Proportional, high-response and servo-valves<br />

Detailed information:<br />

RE 29064<br />

Detailed information:<br />

RE 29050<br />

Type 4WREEM<br />

68 <strong>Industrial</strong> <strong>Hydraulics</strong> Bosch Rexroth AG<br />

Proportional directional valves, direct operated,<br />

with integral control electronics, electrical position feedback and<br />

spool position monitoring<br />

< Sizes 6 and 10<br />

< Porting pattern to DIN 24340 form A and ISO 4401<br />

< Control of the direction and magnitude of a flow<br />

< Proportional solenoid operation<br />

< Spring-centered control spool<br />

< Different spool overlaps possible<br />

< Deadband compensation firmly set in the factory<br />

Size 6 10<br />

Operating pressure pmax bar 315 315<br />

Nominal flow (∆p = 10 bar) qV nom L/min 8, 16, 32 25, 50, 75<br />

Maximum hysteresis % ≤ 0.1 ≤ 0.1<br />

Step response 0 to 90 % Tu +Tg ms 20 40<br />

Operating voltage U V 24 24<br />

Comm. value signal U V ± 10 ± 10<br />

Proportional directional valves, direct operated with integral control<br />

electronics, el. position feedback and closed-loop control of pressures<br />

< Sizes 6 and 10<br />

< Porting pattern to DIN 24340 form A and ISO 4401<br />

< Closed loop control in A and B, and, if applicable, area-related differential pressure<br />

< Integral digital control electronics<br />

< 1 to 4 integrated pressure sensors or one external pressure sensor<br />

< Version for CAN bus with protocol CANopen (DS-408) or Profibus DP (on inquiry)<br />

< All parameters (ramps, controllers,...) can be adjusted via the field bus interface<br />

< Extended diagnosis functions via field bus<br />

Type 4WREQ<br />

Size 6 10<br />

Operating pressure pmax bar 315 315<br />

Nominal flow (∆p = 10 bar) qV nom L/min 8, 16, 32 25, 50, 75<br />

Maximum hysteresis % 0.1 0.1<br />

Step response 0 to 90 % Tu +Tg ms 20 40<br />

Operating voltage U V 24 24<br />

I mA < 2 < 2<br />

Comm. value signal Min. comm. value V ± 10 ± 10<br />

Flow comm. value mA 4 to 20 4 to 20<br />

Press. comm. value V 0 to 10 0 to 10