CIA Advantage <br />

General information<br />

The CIA Advantage is an advanced system for automated analysis<br />

of VOCs in canister air. The main features are:<br />

• Cryogen-free operation, leading to substantial cost savings<br />

• Heated internal lines (up to 200°C) and uniquely efficient<br />

purging combine to eliminate carryover and increase sample<br />

throughput<br />

• Compatibility with high- and low-concentration samples in the<br />

same sequence<br />

• Compatibility with both canisters and sorbent tubes, allowing a<br />

wider range of applications to be accommodated.<br />

Two models are available:<br />

• The CIA Advantage-T incorporates mass flow control<br />

technology and provides a dedicated system for analysis of<br />

trace-level components. Up to four canisters are<br />

accommodated on the standard T model, and the minimum<br />

sample volume is 10 ml<br />

• The CIA Advantage-Hl is a versatile system for analysis of<br />

both high- and low-concentration samples and for screening<br />

unknowns. It incorporates gas-loop sampling in addition to<br />

mass flow control. Up to fourteen canisters are<br />

accommodated on the standard Hl model, and the minimum<br />

sample volume is 0.5 ml.<br />

Accessories available for the CIA Advantage include:<br />

T: +44 (0)1443 230935 T: 886-483-5684 (USA toll-free)<br />

73<br />

• The CIA Satellite module increases the capacity of both<br />

CIA Advantage models by 13 channels<br />

• Markes’ diluterp 41 offers accurate dilution of a standard gas,<br />

allowing the creation of multiple calibration levels from a<br />

single original standard<br />

• Markes’ canister racksp 41 hold up to 15 canisters<br />

(14 samples and one internal standard)<br />

• The addition of Markes’ UlTRA autosamplerp 71 to<br />

CIA Advantage systems allows up to 100 sorbent tubes to be<br />

processed automatically.<br />

Further information on all accessories for the CIA Advantage is<br />

available on our website and in the relevant brochures. Please<br />

email us (enquiries@markes.com) for more information, or contact<br />

your local distributor.<br />

Spares and consumables<br />

Filter, disk,<br />

sintered PTFE<br />

(inside sample ports)<br />

U-DISK4<br />

Description Part number<br />

Dryer kit for CIA Advantage systems U-ASDRY<br />

Humidifier, for humidification of purge gas U-HUMID<br />

Heated sample lines (14 lines, each 1.8 m length) U-HTLNKT<br />

Filter, disk, sintered PTFE, 3.2 mm section, pk 10 U-DISK4<br />

Pump, 115 V, for unpressurised samples U-ASPM1<br />

Pump, 230 V, for unpressurised samples U-ASPM2<br />

Split filter tube, glass, 3½″, packed with charcoal SERAAA-1600<br />

Sample loop, 0.1 mL SERZ-0993<br />

Sample loop, 0.5 mL SERZ-0994<br />

Sample loop, 1 mL SERZ-0516<br />

Sample loop, 2 mL SERZ-0995<br />

<strong>Instrument</strong> <strong>spares</strong>