KNAUER manufactures high-end scientific instruments for research, routine analysis, quality assurance, and other applications. Supported technologies include liquid chromatography, precise handling and pumping of liquids up to high pressures, as well as flow-through detection of dissolved substances. Customizable products and solutions are one of our strengths. Made in Germany. Developing devices that help people in the laboratory to gain new insights or facilitate their work. This is the spirit in which KNAUER was founded and continues to drive the company today.

KNAUER manufactures high-end scientific instruments for research, routine analysis, quality assurance, and other applications. Supported technologies include liquid chromatography, precise handling and pumping of liquids up to high pressures, as well as flow-through detection of dissolved substances. Customizable products and solutions are one of our strengths. Made in Germany.

Developing devices that help people in the laboratory to gain new insights or facilitate their work. This is the spirit in which KNAUER was founded and continues to drive the company today.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Standards for Performance Verification (PV)<br />

A PV procedure is recommended for testing newly installed AZURA® systems as well as for<br />

regularly monitoring the system performance.<br />

This table gives an overview of the needed PV document, PV standard and separation column for<br />

a specific AZURA® system.<br />

Backpressure<br />

range<br />

Type of<br />

detection<br />

Flow cell<br />

path length<br />

[mm]<br />

Injection:<br />

Sample loop<br />

volume [μl]<br />

PV document<br />

Article no. of PV<br />

standard<br />

Article no.<br />

of HPLC<br />

column<br />

UHPLC systems<br />

(max. 1000 bar)<br />

HPLC Plus systems<br />

(max. 862 bar)<br />

UV, DAD 10 1 – 20 VPV-001: Analytical HPLC,<br />

UV detection<br />

UV, DAD 10 21 – 100 VPV-001: Analytical HPLC,<br />

UV detection<br />

UV, DAD 50 1 – 20 VPV-001: Analytical HPLC,<br />

UV detection<br />

UV, DAD 50 21 – 100 VPV-001: Analytical HPLC,<br />

UV detection<br />

FLD all 1 – 20 VPV-004: Analytical HPLC,<br />

FL detection<br />

FLD all 21 – 100 VPV-004: Analytical HPLC,<br />

FL detection<br />

RID all all VPV-002: Analytical HPLC,<br />

RI detection<br />

UV, DAD 10 1 – 20 VPV-001: Analytical HPLC,<br />

UV detection<br />

UV, DAD 10 21 – 100 VPV-001: Analytical HPLC,<br />

UV detection<br />

UV, DAD 50 1 – 20 VPV-001: Analytical HPLC,<br />

UV detection<br />

UV, DAD 50 21 – 100 VPV-001: Analytical HPLC,<br />

UV detection<br />

FLD all 1 – 20 VPV-004: Analytical HPLC,<br />

FL detection<br />

FLD all 21 – 100 VPV-004: Analytical HPLC,<br />

FL detection<br />

RID all all VPV-002: Analytical HPLC,<br />

RI detection<br />

A01260-3 10BE181E2F<br />

A01260-2 10BE181E2F<br />

A01260-2 10BE181E2F<br />

A01260-1 10BE181E2F<br />

A01262-2 10BE181E2F<br />

A01262-3 10BE181E2F<br />

A01261-1 05WE184E2J<br />

A01260-4 15WE181E2J<br />

A01260-3 15WE181E2J<br />

A01260-3 15WE181E2J<br />

A01260-2 15WE181E2J<br />

A01262-1 15WE181E2J<br />

A01262-2 15WE181E2J<br />

A01261-1 05WE184E2J<br />

ECD in PAD<br />

mode<br />

n/a 20, 100 VPV-106: AZURA systems<br />

with ECD<br />

A01132<br />

n/a<br />

ECD in DC<br />

mode<br />

n/a 20, 100 VPV-106: AZURA systems<br />

with ECD<br />

A01273-2<br />

A01273-3<br />

n/a<br />

UV (normal<br />

phase)<br />

10, 50 10, 20, 100 VPV-009: AZURA HPLC<br />

systems in normal phase<br />

mode<br />

n/a<br />

15WE000E2J<br />

RID (normal<br />

phase)<br />

all all VPV-009: AZURA HPLC<br />

systems in normal phase<br />

mode<br />

n/a<br />

15WE000E2J<br />

Preparative HPLC<br />

systems<br />

UV, DAD ≤ 2 all VPV-007: Preparative<br />

HPLC, UV detection<br />

UV, DAD > 2 all VPV-007: Preparative<br />

HPLC, UV detection<br />

RID all all VPV-008: Preparative<br />

HPLC, RI detection<br />

A01264-1 05JE181E2J<br />

A01264-2 05JE181E2J<br />

A01265-1 05IE184E2J<br />

FPLC systems UV, DAD all all VPV-003: AZURA FPLC<br />

systems<br />

A01261-1 05WE184E2J<br />

Standards for PV | 74