You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
K/KL Series: RIGHT ANGLE — Solid Shaft/Hollow Output<br />
K Series Lubrication Maintenance<br />
K102 thru K403 are supplied without breathers and are lubricated<br />
for life and maintenance free.<br />
Breathers are provided on K513 thru K1014, located as shown*.<br />
STOBER recommends changing the lubrication in breather supplied<br />
units after 10,000 hours for normal operating conditions or every<br />
1<br />
2<br />
3<br />
3 Stage Units<br />
(K513 thru K1013)<br />
1<br />
2<br />
4<br />
3<br />
4 Stage Units<br />
(K514 thru K1014)<br />
5,000 hours for wet operating conditions.<br />
*K513 and larger units with the Food & Corrosion Resistant option can<br />
exclude a breather. Contact STOBER for details.<br />
Drain Plug and Vent Location<br />
Mounting Position 1 2 * 2a * 3 4<br />
EL1 Vent Drain<br />
EL2 Drain Vent<br />
EL3 Vent Drain<br />
EL4 Drain Vent<br />
EL5<br />
K513-K1013 Drain Vent<br />
K514-K1014 Drain Vent<br />
EL6<br />
K513-K1013 Vent Drain<br />
K514-K1014 Vent Drain<br />
* Position 2a is on the opposite side of 2.<br />
38 <strong>MGS</strong> ® <strong>Speed</strong> <strong>Reducers</strong> V.29<br />
800.711.3588 • www.stober.com