiler house risk assessments

Want to know more? Email aftercare@fulton.co.uk.

5 Fernhurst Road,

Fishponds,

Bristol,

BS5 7FG, UK.

T: +44 (0)117 972 3322

F: +44 (0)117 972 3358

W: www.fulton.co.uk

E: sales@fulton.co.uk

ANCILLARIES-BROCHURE-4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!