1.0 Introduction<br />

Chapter-1<br />

General <strong>Specification</strong>s<br />

This document contains the generic requirements <strong>of</strong> self supporting type 21, <strong>18</strong>, <strong>15</strong> & <strong>12</strong><br />

m Ro<strong>of</strong> <strong>Top</strong> <strong>Tower</strong>s for Cellular wireless systems. The towers shall be <strong>of</strong> angular<br />

construction in segments <strong>of</strong> 3m with a square base. The towers shall be four legged and<br />

able to support the loading <strong>of</strong> the antennas as given below:<br />

a. 2 Nos. <strong>of</strong> 1.2m diameter Solid antenna at 2.0m from the top <strong>of</strong> tower.<br />

b. 4 Nos. <strong>of</strong> 0.6m diameter Solid Antenna at 2.0m from the top <strong>of</strong> tower.<br />

c. 6 Nos. <strong>of</strong> panel antennas for cellular wireless systems (2600X262X1<strong>15</strong>) weighing<br />

50Kg, 1m from the top <strong>of</strong> tower.<br />

1.1 Other parameter for designing <strong>of</strong> towers shall be as under<br />

a. Factor <strong>of</strong> Safety = 1.5<br />

b. Basic Wind Speed = <strong>18</strong>0 Km/hr<br />

c. Terrain Category = 2<br />

d. Building Height = 10m<br />

e. <strong>Tower</strong> twist and sway is found to be less than 0.5 deg @ 75% <strong>of</strong> basic wind speed.<br />

2.0 Detailed <strong>Technical</strong> Requirements<br />

2.1 Type <strong>of</strong> <strong>Tower</strong><br />

4 legged self supporting type with square base & Angular construction in segments <strong>of</strong><br />

3m. The details are indicated in drawing <strong>of</strong> tower.<br />

2.2 Foundation<br />

Beams shall be cast after connecting re-enforcement <strong>of</strong> the beams to the existing columns<br />

<strong>of</strong> the structure. Foundation bolts shall be placed in the beams using templates<br />

corresponding to the tower <strong>height</strong>. The columns and beams shall be RCC (M20). The<br />

existing columns shall be surveyed for the requisite capacity to carry the tower loads and<br />

the weight <strong>of</strong> the beams. Non-galvanized steel structures such as Anchor bolt etc. should<br />

be painted with red oxide coating. The base plates shall be galvanized as some <strong>of</strong> their<br />

portion may be directly exposed to environment.<br />

The foundation design/drawings <strong>of</strong> towers, given in the specifications UTL/RTT/02-01<br />

OCT 2011 and UTL/RTT/01-02 OCT 2011 may be considered for reference and actual<br />

foundation design/drawing shall be as per the actual site requirements.<br />

UTL/RTT/02-01 OCT 2011 Page 4 <strong>of</strong> 31