Routine maintenance kits<br />

routine maintenance kits are available for UNITY 1 and 2, TD-100,<br />

TT24-7, Air Servers and CIA systems. Kits contain sufficient<br />

consumable items (O-rings, PTFE filters, etc.) for approximately<br />

12 months’ use. Where indicated, the relevant cold trap is<br />

included (specify trap type p 77 with order).<br />

Suggested maintenance schedule<br />

Suggested maintenance frequencies are given below. However, in<br />

some cases (depending on the application), items may need<br />

replacing more frequently.<br />

UNITY 1 and 2<br />

Condition/change charcoal filter<br />

(split tube)<br />

TD-100<br />

UlTrA<br />

Air Server 3/8, CIA 8 and CIA Advantage<br />

Hints and tips<br />

3 months 1<br />

replace/repack cold trap 12 months 1<br />

replace fused silica transfer line 12 months<br />

Change sample tube O-rings/filters 12 months, or if damaged/leaking<br />

Cold trap seals 12 months, or if damaged/leaking<br />

Condition/change charcoal filter<br />

(split tube)<br />

3 months 1<br />

replace/repack cold trap 12 months 1<br />

replace fused silica transfer line 12 months<br />

Change sample tube O-rings/filters 12 months, or if damaged/leaking<br />

Cold trap seals 12 months, or if damaged/leaking<br />

replace O-rings in Difflok caps If damaged/leaking<br />

Change nozzle seals If damaged/leaking<br />

replace O-rings in Difflok caps If damaged/leaking<br />

Change nozzle seals If damaged/leaking<br />

replace filter disks 12 months<br />

► As well as routine maintenance procedures carried out by the<br />

user, it is strongly recommended that a routine maintenance<br />

service is carried out on your TD system, by a trained service<br />

engineer, at least once a year.<br />

1. Note that these parts may require changing more frequently in<br />

automated systems.<br />

T: +44 (0)1443 230935 T: 886-483-5684 (USA toll-free)<br />

79<br />

Description Part number<br />

Routine maintenance kit, UNITY 1,<br />

RMK-0001<br />

specify cold trap<br />

Routine maintenance kit, UNITY 1,<br />

RMK-0004<br />

without cold trap<br />

Routine maintenance kit (ECC), UNITY 1,<br />

RMK-012<br />

contains U-T11GPC cold trap<br />

Routine maintenance kit, UNITY 2, 3½″,<br />

RMK-0001-2S<br />

specify cold trap<br />

Routine maintenance kit, UNITY 2, 3½″,<br />

RMK-0004-2S<br />

without cold trap<br />

Routine maintenance kit (ECC), UNITY 2, 3½″, RMK-012-2S<br />

with U-T11GPC-2S cold trap<br />

Routine maintenance kit, UNITY 2, 4½″,<br />

RMK-0001-XZ<br />

specify cold trap<br />

Routine maintenance kit, UNITY 2, 4½″,<br />

RMK-0004-XZ<br />

without cold trap<br />

Routine maintenance kit, TD-100,<br />

RMK-0009<br />

specify cold trap<br />

Routine maintenance kit, TD-100,<br />

RMK-0010<br />

without cold trap<br />

Routine maintenance kit for TT24-7, specify cold RMK-0005<br />

traps (two supplied)<br />

Routine maintenance kit, 3½″, Air Servers and RMK-0003-2S<br />

CIA systems<br />

Markes’ TD service support<br />

specialists – There to support<br />

you and to back up our global<br />

network of service providers<br />

<strong>Instrument</strong> <strong>spares</strong>